POWERPLEX PANELBOARD 1

Similar documents
P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE

PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE

EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS

P-2 ccsaus, curus Class I Div. 2 Group B,C, D Class I Zone 1 AEx de IIB+H 2 T6 Ex d IIB+H 2 T6 U Type 4X, IP66

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

VERSATILE, DIRECT-MOUNT POWER FOR EXTREME ENVIRONMENTS IP67 SCP-X POWER SUPPLIES CLASS 2 LISTED

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

Certified to Protect. Built to Endure.

Explosionproof Protection Simplified

DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.

din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide

GREATER VERSATILITY WITH LESS DOWNTIME

Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE

Panelboard Protection on a Global Scale

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Power distribution SynergEX panelboards. SynergEX. Class I, Division 2 panelboards

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Dry-Type Transformers Mini-Power Centers

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

CIRCUIT BREAKER PANELBOARDS

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

X1PB: Explosionproof Panelboards

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

Division 1 Explosionproof Panelboards

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

Lighting and Power Distribution Panelboards

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

Solar Combiner Solutions

SynergEX Panelboards for Hazardous Locations

ATX DPD Series Distribution Panelboards Flameproof

D2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

EDS / EFS Series Control Stations

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

SECTION PANELBOARDS

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

EDS / EFS Series Control Stations

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Power-Limiting Cables

JAMESBURY VALVCON QX-SERIES ELECTRIC ACTUATOR

EDS / EFS Series Control Stations

Selection Guide. Control Circuit and Load Protection

Safety Alert: Square D Safety Switches

Service Entrance Methods

EBMC Combination Line Starters and Enclosures

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

GTD-Series. Direct Gas Actuators

JAMESBURY VALVCON ESR-SERIES ELECTRONIC SPRING RETURN ELECTRIC ACTUATOR

Cummins delivers reliable power in one easy-to-use system

Pressure control solutions for your industry. Aerospace & Defense

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Eylander Electric Inc

Fisher D4 Control Valve Assembly

Hazardous Factory Sealed Control Devices

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

Solar Combiner Solutions

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Microlectric. CO Series. Meter sockets. A complete family of combination meter sockets and breaker units

Product Guide. enclosed NEMA STARTERS

Product guide. Enclosed NEMA starters. Answers for industry.

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

Three-Phase Pole Mounted Recloser

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Selection Guide Motor Control Device Solutions

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

GTD-Series. Direct Gas Actuators

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Micro Motion 7827 Digital Viscosity Meter

3 Uninterruptible Power Systems

Pow-R-Flex low ampere busway

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

PDU Input Power Cord. Before installation. Specifications

Application guide. Tmax Link OEM UL 891 Switchboard Program

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Integrated Power Center 2 (IPC2) Space saving designs that save time and reduce costs

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Multiport Flow Selector. Compact And Economical Production Test Manifold

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Design Standard. Purpose: Design Standard:

XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Engine Generator Circuit Breakers

Application Description

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Transcription:

1 POWERPLEX PANELBOARD

2

ADVANCING PANELBOARD TECHNOLOGY WITH COMPONENT LEVEL PROTECTION. Introducing the PowerPlex Panelboard. Appleton's PowerPlex Panelboard changes the face of hazardous location panelboards by transferring the flamepath from the panelboard enclosure to individual circuit breaker housings. This highly engineered design delivers component level protection that increases hazardous location safety and flexibility, while greatly reducing and simplifying maintenance. It s a major advancement in panelboards from the worldwide leader in hazardous location electrical products. 3

INSTALLATION Appleton's PowerPlex Panelboard was engineered to provide a high level of flexibility during design and installation with no external conduit seals required. Mounting space is often at a premium within facilities, and installation locations can change during the design phase. With multiple sizes and breaker configurations, the modular PowerPlex Panelboard can be coupled both vertically and horizontally, providing a more flexible footprint. superior enclosure design The PowerPlex Panelboard s lighter weight helps make installations safer, more efficient and less costly. Its flat enclosure surfaces allow for simpler storage and transportation by eliminating the flanges required by the traditional enclosure s flamepaths. Optional gland plates enable easier on site installations and reconfigurations.

MAINTENANCE Quick and safe replacement of circuit breakers within hazardous locations can be done in the field with fewer people and at lower cost. Circuit breakers are accessed by simply unbolting the six fasteners securing the individual housing cover. Standard hand tools are all that s required and, unlike traditional panelboard enclosure covers, the individual circuit breaker housing cover can be easily removed with one hand. multiple breaker combinations Breakers are contained within a single housing. Each breaker housing accommodates: three 1-pole, or one 1-pole and one 2-pole, or one 3-pole circuit breaker for greater application flexibility. F-Frame breakers are shown. QC-Frame breakers are also compatible. Field replaceable breakers Circuit breakers are readily field replaceable. There are no special breakers to order and no heavy, bolted enclosure to secure. Utilizing standard, off the shelf circuit breakers reduces inventory costs as well as logistics for maintenance personnel. This creates the potential to significantly reduce installation time and costs. optimized breaker performance The PowerPlex Panelboard s circuit breaker housings are engineered to optimize circuit breaker life and performance. The unique design of the PowerPlex circuit breaker housing allows heat to safely dissipate, enabling the circuit breakers to maintain their rated amperage and reduce the possibility of nuisance tripping.

PROTECTION The PowerPlex Panelboard moves Appleton s proven labyrinth flamepath technology to the component level. Each circuit breaker is now placed within an individual housing designed with labyrinth joints. Just like in traditional cast panelboard enclosures, any ignited vapors or gases from inside the circuit breaker housing are cooled through the flamepaths before they are harmlessly vented into the surrounding atmosphere. Component level Flamepaths Standard Cutler-Hammer circuit breakers are secured inside individual housings. The top cover of the housing and the lower housing s labyrinth channel form the flamepath. enduring hazardous location integrity The compact, lightweight circuit breaker housings maintain flame proof integrity by eliminating the flamepath damage that is sometimes caused from mishandling or improperly securing traditional panelboards heavy, bolted enclosure covers. rugged Terminations Long term safety has also been designed into the interior of the PowerPlex Panelboard. Each circuit breaker housing connects to the panelboard through increased safety terminal connections. The terminations provide quick wiring access and are molded into the housing for unyielding performance through years of heavy vibrations and shocks. 6

customizable for more locations The PowerPlex Panelboard provides outer enclosure material options, such as stainless steel or fiberglass, for greater installation and application flexibility. Footprints are similar to traditional panelboards with configurations ranging up to 225 Amps at 600 VAC with or without a main circuit breaker. Conduit and cables no longer require sealing. Entries can be made on site, in any location, without jeopardizing flamepath protection, providing significant cost and time savings.

The PowerPlex Panelboard is flexible enough to protect powered operations throughout your facility. Whether it s heat trace applications that stretch across frozen fields or pump motors working 500 miles offshore. Each individual enclosure can fit 1-pole, 2-pole and 3-pole Cutler-Hammer F-Frame or QC-Frame circuit breakers for a voltage range from 120/240 to 600 VAC. Certifications ccsaus, curus Class I, Div. 2, Groups B, C, D Class I, Zone 1, AEx de IIB+H2 T6 Ex de IIB+H2 T6 U Type 4X, IP66 Rated -25 C to +40 C Standard Materials Enclosure: 316L stainless steel Alternate enclosure: GRP black Hardware: stainless steel Features 3-circuit to 42-circuit panelboard configurations Stainless steel or fiberglass enclosures Main breakers available from 100 to 225 Amps Branch circuit breakers available in 1-, 2- and 3-pole combinations with 10 to 225 Amp range Voltage ranges from 120/240 to 600 VAC Factory wired Field replaceable, standard North American Cutler- Hammer F-Series or QC-Series circuit breakers Self-aligning external actuation (optional) Standard bolt-on gland plate (bottom) Rated to -40 C with optional heater configurations Standard Standard Option Standard Option Standard Option Drain and breather Internal actuation Breaker actuators on door Direct wiring no terminal blocks Terminal blocks Solid color Window in door Standard Option Standard Option Main breaker in separate A or B size enclosure Main breaker in same panel (Not available in A size panels with branch circuits) Breakers up to 60 Amps Higher amperages - Consult factory Options 8 Circuit breaker operators on door - L Main breaker inside panel - PM Terminal blocks instead of direct wiring - TB Additional drain/vent - DV Additional gland plate (Specify GPT = Top, GPL = Left, GPR = Right, GPN = No gland plate) LED indicator lights - IL Thermostatically controlled heater - HTR Grounded neutral - GN Phenolic nameplate (specify legend) - NP Window - W Stainless steel legend plate (specify legend) - SP Circuit identification labels - CL Door padlock provision - P

SAMPLE PANELBOARD CATalog numbering RQ S A 1 2 3 BRANCH CIRCUITS MAIN TYPE ( See Footnote) 1 = 100 Amp lug 2 = 225 Amp lug 3 = 100 Amp main breaker*** 4 = 150 Amp main breaker*** 5 = 200 Amp main breaker*** 6 = 225 Amp main breaker*** 7 = Reserved for future use 8 = Reserved for future use 9 = Special size (Consult factory) SYSTEM VOLTAGE 1 = 120/240 2 = 240 3 = 120/208 4 = 277/480 5 = 480 6 = 347/600 7 = 600 8 = Special (Consult factory) 1 or 2 PANEL 1 = Single Panel 2 = Double Panel PANEL SIZE (In mm) Panel* Stainless Steel (mm) Inches A 370 x 370 x 200 14.5 x 14.5 x 7.9 B 560 x 370 x 200 22 x 14.5 x 7.9 C 560 x 560 x 200 22 x 22 x 7.9 D 750 x 560 x 200 29.5 x 22 x 7.9 E 1130 x 750 x 300 44.5 x 29.5 x 11.8 PANEL MATERIAL SERIES & BREAKER TYPE S = 316L P = Polyester** RQ = PowerPlex panel with QC-Frame breakers RF = PowerPlex panel with F-Frame breakers Branch Circuit Example: 3151P3202P6303P = (3) 15A 1-pole, (3) 20A 2-pole, (6) 30A 3-pole *Refer to specification tables or line drawings for maximum number of circuits **Consult factory for availability ***EHD is default for main circuit breaker 9

panelboard specifications F-Frame Panelboard Specifications F-FRAME QC-Frame Panelboard Specifications QC-FRAME Direct Wiring No Terminal Block Direct Wiring No Terminal Block Panel Panel Size (H X W X D) Main Breaker # of Branch Circuit Breakers Panel Panel Size (H X W X D) Main Breaker # of Branch Circuit Breakers A 370 x 370 x 200 (14.5 x 14.5 x 7.9) None 3 circuits @ 60 Amps A 370 x 370 x 200 (14.5 x 14.5 x 7.9) 3 circuits @ 40 Amps B 560 x 370 x 200 (22 x 14.5 x 7.9) None 3 pole @ 225 Amps 3 circuits @ 225 Amps None C D 560 x 560 x 200 (22 x 22 x 7.9) 750 x 560 x 200 (29.5 x 22 x 7.9) 12 circuits @ 40 Amps 24 circuits @ 40 Amps D 750 x 560 x 200 (29.5 x 22 x 7.9) 12 circuits @ 30 Amps E 1130 x 750 x 300 (44.5 x 29.5 x 11.8) 42 circuits @ 40 Amps E 1130 x 750 x 300 (44.5 x 29.5 x 11.8) 24 circuits @ 60 Amps 30 circuits @ 50 Amps circuit breaker specifications F-Frame Circuit Breaker Specifications F-Frame Circuit Breaker Interrupting Capacity (Symmetrical Amperes) Breaker Type Number of Poles Volts Volts DC 240 277 480 600 125 250 EHD 1 14,000 10,000 EHD 2, 3 18,000 14,000 10,000 FDB 2, 3 18,000 14,000 14,000 10,000 QC-Frame Circuit Breaker Specifications QC-Frame Circuit Breaker Interrupting Capacity (Symmetrical Amperes) Breaker Type Number of Poles Volts 120 240 QC 1 (max 40A) 10,000 10,000 QC 2, 3 (max 40A) 10,000 10,000 10

QC-FRAME 4.89" 124mm 14.57" 370mm 4.89" 124mm 1.96" 50mm 7.87" 200mm 3.00" 76mm A-PANEL 3 circuits @ 40 amps max 13.19" 335mm 14.57" 370mm 4.76" 121mm 16.02" 407mm " " " " " C-PANEL 12 circuits @ 40 amps max " " " " " 11 POWERPLEX PANELBOARD

QC-FRAME 22.05" 560mm 2.94" 75mm 2.50" 64mm 2.50" 64mm 2.94" 75mm 7.87" 200mm 1.22" 31mm 28.15" 715mm 29.53" 750mm D-PANEL 24 circuits @ 40 amps max 8.86" 225mm 23.50" 597mm 1.97" 50mm 6.18" 157mm 29.53" 750mm 3.50" 89mm 6.18" 157mm 11.81" 300mm 43.11" 1103mm 44.49" 1130mm E-PANEL 42 circuits @ 40 amps max 9.14" 232mm 30.98" 787mm 12 APPLETON

QC-FRAME D-PANEL coupled with B-Panel QC-Frame main breaker* 7.87" 200.00mm 22.05" 560.00mm 13.19" 335.00mm BOX 'B' 14.57" 370.00mm 2.22" 56.36mm 45.59" 1157.96mm 13.84" 351.50mm BOX 'D' 29.53" 750.00mm 14.31" 363.50mm 8.13" 206.40mm 23.50" 597.00mm 24.65" 626.00mm * Drawing illustrates two panelboards mounted together. Any size PowerPlex Panelboard can be coupled for a virtually unlimited number of configurations. 13 POWERPLEX PANELBOARD

F-FRAME 3.94" 124mm 14.57" 370mm 3.94" 124mm 7.87" 200mm.91" 23mm 3.06" 76mm 13.19" 335mm 14.57" 370mm A-PANEL 3 circuits @ 60 amps max 3.05" 121mm 16.02" 407mm 3.94" 100mm 14.57" 370mm 3.94" 100mm 7.87" 200mm.91" 23mm 6.79" 173mm 20.67" 525mm 22.05" 560mm B-PANEL 3 circuits @ 225 amps max 6.79" 173mm 16.02" 407mm 20.67" 525mm 7.87" 200mm.91" 23mm 3.94" 100mm 16.02" 407mm 14.57" 370mm 14.57" 370mm B-PANEL 3 pole @ 225 amps max (used as main circuit breaker) 3.94" 100mm 6.79" 173mm 22.05" 560mm 6.79" 173mm 14 APPLETON

F-FRAME 1.80" 46mm 1.53" 39mm 22.05" 560mm 1.80" 46mm 7.87" 200mm.91" 23mm 3.00" 76mm D-PANEL 12 circuits @ 30 amps max 28.15" 715mm 29.53" 750mm 23.50" 597mm 15 POWERPLEX PANELBOARD

F-FRAME 4.30" 109mm 29.53" 750mm 4.00" 102mm 4.30" 109mm 1.72" 44mm 11.81" 300mm 2.66" 68mm 43.11" 1095mm 44.49" 1130mm E-PANEL 24 circuits @ 60 amps max or 30 circuits @ 50 amps max 30.98" 787mm 16 APPLETON

F-FRAME C-PANEL coupled with B-Panel f-frame main breaker* 7.87" 200.00mm 22.05" 560.00mm BOX 'B' 13.19" 335.01mm 14.57" 370.00mm 2.22" 56.36mm 38.11" 967.96mm BOX 'C' 20.67" 525.00mm 22.05" 560.00mm 8.13 206.40mm 23.50" 597.00mm 24.65" 626.00mm * Drawing illustrates two panelboards mounted together. Any size PowerPlex Panelboard can be coupled for a virtually unlimited number of configurations. 17 POWERPLEX PANELBOARD

Appleton is our premium line of industrial location products under the EGS Electrical Group family of brands. EGS Electrical Group, a division of Emerson Industrial Automation, is a worldwide manufacturer of electrical products for virtually every type of environment. For over 150 years, our brands have been providing a rich tradition of long-term, practical, high quality solutions. Distributors, contractors, engineers, electricians and site maintenance professionals around the world trust EGS brands to make electrical installations safer, more productive and more reliable. EGS is organized into three focused businesses that provide distributors and end-users expert knowledge and excellent service. Electrical Construction Materials This group manufactures a broad range of electrical products including conduit and cable fittings, plugs and receptacles, enclosures and controls, conduit bodies and industrial lighting. Whether the application is hazardous location, industrial, or commercial, the ECM group has the products to meet your needs. Power Quality Solutions This group offers the broadest power quality line, including UPS, power conditioners, voltage regulators, shielded transformers, surge suppression devices and power supplies. Heating Cable Systems This group offers a broad range of electri cal heating cable products for residential, commercial, and industrial applications. Electrical Construction Materials Power Quality Solutions Heating Cable Systems EGS Electrical Group Canada Asia/Pacific Middle East 9377 W. Higgins Road 888.765.2226 65.6745.0114 971.4.8838.831 Rosemont, IL 60018 1.800.621.1506 Latin America China Europe www.appletonelec.com 52.55.5366-6180 x125 86.21.54260668 x305 33.1.4817.8502 The 18 Appleton, O-Z/Gedney, SolaHD, EasyHeat, Nelson and Emerson logos are registered in the U.S. Patent and Trademark Office. Cutler-Hammer is a trademark of the Eaton Corporation. All other product or service names are the property of their registered owners. 2009, EGS Electrical Group, LLC. All rights reserved.