PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Similar documents
A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

SECTION MOTOR CONTROL

WARREN COUNTY, N.Y. M/E REFERENCE

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

SECTION ENCLOSED CONTROLLERS

Ice Rink Renovation & New Clubhouse

SECTION PANELBOARDS

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Design Standard. Purpose: Design Standard:

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

SECTION MOTOR CONTROLLERS

SECTION MOTOR CONTROLLERS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Generator Fire Safety: Generator assemblies should be located outside the building.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

VARIABLE FREQUENCY DRIVES

SECTION VARIABLE FREQUENCY DRIVE UNITS

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

CONTENTS. B. System Design and Performance Requirements

University of Houston Master Construction Specifications Insert Project Name

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

SECTION ELECTRIC DISTRIBUTION

A. Submit manufacturer's literature and technical data before starting work.

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

MAGNETIC MOTOR STARTERS

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

IN2 Enclosed Switches and Circuit Breakers

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

A. This section includes unit capacitors for power factor correction.

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

SIGNAL WORDS QUALIFIED PERSON

SECTION DISTRIBUTION AND GROUNDING

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

10 Commercial, Industrial, Agricultural Services

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

University of Houston Master Construction Specifications Insert Project Name

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

Design Standards NEMA

For Options, Modifications and Accessories, see pages Discount Schedule A6

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

Power Break II Switchboard

Multi-Pak Group Control

Chapter 6 Generator-Voltage System

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

Service Entrance Methods

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Industrial Control Transformers

SECTION MOTORS & MOTOR CONTROLLERS

KD LV Motor Protection Relay

C1000 Series Automatic Cap Bank

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Self-protected Combination Starters System PKZ 2-SP

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 Lihue, Kauai, Hawaii Original Sheet 5 RULE NO. 2 CHARACTER OF SERVICE

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Introduction. Upon completion of Motor Control Centers, you should be able to: Explain the role of motor control centers in a distribution system

MEDIUM-VOLTAGE SWITCHGEAR

7. SERVICES OVER 600 VOLTS

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Medium Voltage Metal-Enclosed Switches

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

BUSWAY Low Voltage (Pow-R-Flex)

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

Application Description

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Quik-Spec Coordination Panelboard Specifications

MaxPak Plus Analog DC V S Drive

Transcription:

PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling of existing structure for Indiana University. Items pertinent to requirements of Indiana University are contained herein. The specification section numbers referenced by these standards are to help the A&E firms identify where IU Engineering standards are to be applied. These specification section numbers are based upon CSI standards and may not correspond to a particular A&E firm s standard specification section numbering scheme. Compliance with codes and OSHA regulations are minimum requirements. When requirements of Federal and/or State Codes are at variance with the contents of this publication, the most demanding requirements shall be observed. ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! MATERIAL CONTAINED HEREIN SHALL NOT BE COPIED VERBATIM IN SPECIFICATIONS OR IN NOTES ON THE DRAWINGS EXCEPT WHEN INSTRUCTIONS ARE GIVEN TO COPY CERTAIN ARTICLES OR PARAGRAPHS. ********************************************************** Changing technology and changes in State or University policies will require continuing revisions of these standards. Revisions will be maintained online at www.indiana.edu/~uao. Architects and Engineers doing work for the University are expected to ensure that they are working with the latest revision of the standards. Throughout these standards, cross-references have been made frequently to emphasize the importance of coordination of all parts of the contract documents for a project. Because of the requirement for complete coordination, the holder of this document is cautioned to furnish complete standards to consultants or to ascertain that consultants have copies of the referenced sections and paragraphs affecting the consultant s work. If questions arise concerning instructions contained herein, please request clarification from Indiana University, Department of Engineering Services, (812) 856-7055. Preface to IU Electrical Engineering Standards Page 1 of 1

Section 26 29 00 Low-Voltage Controllers Also Included: 26 24 19 - Motor-Control Centers 26 29 23 - Variable-Frequency Motor Controllers 26 35 33 - Power Factor Correction Equipment A. Motor Controller Applications 1. All campuses of Indiana University have a pre-purchase agreement with Johnson Controls and Siemens Automation. This agreement provides for the design and delivery of all HVAC controls including motor controllers. Motor controllers provided as part of this agreement must be specified to be installed by the Electrical Contractor. Coordinate with Engineering Services or CFS for all HVAC motor controllers. a. In general, motor controllers are not provided as part of the pre-purchase agreement on the IUPUI campus. Coordinate with CFS 2. For motor controllers that are not part of the pre-purchase agreement, the following shall apply. a. Utilize a Motor Control Center (MCC) whenever there are four (4) or more motors loads in close proximity to each other, e.g. in the same machine room. Do not install Variable Frequency Drives (VFD) in MCC s. b. Utilize individual motor controllers for less than four (4) motor loads, or if the motor loads are interspersed throughout a building. c. Preferred manufacturers for motor controllers are Allen-Bradley, Cutler- Hammer, General Electric, Siemens, and Square D. B. Individual Motor Controllers (3 Phase) 1. Individual 3 phase motor controllers shall be combination type with fusible disconnects. The controllers shall have the following features: a. Individual control transformer with fused primary and secondary, 120 volt secondary output, and 50VA spare capacity. b. Manual reset overloads. c. Hand-Off-Auto selector switch unless noted otherwise. d. Long life neon or LED pilot lights to indicate unit is in the run condition. Where multi-speed motors are served provide separate pilot lights for each speed. e. Phase reversal/phase loss relays. f. NEMA Size "0" minimum. g. NEMA rated contacts - IEC rated contacts are not acceptable. 26 29 00 Low-Voltage Controllers Page 1 of 5

h. Two (2) auxiliary contacts convertible from N.O. to N.C. i. NEMA rated enclosure for the environment present, usually NEMA 1 for interiors and NEMA 3R for exteriors. 2. Controllers for motors 20 horsepower and smaller at 208 volts, and 50 horsepower and smaller at 480 volts, shall be full voltage non-reversing. Stardelta, closed transition, or solid state soft-start reduced voltage type controllers shall be used for motors 25 HP and larger at 208 volt, and 60 HP and larger at 480 volt. C. Individual Motor Controllers (Single Phase) 1. Single phase manual starters for fractional horsepower motors shall consist of a quick-make, quick-break toggle switch with one piece melting alloy type thermal overloads. Where applicable, pilot lights shall be long life neon. 2. Where fractional horsepower motors are to be automatically started, use starters meeting the requirements of the paragraph above. D. Motor Control Centers (Section 26 24 19) 1. General a. Bus bar shall be copper and a separate ground bus shall be included throughout. b. Wiring shall be NEMA Class 1, Type B-T. c. Enclosure shall be NEMA 1 gasketed for interior and NEMA 3R gasketed for exterior installations. MCC s shall be floor mounted and set upon a 4 concrete housekeeping pad. d. Provisions for future addition of sections shall be included so that matching sections of the same current rating can be added without the use of transition sections. e. Adequate horizontal and vertical wireways shall be provided. In general 12" at top, 6" at bottom, and 6" vertical shall be specified. f. The main horizontal bus shall be enclosed in an isolated compartment to prevent accidental contact with other equipment or wiring. Compartment shall have removable barriers to permit access for maintenance purposes. g. Minimum starter size shall be NEMA 1. Starters shall meet the requirements of paragraph B above. All cubicles shall have minimum 3" extension for control relays. h. All cover doors (front and rear) shall be hinged type. Where adequate space for motor control centers is a problem consideration may be given to back-to-back construction. i. Minimum gauge steel used on doors shall be #14. j. Care should be used in locating the MCC. At minimum the location should meet NEC requirements of Table 110.26(A)(1) - Condition 2. The exclusively dedicated space requirements of NEC Article 110.26 shall be strictly enforced. Additional space for maintenance, future extensions, 26 29 00 Low-Voltage Controllers Page 2 of 5

and possible replacement should be factored into the location selected. The consultant shall work with the Engineering Services or CFS in locating this equipment. k. Where motor control centers are rated 600 amps or greater provide with a main disconnect. Disconnect may be a molded case circuit breaker. l. Each motor control center shall have a minimum of two (2) spare cubicles fully equipped for a future motor load and two (2) spaces for future starters. 2. Fault Withstand Capability a. The motor control center shall be suitable for operation at the maximum available fault current. The unit shall be labeled by the manufacturer to indicate the maximum fault current rating taking into account the structure, bussing, main feed, starter cubicles, and devices within the motor control center. Do not use bus bar bracing or rating of the main disconnect as the maximum available fault current rating for the motor control center. b. The consulting engineer shall specify the interrupting rating of the motor control center equipment. 3. Preferred MCC Manufacturers a. Allen Bradley b. Eaton, Cutler-Hammer c. GE d. Siemens e. Schneider Electric, Square D E. Variable Frequency Drive (Section 26 29 23) 1. Variable Frequency Drive (VFD) shall convert incoming three phase, 60 hertz power to an adjustable voltage and frequency for controlling motor speed. Speed range shall be from 10% to 110%. The variable frequency drive shall use full digital pulse width modulation using insulated gate bipolar transistors (IGBT) for speed control and shall include the following: a. Minimum efficiency at full load of 95 percent. b. Power Factor of 1.0 to 0.95 lagging over entire operating range. c. Total harmonic voltage distortion shall not exceed 5% as measured on the line side of the drive input. d. Power outage ride through capability of 2 seconds with no disruption of output. This is to allow for operating times of utility system circuit breakers. In order to achieve the 2 second ride through, it may be necessary to add a UPS. e. Adjustable auto restart with selection of number of restart attempts and time interval between restarts. f. Ability to start (or restart) into a rotating motor without component failure or faulting of the drive. Drive shall employ start on the fly method. g. Integral fused switch on line side of drive for circuit disconnecting means. h. Where directed by Engineering Services or CFS, include manual by-pass 26 29 00 Low-Voltage Controllers Page 3 of 5

feature with magnetic contactors. 2. Product Features a. Solid state circuit protection incorporating voltage rate-of-change and current rate-of-change protection for IGBTs. b. Instantaneous electric trip protection for the following occurrences: 1) 110% of drive maximum sine wave current rating is exceeded. 2) Output phase-to-phase short circuit condition and output phaseto-ground short circuit condition. 3) High and low input voltage and loss of phase input current. c. LCD display, 2 line, 40 character minimum. Display shall indicate operating parameters with English descriptors. d. Keypad adjustment controls for the following shall be provided: 1) Maximum (15 to 66 Hz) and minimum (3 to 60 Hz) frequency. 2) Acceleration and deceleration times (1 to 360 seconds). 3) Voltage/Hz ratio and voltage offset boost. 4) Current limit (50% to 110%). 5) Three critical frequency avoidance bands. 6) Switching frequency adjustment (2 to 8 khz, set to 3 khz). e. In general, the control signal for the drive will be 4-20mA or a 0-10vfdc signal from a Digital System Controller in the building's temperature control system. 3. Installation a. Location of variable frequency drive shall be selected to allow for adequate clearances for service, maintenance, and replacement. Distance from load served shall be as short as practical and under no circumstances to exceed manufacturer s recommendations. b. Where specified, drive isolation transformers shall be located adjacent to the VFD. Secondary conductors shall not exceed 10'-0" without overcurrent protection. c. Electrical noise shall not exceed IEEE Std. 519, with Point of Common Coupling defined as the line side of the isolation transformer and assuming the values for General Systems in chapter 10, Recommended Practices for Individual Consumers. d. Use insulated tap connectors like Polaris IT Series to make wiring connections inside the motor termination box. Do not use insulated twiston spring type connectors, i.e. wire nuts. e. During manufacturer start-up and/or training, provide copy of actual field programming to Owner s representative. 4. Preferred Manufacturers of Variable Frequency Drives 1. Allen-Bradley 2. Asea Brown Boveri 3. Danfoss Graham - IUB Only 4. Eaton - IUPUI Only 5. Toshiba - IUPUI Only 26 29 00 Low-Voltage Controllers Page 4 of 5

F. Power Factor Correction (Section 26 35 33) 1. Power factor correction capacitors shall be specified for motors 10 horsepower and larger which do not use a variable frequency drive. 2. Capacitors shall be connected to the motor controller on the load side of the contactor and ahead of the starter overloads. Locate capacitor adjacent to or above motor controller. 3. Capacitors shall utilize non-flammable, NFPA III B impregnant. Units shall have current limiting fuse in each phase and shall have blown fuse indicator pilot lights on front of enclosure. 4. Preferred Manufacturers for Power Factor Correction Equipment a. Aerovox b. General Electric c. Myron Zucker d. Commonwealth Sprague e. Square D Company f. Northeast Power Systems, Inc. (NEPSI) - medium voltage only g. Controllix - medium voltage only 5. Consultant shall evaluate harmonic loading of the system and provide documentation to Engineering Services or CFS for evaluation. Specify filtered capacitors where required. END OF 26 29 00 26 29 00 Low-Voltage Controllers Page 5 of 5