RAE PowerPak User s Guide

Similar documents
User Guide. RAE PowerPak

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

Twelve Unit Rapid Charger

Atex Range Designed for used for oil gas, petrochemical, aviation, marine, mining and utility applications.

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

ATEX II 2G Ex ib IIC T4 Gb. ATEX II 2D Ex ib IIIC T150 C Db ATEXBEAM

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

EX Series User Manual

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Single Unit Rapid Charger FOR RECHARGEABLE TWO-WAY RADIO BATTERIES

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

HOVERTRAX 2.0 HOVERTRAX DLX 2.0 REPLACEMENT BATTERY PACK KIT

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

Safety Instructions Proline Promass 300

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

Dräger X-am 5100 Single-Gas Detection Device

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

FieldView External Charger. User Guide

BatteryChargers. Quick Start Guide AA RECHARGER POWERCHARGER

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1

Operating Instructions

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

PowerPlex 40V MAX Standard Battery Pack/Charger

INSTRUCTION MANUAL (ATEX / IECEx)

Holville I.S. Uninterruptible Power Supply Unit (UPS)

Certificate of Compliance

Spotlight 1,000,000 Power Series Cordless Rechargeable

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Wolflite XT Rechargeable LED Handlamp

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Assembly. Trunk IN + - S U, I U, I. Spur 1

SCHISCHEK REDBIN-D TRANSMITTER

Sensor boxes SRBE Key features and product range overview

Model 8800C Vortex Flowmeter

Language specific user manuals are available on

IECEx Certificate of Conformity

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

The use of batteries in hazardous areas. 1. Type of batteries and technical evolution. March 2018

Owner s Manual and Assembly Instructions

OPERATION AND MAINTENANCE INSTRUCTIONS

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Ex e, ia Junction boxes TNCN. Features

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

Certificate of Compliance

CHARGING INSTALL THE BATTERIES INTO THE CONTROLLER

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

INSTRUCTION MANUAL (ATEX / IECEx)

OM004, OM006 & OM008 Oval Gear Meter

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

Features. Flexibility

ACROBAT SWING STAND MODEL

Model 3051 Sensor Module Replacement

Smart Valve Positioner 700 Series with HART Communication Protocol

OPW Fluid Transfer Group Europe BV

Fisher i2p 100 Electro Pneumatic Transducer

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

Intelligent NiMH/NiCd/Li-ion Charger TN456

Compact temperature switch Model TCS

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

ATEX FLASHLIGHT HL10 EX

Solenoid Valves Type 3963

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

CYCLOPS Y Purge Indicator

WARNING! READ BEFORE INSTALLATION

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc.

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Bubble Machine. User Manual

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

Bubble King. User Manual

Dräger X-am Pump External pump for multi-gas detectors

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

EG Series Installation Manual

FB1100/FB1200 Flow Computer Battery Field Replacement Guide

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

707Ex. Users Manual. ma Calibrator

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

CYCLOPS Z Purge Indicator

Solar Charge Controller

SCC-MPPT Solar Charge Controller

Terminal Boxes Series 8125

Smart Valve Positioner 700 Series with HART Communication Protocol

RPX Repeater Li-Ion Battery Frame

NANO HERCULES ITEM NO INSTRUCTION MANUAL 3.5 CHANNEL IR HELICOPTER AGES 8+

Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY

c-go 24V/6A 24V/8A 24V/12A

Transcription:

RAE PowerPak User s Guide \\\\\ Rev. A July 2009 P/N F03-4001-000

Copyright 2009 RAE Systems, Inc. Ordering Replacement Parts: If you need replacement parts, a list is available online: http://www.raesystems.com

Contents 1 Safety Instructions... 4 1.1 RAE PowerPak Marking... 5 1.2 Operation Area and Conditions... 6 1.3 Instruction For Safe Use... 6 1.4 Use In Hazardous Areas... 7 2 Standard Kit... 8 3 General Information... 8 4 Key Features... 9 5 Physical Description... 10 6 LCD & LED... 11 7 LED Status Indicator... 11 8 LCD Status Information & Error Messages... 12 9 Installation... 14 10 Operation Instructions... 17 11 Connection... 18 12 Changing The RAE PowerPak... 21 13 Charging The RAE PowerPak... 24 14 Troubleshooting & Repair... 27 14.1 Encapsulated Internal Battery Replacement... 27 14.2 Batteries And Proper Battery Disposal... 31 15 Specifications... 32 Appendix A: Controlled Part Of RAE PowerPak (FTB1000) Manual... 33 3

1 Safety Instructions WARNINGS Warning: This instrument has not been tested in an explosive gas/air atmosphere having an oxygen concentration greater than 21%. Substitution of components may impair suitability for intrinsic safety. Replace encapsulated internal batteries only in nonhazardous locations. Warning: Charging of the FTB 1000 by means of mains charger can only be done in safe area and only with RAE Systems Charger P/N F03-3012-000. Warning: The internal encapsulated battery units can only be exchanged with the original RAE Systems battery. 4

1.1 RAE PowerPak Marking The RAE PowerPak is certified according to the IECEx scheme, ATEX and CSA for US and Canada as protected by intrinsic safety. The product is marked with the following information: RAE PowerPak Type FTB1000. Serial No/barcode: F032XXXXXX IECEx DNV 09.0003X Ex ia I/IIC T4 0575 IM1/II 1G Ex ia I/IIC T4 DNV 09 ATEX 55726X Li: 0.1 µh ; Ci: 0.1 µf ; Ui: 10 V Ii : 3.33 A; Pi: 8.8 W; Um: 11V; Lo: 3.4 µh; Co: 100 µf; Uo : 3.6 V Io: 3.2A; Po: 3.1 W; Lo/Ro: 20.6µH/Ω Cl.I Dv 1, Group A,B,C,D T4 Only as to intrinsic safety for use in hazardous loc. Intrinsically safe/ Securite Intrinseque/Exia -40º C < Tamb < +55º C Warning: Read User s Manual for Intrinsic Safety Precautions 5

1.2 Operation Area and Conditions Hazardous Areas classified by Zones RAE PowerPak is intended to be used in mines susceptible to firedamp or hazardous areas classified for zone 0, zone 1 or zone 2, within the temperature range of -40º C to +55º C, where gases of explosion groups IIA, IIB or IIC and T4 may be present. Hazardous Areas classified by Divisions RAE PowerPak is intended to be used in hazardous areas classified for Class I Div. 1 or 2, within the temperature range of -40º C to +55º C, where gases of explosion groups A, B, C or D and temperature class T4 may be present. 1.3 Instruction For Safe Use Strictly follow the instructions for safe use. Application of the RAE PowerPak requires full understanding and strict observation of the instructions. The RAE PowerPak can be charged in hazardous areas by a charger complying with the intrinsically safe input entity parameters. The RAEPowerPak can be charged outside hazardous areas by a charger complying with the Um parameter. The internal encapsulated battery units can only be exchanged with the original RAE Systems battery, Part Number: F03-3002-000, in a safe area or with a "hot zone" permit. The RAEPowerPak can be connected and disconnected inside the hazardous area. 6

1.4 Use In Hazardous Areas Equipment which is intended for use in explosive atmospheres and which has been assessed and certified according to international regulations may be used only under specified conditions. The components may not be modified in any way. The appropriate regulations for service and repair must be properly observed during such activities. FCC Part 15 statement and CE This device complies with Part15 class B of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 7

2 Standard Kit RAE PowerPak (FTB1000), as specified with two or four encapsulated internal batteries. Cable for connecting MeshGuard to RAE PowerPak: D01-3003-000 3 General Information The RAE PowerPak (FTB-1000) is an intrinsically safe rechargeable battery power source for use with a MeshGuard EC or MeshGuard LEL monitor or MeshGuard Router or any other equipment with matching entity parameters. MeshGuard LEL and RAE PowerPak 8

4 Key Features RAE PowerPak User s Guide Up to 4 months continuous operation before recharging, when it contains four encapsulated internal batteries and is used with a MeshGuard (4 months), MeshGuard LEL (25 days), or MeshGuard Router (1.5 months) Rugged stainless-steel enclosure Very low-cost installation no hardwiring involved Very little maintenance or monitoring Large, easy-to-read continuous display of power percentage and charging/error messages Bright 3-color status LED Simple operation without switches or controls IP-65 rated for outdoor use in harsh environments Unit can be replaced in hazardous location 9

5 Physical Description Front View 1 2 3 4 5 Bottom View 6 8 7 9 1 Carrying handle 2 Stainless steel enclosure 3 Status LED 4 Status LCD 5 Protective bezel for connections 6 Power output port to MeshGuard 7 Power output dust cap 8 Power input from charger 9 Power input dust cap 10

6 LCD & LED RAE PowerPak User s Guide The RAE PowerPak has a single LED and an LCD that indicates charge, and in the case of errors any messages. 3-color LED LCD 7 LED Status Indicator The LED glows red, orange, or green, depending on different status alerts it is conveying. Color Indication Related LCD Message Green Red Orange Battery (or batteries) fully charged. Battery (or batteries) charging. Indicates an error. Check the LCD for more information. LCD says FULL LCD says CHRG (charging) LCD shows error code beginning with the letters Er followed by two digits indicating the type of error. 11

8 LCD Status Information & Error Messages Error codes may appear in the LCD, indicating battery or fuse conditions, as well as temperatures outside the normal operating range. Error Code Message Er01 Battery 1 voltage too low Er02 Battery 2 voltage too low Er03 Battery 3 voltage too low Er04 Battery 4 voltage too low Er05 Battery 1 voltage too high Er06 Battery 2 voltage too high Er07 Battery 3 voltage too high Er08 Battery 4 voltage too high Er09 Battery 1 temperature too low Er10 Battery 2 temperature too low Er11 Battery 3 temperature too low Er12 Battery 4 temperature too low Er13 Wrong battery type Er14 Wrong charger Er15 Fuse break Error Code Er01 to Er04: Er05 to Er08: Er09 to Er12: Explanation & Solution The battery is not charging to full capacity. It may need to be replaced. The battery is overcharging, but does not send too much power to the MeshGuard, since it has overvoltage protection. The battery is being charged in a location where the temperature is below 0º C (32º F), and therefore is charging slowly. The only problem this presents is that the battery cannot be fast-charged. 12

Er13: Er14: Er15: RAE PowerPak User s Guide The wrong type of battery has been placed in one of the four slots. Replace it with the correct type. The wrong type of charger is being used. The correct RAE Systems charger (part number F03-3014-000) identifies itself to the RAE PowerPak. An internal fuse has been blown. Fuses on the main circuit board cannot be replaced. The main circuit board must be replaced. Contact RAE Systems service. The number of batteries is indicated by the number of segments showing in the left side of the display. 1 2 3 4 These segments correspond to the battery locations (the enclosure is shown with its front cover removed): 2 4 3 1 Note: The percentage of battery charge is relative to the capacity of the entire number of batteries. If there is one battery and the reading is 75%, that means 75% of the one battery s capacity. If there are multiple batteries, 75% means 75% of the total combined capacity. Always refer to the number of segments indicating the total number of batteries. 13

9 Installation RAE PowerPak User s Guide The RAE PowerPak is designed to be located close to a detector such as a MeshGuard, MeshGuard LEL or MeshGuard Router. To accommodate this, and to ensure security, both are mounted on a steel plate, which can be attached to a wall or other flat vertical surface. Before attaching the steel plate to a surface, you should attach the metal enclosure for the MeshGuard to the plate. 1. Place the MeshGuard in the steel enclosure. 2. Turn the plate and MeshGuard over. 3. Line up the hole on the back of the MeshGuard with the hole on the plate. 4. Insert an M4x10 screw through a flat washer and locking washer, and tighten the MeshGuard s steel enclosure to the plate. Front view Rear view Align the holes 14 Insert screw through flat and locking washers and secure

Secure the plate to a wall or other solid, flat surface by using M8- size screws with flat washers and locking washers, following this diagram. At a minimum, use four screws at the corners. (The MeshGuard has been removed from the drawing for simplicity.) 15

Next mount the RAE PowerPak onto the steel plate. Note: Make sure the RAE PowerPak has been fully charged before installation. Align the RAE PowerPak with the rails on the metal plate Slide the RAE PowerPak down until it stops Use the latch to lock the RAE PowerPak in place: Flip the latch down to the horizontal position 16 Turn the screw until it is finger-tight do not overtighten or use tools

10 Operation Instructions The FTB 1000 Power Pack is only to be used with RAE Systems products whose entity parameters match the entity parameters of the RAE PowerPak. Input Output Fig. 1 Connections Fig. 2 RAE PowerPak connected to the MeshGuard. The RAE PowerPak can be connected and disconnected inside the hazardous area. 17

11 Connection RAE PowerPak User s Guide Note: The following steps must be performed outside the hazardous area or with a hot zone permit. Now connect the cable between the RAE PowerPak and the MeshGuard. With the MeshGuard or MeshGuard LEL securely in its housing, you can remove the cover over the battery compartment so that you can replace the internal battery in the MeshGuard. Use the sensor and battery removal tool as shown. Sensor and battery removal tool (P/N 019-2044-000) The connector from the RAE PowerPak screws into the MeshGuard s battery compartment. Bottom views of the MeshGuard in its steel enclosure are shown in the procedure below. 1. Remove battery cover with the 3-pin end of the sensor and battery removal tool by turning counterclockwise. Power end of cable 2. Lift off the cover. 3. Insert the power end of the cable connected to the Power Pack. 18

Cord to RAE Power Pack 4. Use the open hex end of the wrench, and with both pins mated with the two holes on the power end, tighten by turning clockwise until it is snug. Do not overtighten. On the bottom of the RAE PowerPak are two dust caps that are screwed onto the connectors: Unscrew the one on the left by turning it counterclockwise. When it is removed, you see the four pins of the connector. 19

Screw the end of the connecting cable to the port on the bottom of the RAE PowerPak. Do not use tools or overtighten. 20

12 Changing The RAE PowerPak 1. Unscrew the battery connector from the RAE PowerPak. 2. Loosen the safety screw holding the battery latch. 21

3. Raise the latch. RAE PowerPak User s Guide 4. Lift up the battery and slide it off the steel plate. 22

5. Mount a fully charged RAE PowerPak on the mounting bracket. 6. Flip the latch down. 7. Tighten the safety screw. 23

8. Connect the Meshguard LEL to the battery. 9. Turn on the MeshGuard LEL. 13 Charging The RAE PowerPak Before using the RAE PowerPak and whenever the RAE PowerPak shows a low-power reading (10% or less), you should charge it in a safe location. 1. If the RAE PowerPak is currently in service and is attached to a MeshGuard, follow the instructions for removing it, on page 21. 2. Remove the cap over the charging port on the bottom of the RAE PowerPak by unscrewing it. 24

3. In a safe location, connect the charging cable between the RAE PowerPak and the Charger and connect the AC mains cord from the Charger to an AC power plug. 4. The LED above the display should glow red and the display should say CHRG. If not, check your connections and the AC outlet. 5. When the RAE PowerPak is fully charged, the LED glows green and the display says Full. 6. Disconnect the AC mains cord from the AC power outlet. 25

7. Disconnect the Charger from the RAE PowerPak. 8. Screw the cap back on over the charging port on the bottom of the RAE PowerPak. 9. Place the RAE PowerPak on the steel mounting plate (detailed instructions are shown on page 14). 10. Follow the insructions on page 17 to reconnect the RAE PowerPak to the MeshGuard. 26

14 Troubleshooting & Repair The RAE PowerPak is designed to be trouble-free and require no maintenance. However, if you see the status LED glow orange and an error message in the display, refer to the error message table on page 12 and take the suggested action. 14.1 Encapsulated Internal Battery Replacement In the unlikely event that one of the encapsulated internal batteries needs replacement, it is easy to replace them in the RAE PowerPak. Follow these steps, and only replace an encapsulated internal battery with a RAE Systems model with the same part number (F03-3002-000). WARNING! Only open the RAE PowerPak enclosure and change or charge encapsulated internal batteries in a non-hazardous location or with a hot zone permit. 27

1. Unscrew the four screws on the front of the enclosure. 2. Disconnect the battery s power jumper from the main printed circuit board. 28

3. Remove the screws at both ends of the battery. These attach the bracket that holds the battery in place. 4. Lift out the bracket and the battery. 29

5. Insert a new battery and the bracket into the enclosure. 6. Replace the two screws and tighten them with a screwdriver. Before replacing the front cover, check the display. If it is not working, then the ribbon cable between the display and the main circuit board might have become disconnected. Make sure it is firmly connected to the printed circuit board and to the display module. 30

The display should indicate the correct number of batteries. If not, check that the connector between the battery and the circuit board is firmly connected. 7. Once everything checks out, replace the front cover and tighten the screws. 14.2 Batteries And Proper Battery Disposal This product may contain one or more sealed lead-acid, nickelcadmium (NiCd), nickel-metal hydride (NiMH), lithium (Li), or lithium-ion batteries. Specific battery information is given in this user guide. Batteries must be recycled or disposed of properly. This symbol (crossed-out wheeled bin) indicates separate collection of waste electrical and electronic equipment in the EU countries. Please do not throw the equipment into the domestic refuse. Please use the return and collection systems available in your country for the disposal of this product. 31

15 Specifications RAE PowerPak User s Guide Display Customized LCD and red/orange/green LED Dimensions 36.2 cm x 26 cm x 14.6 cm (14.25 H x 10.25 W x 5.75 D) Weight 15 kg (33 lbs) with four internal batteries Package IP-65 Output 3.3V±0.1V Voltage Maximum 0.33A Output Current Capacity Two internal battery units: 26Ah Four internal battery units: 52Ah Mounting Stainless-steel wall-mount plate Options Stainless-steel or zinced steel version 32

Appendix A: Controlled Part Of RAE PowerPak (FTB1000) Manual The scope of this document is to control the safety-related parts of the manual, which cannot be changed without permission from the competent body. WARNINGS Warning: This instrument has not been tested in an explosive gas/air atmosphere having an oxygen concentration greater than 21%. Substitution of components may impair suitability for intrinsic safety. Replace encapsulated internal batteries only in nonhazardous locations. Warning: Charging of the FTB 1000 by means of mains charger can only be done in safe area and only with RAE Systems Charger P/N F03-3012-000. Warning: The internal encapsulated battery units can only be exchanged with the original RAE Systems battery. 33

RAE PowerPak Marking The RAE PowerPak is certified according to the IECEx scheme, ATEX and CSA for US and Canada as protected by intrinsic safety. The product is marked with the following information: RAE PowerPak Type FTB1000. Serial No/barcode: F032XXXXXX IECEx DNV 09.0003X Ex ia I/IIC T4 0575 IM1/II 1G Ex ia I/IIC T4 DNV 09 ATEX 55726X Li: 0.1 µh ; Ci: 0.1 µf ; Ui: 10 V Ii : 3.33 A; Pi: 8.8 W; Um: 11V; Lo: 3.4 µh; Co: 100 µf; Uo : 3.6 V Io: 3.2A; Po: 3.1 W; Lo/Ro: 20.6µH/Ω Cl.I Dv 1, Group A,B,C,D T4 Only as to intrinsic safety for use in hazardous loc. Intrinsically safe/ Securite Intrinseque/Exia -40º C < Tamb < +55º C Warning: Read User s Manual for Intrinsic Safety Precautions. 34

Operation Area and Conditions Hazardous Areas classified by Zones RAE PowerPak is intended to be used in mines susceptible to firedamp or hazardous areas classified for zone 0, zone 1 or zone 2, within the temperature range of -40º C to +55º C, where gases of explosion groups IIA, IIB or IIC and T4 may be present. Hazardous Areas classified by Divisions RAE PowerPak is intended to be used in hazardous areas classified for Class I Div. 1 or 2, within the temperature range of -40º C to +55º C, where gases of explosion groups A, B, C or D and temperature class T4 may be present. Instruction For Safe Use Strictly follow the instructions for safe use. Application of the RAE PowerPak requires full understanding and strict observation of the instructions. The RAE PowerPak can be charged in hazardous areas by a charger complying with the intrinsically safe input entity parameters. The RAEPowerPak can be charged outside hazardous areas by a charger complying with the Um parameter. The internal encapsulated battery units can only be exchanged with the original RAE Systems battery, Part Number: F03-3002-000, in a safe area or with a "hot zone" permit. The RAEPowerPak can be connected and disconnected inside the hazardous area. 35

Use In Hazardous Areas Equipment which is intended for use in explosive atmospheres and which has been assessed and certified according to international regulations may be used only under specified conditions. The components may not be modified in any way. The appropriate regulations for service and repair must be properly observed during such activities. 36

RAE Systems by Honeywell World Headquarters 3775 N. First St. San Jose, CA 95134-1708 USA Phone: 408.952.8200 Toll-Free: 888.723.4800 Fax: 408.952.8480 E-mail (sales support): raesales@raesystems.com E-mail (technical support): tech@raesystems.com Web Site: www.raesystems.com RAE Systems Europe Kristinehøj 23A, DK-2770 Kastrup Denmark Tel: +45.8652.5155 Fax: +45.8652.5177 RAE Systems (Hong Kong) Ltd. Units 1516-18, 15/F, Delta House, 3 On Yiu Street Shatin, N.T. Hong Kong Web: www.raesystems.cn Email: asiasales@raesystems.com Phone: +852.2669.0828 RAE Systems Middle East LOB 7, Ground Floor, Office 19, Jebel Ali Free Zone Dubai, United Arab Emirates Email: mesales@raesystems.com Phone: +971.4.887.5562 Rev. A July 2009 P/N F03-4001-000