BMRX Series Rotary Level Indicator

Similar documents
TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

BMRX Series ROTARY LEVEL CONTROL

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

PRO REMOTE Series CAPACITANCE PROBE

CVR-625. Compact Vibrating Rod Instruction Manual

PRO REMOTE 25 LV CAPACITANCE PROBE

ROTARY Point Level Measurement for Inventory Control

Installation, Operation & Maintenance Instructions

TS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

TABLE OF CONTENTS SPECIFICATIONS...3 SAFETY SUMMARY...4 INTRODUCTION...5, 6 INSTALLATION...7, 8, 9, 10 TESTING THE REMOTE OPERATION AIR PURGE...

Diaphragm Switch BM65

BinMaster Price Book

Mini-Roto TM Paddle Wheel Installation & Operation Manual

PROCAP Capacitance Level Sensors

ASG-2000 SiloGauge Remote Unit

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

P U L S A R point 210

PROCAP Capacitance Level Sensors

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Roto-Bin-Dicator PRO Installation & Operation Manual

Models CMXC-SB, PMXC-SB, and WMXC Series Installation Manual for Optional Fixture Mounts

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

DIAMOND POINT VIBRATING PROBES

RF Point Level Control with Sensor Monitor

STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Service Instructions. Models: SLC-B & SXLC-B Hopper Level Control

Cryotrol Temperature Controller Instruction and Operation Manual

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Super-Safe-Plus Roto-Bin-Dicator

SPC-PANEL Simplex, Single Phase Pump Control Panel

Rental Industry Safety Tester Safe Check 5s

PT-500 Analog Output Series User Manual

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Rotary Paddle Bin Monitor MODEL KA & KAX

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Air Curtain. Installation, Operating and Maintenance Instructions

Operating Instructions Type MPT 53

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

J 6 Se r i e s. Pressure and Vacuum switches. features

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

STC 2L Series Solenoid Valves

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS


MaxLite LED UTILITY WRAP FIXTURES

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

SMP3CTX Series Power Supply/Charger

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

362 Clamp Meter. Users Manual

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

ILED Aquarius Illuminated Windsock. User Manual

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

CAUTION CM-SE CM-S21 CM-S41

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

MAXIGARD A2000 SPEED SWITCH. Introduction

i3000s/i2000 Flex AC Current Probe

Product Information. 16 Series ROSS CONTROLS

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Users Manual. Phase Rotation Indicator

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

3V SERIES SOLENOID VALVE

Pump Installation and Service Manual HRS Hydromatic Retractable System

37SCENE 46SCENE 79SCENE

AS-57FMH Flush Mount Kit AS-57EBDBP

INSTALLATION GUIDE. Universal System for Zero Turn Mowers

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

OWNER'S MANUAL WALL MOUNTED ELECTRIC PATIO HEATER MODEL#HLI-1531 ATTACH YOUR RECEIPT HERE

Quick Connection Panel (QCP) Installation Guide

ESE Series Cast Iron Sewage Pumps

FUNNEL CAKE FRYER Instruction Manual Models: 8078 / FC-4, 8082 / FC-6, and 8090 / FC-4

STC 2W Series Solenoid Valves

Cable Length Meter INSTRUCTION MANUAL

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Waterproof 4X Telephone Model WP80

INSTALLATION & OWNER'S MANUAL

Two Motor Tandem. Installation Instructions. for Model 108 F LEX-AUGER Feed Delivery Systems. Model 108 Two Motor Tandem Installation Instruction

Transcription:

BMRX Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION... 5 2.1 Location and Mounting... 5 2.2 Input Power and Field Wiring... 6 2.3 Grounding... 6 3.0 DPDT RELAY... 7 3.1 Fail-Safe High... 7 3.2 Fail-Safe Low... 7 4.0 WARRANTY AND CUSTOMER SERVICE... 8 5.0 DISPOSAL... 8 EUROPEAN DECLARATION OF CONFORMITY... 9

BMRX GENERAL SPECIFICATIONS SPECIFICATIONS Supply: AC MODELS 24 VAC, 115 VAC, or 230 VAC 50/60 Hz DC MODELS 12 VDC or 24 VDC Supply Tolerance: -15% +10% Load: Ambient Temperature: (Electronics) AC Model = 5.5 VA; DC Models = 1 VA -40 F to +158 F (-40 C to +70 C) Enclosure: Type 4X, 5, 7, 9, & 12 (Hazardous Location Class I, Groups C & D / Class II, Groups E, F & G) DPDT Relay Output: Fail-Safe: Mounting: Conduit Entry: Shaft Seal: Enclosure: 10 Amps 250 VAC Switch selectable High or Low level modes 1-1/4 NPT 3/4 NPT 1/2 micron, 30 PSI Die cast aluminum, FDA recognized powder coat finish 927-0252 Rev C 0812

SAFETY SUMMARY SAFETY Review the following safety precautions to avoid injury and prevent damage to the equipment. The product should be installed, commissioned, and maintained by qualified and authorized personnel only. Install according to installation instructions and comply with all National and Local codes. Use electrical wire that is sized and rated for the maximum voltage and current of the application. Properly ground the enclosure to an adequate earth ground. Observe all terminal and relay contact ratings as called out on the nameplate and in the installation manual. Ensure that the enclosure cover is in place and secured tightly during normal operation. In potentially wet environments thoroughly seal all conduit entries. If this product is used in a manner not specified by the manufacturer, the safety protection could be compromised. Safety Terms and Symbols WARNING: Warning statements identify conditions or practices that could result in injury or loss of life. Risk of electrical shock. CAUTION: Caution statements identify conditions or practices that could result in damage to this product or other property.

1.0 INTRODUCTION INTRODUCTION The BinMaster BMRX is a rotating paddle style level sensor which provides reliable point level detection for bulk solids, including powder, pellet, and granular materials. The unit has a switch selectable fail-safe relay that will fall to a "safe" condition in the event of a power failure. The BMRX motor rotates the drive shaft and paddle at 1 RPM ( 2 RPM on 24 VDC Model). When the vessel material fills to the level of the indicator paddle, the material causes the paddle to stop rotating indicating a covered condition. When the material falls away, the paddle starts rotating again to indicate an uncovered condition. 2.0 INSTALLATION 2.1 Location and Mounting Figure 1 TOP MOUNT (For mounting plate options see Figure 4 on page 6) 1. Locate and cut hole in top of bin to fit outside diameter of 1-1/4 pipe coupling (1.950 ). 2. Position coupling halfway into bin and weld. 3. Turn unit so conduit opening is in desired location. 4. Add 1/4 extension pipe to desired length with standard 1/4 coupling on bottom end. 5. Cut 1-1 /4 support pipe approximately 4 shorter than overall length of 1/4 pipe shaft when used with flexible coupling. 6. Insert 1-1/4 pipe into coupling and tighten. 7. Insert paddle into 1/4 coupling and drill holes for lock pins. SIDE MOUNT (For mounting plate options see Figure 5 on page 6) 1. Locate and cut hole in side of bin to fit outside diameter of 1-1/4 pipe coupling. 2. Weld on half of standard 1-1/4 pipe coupling to bin wall flush with inside of bin. 3. Insert hub into coupling and turn until conduit opening is in blown position. 4. Screw paddle into place and replace lock pin. 5. Shaft and paddle should be shielded in low level mounting when subjected to material flow. 6. For side mount, a solid coupler is recommended. Figure 2 927-0252 Rev C 0812

MOUNTING PLATES Mounting plates are necessary when a completely assembled unit is to be mounted on the bin wall from the outside. A 5-1/2 hole is cut in the bin. Six bolt holes are drilled around the hole to match the mounting plate. The plate, with the unit attached, is then bolted in place. All mounting plates are available in carbon and stainless steel. For use with all rotary level controls. This model is used for top of bin installations where shaft extensions and shaft guards are required. BMRX Wiring 2.2 Input Power and Field Wiring For use with all rotary level controls. This model is used primarily for side of bin installations. Figure 4 Figure 5 Full Coupling Mounting Plate Half Coupling Mounting Plate The BMRX is available in AC and DC Models. The AC Models are available to be powered from 24 VAC, 115 VAC, or 230 VAC 50/60 Hz supply voltages. The DC Models are available to be powered from 12 VDC or 24 VDC supply voltages. See the voltage rating on the nameplate for the appropriate supply voltage. Field wiring should conform to all national and local electrical codes and any other agency or authority having jurisdiction over the installation. For power input, use wire that is sized and rated for the maximum voltage and current as per equipment ratings and has a temperature rating of at least 70 C. For relay outputs, use wire that is sized and rated for the maximum voltage and current as per application, up to 250 VAC 10A, and has a temperature rating of at least 70 C. Installation shall be done by qualified personnel. Input Power Power input to the BMRX is connected to the LINE terminals labelled L and N. AC Models On AC models if one of the conductors is grounded, it should be connected to the N terminals. The ungrounded conductor should be connected to the L terminal. If neither conductor is grounded then one of them is connected to the N terminal and the other to the L terminal. FAIL SAFE SWITCH POSITION HIGH LOW RELAY CONDITION PADDLE CONDITION UNCOVERED COVERED ENERGIZED DE-ENERGIZED DE-ENERGIZED ENERGIZED CONTACT POSITION WHEN RELAY IS DE-ENERGIZED Figure 6 DC Models On DC models the negative conductor should be connected to the N terminal and the positive conductor should be connected to the L terminal. POWER IN -- LINE or (+) on DC Models POWER IN -- NEUTRAL / LINE or (-) on DC Models GROUND

2.3 Grounding An equipment grounding connection (earth ground) must be supplied to the unit for safety. Connect the ground conductor to the green equipment grounding screw identified in the enclosure. 3.0 DPDT RELAY The DPDT relay utilizes a Fail-Safe selector switch. There are 2 positions for this switch, High (H) and Low (L). A Fail-Safe condition means that the DPDT relay contact positions are set up so that in the event of a power failure the relay will be de-energized and the contacts will indicate a condition that is deemed safe for the application. 3.1 Fail-Safe High Fail-Safe High means that the relay will be energized when the paddle is rotating (uncovered) and will de-energize when the probe is covered. In this mode, a power failure will cause the relay contacts to indicate that the paddle is covered, whether it is or not. FAIL-SAFE HIGH RELAY CONTACT POSITION Figure 7 UNCOVERED COVERED 1 1 1 2 2 2 NC C NO NO C NC 1 1 1 2 2 2 NC C NO NO C NC 3.2 Fail-Safe Low Fail-Safe Low means that the relay will be de-energized when the paddle is rotating (uncovered) and will energize when the paddle is covered. In this mode, a power failure will cause the relay contacts to indicate that the paddle is uncovered whether it is or not. FAIL-SAFE LOW RELAY CONTACT POSITION Figure 8 UNCOVERED COVERED 1 1 1 2 2 2 NC C NO NO C NC 1 1 1 2 2 2 NC C NO NO C NC 927-0252 Rev C 0812

4.0 WARRANTY AND CUSTOMER SERVICE 4.1 Limited Warranty The manufacturer warrants this equipment for two (2) years according to the following terms: 1. This warranty extends to the original purchaser only and commences on the date of original purchase. The original purchaser must mail to the manufacturer the "Warranty Registration" card to confirm the equipment purchase. Failure to do so may void the warranty. 2. The manufacturer will repair or replace any part of this equipment found to be defective, provided such part is delivered prepaid, to the factory. Manufacturer's obligation is limited to the cost of material and labor to repair or replace and does not include transportation expenses. 3. This warranty shall not apply to any product that has, in our judgment, been tampered with, altered, subject to misuse, neglect or accident. In addition, the warranty does not extend to repairs made necessary by normal wear. 4. This warranty is in lieu of all other warranties, expressed or implied. 4.2 Customer Service BinMaster offers a toll-free Customer Service phone number 1-800-278-4241. You may call the Customer Service Department for technical and application assistance Monday through Friday from 8:00 AM to 5:00 PM Central Time. International customers call us at (402) 434-9102 or reach us via fax at (402) 434-9133. 5.0 DISPOSAL This product consists of materials that can be recycled by specialized recycling companies. It uses recyclable materials and the electronics are designed to be easily separated. Consult local authorities for proper disposal locations.

Declaration of Conformity BinMaster Level Controls 7201 North 98th Street Lincoln, NE 68507-9741 Phone: 402-434-9100, Fax: 402-434-9133 BinMaster declares that all models of the BMRX level control devices as listed below comply with the following directives and harmonized standards. This product if installed, operated and maintained as described in this manual will provide a safe and reliable point level control device for bulk solid materials. Low Voltage Directive 73/23/EEC Standard IEC 61010-1:2001 Product: Rotary point level control device Models: BMRX AC Models 24 VAC, 115 VAC, and 230 VAC; DC Models 12 VDC and 24 VDC All test reports and documentation are held and can be obtained from BinMaster. Manufacturing Location: Lincoln, Nebraska, USA Scott McLain President 3/25/2008 927-0252 Rev C 0812

Mounting Instructions Always mount unit with conduit opening down Conduit Seal When installing this level indicator in environments where it is possible for moisture or moist air to enter the enclosure through the electrical conduit, the conduit opening should be sealed with a duct seal compound or putty appropriate for the purpose. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com