LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Similar documents
UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

LUMELEX 2087 SERIES 120/277V LED XTM 19MM MOUNTING OPTIONS. Lighting Services Inc

GEMINI HOUSING SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS

MOUNTING SYSTEMS SPECIFICATIONS

When using electrical equipment, basic safety precautions should always be followed including the following:

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Install Guide PMX SERIES PENDANT MOUNTED MATRIX SP1 STYLE

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

RECESSED TRACK (120V) SPECIFICATIONS

SPEQ-L. Large Cylinder Track Head

SPEQ-L. Large Cylinder Track Head

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

PRIME PRIME 4 LED ARCHITECTURAL ROUND FLANGED DOWNLIGHT

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

SCPL High Output LED Pendant

6" Round Downlight. Product Overview Recessed Round Downlight Wattage: 38. Fixture Type. Performance Chart. Electrical Data. 6" Round Downlight

Model: LUM-P1-40WCDS LUM-P7-50WCDS

A CHANNEL. Installation Instructions for Tie Stix Wall 2-Light. Section One: 4SQ Version

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

MULTI-SPOT 1000/2000/3000 LUMEN LED

Finiré Prime. LED Recessed Downlights 13 / 14 W LED Round Adjustable Downlights 13 / 14 W LED Square Adjustable Downlights LUMINAIRE IMAGES

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER

LED DOWNLIGHTS. Pro and Prime LED Downlights ADVANTAGES OF VS LED DOWNLIGHTS

Busway Construction. Bus Bars

Ardito LED - A2RSF SPECIFICATION SHEET. 2-1/2" Series. Ultra-Thin Profile Round Regressed Shower Trim SPECIFICATIONS

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

ECO-T LED RECESSED TROFFER USER MANUAL

PRODUCT MANUAL Gecko Wireless One Zone LED Dimmer and Receiver

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

PIL0478 ISSUE 01/ 07/16

Project. Type. Notes. C custom UNV universal BI bi-level dimming +NL(#) night light circuit (7) O other (6) +GTD(#) generator transfer device (7)

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Installation Instructions: Eco SpunBay LED High Bays

ENLIGHTENING. LED High Bay. High Ceiling W. 73rd Street Bedford Park, IL Benefits. Markets & Applications

D3 INSTALLATION GUIDE

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Standards: UL & CUL Listed.

SURFACE CONTROLTrack SPECIFICATIONS

ENLIGHTENING. LED High Bay. High Ceiling W. 73rd Street Bedford Park, IL Benefits. Markets & Applications

FINA SUSPENDED INSTALLATION INSTRUCTIONS

Written By: David Hodson

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

LSI 20 Series 30A, 120V Surface Busway Components 1

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

WALL MOUNT - DIRECT/INDIRECT

INSTALLATION INSTRUCTION W Track Suspension system

BL7000 SYSTEM OPERATING MANUAL

SURFACE MOUNT. Project. Type. Notes

NRM2-511 / NRM2-512 / NRM2-518

I. Pendant Mount Installation

PRODUCT MANUAL Onyx 2 Zone In-Wall Wireless LED Dimmer and Receiver

Fluorescent Ring Light with Dimmer INSTRUCTIONS

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent square downlight 800 Lumens

Installation Instructions

AXLE LED PENDANT ASYMMETRIC W W W. L U M E N W E R X. C O M

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

LITON FLOOD / SPOT O U T D O O R A D J U S T A B L E L I G H T I N G

Installation Instructions MX LED Enhanced Color Adjustable

621 Recessed LED Downlight - 6

HIGH FLOW COLD AIR INTAKE SYSTEM INSTALLATION INSTRUCTIONS D , D A

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

SISU DP-330 DRIVE GEAR. Maintenance Manual

Customer service: or Upper mounting ring. Canopy

LLCRC LED. RC LED Linear Lighting Channel EXAMPLE: LLCRC48LED42SA WATT CAT# APPLICATIONS FEATURES & SPECIFICATIONS

A B C D E F. Tools Required (supplied by others)

SSX-300ST SolarMaxx 300 Illuminator

Model Location Dimming Location Output CRI * C.C.T. Reflector Shell Color Suspension Options Q4LP

WAVELIGHT -2 USER INSTRUCTIONS. Description:

Luminaires - LED High Bay

PROJECT INFORMATION PROJECT

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

LED GEL MOUNTED FRAME

PRODUCT SPECIFICATIONS

#TL T EA888 GEN 3 FUELING SYSTEM/ INSTALLATION INSTRUCTIONS

SPEQ-M. Medium Cylinder Track Head

Installation Instruction

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent round adjustable 800 Lumens

5-1/4" (134 mm) ø 4" (102 mm)

At125 Kopa Anti tamper ip65 reflector

Hornet 120. Track Head

WARNING Carefully Read These Instructions Before Use

SPEQ -S. Small Cylinder Track Head

Hornet 120. Track Head

A Bright Choice HEXALED. contrastlighting.com 1

Hydraulic Brake System, Bendix 42.26

EX3. Project Name _ K. R_x_ Rectangle. MAC JB Junction Box Movable AC

OUTDOOR TRACK. LABELS Assembled in America

ENLIGHTENING. LED High Bay. High Ceiling W. 73rd Street Bedford Park, IL Benefits. Markets & Applications

Downlighting. LyteCaster. Complete product = Frame-in kit + Light engine + Trim Order each separately. 3" Accent round adjustable 800 Lumens

Transcription:

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS Important THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Warning This product must be installed in accordance with National Electrical Codes and all other local codes by a person familiar with the construction and operation of the product and the hazards involved. To prevent electrical shock, turn off the power during installation or maintenance. To reduce the risk of fire, keep away from combustible materials. Product Overview The LumeLEX 2084 Series is LSI s highest power cylindrical unit. Capable of supporting up to 58W in a clean, elegant stem mounted fixture with a discreetly hidden driver. With independent ratings of 98 CRI, the LumeLEX 2084 Series, based on the latest in Remote Corrected Cold Phosphor Technology by Xicato, has the highest Color Rendering Index of any LED on the market today, producing the most consistent, highest quality white light and maintaining extremely tight color control (within 2 MacAdam ellipses, vs. the NEMA standard of 7). LumeLEX 2084 Series Spotlight See the fixture label for voltage and wattage input. Please consult our Product Catalog or web site for available accessories. We recommend that you first install the reflector and any accessories before installing the fixture. Purpose of This Sheet The purpose of this sheet is to provide step-by-step instructions to help you: Install accessory reflectors and accessory cartridge Install the fixture with any of the following: -00 fitting on an LSI track, -BUS fitting on an LSI Busway, 5A canopy, -2G universal flange fitting, or -3G C-Clamp fitting Aim the self-locking and wrench-locking fixture Service the 50,000 hour LED driver Dimming The LX2084 is fully dimmable using compatible trailing-edge, low-voltage electronic dimmers. Please review dimming application guide for detailed information and a list of compatible dimmers www.lightingservicesinc.com Page 1 of 9 IS-0196_~

Accessory Cartridge Overview The LumeLEX 2084 series fixture contains an accessory cartridge capable of holding Size C gels, and up to 3 Size C rimmed accessories. Installing Size C Accessories 1 Remove accessory cartridge by pulling on lip of cartridge (Fig. 1). 2 Insert the gels first (see pg. 3) and then 1 to 3 Size C rimmed accessories can be inserted (Fig. 2). 3 For orientation specific accessories such as a spread lens or Gel: Prior to fully reinserting the cartridge, turn fixture on and hold cartridge in front of fixture; rotate to orient beam as desired (Fig. 3). 4 Firmly push cartridge in until lip is fully seated on housing. Figure 1. Remove accessory cartridge by pulling on lip. Changing Accessories 1 Remove accessory cartridge by pulling on lip of cartridge (Fig. 1). 2 Change out accessories as desired. Accessories will pop out of retainer clip. Insert the gels, or up to 2 Size C rimmed accessories (Fig. 2). Follow steps 3 through 4 above Figure 2. Push accessory in so it lays flat and snaps into the retainer clip. Figure 3. If required rotate the Accessory Cartridge to aim an orientation specific accessory. www.lightingservicesinc.com Page 2 of 9 IS-0196_~

Backer Ring Overview The LumeLEX 2084 series fixture is capable of holding Size C gels. Typical Backer Ring and Gel insert are shown in Figure 4. See pg. 2 for removing and installing accessory cartridge. Installing Size C Gel 1 Remove accessory cartridge (Fig. 1) 2 Insert the desired Gel(s). 3 Insert Backer ring or rimmed accessory and push down on rim edge evenly with finger tips until it is seated flat on the bottom of the cartridge (Fig. 5). Up to 2 Size C accessories may be installed on top of Gels, if desired. Figure 4. Typical Backer Ring and Gel. Installing Size C Hood 1 Remove accessory cartridge (Fig. 1) 2 Insert the Hood. (Fig. 6) 3 Insert Backer Ring or rimmed accessory and push down on rim edge evenly with finger tips until it is seated flat on the bottom of the cartridge (Fig. 5). Several Gels and up to 2 Size C accessory may be installed on top of hood, if desired. Fully assembled Hood is shown in Fig. 7. Figure 5. Insert Size C Gel into Cartridge and push down on the edge of the Size C rimmed accessory or Backer Ring to support Gel or Hood. Figure 6. Place hood in cartridge and push down on edge Figure 7. Cartridge assembled with hood www.lightingservicesinc.com Page 3 of 9 IS-0196_~

Reflector Overview The LumeLEX 2084 series fixture is designed for use with interchangeable 20 /35 /60 LX-Mxx- REF (70mm) size reflectors and 15 /30 /40 LX- Jxx-REF (111mm) Before Installing the Fixture: The reflector is attached using a 3-tab bayonet system. To install the reflector, insert the tabs into the notches on the LED Adapter Ring and rotate clockwise. Changing the Reflector 1 Remove accessory cartridge. (Fig. 1) 2 Insert the new reflector by lining up the three tabs with the notches in the LED Adapter Ring, and rotating clockwise until it is secured in place. (Fig. 8) 3 Remove the reflector by turning it counter-clockwise, then pulling it out of the fixture (Fig. 9). 4 Install accessory cartridge. (Fig. 3) Figure 8. The three notches in the LED Adapter Ring. Align the reflector tabs with these notches and rotate clockwise to secure it in place. Figure 9. Rotate reflector counter-clockwise to remove it. www.lightingservicesinc.com Page 4 of 9 IS-0196_~

Installing the Fixture with the -00 Fitting on an LSI Track or a -BUS fitting on an LSI Busway FOR USE WITH LSI 3, 4, 5, 6, 8, AND 9 SERIES TRACK AND LSI 20 SERIES BUSWAY SYSTEMS ONLY. INSTALLATION INSTRUCTIONS: The track or busway must already be installed according to code requirements. When installing or using this track or busway system, basic safety precautions should always be followed, including the following: Read all instructions. Do not install any part of a track or busway system less than 5 feet above the floor (8 feet for 277 volt). Do not install any fixture closer than 6 inches from any curtain or similar combustible material. 1 Flip the fitting switch off and open the fitting handle (Fig. 10). 2 Are you using a one-circuit or two-circuit system? If one-circuit, make sure the brass contacts that protrude from the side of the fitting face the copper busbars inside the track or busway. If two-circuit, inserting the fitting in one direction connects to circuit one. Removing and reversing the direction of the fitting connects to circuit two. 3 Insert the fitting straight up into the track or busway until fully seated (Fig. 11). 4 Close the handle and flip the fitting switch on (Fig. 12). WARNING: Do not look directly at lit LED. 5 To remove the fitting, hold the fixture in place, flip the fitting switch off, open the handle, and pull the fitting straight off the track or busway. Figure 10. Fitting with switch OFF and handle OPEN. Figure 11. Inserted fitting Figure 12. Switch ON, fitting handle closed Installing the Fixture with a 5A Canopy Before Installing: Consult the code requirements for fixture mounting. Mount the fixture to a ceiling constructed of noncombustible material, away from any flammable materials. STEP ACTION 1 Turn off all power to the fixture mount. 2 Unscrew the 2 supplied canopy mounting screws, and remove the crossbar from the canopy (Fig. 13). 3 Attach the canopy crossbar (Fig. 14) to a ceiling junction box with 2 screws (supplied by others). 4 Fasten the power wires (Fig. 14) from the junction box to the fixture wires. Note: Connect green to ground, black to the circuit line, and white to neutral. 5 Attach the canopy to the ceiling with the 2 supplied canopy mounting screws. Figure 13. Fixture mounted on the 5A Canopy Figure 14. Ground and power wires with canopy crossbar www.lightingservicesinc.com Page 5 of 9 IS-0196_~

Installing the Fixture with a -2G Universal Flange Fitting or a -3G C-Clamp Fitting Before Installing: Consult the code requirements for fixture mounting, and check the distance-from-wall label inside the fixture. Mount away from any flammable materials. For the -2G fitting, follow steps 1, 2, 4, and 5. For the -3G fitting, follow steps 1, 3, 4, and 5. 1 Turn off all power to the fixture. 2 Attach the -2G fitting (Fig. 15) to any noncombustible material, using the 2-hole flanged mounting plate with 2 screws (supplied by others) or bolt-up applications, such as Unistrut or Kindorf systems. 3 Attach the -3G fitting (Fig. 16) to a noncombustible pipe measuring 5/8 to 2 in outside diameter, and then secure the fitting by turning the C-clamp bolt clockwise. 4 Plug the fixture into a power source. IMPORTANT SAFETY INSTRUCTIONS Never use with an extension cord unless the plug can be fully inserted. Do not alter the plug. 5 Turn on the main power, and then flip the fitting switch on. Note: The switch is located on the base of fitting. Figure 15. -2G universal flange fitting Figure 16. -3G C-clamp fitting www.lightingservicesinc.com Page 6 of 9 IS-0196_~

Aiming the Self- Locking and Wrench- Locking Fixtures NOTE: Allen key storage is only on Track and Busway Fittings. STEP ACTION 1 Turn off all power to the fixture, including the fixture switch on the fitting, and let the LED cool. WARNING: LED and fixture may be hot. 2 Do you want to aim the fixture horizontally or vertically? For horizontal aiming, hold the Fixture and turn it left or right until you achieve your desired orientation (Fig. 17). For vertical aiming, hold the Fixture and angle it up and down until you achieve your desired orientation (Fig. 18). For wrench locking: After aiming, insert the Allen key into the horizontal or vertical focus lock (Fig. 19), and turn it clockwise to tighten. Note: For track and busway fixtures, the Allen key is stored in the fitting handle (Fig. 20). 3 Restore power. WARNING: Do not look directly at the lit LED. Figure 17. Turn Fixture left or right to set the horizontal focus. Figure 18. Angle Fixture up or down to set the vertical focus. Figure 20. Allen key storage in fitting. Push in to secure the key. Figure 19. Horizontal focus lock (top arrow). Vertical focus lock (bottom arrow). www.lightingservicesinc.com Page 7 of 9 IS-0196_~

Replacing the LED Module If you need to change the LED Module, follow the steps below. 1 Remove all power to the fixture, including the fixture switch on the fitting, and let the LED Module cool. WARNING: LED Module and fixture may be hot. 2 Remove the reflector by turning it counter-clockwise, then pulling it off the fixture (Fig. 9) and setting it aside. 3 Remove the Adapter Ring by unscrewing the three screws securing it to the LED Module (Fig. 21). Pull the Adapter Ring off the fixture and set aside. 4 Remove the LED Module by unscrewing the three screws securing it to the Heat Sink (Fig. 22). 5 Remove 3 screws from the rear of the fixture to access electronics enclosure (Fig. 23). Pull out the wires and open the Quick Connect tabs to disconnect the LED wires from the circuit (Fig. 24). 6 Remove the old LED Module from the fixture. 7 Reconnect the new LED wires to the Quick Connect by lifting the tab and inserting the wire (Fig. 23). Note: Ensure that the wires are paired by color as black to black and red to purple. Note: The driver has two black wires: - Input black (line voltage), which is paired with white wire - Output black (low voltage/led power), which is paired with purple or colored wire 8 Install the new LED Module by firmly screwing the three screws to the Heat Sink (Fig. 22). 9 Reattach the Adapter Ring by screwing the three screws to secure it to the LED Module (Fig. 21). 10 Reattach the reflector by lining up the tabs with the notches in the LED Adapter Ring and rotating clockwise until it is secured in place (Fig. 8). 11 Restore all power to the fixture. WARNING: Do not look directly at the lit LED. Figure 21. The three screw locations for the Adapter Ring. Figure 22. The three screw locations for the LED Module. Figure 23. Remove 3 screws to access quick connectors and driver. Figure 24. A Quick Connector with tab lifted. Please refer to the label on the driver for wire orientation. www.lightingservicesinc.com Page 8 of 9 IS-0196_~

www.lightingservicesinc.com Page 9 of 9 IS-0196_~