INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

Similar documents
RELIABILITY THROUGH TECHNOLOGY

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

EMIU 720W Mini Inverter

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

EMEX. Central Battery Systems Emergency Lighting

Illuminator Series CR NEMA 3R

CEPS Series UL924 Emergency Lighting Inverters

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

GLX. Series. 1kW to 16kW Central System

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

UL AND CODE COMPLIANCE

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

.3 Section Waste Management and Disposal.

Sola 3000 Guide Specifications

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

MODEL NUMBER: APS2448UL

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

MODEL NUMBER: APS3636VR

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Aurora Single Phase Emergency Lighting Inverters

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

MODEL NUMBER: APS2424

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

The Power of Reliability INSTRUCTION MANUAL

MODEL NUMBER: APS2012

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

Uninterruptible Power Systems

Micro Lighting Inverter

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

Application. Battery. Public Grid GS HYBRID INVERTER

MODEL NUMBER: APS750. Highlights. Package Includes. Description

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Table of Contents 文管中心 發行章

Installation and Operation Back-UPS BX550CI-CN

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

3 Uninterruptible Power Systems

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

Technical Data Sheets

MODEL 422 Submersible Pump Controller

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

SECTION DC POWER SUPPLY/BATTERY CHARGER

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

POWER kva

Three Phase UPS Systems Range: 10 to 500kVA

TECHNICAL DATA SHEET KVA UPS Systemss

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

ELECTRONIC HID BALLASTS

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

POWER WAVE 1 SINGLE-PHASE, (3 TO 20 KVA) & (3 TO 17 KW) UL924 CENTRAL LIGHTING INVERTER

POWER kva

INVERTER/CHARGERS Off-Grid Power Solutions

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Technical Data Sheets

Crucial Power Products

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Features and Benefits

Emergency Lighting Products Limited

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

Transcription:

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE RELIABILITY THROUGH TECHNOLOGY

FOR ECONOMICAL, RELIABLE POWER IN AN EMERGENCY, DEPEND ON MINI INVERTERS LED technology in emergency lighting systems has increased efficacy and decreased energy requirements so that an entire floor or large area can be powered by a Mini Inverter. Today s highly efficient Mini Inverter-powered emergency lighting systems consume less energy and require fewer units for maximum economy and reliability. Ready-Lite is known for high quality, reliable emergency lighting and exit signs for commercial and harsh industrial environments. Manufacturing and production operations in Canada allow Ready-Lite to offer optimal lead time, service, and quality. Mini Inverter Features Provides 300W to 1440W of emergency power to exit signs and emergency lighting equipment for 30 minutes. Optimizes space by powering multiple remote fixtures, and allows additional Mini Inverters to be added where needed, instead of requiring one large central emergency power system. Powers normally-on light fixtures in an emergency, providing an aesthetically-pleasing option for high-visibility areas. Provides 100% power/lumen output, with less than 1 second of transfer when power fails. Allows fixtures to be on, off, switched or dimmed (TRIAC dimming), and can be used with LED fixtures and most light sources except HID. 1

Nexus real-time monitoring system compatibility provides higher levels of reliability. Ready-Lite Mini Inverters are compatible with the Nexus real-time monitoring and network management system. Diagnostics, monthly and annual functional tests required by building codes, maintenance logs, and compliance reports for Mini Inverter-powered exit signs and emergency lighting (including LED fixtures) can all be managed with the Nexus system. Nexus monitors total load on the mini-inverter from a central control unit. Using wireless communication and building automation, the Nexus system can contribute to achieving LEED certification and sustainability objectives. Designed and manufactured for reliability. Ready-Lite Mini Inverters have fully-featured self-diagnostics that test all connected loads and batteries, and use a long-life, maintenance-free, lead acid battery to ensure that when the main power fails, the emergency lighting system will be on. Each Mini Inverter is cul Listed and meets CSA141-15, and is designed and manufactured for North American safety standards. RELIABILITY THROUGH TECHNOLOGY When main power fails, rest assured that the Mini Inverter is ready to power the emergency lighting system. For increased reliability, the Mini Inverter can be connected to the Nexus monitoring and network management system. Nexus provides real-time visibility and control of the entire emergency lighting and exit sign system for extra safety and security assurance. 2

Fan Inverter Module Terminal Block Charger Board Charger Transformer Valve Regulated Sealed Lead-Acid Battery 120/347 Transformer (optional) CHOOSING THE RIGHT BACKUP POWER SYSTEM Back-up power can be provided in many ways. However, even though certain methods are suitable for critical applications, they may not be suitable for Emergency Lighting. This is because an Emergency Lighting system has unique load characteristics. Since Emergency Lighting is a critical life safety installation, it must be designed with its specific load characteristics in mind. Mini Inverter systems are specifically designed to provide emergency power for Emergency Lighting systems in a power failure. 3

MINI INVERTER FEATURES & BENEFITS FEATURES Self-Diagnostics/Self-Testing The diagnostic/charger is a fully self-contained, fully automatic microcontroller- based system. Any fault condition causes a status LED indicator to blink, identifying the nature of the fault. Every 30 days, the sequence generator will generate a command to energize the transfer relay for a variable test period based on code requirements (1 minute each month, 10 minutes after 6 months, and 30 minutes after 12 months). System Design Inverter and charger modules utilize highly reliable solid state electronics.the modules feature input and output protection, and they measure and limit their own current. Capacity Capacity is available starting at 300W up to 1440W in 120V and 347V (347V not available in 300W) True Sine Waveform Using a solid-state, pulse width modulation (PWM) inverter, Mini Inverter systems produce pure sinusoidal output waveform with less than 5% Total Harmonic Distortion (THD) for linear loads. Nexus Monitoring System The Mini Inverter is compatible with Nexus, a real-time monitoring system that manages the status of the total load on the mini-inverter from a central control unit. Nexus runs diagnostics, performs required monthly and annual functional tests as per Building Codes, generates maintenance logs and runs compliance reports. BENEFITS Code Compliance Reduces testing/service time for a minimal maintenance cost, while ensuring that local safety codes are met, and provides system reliability in a power failure condition. High Performance The Mini Inverter is a rugged, easy-to-maintain system with exceptional performance for emergency lighting use. It offers exceptional overload performance without the need to over-specify the rating. Versatile Applications Mini Inverter systems can be used in almost every type of building, and are ideal for architecturally sensitive applications or when maintenance costs and testing of individual unit equipment becomes significant. The smaller unit size of the Mini Inverter allows more flexibility and minimizes testing. The Mini Inverter can be installed at a distance, offering the opportunity to hide the unit from view and maintain the architectural design by powering normally-on luminaires. Maximum Light Output The Mini Inverter will deliver 100% power / lumen output of the fixture up to the specified run time. It is compatible with all fluorescent ballast, LED drivers or incandescent light sources. Reliability Through Technology Nexus allows for maintenance time and cost savings, and ensures that the emergency lighting fixtures will perform when needed. Nexus can contribute to LEED certification and support sustainability objectives. 4

new product Type: Project/Location: Contractor: Prepared By: Date: Model No.: MINI-INVERTER SERIES Interruptible Unit Equipment FEATURES Lamps operated: Incandescent LED, fluorescent lamps and ballast combinations, including TRIAC dimmable ballasts Components: High-efficiency pure sine wave inverter Temperature-compensated charger 12V oversized Valve Regulated lead acid (VRLA) battery Construction: 18-gauge steel for 300W & 600W/ 14-gauge steel for 1000W & 1440W Emergency lighting supplied from one convenient, reliable source Input/Output voltage 120/120V 60Hz or 347/347V 60 Hz Replaceable output fuse protection Valve Regulated Lead Acid (VRLA) battery provides long-life and is maintenance free Line voltage allows remote mounting of emergency fixtures; distances up to 1000 ft. Low Battery Voltage Disconnect Unit comes standard with electonic lockout and brownout circuits Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Cabinet in factory white powder-coat paint finish May accept load to it s full capacity when load feature power factor of 0.9 or more Non audible self-diagnostic is standard. Nexus system interface available with an improved minimum lost detection of 10% Standard lighting control override for 0-10V dimming systems Meets or exceeds the requirements of CSA 141-15 The Mini-Inverter is a cul Listed stand-alone pure sine wave output inverter designed to provide power to designated emergency lighting fixtures. In a power loss situation, it will supply power from the onboard battery supply. The Mini-Inverter works in conjunction with incandescent, LED, and fluorescent fixture types and will automatically run switched, normally-on, or normally-off designated emergency fixtures. The Mini-Inverter is ideal for applications requiring an emergency source for lighting arrangements that utilize multiple lamp and fixture types and is available in surface mount and comes with a one year warranty and nine-year pro-rata battery warranty. TYPICAL SPECIFICATIONS Emergency lighting shall be provided by inverter unit equipment designed to operate designated incandescent, fluorescent and LED fixtures on emergency power at their full nominal lumen rating during the full 30 minute emergency discharge cycle. System output will be rated at watts for 30 minutes and provide fused output connections to the load. The system s voltage rating shall be VAC input/output nominal. The inverter unit shall allow for fused connected emergency fixture(s) to be normally on, normally off, switched or dimmed without affecting lamp operation during a power failure. Upon utility power loss, the inverter unit shall deliver 100% of its rated output to the emergency fixtures regardless of the local switch or dimmer (TRIAC) position, and will provide power to emergency fixtures at distances of up to 1000 feet. The housing shall be manufactured using 18-gauge steel for 300W & 600W/ 14-gauge steel for 1000W & 1440W with a white baked-on powder coat paint finish. The unit s electronics shall include a self-contained inverter section with a fully automatic, thermal-compensating variable-rate battery charger, AC lockout feature, low battery voltage disconnect, overload, short circuit and brownout protection as standard. The unit shall utilize a sealed lead acid battery with a 10-year design life. The inverter system shall be cul Listed and labeled. The unit shall be covered under a 1-year warranty on the electronics and battery and a 9-year pro-rata warranty on the battery. It shall meet or exceed the requirements of CSA 141-15. SPECIFICATIONS TRANSFER TIME: less than 1 second VOLTAGE REGULATION ON EMERGENCY: +/- 3% FREQUENCY REGULATION ON EMERGENCY: 60 Hz +/- 1% LOAD POWER FACTOR RANGE: 0.9 leading to 0.9 lagging OPERATING TEMPERATURE: 20 TO 30 C (68 TO 86 F) WARRANTY All Ready-Lite inverter products receive 100% quality inspection before shipment to insure proper and satisfactory operation. When operated under normal conditions, Ready-Lite inverter products will provide years of dependable service. This unit is backed by a complete 1-year warranty against defects in material or workmanship, and a 9-year prorata battery warranty. The inverter unit shall be Ready-Lite model:. ELECTRICAL CHARACTERISTICS & DIMENSIONS POWER RATING WEIGHT W/O MAX. INPUT RATING SINE CABINET DIMENSIONS WEIGHT INSTALLATION NO. OF BATTERY BATTERY 120VAC 347VAC WAVE W H D 120V 347V 120V 347V 300W 3.10 n/a Pure Wall 27 12.25 7.25 1 55 lbs n/a 30 lbs n/a 600W 6.00 2.30 Pure Wall 24 20.25 10.5 2 105 lbs 117lbs 55 lbs 67lbs 1000W 11.60 3.60 Pure Wall 24 20.25 14.5 2 150 lbs 169 lbs 70 lbs 89 lbs 1440W 15.00 5.00 Pure Wall 24 20.25 14.5 2 190 lbs 214 lbs 75 lbs 99 lbs 5

Type: Project/Location: Contractor: Prepared By: Date: Model No.: new product WIRING DIAGRAM 120 VAC 120V Emergency Lighting Load Fluorescent, LED, Incandescent Neutral Line 120VAC switched Line 120VAC unswitched Charger Relay CTRL + - Inverter Inverter CTRL Load Neutral 120VAC Load Line MINI-INVERTER SERIES Interruptible Unit Equipment + - Battery 347 VAC 347V Emergency Lighting Load Fluorescent, LED, Incandescent Neutral Line 347VAC switched Line 347VAC unswitched Charger Relay CTRL Inverter CTRL Load Neutral 347VAC Load Line + Inverter - + Battery - POWER CONSUMPTION AND UNIT RATING MODEL NUMBER AC SPECS EMERGENCY POWER AVAILABLE FOR LOAD 30MIN 1H00 1H30 2H00 4H00 RMI-300 120Vac 3.10 Amps 300W 175W 125W 100W 50W RMI-600 6.00 / 2.30 Amps 600W 350W 250W 200W 100W RMI-1000 120 / 347Vac 11.60 / 3.60 Amps 1000W 585W 415W 330W 165W RMI-1440 15.00 / 5.00 Amps 1440W 842W 600W 480W 240W ORDERING INFORMATION SERIES CAPACITY VOLTAGES IN/OUT DIAGNOSTIC FEATURES OPTIONS RMI= Series -300= 300W -600= 600W -1000= 1000W -1440= 1440W -1= 120/120VAC, 60 Hz -3= 347/347VAC, 60 Hz* Blank= auto-diagnostics, non-audible* -AD= auto-diagnostics, audible* -NAD= No diagnostics -NEX= NEXUS wired system interface** -D3= time delay (15 minutes) -LC= line cord (120V only) -SAC= service alarm contact -TL= cord & twist lock plug (120V only) -NEXRF= NEXUS wireless system interface** EXAMPLE: RMI-1440-1 * Available only with 600W, 1000W & 1440W * Minimum load required: 10% of unit capacity ** Please consult your sales representative 6

www.ready-lite.com All information and specifications contained in this flyer are subject to change due to engineer design, errors and omissions. Illustrations and diagrams within this flyer may vary from actual products. 2016. Thomas & Betts Limited. All rights reserved. Printed in Canada 03/16/500. Order no. RL-MINIINVERTER-E.