Proportional pressure reducing valve, pilot operated

Similar documents
Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve, pilot operated

2-way proportional throttle valve for block installation

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional flow control valve, 2-way version

Supply pressure compensator, direct operated

Throttle and throttle check valve

Proportional pressure reducing valve, pilot operated

Pressure relief valve, pilot operated

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Pressure reducing valve, direct operated, with pressure monitoring

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure reducing valve, pilot operated

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Proportional pressure relief valve, directly operated, rising characteristic curve

4-way directional servo-valve

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

Check valve, pilot operated

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Meter-in pressure compensator, direct operated

2-way flow control valve

Check valve, pilot operated

Pressure relief valve, pilot operated

Twin throttle check valve

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Pressure relief valve, pilot operated

Proportional pressure reducing valve, in 3-way version

Directional servo-valve of 4-way design

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure reducing valve, direct operated

Pressure relief valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Proportional flow control valve, with integrated pressure compensator

Proportional pressure relief valve, pilot operated

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE)

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Directional servo-valve in 4-way design

Proportional pressure relief valve

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

2-way flow control valve

Check valve, pilot operated

Check valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure relief valve, pilot operated

3/2 directional spool valve, direct operated with solenoid actuation

Pressure sequence valve, direct operated

Proportional flow control valve, with inductive position transducer

Check valve, pilot operated

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Throttle and throttle check valve

2/2 directional seat valve, direct operated with solenoid actuation

3/2 and 4/2 directional poppet valve with solenoid actuation

Pressure sequence valve, direct operated

Double throttle check valve Type Z2FS 10

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Throttle and throttle check valve

3/2 and 4/2 directional seat valves with solenoid actuation

Bourdon tube pressure switch with infinitely variable switching pressure differential

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

Servo solenoid valves with on-board electronics (OBE)

Pressure relief valve, directly operated

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Bourdon tube pressure switch with infinitely variable switching pressure differential

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

Filling valve sandwich plate

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Check valve. Type S. Contents. Features. RE Edition: Replaces:

3/3 servo directional control valve with mechanical position feedback

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

Proportional directional valve, direct operated, with pq functionality

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Servo solenoid valves with electrical position feedback (Lvdt AC/AC)

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Transcription:

Proportional pressure reducing valve, pilot operated RE 29175/7.5 Replaces: 11.2 1/1 Types DRE and ZDRE Size 6 Component series 1X Maximum operating pressure 21 bar Maximum flow l/min H446 Table of contents Contents Page Features 1 Ordering code 2 Standard types 2 Symbols 2 Function, section 3 Technical data 4, 5 Control electronics 5 Electrical connection, cable socket 5 Characteristic curves 6, 7 Unit dimensions 8, 9 Features Pilot operated valve for the reduction of the pressures in ports A and P1, with pressure relief function Actuation by proportional solenoids For subplate mounting or sandwich plate design: Position of ports to DIN 2434, form A6 Subplates to data sheet RE 4552 (separate order, see pages 8 and 9) Low tolerances of the command value/pressure characteristic curve through electrical matching on the proportional solenoid Minimum set pressure of 2 bar in ports A or P1, see page 7 Control electronics: Analogue amplifier type VT-VSPA1(K)-1 in Euro-card format (separate order), see page 5 Digital amplifier type VT-VSPD-1 in Euro-card format (separate order), see page 5 Analogue amplifier of modular design, type VT 11132 (separate order), see page 5 Information on available spare parts: www.boschrexroth.com/spc

2/1 Bosch Rexroth AG Hydraulics DRE; ZDRE RE 29175/7.5 Ordering code DRE 6 1X M G24 K4 * Subplate mounting = No code Sandwich plate = Z Proportional pressure reducing valve = DRE Size 6 = 6 Pressure reduction in channel A (subplate mounting) = No code Pressure reduction in channel P1 (sandwich plate) = VP Position of cable socket (not with subplate mounting) Cable socket = 1 = 3 1) = 2 = 4 1) Further details in clear text Seal material M = NBR seals, suitable for mineral oil (HL, HLP) to DIN 51524 V = FKM seals Electrical connection K4 = Without cable socket, with component plug to DIN EN 1751-83 Cable socket separate order, see page 5 Supply voltage of control electronics G24 = 24 V DC M = Available only without check valve Pressure stage 5 = 5 bar 1 = 1 bar 21 = 21 bar 1X = Component series 1 to 19 (1 to 19: unchanged installation and connection dimensions) 1) Valve mounting surface (seal ring recesses in housing) Standard types Type DRE Type ZDRE Type Material no. Type Material no. DRE 6-1X/5MG24K4M R9954429 ZDRE 6 VP2-1X/5MG24K4M R9954431 DRE 6-1X/1MG24K4M R9932943 ZDRE 6 VP2-1X/1MG24K4M R99942 DRE 6-1X/21MG24K4M R9928873 ZDRE 6 VP2-1X/21MG24K4M R9915963 Symbols (for sandwich plate symbol: 1 = component side, 2 = plate side) Type DRE 6 Type ZDRE 6 VP A 1 P T P A 2 B T

RE 29175/7.5 DRE; ZDRE Hydraulics Bosch Rexroth AG 3/1 Function, section Valves of types DRE and ZDRE are electrically pilot operated 3-way pressure reducing valves with pressure relief function for the actuator. They are used to reduce a system pressure. Technical structure: The valve consists of three main assemblies: Pilot valve (1) Proportional solenoid (2) Main valve (3) with main spool (4) Function: Type DRE General function: Command value-related adjustment of the pressure to be reduced in channel A by means of pro por tio nal solenoid (2). When port P is pressureless, spring (18) holds main spool (4) in the initial position. This causes the connection from A to T to be opened, and that from P to A to be closed. Pressure connection from port P to ring channel (5). Pilot oil flows from bore (6) to port T, via flow controller (7), pilot valve (1) to orifice (8), throttling gap (9) to longitudinal groove (1) and bores (11, 12). Pressure reduction: Build-up of the pilot pressure in control chamber (17) as a function of the command value. Main spool (4) is shifted to the right, hydraulic fluid flows from P to A. The actuator pressure in port A acts via channel (13) and orifice (14) on spring chamber (15). An increase in pressure in port A to the pressure set on pilot valve (1) causes main spool (4) to be moved to the left. The pressure in port A becomes almost equal to the pressure set on pilot valve (1). Pressure relief function: When the pressure in port exceeds the pressure set on pilot valve (1), main spool (4) is pushed further to the left. This opens the connection between A and T and limits the pressure applied in port A to the set command value. Type ZDRE In principle, the function of this valve corresponds to that of type DRE 6. The pressure is, however, reduced in channel P1. 1 1 17 6 5 13 14 3 Type DRE 6-1X/ K4 B P 2 16 9 8 11 7 12 4 15 18 T A 1 1 17 6 P1 13 14 3 A1 B1 T1 Type ZDRE 6 VP1-1X/ K4 P2 T2 2 16 9 8 11 7 A2 12 B2 4 15 18

4/1 Bosch Rexroth AG Hydraulics DRE; ZDRE RE 29175/7.5 Technical data (for applications outside these parameters, please consult us!) General Weight DRE 6 kg 1.96 ZDRE 6 kg 1.9 Installation orientation Optional Storage temperature range C to + 8 Ambient temperature range C to + 7 Hydraulic (measured with HLP 46; ϑ oil = 4 C ± 5 C ) Max. operating pressure Port P or P2 bar 315 Ports P1, A and B bar 21 Port T bar Separately and at zero pressure to tank Max. set pressure Pressure stage 5 bar bar 5 in channel P1 and A Pressure stage 1 bar bar 1 Pressure stage 21 bar bar 21 Min. set pressure at command value in channels P1 and A bar See characteristic curves on page 7 Pilot oil flow l/min.65 Max. flow l/min Hydraulic fluid Mineral oil (HL, HLP) to DIN 51524 Further hydraulic fluids on enquiry! Max. permissible degree of contamination of the hydraulic fluid - cleanliness class to ISO 446 (c) Class /18/15 1) Hydraulic fluid temperature range C to + 8 Viscosity range mm 2 /s 15 to 38 Hysteresis % ± 2 of max. set pressure Repeatability % < ± 2 of max. set pressure Linearity % ± 3.5 of max. set pressure Manufacturing tolerance of command value/pressure characteristic curve, referred to hysteresis curve, rising pressure % ± 1.5 of max. set pressure Step response T u + T g (measured with static hydraulic fluid column between.2 and 5 litres) 1 % 9 % ms (without pressure overshoots) 9 % 1 % ms (without pressure overshoots) 1) The cleanliness classes specified for components must be adhered to in hydraulic systems. Effective filtration prevents malfunction and, at the same time, prolongs the service life of components. For the selection of filters, see data sheets RE 57, RE 576, RE 581, RE 586 and RE 588.

RE 29175/7.5 DRE; ZDRE Hydraulics Bosch Rexroth AG 5/1 Technical data (for applications outside these parameters, please consult us!) Electrical Supply voltage V 24 DC Min. control current ma 1 Max. control current ma 16 Solenoid coil resistance Cold value at C Ω 5 Max. hot value Ω 7.5 Duty cycle % 1 Electrical connection With component plug to DIN EN 1751-83 Cable socket to DIN EN 1751-83 2) Type of protection of the valve to EN 6529 IP 65 with cable socket mounted and locked Control electronics Amplifier in Euro-card format analogue VT-VSPA1(K)-1 to data sheet RE 111 (separate order) digital VT-VSPD-1 to data sheet RE 123 Amplifier of modular design (separate order) analogue VT 11132 to data sheet RE 29865 2) Separate order, see below Note: For details regarding environment simulation testing in the fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 29175-U (declaration on environmental compatibility). Electrical connection, cable socket (nominal dimensions in mm) Connection to component plug Connection to cable socket PE 1 2 PE 1 2 to amplifier Cable socket to DIN EN 1751-83 Separate order, stating material no. R911711 27,5 1A 25V 18 2 1 GDM 43 ~1 1 34,2 5,5 1 Fixing screw M3, tightening torque M T =.5 Nm

6/1 Bosch Rexroth AG Hydraulics DRE; ZDRE RE 29175/7.5 Characteristic curves (measured with HLP46, ϑ oil = 4 C ± 5 C) p-q V characteristic curves Pressure differential in bar DRE 6 ZDRE 6 P2 P1 1 5 1 15 25 Pressure differential in bar P2 P1 1 5 1 15 25 Note: The p value shown corresponds to the minimum pressure present in port P (P2) minus the maximum pressure to be controlled in port A (P1). Pressure differential in bar ZDRE 6 3 2 A1 A2 1 T1 T2 5 1 15 25 B1 B2 Pressure in port P1 or A in dependence upon the command value Pressure stage 5 bar 5 Pressure stage 1 bar 1 Pressure in P1 or A in bar 4 1 Pressure in P1 or A in bar 8 6 4 4 6 8 Command value in % 1 4 6 8 Command value in % 1 Pressure stage 21 bar 21 Pressure in P1 or A in bar 16 1 8 4 4 6 8 Command value in % 1

RE 29175/7.5 DRE; ZDRE Hydraulics Bosch Rexroth AG 7/1 Characteristic curves (measured with HLP46, ϑ oil = 4 C ± 5 C) Min. set pressure in port P1 or A at -V command value (without backpressure in channel T or T1) Pressure stage 5 bar Pressure stage 1 bar/ 21 bar 1 1 Min. set pressure in bar 8 6 4 2 Min. set pressure in bar 8 6 4 2 1 1 DRE 6 A T DRE 6 P A ZDRE 6 P1 T2 ZDRE 6 P2 P1 1 1 DRE 6 A T DRE 6 P A ZDRE 6 P1 T2 ZDRE 6 P2 P1 Pressure in channel P1 or A flow Pressure stage 5 bar Pressure stage 1 bar Pressure in channel P1 or A in bar 5 4 1 1 1 1 DRE 6 A T DRE 6 P A ZDRE 6 P1 T2 ZDRE 6 P2 P1 Pressure in channel P1 or A in bar 8 6 4 1 1 DRE 6 A T DRE 6 P A ZDRE 6 P1 T2 ZDRE 6 P2 P1 Pressure stage 21 bar Pressure in channel P1 or A in bar 21 16 1 8 4 1 1 DRE 6 A T DRE 6 P A ZDRE 6 P1 T2 ZDRE 6 P2 P1

8/1 Bosch Rexroth AG Hydraulics DRE; ZDRE RE 29175/7.5 Unit dimensions: Type DRE 6 (nominal dimensions in mm) 5 6 max. 2 max. 8 15 8 84,5 Ø 1 4 x Ø 5,4 H13 Ø 32 1,3 +,1 4,3 5 83,5 Ø 12,3 +,1 A B 1 3 4 2 9 7 4,5±,1 16,5 +,5 T 39,5,75±,1 44,5-1 35 1 Proportional solenoid 2 Nameplate 3 Valve housing 4 Identical seal rings for ports A, B, P and T 5 Cable socket, separate order, see page 5 6 Space required to remove cable socket 7 Position of ports to DIN 2434; form A6 8 Hexagon A/F 36 (across corners Ø39 mm) 9 Hexagon A/F 24 31±,1 A B P 19±,1 27,8±,1,1/1mm Rzmax 4 1,3±,1 26 5,95±,1 16,25±,1 26,55±,1 Required surface quality of mating part 31,75±,1 Subplates to data sheet RE 4552 and valve fixing screws must be ordered separately. Subplates: G 341/1 (G 1/4) G 342/1 (G 3/8) G 52/1 (G 1/2) Valve fixing screws: 4 off M5 x 5 DIN 912-1.9; tightening torque M T = 7 Nm Tolerances to: General tolerances ISO 2768-mK

RE 29175/7.5 DRE; ZDRE Hydraulics Bosch Rexroth AG 9/1 Unit dimensions: Type ZDRE 6 (nominal dimensions in mm) 5 6 max. 2 max. 8 15 83,5 8 4 x Ø 7,5 84,5 4 x Ø 5,4 H13 1,3 +,1 4 -,3 Ø 12,3 +,1 A2 B2 1 3 4 2 9 44,5-1 15 35 15 15 7 31±,1 A1 4,5±,1,5 +,5 8 T1 B1 P1 1,3±,1 19±,1 27,8±,1 26 5,95±,1 16,25±,1 26,55±,1,75±,1 31,75±,1 35,1/1mm 1 Proportional solenoid 2 Nameplate 3 Valve housing 4 Identical seal rings for ports A2, B2, P2 and T2 5 Cable socket, separate order, see page 5 6 Space required to remove cable socket 7 Position of ports to DIN 2434; form A6 8 Hexagon A/F 36 (across corners Ø39 mm) 9 Hexagon A/F 24 Rzmax 4 Required surface quality of mating part Tolerances to: General tolerances ISO 2768-mK Subplates to data sheet RE 4552 and valve fixing screws must be ordered separately. Subplates: G 341/1 (G 1/4) G 342/1 (G 3/8) G 52/1 (G 1/2) Valve fixing screws: 4 off M5 DIN 912-1.9; tightening torque M T = 7 Nm

1/1 Bosch Rexroth AG Hydraulics DRE; ZDRE RE 29175/7.5 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 () 93 52 / 18- Fax +49 () 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 29175/7.5 DRE; ZDRE Hydraulics Bosch Rexroth AG 11/1 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 () 93 52 / 18- Fax +49 () 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

12/1 Bosch Rexroth AG Hydraulics DRE; ZDRE RE 29175/7.5 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 () 93 52 / 18- Fax +49 () 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.