Agilent G4236A 2D-LC Valve Installation Guide

Similar documents
Agilent Online-SPE Direct Inject Kit G4744A

Agilent G4239C Valve Kit - Instructions

Agilent InfinityLab Quick Change Valve G4235A Instructions

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent InfinityLab Quick Change Valve G4237A

Agilent G5632 Valve Kit Instructions

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment

Dual-Needle Infinity II Upgrade Kit

1260 Infinity II Multicolumn Thermostat

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Agilent SD-1 Purification System ml/min

Agilent 1290 Infinity Autosampler

Agilent 210/218 - Isocratic Pump

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

Agilent 210/218 - Binary Pump

Agilent 1290 Infinity II Ultra Low Dispersion Kit

Agilent 1200 Series Thermostatted Column Compartment G1316A/G1316B/G1316C

Agilent InfinityLab LC Series Multi-wash Upgrade Kit

Agilent 1200 Series Valves

Agilent 1100 Series Thermostatted Column Compartment. Reference Manual

Agilent 1200 Series Manual Injector

CHROMATOGRAPHY. SYKAM S 6000 Valve Series

Agilent 1260 Infinity Bio-inert Manual Injector

Agilent 1260 Infinity Manual Injector

HIGH PRESSURE SWITCHING VALVES

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

FITTINGS, LOOPS, AND VALVE ACCESSORIES

Agilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler

Agilent 218 Purification Solution

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

G1160A Agilent 1100 Series Multiple Purpose Switching Valve

Nickel Catalyst Tube Accessory 19205A

Agilent 1260 Infinity Standard Autosampler

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

TECHNICAL SERVICE BULLETIN: TSB

1110 Valves. Introduction

1350 Valves. 1 of 14. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

Customer Information. Service Engineer s Responsibilities. Agilent Cary 7000 UMS/UMA/Solids Autosampler

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Agilent 1200 Series Standard and Preparative Autosamplers

Quick Reference Guide. Supplies for Waters HPLC Systems

Neueste LC Entwicklungen

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

1260 Infinity II Degasser User Manual. 5 Maintenance

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual

LC Instrument Replacement Parts

Hot Injection Adapter Kit - Installation Guide

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Thermo Scientific Dionex UltiMate 3000 Thermostatted Column Compartment

System Manual. Agilent 1260 Infinity Capillary LC System

Installation Guide Thermal Conductivity Detector Accessory 19232E

Chrom Tech your chromatography specialists. IDEX Injection Valves Manual. IDEX Injection Valves Actuated. 1/4-28 Flat-Bottom Injection Port Adapter

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

For more information about Agilent Technologies services please visit our web site using the following URL

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Liquid Handling Station

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Replacing the Column Stabilizer Tube with Finger-tight Fittings

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Mounting Bracket AZURA L Supplement HPLC. Document No. V6806

Agilent 1100 Series Capillary LC System. System Manual

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Liquid Chromatography LC Consumables SSI-LC

Application Note. Authors. Abstract. Energy & Chemicals

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

Agilent 1200 Series Nano Pump

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Agilent 1260 Infinity Binary Pump VL

EPOND SA CP 389 CH Vevey Switzerland.

Agilent 1260 Infinity Analytical SFC System

Technical Procedure for Gas Chromatography (GC-FID)

Agilent 1260 Infinity High Performance Micro Autosampler

Agilent 1290 Infinity Quaternary Pump

CETAC Z-Drive Nylon Cable

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.

Agilent G2738A Upstream Capillary Interface

Determination of Sudan Dyes I IV in Curry Paste

Agilent 1260 Infinity Bio-inert High Performance Autosampler

LC20 CHROMATOGRAPHY ENCLOSURE OPERATOR S MANUAL Dionex Corporation

Your Essential Resource for INFINITYLAB LC SUPPLIES

Agilent 1290 Infinity Quaternary Pump

Deans Switch Microfluidics

CTC Analytics Service Note June 2015 PAL-xt: Material change for Rotor Seal of C2V-3006-CTC

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Transcription:

Agilent G4236A 2D-LC Valve Installation Guide Technical Note Contents Delivery Checklist 2 Installing Valve Heads 3 Removing the Transportation Lock and the Valve Dummy 3 Installing the Valve Head and Connecting Capillaries 4 Thermostatted Column Compartment Setup 7 Installing the Capillaries 8 Comprehensive 2D-LC 9 Heart-cutting 2D-LC 10 Valve Head Parts Information 11 Replacement Parts 11 Valve Head Parts 11 Technical Specifications 12 Agilent Technologies

Delivery Checklist Delivery Checklist p/n Description 5067-4214 2D-LC Valve Head, 1200 bar 5067-5440 Calibrated loop kit for 2D-LC (OPTIONAL) 5067-5441 Capillary kit for 2D-LC, low dispersion (OPTIONAL) Calibrated loop kit for 2D- LC (5067-5440) p/n Description 5067-5446 (2x) Loop housing kit 5067-5424 20 µl Loop 2D-LC 5067-5425 40 µl Loop 2D-LC 5067-5437 60 µl Loop 2D-LC 5067-5426 80 µl Loop 2D-LC Table 1 Capillary Kit for 2D-LC, low dispersion (p/n 5067-5441) Description Amount Unit Comment Capillary ST 0.12 mm x 600 mm S/SL (5067-4669) 1 ea Autosampler to 1 st dimension column / low dispersion heat exchanger SST-Capillary 150 x 0.12 mm ns ps 1lg 1xlg (5067-4650) 1 ea 1 st dimension column outlet to valve (short column) SST-Capillary 280 x 0.12 mm ns ps 1lg 1xlg (5067-4651) 1 ea 1 st dimension column outlet to valve (long column) SST-Capillary 90 x 0.12 mm ps ps 1sh 1xlg (5067-4649) 1 ea Valve to 2 nd dimension column SST-Capillary 200 x 0.12 mm ps ps 1sh 1xlg (5067-4653) 1 ea 2 nd dimension column outlet to detector Heater long-up ( 0.12 mm i.d., 1.6 µl internal volume) (G1316-80002) 2 ea Carrier for heat exchanger TCC SL Plus (G1316-89200) 2 ea Waste tubing, 2 m (0890-1713) 1 ea Fitting male PEEK, 2/pk (0100-1516) 1 ea 2

Installing Valve Heads Installing Valve Heads The valve drives are factory- installed in the thermostatted column compartment and in the 1290 infinity valve drive. The valve heads are interchangeable and can be easily mounted. At the first installation, the transportation lock (TCC only) and the dummy valve have to be removed, see Removing the Transportation Lock and the Valve Dummy on page 3. The valve heads can be installed by mounting the valve heads onto the valve drives and fastening the nut manually (do not use any tools). Be sure that the guide pin snaps into the groove of the valve drive thread. The valves are mounted on pull- out rails to allow easy installation of capillaries. Push the valve gently into its housing until it snaps into the inner position, push it again and it slides out. If all capillaries are installed, push the valve back into its housing, see Installing the Valve Head and Connecting Capillaries on page 4. Removing the Transportation Lock and the Valve Dummy The following procedure demonstrates the necessary steps for installing the valve head to the valve drive of a TCC. For the installation of a valve head to a G1170A Infinity Valve Drive you can ignore the steps that describe the TCC features of the transportation lock and spring loaded valve drive. 1 When unscrewing the transportation lock (TCC only), push it back until the last screw is removed - the valve rail is spring-loaded 2 To remove the valve dummy, loosen the nut manually. 3

Installing Valve Heads Installing the Valve Head and Connecting Capillaries For bio-inert modules use bio-inert parts only! CAUTION The valve actuator contains sensitive optical parts, which need to be protected from dust and other pollutions. Pollution of these parts can impair the accurate selection of valve ports and therefore bias measurement results. Always install a valve head for operation and storage. For protecting the actuator, a dummy valve head (part of Transportation Lock Kit (G1316-67001 )) can be used instead of a functional valve. Do not touch parts inside the actuator. CAUTION Column Damage or Bias Measurement Results Switching the valve to a wrong position can damage the column or bias measurement results. Fit the lobe to the groove to make sure the valve is switched to the correct position. CAUTION Valve Damage Using a low pressure valve on the high pressure side can damage the valve. When using multiple column compartments as part of a method development solution, make sure that the high pressure valve head is connected to the autosampler and the low pressure valve head is connected to the detector. CAUTION Sample degradation and contamination of the instrument Metal parts in the flow path can interact with the bio-molecules in the sample leading to sample degradation and contamination. For bio-inert applications, always use dedicated bio-inert parts, which can be identified by the bio-inert symbol or other markers described in this manual. Do not mix bio-inert and non-inert modules or parts in a bio-inert system. NOTE The tag reader reads the valve head properties from the valve head RFID tag during initialization of the module. Valve properties will not be updated, if the valve head is replaced while the module is on. Selection of valve port positions can fail, if the instrument does not know the properties of the installed valve. NOTE To have the valve correctly recognized by the Agilent Infinity valve drive you must have the valve drive powered off for at least 10 s. 4

Installing Valve Heads 1 The two different pins (blue & green) on the valve shaft must fit into the corresponding grooves of the actuator axis. The outside pin (red) must fit into the outside groove. 2 a It can be possible that you have to turn the valve head until the outside pin completely locks in. While turning the valve you should feel some resistance from the drive. Otherwise the pins on the valve shaft are not properly fitted into the corresponding adapters on the valve drive. b It can be possible that you have to turn the valve head until the outside pin completely locks in. While turning the valve you should feel some resistance from the drive. Otherwise the pins on the valve shaft are not properly fitted into the corresponding adapters on the valve drive. 5

Installing Valve Heads 3 When the outer pin is locked into the groove, manually screw the nut onto the valve head. 4 Install all required capillary connections to the valve. NOTE Fasten the nut manually. Do not use any tools. 5 Push the valve head until it snaps in and stays in the rear position. (TCC only) 6 Power on or power-cycle your TCC or Infinity valve drive that the valve head gets recognized during the module initialization. NOTE Power Off the Infinity valve drive for at least 10 s. 6

Thermostatted Column Compartment Setup Thermostatted Column Compartment Setup Different variants of thermostatted column compartment setup are supported with the optional 2D- LC capillary kit for the 2D- LC valve (G4236A#3): To waste To detector Column 2nd dimension (max. 100 mm) Loop-holder with one or two loops Low dispersion heat exchanger Low dispersion heat exchanger From autosampler 1st dimension (left stack) Column 1st dimension (max. 250 mm) Figure 1 From pump 2nd dimension Columns at different temperatures,long 1 st dimension column, no 1 st dimension detector, for comprehensive 2D-LC booth loops can be placed in the loop holder. To detector To waste Column 2nd dimension (max. 100 mm) Loop 1 Low dispersion heat exchanger Low dispersion heat exchanger Column 1st dimension (max. 100 mm) From autosampler 1st dimension (left stack) Loop 2 From pump 2nd dimension Figure 2 Columns at different temperatures, medium 1 st dimension column, no 1 st dimension detector 7

Installing the Capillaries Installing the Capillaries The hydraulic setup of the valve is optimized for 2D- LC applications. CAUTION Wrong flow path setup Damage to the valve. Strictly follow the setup instructions in the section Installing the Capillaries. 8

Installing the Capillaries Comprehensive 2D-LC Comprehensive 2D-LC Cocurrent: The flow for filling and eluting (analyze direction) the loops is entering the loop from the same side for the cocurrent plumbing. Countercurrent: The flow entering the loops for filling and analyzing is opposite for the countercurrent plumbing. Table 2 Plumbing for 2D-LC Valve Head, comprehensive 2D-LC Filling Analyzing Cocurrent Figure 3 2D-LC Valve Head, position 1 Figure 4 2D-LC Valve Head, position 2 Countercurrent Figure 5 2D-LC Valve Head, position 1 Figure 6 2D-LC Valve Head, position 2 9

Installing the Capillaries Heart-cutting 2D-LC Heart-cutting 2D-LC In a heart- cutting experiment only a part of the first dimension is transferred to the second dimension and analyzed. Table 3 Plumbing for 2D-LC Valve Head, heart-cutting 2D-LC Filling Analyzing Cocurrent Figure 7 2D-LC Valve Head, position 1 Figure 8 2D-LC Valve Head, position 2 Countercurrent Figure 9 2D-LC Valve Head, position 1 Figure 10 2D-LC Valve Head, position 2 10

Valve Head Parts Information Replacement Parts Valve Head Parts Information Replacement Parts Table 4 Partlist 2D-LC Valve Head, 1200 bar Valve Rotor Seal (Vespel) Stator Head Stator Screws (pack of 10) Stator Ring 5067-4214 2D-LC Valve Head, 1200 bar 5068-0186 5068-0115 1535-4857 n.a. Valve Head Parts NOTE The figure below illustrates replacement parts for the valve heads, with the 12Pos/13Port Selector valve as an example. The valves can vary in their appearance and do not necessarily include all of the illustrated parts. Neither, every spare part is available for each flavor of the valve. Figure 11 Valve Head Parts (example shows a 5067-4159 valve head) 1 Stator screws 2 Stator head assembly 3 Stator face assembly 4 Stator ring (available for service only) 5 Rotor seal 6 Bearing ring (P/N 1534-4045) 7 Spanner nut (P/N 5068-0106, available for service only) 11

Technical Specifications Valve Head Parts Technical Specifications Table 5 Technical specifications Max. Pressure: Liquid Contacts: Connections: 1200 bar Stainless Steel, Vespel Accepts 10-32 male threaded fittings, use non pre-swaged fittings to connect *G4236-90001* *G4236-90001* G4236-90001 Part Number: G4236-90001 Edition: 10/2013 Printed in Germany Agilent Technologies, Inc 2012-2013 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn Germany