Don t get caught out by the Sharps Directive

Similar documents
for Kids Infusion Therapy Products for Neonatal and Pediatric Patients

COMPLETE PROCEDURAL SOLUTIONS COMPLETE PROCEDURAL SOLUTIONS


POLYMED CATALOGUE 2013 POLYCARBONATE STOPCOCKS MANIFOLDS - CONNECTORS

Syringe Infusion Solutions

Your brand for interventional products

Smiths Medical Infusion Disposables for Syringe Infusions

Syringe Infusion Solutions

ANgio-Line tm. Angiography & Cath-Lab Product Range

US Product Catalog and Ordering Information July 2011

Angio-Line TM. Hemostatic Valve Introducer Sets. Femoral Approach. Radial Approach. Electrophysiology Split Sheath Introducer Sets

Specialty Devices Inside U.S Outside U.S Europe: Disposal Basins

Closed Fluid Systems

CADD Amulatory Ambulatory Infusion Systems CADD. Ordering Information. CADD Tubing Sets with Flow Stop Free-Flow Protection.

CADD Ambulatory Infusion Systems

ANgio-Line tm. Angiography Product Range

Invention Enhances Life...

Needle-Free Injection System. User Manual

MOLDED PARTS & COMPONENTS. Molded Parts & Components

Pressure Monitoring January 2013

The first name in biopsy. Jamshidi biopsy devices

CADD Ambulatory Infusion Systems

EMBOLOTHERAPY EMBOLOTHERAPY

Quick Reference Guide

BODYGUARD 323 AMBULATORY INFUSION PUMP

ANGIOGRAPHY & CATH-LAB

Standards for type I, type IIa, type II, and type V ground ambulance

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)

BRONCHOPART CLEAR DOUBLE-LUMEN BRONCHIAL TUBE MADE OF PVC BRONCHOPART TUBE SET

Standards for type I, type II, type IIA, and type V ground ambulances and

BODYGUARD 595 REGIONAL ANALGESIA INFUSION PUMP

Going home with a CADD Pump - Chemotherapy Medication

EPOND SA CP 389 CH Vevey Switzerland.

Pain management kitting solutions

DIAGNOSTIC CARDIOLOGY

International. The Stent Company. Product Catalogue. Interventional Cardiology Peripheral Vascular Non Vascular

Universal Pipette Tips Ultra-clear and certified RNase/DNase-free

CRONO S-PID 50 Ambulatory infusion pump

BodyGuard 121 Twins Infusion System Operator Manual

Patient s Manual for Using Nimbus Ambulatory Pump for Continuous Peripheral Nerve Block Application

MOOG Medical Devices Group Curlin 6000 Series Ambulatory Infusion Pump PATIENT GUIDE

Instruction for Use (IFU)

Accumate 2300 Volumetric Infusion Pump

SmartVent. Instructions for Use Version 4 (Dec 2009)

Operator Manual of Guangzhou Huaxi Medical Technology Co., Ltd. JORVET INFUSION PUMP J1060 OPERATOR MANUAL

DARA PHARMACEUTICAL PACKAGING

KEY FEATURES. Compact components for 360 µm, 1/16, and 1/32 inch ID tubing Fast, breadboard-based design Leak-free high pressure setups

Robins Company. A New Generation of Animal Health Devices

Leaded Glass Vial Shields Models to Stainless Steel Vial Shield Model

Designer and manufacturer of medical trolleys

UNITED STATES. A Nissha Company. Disposable Medical Waste & Sharps Containers

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

CRONO TWIN. Ambulatory infusion pump USER MANUAL

BID TABULATION 1 of 5

Multi Therapy Solutions

Zebra Healthcare Supplies Catalog

Nimbus Flex Ambulatory Infusion Pump

Mitos P-Pump Accessories

Ordering Information Blood Collection Systems

Flow System Accessories

What s in a Kit? A Supply Show and Tell to Facilitate Billing Accuracy

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Multi Therapy Solutions

BodyGuard 323 Infusion Pump System Operator Manual

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Using Your CADD Prizm Pump

Research on the micro liquid flow standard system and inter-comparison

LEADER IN VALVE TECHNOLOGIES USA Toll Free: Europe:

Jamshidi bone marrow biopsy needles

CADD -Solis VIP Ambulatory Infusion Pump Model 2120

system We protect your health. Innovative disposable non-woven wipe dispenser system for surface disinfection with 50% longer standing time*

PEDIATRIC AND NEONATAL TRACHEOSTOMY CANNULA WITHOUT CUFF

SPARE PARTS LIST. CHAIN SAWS 135 from

KD1E Range Potential Indicators

Operator s Manual. spectrum 35700BAX & 35700ABB. Generation 2 Operating System Pump Operating Software v6.05 For Use with MDL Editor v6.2.

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

MODEL 905V OPERATING INSTRUCTIONS

FITTINGS, LOOPS, AND VALVE ACCESSORIES

Dedicated, ambulatory nerve block and wound infiltration treatment

10% off Anesthesia Machines

Pain Management Solutions

Perfusion Valve Controller

CRONO S-PID NEW MODEL. Ambulatory infusion pump USER GUIDE

Infusion Systems Product Catalog. Effective January, B. Braun Medical Inc. 1/18

Arrow Central Venous Systems Stay ahead of risk

(12) United States Patent (10) Patent No.: US 7,056,316 B1

Porous Packaging Inspection Solutions Non-Destructive Package Testing

Corning 125 and 500 ml Disposable Spinner Flasks Ordering Information. Replacement Caps and Asceptic Transfer Caps Ordering Information

SPARE PARTS LIST. CHAIN SAWS 135 from

Thermo Scientific HyClone Single-Use Mixer (S.U.M.) 200 L

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Vari-Disk Service. Inline disc filters to meet your needs. Inlet and outlet connectors. Filter housing

HotPot. Shielded Dry Heating Block SYRINGE AND VIAL SHIELDS 35 C-TEC SYRINGE SHIELD ILLUMINATED VIAL SHIELD

Needle OD (mm) Needle ID (mm) Needle Gauge

MEDIPLAST ENT PRODUCTS FAST EASY SAFE

Pain Management Solutions

Code Cart. Purpose. Scope. Physician's Order

RÜSCH SURGERY AND GASTROENTEROLOGY. Quality with a fine tradition

Medical Waste Transporters

Transcription:

Don t get caught out by the Sharps Directive Total Needle Free Solutions From Fannin

Sentra Safety IV Cannula Self activating safety needle guard with plastic cap Plastic safety cap reduces blood splatter No additonal cannulation technique required Ported, non-ported and non-ported, non-winged Safety Cannulation Kit options Cannula Intravenous Ported Winged Safety Supply Chain Code Ref Size Catheter ID/ODmm Catheter Length Water Flow Rate ml/min Supplier Code Box Qty FSB1126 14G 1.7/2.1 45 305 A/1101/14/P 50 FSB1127 16G 1.3/1.7 45 200 A/1101/16/P 50 FSB1128 18G 0.9/1.3 45/32 95 A/1101/18/P 50 FSB1129 20G 0.8/1.1 32 65 A/1101/20/P 50 FSB1130 22G 0.6/0.9 25 36 A/1101/22/P 50 FSB1131 24G 0.5/0.7 19 23 A/1101/24/P 50 FSB1132 26G 0.45/0.6 19 17 A/1101/26/F 50 Cannula Intravenous Non-Ported winged (straight) Safety FSB1133 14G 1.7/2.1 45 305 A/1104/14/P 50 FSB1134 16G 1.3/1.7 45 200 A/1104/16/P 50 FSB1135 18G 0.9/1.3 45/32 95 A/1104/18/P 50 FSB1136 20G 0.8/1.1 32 65 A/1104/20/P 50 FSB1137 22G 0.6/0.9 25 36 A/1104/22/P 50 FSB1138 24G 0.5/0.7 19 23 A/1104/24/P 50 FSB1139 26G 0.45/0.6 19 17 A/1104/26/F 50 SentraWin Safety: Non-Ported, Non-Winged Safety Cannula FSB1322 14G 1.7/2.1 45 305 A/1101/14/P 50 FSB1323 16G 1.3/1.7 45 200 A/1101/16/P 50 FSB1324 18G 0.9/1.3 45/32 95 A/1101/18/P 50 FSB1325 20G 0.8/1.1 32 65 A/1101/20/P 50 FSB1326 22G 0.6/0.9 25 36 A/1101/22/P 50 FSB1327 24G 0.5/0.7 19 23 A/1101/24/P 50 FSB1328 26G 0.45/0.6 19 17 A/1101/26/F 50 IV Cannulation Kit, without IV Safety Cannula comprising of; FSB1192 37003603-01 1 x 40 x 45cm non woven drape, 1 x microbore bi-fuse extension set 81 with 2 MicroClave connectors, 3 x non woven swabs 12ply 5 x 5cm, 1 x Clinell disposable wipe for medical devices, 1 x 3M 1633 IV dressing, 1 x Fannin insert label

Tipro TM -One Integrated safety I.V. Catheter for peripheral access Closed Safety system that offers protection from the risk of needle stick injuries and blood contamination during cannulation Integrated extension line with MicroClave Clear options Transparent flashback chamber for immediate detection of blood return Back cut needle point and catheter tip design to facilitate catheter insertion into the vein Polyurethane catheter with radio-opaque bands Soft, knurled wings that guarantee skin transplantation and optimise fixation of the device Tipro TM -One Integrated safety I.V. Catheter for peripheral access Size Description Catheter O.D. (mm) Catheter Length (mm) Supplier Codes Box Qty 26 Tipro TM -One Y connection with short extension 0.64 19 30190101 25 26 Tipro TM -One Y connection with short extension with MicroClave Clear 0.64 19 30190501 25 26 Tipro TM -One Y connection with short extension with 2 MicroClave Clear 0.64 19 30191301 25 26 Tipro TM -One Y connection 0.64 19 30195101 25 26 Tipro TM -One Y connection with MicroClave Clear 0.64 19 30195501 20 26 Tipro TM -One Y connection with 2 MicroClave Clear 0.64 19 30196301 25 24 Tipro TM -One Y connection 0.74 19 30282101 25 24 Tipro TM -One Y connection with MicroClave Clear 0.74 19 30282501 25 24 Tipro TM -One Y connection with 2 MicroClave Clear 0.74 19 30283301 25 22 Tipro TM -One Y connection 0.90 25 30382101 25 22 Tipro TM -One Y connection with MicroClave Clear 0.90 25 30382501 25 22 Tipro TM -Onee Y connection with 2 MicroClave Clear 0.90 25 30383301 25 20 Tipro TM -One Y connection 1.00 32 30482101 25 20 Tipro TM -One Y connection with MicroClave Clear 1.00 32 30482501 25 20 Tipro TM -One Y connection with 2 MicroClave Clear 1.00 32 30483301 25 18 Tipro TM -One Y connection 1.30 45 30585101 25 18 Tipro TM -One Y connection with MicroClave Clear 1.30 45 30585501 25 18 Tipro TM -One Y connection with 2 MicroClave Clear 1.30 45 30586301 25 16 Tipro TM -One Y connection 1.75 32 30782101 25 16 Tipro TM -One Y connection with MicroClave Clear 1.75 32 30782501 20 16 Tipro TM -One Y connection with 2 MicroClave Clear 1.75 32 30783301 25

MicroClave Clear Neutral Displacement Connector MicroClave s internal split septum internal fluid pathway fully blocks entry of any steel needle Closed system has three published studies with proven protection from passage of micro-organisms (1) Fully MRI compatible and Latex free 600 activations over 7 day period Transparent housing confirms flushing after blood draws Fully enforces needle free compliance 6 Supply Chain Product Code Description Box Qty Code Ref FSB1239 011-MC100 MicroClave connector clear transparent 100 FSB1272 011-MC3302 7 (18 cm) smallbore ext set w/microclave clear, clamp, rotating luer 50 FSB1273 011-MC3316 6 (15 cm) smallbore bifuse ext set w/2 MicroClave clear, 3 clamps, rotating luer 50 FSB1274 011-MC3323 6 (15 cm) smallbore trifuse ext set w/3 MicroClave clear, 4 clamps, rotating luer 50 FSB1275 011-MC33048 8 (20 cm) smallbore quad-fuse minibore extension set with 4 MicroClave clear connectors and rotating luer lock 50 FSB1266 011-C3300 MicroClave connector 100 FSC035 011-C3302 7 (18 cm) approx 0.29 ml, smallbore ext set w/microclave, clamp, rotating luer 50 FSC064 011-H1836 14 cm (5.5 ) approx 0.42 ml, smallbore bifuse ext set w/ 2 MicroClave and rotating luer lock 50 FSC043 011-H1747 15 cm (6 ) approx 0.63 ml, smallbore bifuse ext, 2 MicroClave w/green ring, 2 BCV, rotating luer 50 FSB1003 011-C3323 7 smallbore trifuse ext set w/3 MicroClave, 3 clamps, rotating luer 50 FSB1002 011-H1755 20 cm (8 ) smallbore quad-fuse minibore extension set with 4 MicroClave connectors and rotating luer lock 50 FSB1229 011-C3387 MicroClave connector with TPN label 100 FSB1299 011-H1210V Primary IV fluid infusion set with two MicroClave needle-free ports, 15µm filter, air vent, non-return valve, 261 cm tubing 25 FSB1300 60SRL01001 IV fluid infusion set with MicroClave needle-free port, 15µm filter, air vent, 198 cm tubing 50 FSB1303 011-H1910 4-Way stopcock with 2 MicroClave 50

Perouse PPS FLOW PLUS Safety Huber Needles and CT Port range Unique automatic positive pressure system provides automatic positive flush from catheter tip Allows one handed technique to remove needle and positive flush Sharps needle automatically protected in plastic cover on removal from port Transparent Huber dressings also available Reduction of the use of fibrinolytic agents (2) Supply Chain Ref Product Code Product description Box Qty FSY308 701511 Safety huber needle with connection line - usable length 15 mm 19G 12 FSY310 702011 Safety huber needle with connection line - usable length 20 mm 19G 12 FSY306 702511 Safety huber needle with connection line - usable length 25 mm 19G 12 FSY311 703011 Safety huber needle with connection line - usable length 30 mm 19G 12 FSY298 701509 Safety huber needle with connection line - usable length 15 mm 20G 12 FSY299 702009 Safety huber needle with connection line - usable length 20 mm 20G 12 FSY300 702509 Safety huber needle with connection line - usable length 25 mm 20G 12 FSY304 703009 Safety huber needle with connection line - usable length 30 mm 20G 12 FSY293 701507 Safety huber needle with connection line - usable length 15 mm 22G 12 FSY284 702007 Safety huber needle with connection line - usable length 20 mm 22G 12 FSY285 702507 Safety huber needle with connection line - usable length 25 mm 22G 12 FSY286 703007 Safety huber needle with connection line - usable length 30 mm 22G 12 FSY327 PF121401 Polyfilm dressing holding strips 12 x 14 cm 50

CS-51 and CH-61 Needle Free Spikes for reconstitution of glass drug vials Glass vial reconstitution spikes with integrated 0.22 & 0.2 Micron filters for single and multiple vial reconstitutions Avoids using steel sharps to reconstitute drugs from glass vials Supply Chain Ref Product Code Product description Box Qty FSB1280 011-CS-51 Vented dispensing pin with 0.2 micron filter, Clave 50 FSB1315 CH-61 50 ml vial adapter with 0.22 micron vent and Clave 50 CS-35 Filtered Straw for glass ampule fragments 5.0 micron filter to capture any glass fragments introduced to fluid during ampule snapping Avoids using steel sharps to reconstitute from glass ampule Internal 5.0 Micron Filter Supply Chain Ref Product Code Product description Box Qty FSB1282 011-CS-35 Clave ampule access straw minibore 50

CH-14 IV Solution bag spike for needle free closed connections, including Chemotherapy IV Bag spike to allow additions and syringe withdrawals Avoids use of steel sharps for IV bags or containers Compatible with Pump or Admin line infusions with connection to CH3034 in-line set Compatible with all Taxol Oncology with in-line pump infusion connection to H3161 Bolus Chemotherapy syringe closed Spiros cap-ch2000sc Supply Chain Ref Product Code Product description Box Qty FSB1285 011-CH-14 IV bag spike 50 FSB1278 CH3034 In-line infusion systems for attaching to volumetric pumps 50 FSB1284 011-H3161 In -line taxol filter Infusion systems for attaching to volumetric pumps 50 FSB1277 CH2000SC Spinning Spiros with cap 50

Total Needle free Solutions From Fannin Fannin - Creating Solutions Since 1829 References 1. Maragakis, et al (2006) Infection Control and Hospital Epidemiology. 27, (1)pp 67-70 Bouza, et al (2003) Journal of Hospital Infection. 54, pp 279-287 Yebenes, et al (2008), Critical Care Medicine. 36 (9) pp 2558-61 2. Lapalu J & al.,totally Implantable Port Management: Impact of positive pressure during needle withdrawal on catheter tip occlusion, Journal of Vascular Access, in press Fannin UK Ltd. 42-46 Booth Drive Park Farm South, Wellingborough Northamptonshire NN8 6GT Tel: +44 (0) 1189 305 111 enquiries@fannin.eu www.fannin.eu FANUK12-3480