wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

Similar documents
Wiring Diagrams (Including Accessories) (50/60 Hz)

Wiring Diagrams DIAGRAM INDEX

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

Installation Instructions

Installation Instructions

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

Installation Instructions

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

Installation Instructions

Installation Instructions

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Installation Instructions

Installation Instructions

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Product Data. 38AUZ/D 50 Hz Commercial Split Systems Air Conditioning Condensing Units 18.3 kw to 59.2 kw FEATURES/BENEFITS

CAS. Product Specifications

CAS. Product Specifications

Package Unit Modulating Economizer Installation Instructions

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

Installation Instructions

Installation Instructions

ZHA/ZHB SERIES WARNING

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS

Installation Instructions

F SERIES. Floor Exposed Vertical Fan Coil Units. Nominal Sizes 200 thru 1200 CFM

Installation Instructions

Predator Model Number Nomenclature

Installation Instructions

WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C

POWER TRIM 5 E DUAL POWER TRIM CONTROL

Package Unit Modulating Economizer Installation Instructions

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

Parts Information. Commercial Microwave Oven

PHR5. Product Specifications

Installation, Start-Up and Configuration Instructions

WIRING DIAGRAM SYMBOLS

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

ARUF Series Multi-Position

INSTALLATION INSTRUCTION

Parts List, Tech Labels, Wiring Diagrams

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Installation Instructions

INSTALLATION INSTRUCTIONS ECOHLX Series Horizontal Economizer and PEHALX Series Economizer with Power Exhaust for York LX Series. Warning.

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Installation Instructions

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Installation Instructions

TRI-CAPACITY PACKAGE UNIT

Parts List Charging Charts & Wiring Diagrams

Installation Instructions

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase

Installation Instructions

Installation Instructions Read these instructions completely before attempting to install the Vertical EconoMi$er X Accessory.

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

Installation Instructions

RP6.52Y (ERRATA 1) (202) 2 of 12

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Comfort Pack Archived Part Lists PARTS LISTS

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

Installation Instructions

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

INSTALLATION INSTRUCTION

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

REPAIR PART INSTALLATION INSTRUCTIONS

Installation Instructions

B2HZ SERIES - 13 SEER SINGLE PACKAGED HEAT PUMPS (R-410A, STYLE A,B)

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

ELECTRICAL / GENERAL INFORMATION

RHS. Product Specifications. PACKAGE HEAT PUMP UNIT R 410A SINGLE PACKAGE ROOFTOP TONS (1 & 3 Phase)

Installation Instructions

INSTALLATION INSTRUCTIONS MODELS (-)XRD-PDCM3 & (-)XRD-SDCM3 VERTICAL AIRFLOW ECONOMIZERS

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

LB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS

XENON POWER SUPPLY 4000 Watt Gladiator IV

HIGH EFFICIENCY PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

MARINE / INDUSTRIAL SINGLE PACKAGE COOLING UNIT. Marine Systems 90MA/MU SERIES 3. CARRIER CORPORATION RevC

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

This parts list is current as of the above revision date. See for the current revision.

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

Transcription:

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F 036-150 3 to 12 1 / 2 Tons Cancels: New WD 580F.36.1 10/15/00 *Low NOx/California compliant units. DIAGRAM INDEX UNIT LABEL DIAGRAM Unit 580F Voltage-Phase-Hertz Type Label Diagram Figure No. 208/230-1-60 Schematic/Component Arrangement 50DK508460 1 208/230-3-60 Schematic/Component Arrangement 50DK508515 2 036,048 460-3-60 Schematic/Component Arrangement 50DK508518 3 575-3-60 Schematic/Component Arrangement 50DK508521 4 208/230-3-60* Schematic/Component Arrangement 50DK509082 5 460-3-60* Schematic/Component Arrangement 50DK509084 6 208/230-1-60 Schematic/Component Arrangement 50DK508514 7 208/230-3-60 Schematic/Component Arrangement 50DK508516 8 060 460-3-60 Schematic/Component Arrangement 50DK508519 9 575-3-60 Schematic/Component Arrangement 50DK508522 10 208/230-3-60* Schematic/Component Arrangement 50DK509083 11 460-3-60* Schematic/Component Arrangement 50DK509085 12 208/230-3-60 Schematic/Component Arrangement 50DK508517 13 072 460-3-60 Schematic/Component Arrangement 50DK508520 14 575-3-60 Schematic/Component Arrangement 50DK508523 15 208/230-3-60 Schematic/Component Arrangement 50DK508790 16 090-150 460-3-60 Schematic/Component Arrangement 50DK508791 17 575-3-60 Schematic/Component Arrangement 50DK508792 18 ACCESSORY WIRING Description Unit Size Fig. No. Motormaster I Control 036-150 19 Motormaster II Control 036-072 20 090-150 21 Time Guard II Device 036-150 22 Solid-State Enthalpy Control 036-150 23 Differential Enthalpy Control 036-150 24 EconoMi$er 036-150 25 EconoMi$er Sensor Wiring 036-150 26 Power Exhaust 036-150 27

LEGEND AHA Adjustable Heat Anticipator C Contactor, Compressor CAP. Capacitor CB Circuit Breaker CC Cooling Compensator COMP Compressor Motor D Diode EC Enthalpy Control ECON Economizer EPS Emergency Power Supply (Nine-Volt Battery) EQUIP Equipment ER Economizer Relay FPT Freeze-Up Protection Thermostat GND Ground HPS High-Pressure Switch HS Hall Effect Sensor I Ignitor IDM Induced-Draft Motor IFC Indoor-Fan Contactor IFM Indoor-Fan Motor IFMOVL Indoor-Fan Motor Overload IGC Integrated Gas Unit Controller LED Light-Emitting Diode LPS Low-Pressure Switch LS Limit Switch MGV Main Gas Valve MTR Motor OAT Outdoor-Air Thermostat OFC Outdoor-Fan Contactor OFM Outdoor-Fan Motor OLR Overload Relay P Plug PL Plug Assembly QT Quadruple Terminal R Relay RS Rollout Switch SAT Supply-Air Thermostat SEN Sensor ST Start Thermistor SW1 Switch Fully Open SW2 Switch Fully Closed SW3 Switch Minimum Vent Position SW4 Switch Maximum Vent Position TC Thermostat, Cooling TDR Time-Delay Relay TH Thermostat, Heating TRAN Transformer Field Splice Marked Wire Terminal (Marked) Terminal (Unmarked) Terminal Block Splice Splice (Marked) Factory Wiring Field Control Wiring Field Power Wiring Accessory or Optional Wiring To indicate common potential only. Not to represent wiring. Ground ( Capacitor 1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent. 2. Thermostat: HH07AT170, 172, 174, and P272-2783 Subbase: HH93AZ176, 178, and P272-1882, 1883 NOTES FOR FIG. 1, 7 3. Set heat anticipator at.14 amp for units with 2 stages of heating. Set stage two anticipator at.14 amps. 4. Use copper conductors only. 5. TRAN is wired for 230-v unit. If unit is to be run with 208-v power supply, disconnect BLK wire from 230-v tap and connect to 208-v tap. 1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent. 2. Three-phase motors are protected under primary single-phasing conditions. 3. Thermostat: HH07AT170, 172, 174, and P272-2783 Subbase: HH93AZ176, 178, and P272-1882, 1883 NOTES FOR FIG. 2, 5, 8, 11, 13, 16 4. Set heat anticipator at.14 amp for units with 2 stages of heating. Set stage two anticipator at.14 amps. 5. Use copper conductors only. 6. TRAN is wired for 230-v unit. If unit is to be run with 208-v power supply, disconnect BLK wire from 230-v tap (ORN) and connect to 208-v (RED). Insulate end of 230-v tap. 1. If any of the original wire furnished must be replaced, it must be replaced with Type 90 C wire or its equivalent. 2. Three-phase motors are protected under primary single-phasing conditions. 3. Thermostat: HH07AT170, 172, 174, and P272-2783 Subbase: HH93AZ176, 178, and P272-1882, 1883 NOTES FOR FIG. 3, 4, 6, 9, 10, 12, 14, 15, 17, 18 4. Set heat anticipator at.14 amp for units with 2 stages of heating. Set stage two anticipator at.14 amps. 5. Use copper conductors only. 2

Fig. 1 Schematic/Component Arrangement; 580F036,048, 208/230-1-60 3

Fig. 2 Schematic/Component Arrangement; 580F036,048, 208/230-3-60 4

Fig. 3 Schematic/Component Arrangement; 580F036,048, 460-3-60 5

Fig. 4 Schematic/Component Arrangement; 580F036,048, 575-3-60 6

Fig. 5 Schematic/Component Arrangement; Low NOx 580F036060N, 036090N; 580F048060N, 048090N, 048120N; California Compliant 580F036114, 580F048149; 208/230-3-60 7

Fig. 6 Schematic/Component Arrangement; Low NOx 580F036060N, 036090N; 580F048060N, 048090N, 048120N; California Compliant 580F036114, 580F048149; 460-3-60 8

Fig. 7 Schematic/Component Arrangement; 580F060, 208/230-1-60 9

Fig. 8 Schematic/Component Arrangement; 580F060, 208/230-3-60 10

Fig. 9 Schematic/Component Arrangement; 580F060, 460-3-60 11

Fig. 10 Schematic/Component Arrangement; 580F060, 575-3-60 12

Fig. 11 Schematic/Component Arrangement; Low NOx 580F060060N, 060090N, 060120N; California Compliant 580F060149; 208/230-3-60 13

Fig. 12 Schematic/Component Arrangement; Low NOx 580F060060N, 060090N, 060120N; California Compliant 580F060149; 460-3-60 14

Fig. 13 Schematic/Component Arrangement; 580F072, 208/230-3-60 15

Fig. 14 Schematic/Component Arrangement; 580F072, 460-3-60 16

Fig. 15 Schematic/Component Arrangement; 581B072, 575-3-60 17

18 Fig. 16 Schematic/Component Arrangement; 580F090-150, 208/230-3-60

19 Fig. 17 Schematic/Component Arrangement; 580F090-150, 460-3-60

20 Fig. 18 Schematic/Component Arrangement; 580F090-150, 575-3-60

580F036-072 LEGEND C Contactor 580F090-150 Fig. 19 Motormaster I Wiring Details LEGEND C Contactor OFC Outdoor-Fan Contactor TRAN Transformer *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20 F higher than the standard operating mode. In this alternate mode, the outdoor fan begins cycling at higher outdoor ambient temperatures. This mode should only be used if the evaporator coil shows signs of frosting at low outdoor ambient temperatures. To select the alternate operating mode, move the jumper wire on the Motormaster II control board from reset T1 to reset T2. NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 20 Motormaster II Wiring Schematic, 580F036-072 21

LEGEND C Contactor OFC Outdoor-Fan Contactor TRAN Transformer *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the average condensing temperature approximately 20 F higher than the standard operating mode. In this alternate mode, the outdoor fan begins cycling at higher outdoor ambient temperatures. This mode should only be used if the evaporator coil shows signs of frosting at low outdoor ambient temperatures. To select the alternate operating mode, move the jumper wire on the Motormaster II control board from reset T1 to reset T2. NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application. Be sure to insulate unused tap. Refer to color code. Fig. 21 Motormaster II Wiring Schematic, 580F090-150 TIME GUARD I I DEVICE BRN BRN T1 T3 T2 2 1 3 ECONOMIZER OR Y1 OR Y2* CLO COMPRESSOR SAFETIES HIGH EFFICIENCY 3 TO 12 1 / 2 TON ROOFTOP UNITS C OR CR TIME GUARD I I DEVICE BRN BRN T1 T3 T2 2 1 3 C CLO CR LEGEND *Per compressor circuit. ECONOMIZER OR Y1 OR Y2* Contactor Compressor Lockout Control Relay CLO COMPRESSOR SAFETIES STANDARD EFFICIENCY 3 TO 12 1 / 2 TON ROOFTOP UNITS Fig. 22 Time Guard II Device, 580F036-150 C OR CR 22

A B C D LED TR TR1 SO + SR + 2 3 1 24 VAC SUPPLY FROM ECONOMIZER CONTROL } SECTION (RED TO TR, BRN TO TR1) } TO SENSOR MOUNTED ON BACK OF CONTROL 620 ohm JUMPER GRAY WIRE FROM ECONOMIZER HARNESS RED WIRE FROM ECONOMIZER SWITCH 3 (NORMALLY CLOSED) A B C D LED TR SO SR 2 TR1 + + 3 1 24 VAC SUPPLY FROM ECONOMIZER CONTROL SECTION (RED TO TR, BRN TO TR1) TO SENSOR MOUNTED ON BACK OF CONTROL S (HH57AC078 + SENSOR) GRAY WIRE FROM ECONOMIZER HARNESS RED WIRE FROM ECONOMIZER SWITCH 3 (NORMALLY CLOSED) NOTE: Switches shown in high enthalpy state. Terminals 2 and 3 close on enthalpy decrease. Fig. 23 Wiring Connections for Solid-State Enthalpy Control (HH57AC077) NOTES: 1. Remove factory-installed jumper across SR and + before connecting wires from HH57AC078 sensor. 2. Switches shown in high outdoor-air enthalpy state. Terminals 2 and 3 close on low outdoor air enthalpy relative to indoor air enthalpy. Fig. 24 Wiring Connections for Differential Enthalpy Control (HH57AC077 and HH57AC078) LEGEND OAT Outdoor-Air Thermostat Fig. 25 EconoMi$er Wiring 23

ECONOMI$ER CONTROLLER OAT COM OAH -15 V RAT COM RAH +15 V CO 2 (+) CO 2 COM DAT COM REM POT COM LED COM BROWN VIOLET WHITE RED BROWN VIOLET WHITE RED TEMP TEMP COM OUT PWR TEMP TEMP COM OUT PWR CO 2 SENSOR V+ 24 COM VAC SUPPLY AIR TEMPERATURE SENSOR PINK TEMP VIOLET TEMP OUTDOOR AIR SENSOR RETURN AIR SENSOR Fig. 26 EconoMi$er Sensor Wiring, 580F036-150 TO FUSED DISCONNECT RED GRAY RED YEL BLU GRAY HT01AH859 (575 VAC) H1 X4 X2 X3 H2 X1 HT01AH850 (460 VAC) H1 X4 H3 X2 H2 X3 H4 X1 SECONDARY 230VAC SECONDARY 230VAC FIELD SUPPLIED WIRING BLACK OR COMPRESSOR 1 CONTACTOR 11 21 230VAC BLACK LT. BLUE 3 6 9 B 2 x 4 IN. HANDY BOX BLACK L1 BLUE L2 GREEN GND 13 1 1 2 2 3 3 4 4 230 VAC 1 PHASE 23 4-PIN CONNECTOR PLUG L1 L2 GND BLACK BLUE GREEN BROWN FAN 1 C1 GREEN/ YELLOW BLACK BLUE BLACK LT. BLUE 2 1 3 5 8 4 7 A 6 9 B R1 24 VAC 3-PIN CONNECTOR PLUG ORANGE YELLOW BROWN 1 2 3 BROWN FAN 2 C1 GREEN/ YELLOW BLACK 2 1 5 8 4 7 A R2 24 VAC BLUE Fig. 27 Wiring Diagram for Power Exhaust System Copyright 2000 Bryant Heating & Cooling Systems CATALOG NO. 5358-010