Operation Instructions

Similar documents
operation instruction

DC-UPS INTRODUCTION SOME OF THE MANY APPLICATIONS:

Industrial Power Supplies

Power Supply EL

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Operating manual UPS - System

Power Supply EL

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Electronic Ballast EVG 2000-T

QUINT-PS/24DC/24DC/20

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

QUINT-PS/24DC/24DC/10

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Model Number Structure

MINI MCR-SL-UI-UI(-SP)

QUINT-PS/24DC/48DC/ 5

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

QUINT-PS/24DC/24DC/ 5/CO

Fuse state indicator MEg72. User manual

PowerScale kva Technical Specifications

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

User Manual Rittal PMC UPS 6kVA

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DC/DC converters - MINI-PS DC/ 5-15DC/

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

QUINT-PS/24DC/24DC/10/CO

Operating instructions Flow monitors SI / / 2010

TECHNICAL DATA SHEET KVA UPS Systemss

Safety technique. Emergency Stop Module BH 5928, BI 5928

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

MINI MCR-SL-UI-UI(-SP)(-NC)

Emergency lighting units EM converterled

All In one uninterruptible power supply solutions

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Electrical network protection VIP30, VIP35. User s manual 12/2008

SAVER DSP SERIES. 3-10kVA USER MANUAL

LIGHTNING PROTECTION UNIT (LPU)

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

Emergency lighting units EM powerled

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Emergency lighting units EM converterled

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Protection and control VIP30, VIP35. Relays technical manual

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

8. Filter / Autoranging Rectifier Module (FARM )

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

Operating instructions Flow monitors SI5000 SI / / 2007

Uninterruptible Power System

User Manual Solar Charge Controller 3KW

Phosphate-base Lithium-ion Battery Pack Model:LFP V 1350Ah Product Specifications Lithium Energy Solution 1/8

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Features. Description. Table of Contents

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

User Manual. Solar Charge Controller 3KW

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

PURE SINE WAVE DC TO AC POWER INVERTER

Operating Instruction Electric Quick-Closing Valve Systems

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

GFS - New Charging Technology

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Glossary/Technical appendix

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

EPS/ELA-Series User Manual EPS/ELA 250W

LV Capacitor CLMD03 Power Module Instruction manual

AWZ 110. AWZ 13,8V/1A/7Ah/LM

Low and High Voltage Power Supplies

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Uninterruptible Power System

BRAVER UPS. (Uninterruptible Power System) User s Manual

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

MODVAR Low voltage reactive power compensation modules Installation manual

BATTERY CHARGERS.

Automatic DC Power Supply/Battery Charger

XM1 - Motor protection relay

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Emergency lighting units EM converterled

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Technical data sheets

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Uninterruptible Power System

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

PowerScale TECHNICAL SPECIFICATIONS

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

LED FlatPanel Gen. 2. LED FlatPanel Gen. 2 ULTRA FLAT LIGHT PANEL. LED FlatPanel Gen. 2

Transcription:

Operation Instructions AKKUTEC 2405 USB NBPA0616G01 device designation notes art.no. nominal input voltage nominal output voltage AKKUTEC 2405-0 USB standard device, single module NBPA0616G01001 115-230V AC 24V DC AKKUTEC 1205-0 USB standard device, single module NBPA0616G01002 115-230V AC 12V DC AKKUTEC 4803-0 USB standard device, single module NBPA0616G01003 115-230V AC 48V DC 1/1 Technical modifications possible!

Safety regulations The operational instructions must be read and followed before the use respectively the installation of the device! In case of non-observance guarantee and warranty claims are no longer valid! The installation, putting into operation and maintenance may only be done by qualified personnel. The valid VDE-regulations, especially DIN VDE 0100 and EN 60204 are to be respected!! Incoming and outgoing feeders must be dimensioned and fused sufficiently (values see chapter 3.1)! The unit is a mount-in device. The operation is only permissible in dry rooms. The allowed environmental temperature range is to respected! Only the battery types specified for the unit are permitted to be used! Battery replacement is only to be made with the unit un powered! On the connection of external backup batteries, battery protection must be provided by the user! In this case the protection components (overload and short circuit protection!) must be installed as close as possible to the set of batteries for safety reasons! On the usage of batteries, sufficient air flow in accordance with VDE 0510, part 2 must be ensured. Never connect together new and used batteries, or batteries of different types, or from different manufacturers! The unit may only be opened by qualified personnel. In case of failure we recommend to send the unit back to the manufacturer. The disregard of the safety regulations may cause perilous injuries. 1. Concise description The battery backed DC power supply in the AKKUTEC range uses the standby-parallel principle of operation and, in conjunction with a lead accumulator, ensures that the DC power supply is reliably maintained in the case of a mains power failure. The back - up time depends on the state of charge of the accumulator and the discharge current. The power supply has the following features: battery charger system with I/U charging characteristics micro controller-based battery management Temperature compensation for charging voltage by means of external sensor module (optional module ). USB interface with appropriate driver unit and TECControl Software of J. Schneider, message contacts may be controlled and a shut down/re-start can be effected. 2. Norms and regulations power- HF- transmitter to ensure a safe separation primary / secondary opto coupler to ensure a safe separation primary / secondary emitted interference interference resistance: EN 61000-6-2 EN 61558 2-17 (VDE 0570 2-17) VDE 0884 EN 61000-3-2 and EN 61000-3-3 class A EN 55011 class B EN61000-4-2 (static discharge ESD) EN61000-4-3 (electromagnetic fields) EN61000-4-4 (fast transients / Burst) EN61000-4-5 (Surge) EN61000-4-6 (conducted interference resistance ) EN61000-4-11 (voltage drops) total unit EN 50178 / EN 60950 (4kV) (10V/m) input (2kV) output (1kV) mains (2 / 4kV) output (0,5kV) 10V, 150kHz 80MHz back-up with accumulator 2/2 Technical modifications possible!

3.1. Technical Data nominal input voltage 115-230V AC max. power loss input voltage range 97,75-264,5V 115V 15% - 230V + 15% worst-case leackage current 31W 0616G01DO1_engl-070326 <3,5mA input frequency 47-63Hz fusing input 250V 2,5A T (internal) 1) nominal input current 0,84A - 115V AC fusing (7.5A) / 6A T (external) 0,42A 230V AC DC- output circuit 1) max. inrush current 35A / 2ms fusing (7.5A) / 6A T (external) battery circuit output voltage 2405: type of connection input spring-type max. 2,5mm² ( without battery ) 26,8V DC ±0,4% mains output voltage 2405: ( with battery) 19,8V 26,8V DC±0,4% 1205: 9,9V 13,4V DC±0,4% final charging voltage 26,8V DC ±0,4% without temp.-sensor type of connection output Ua, Batt spring-type max. 2,5mm² (Temp.-Sensor optional) 27,0V bei 25 C with temp.-sensor charging charasteristics I/U DIN 41773-1 type of connection spring-type max. 1,5mm² messages deep discharge protection 2405: 19,8V DC ±0,4% type of protection IP 20 u. EN 60529 and load rejection at 1205: 9,9V DC ±0,4% nominal output current 5A DC weight 1kg I ANom current limitation 1,05...1,1 x I ANom storage temperature 0...50 C battery type lead accumulator, maintenance-free environmental temperature, recommended for battery 0-45 C 0-25 C efficiency Ua=26,8V DC, Ia= I Anom and Ue=230V AC 1) In case of FK2-fuses the values in brackets are valid typ. 88% dimensions 160 x 75 x 150mm (H x W x D) 3.2 Display and message outputs Ua mains OK 1) LED green, voltage is present at the output Ua LED green, illuminates at: mains operation, what means UE>U Emin potential free relais contact, change-over, max. contact load 30V DC/ 0,5A message with virtual Com-Port to USB: DCD enabled Batt OK 2) LED green, expires at: battery circuit interruption battery voltage < 21,6 V (battery operation ) battery temperature > 45 C LED green, blinks at: battery low battery damaged 1) The message contact is coupled with a LED di splay When the LED illuminates, the corresponding relay is enabled potential free relay-contact, nomally open, max. contact load 30V DC/ 0,5A message with virtual Com-Port to USB: CTS enabled 2) If the LED illuminates, the relay is active, the contact is closed. When the LED is blinking or expired, the relay contact is open 3/3 Technical modifications possible!

3.3 Message inputs Shut-Down Shut-down of the UPS operation, respectively switch off of the mains operation gate input referring to earth, switch level: 24V DC (6-45 V DC) 0616G01DO1_engl-070326 Shutdown via virtual Com-Port to USB: set RTS 3.4 USB-Anschluß This standard-usb-connection has potential separation from the mains and the DC-output. It can be connected to a PC with a normal USB cable. When a suitable driver is installed on the PC, the typical windows USB-plug-and-play software starts, after the connection. After the installation the AKKUTEC can be adressed with the means of a virtual COM_Port (Com1 Com255). The Com-Port can be chosen in the driver adjustments. With the Schneider-Software TECControl it is possible to: work up mains interruptions, for example start an external program (delayed). work up battery messages, for example shut-down the PC (delayed) It is also possible to analyse the RS232-signals CTS (Batt OK) and DCD (mains OK) by oneself and then for example to send back a shut-down signal with RTS to the AKKUTEC. 4. Installation The DC power supply is to be installed such that the necessary cooling is provided. A minimum separation of 40mm to neighbouring equipment or assemblies in the area of the ventilation open ings is to be maintained. The installation is always to be made in such a way that sufficient air circulation through the unit is ensured. The temperature of the cooling air at the bottom of the unit may not exceed the value provided in the technical data. The maximum mounting heights without load reduction is about 1000 m above N.N. During installation, the unit must be covered in such a way that no swarf from drilling can fall on or in the unit. ( Risk of short circuit!) 5. Connection Prior to connection, the values for the mains voltage and frequency as well as the values of the battery must be checked against the values on the rating plate. Connection in accordance with the labels on the connecting terminals. (See main block diagram and connector assignments). connection: terminal: connection: terminal: mains connection terminal connection mains L, N, PE (earth) control input Shut-Down terminal connection IO 3 +, 4 - DC-output (load) terminal connection Ua +, -, - (Minus is exists two times) mains OK mains present mains interruption I/O 6 / 7 (closed) 5 / 7 (closed) lead battery battery- temperature sensor (optional module) terminal connection Batt +, - terminal connection I/O 1, 2 Batt OK I/O 8 / 9 (closed) In the case of overload, the DC output current comprises the maximum current charging rectifier current as well as the battery current. To prevent overload of the DC output circuit, the circuit is to be protected externally! (Value see Section 3.1) 4/4 Technical modifications possible!

6. Circuit diagramm 7. Putting into operation The unit is switched on by the switch on of the mains voltage. If the units are built into systems, which must be tested with over voltages (for example according to EN60204-1 / VDE0113 part1 19.4 voltage test), the unit must be separated from the test assembly before the voltage is switched on. (Original text EN60204-1 : parts, which are not dimensioned for the testing voltage, must be separated during the test.) The battery voltage must match the nominal voltage of the AKKUTEC! Never reverse the poles of the battery! Never short circuit batteries! Risk of arcing! Check the connections for correctness prior to switching on for the first time Only make electrical connections with the unit un powered 5/5 Technical modifications possible!

8. Operation 0616G01DO1_engl-070326 Approx. 2s after the switch on of the mains, the output voltage is enabled and the loads connected are supplied with power. The back up battery is also charged. This operating mode is indicated by the illumination of the green LED Netz ok (mains operation). When the output voltage increases the LED Ua, which is coupled to the output, illuminates. This LED illuminates as long as voltage is present at the output, as well when the voltage is provided by the battery or another external supply. When the mains voltage is switched off or when the voltage drops under the minimum input voltage the AKKUTEC switches to battery operation. The green LED Netz ok (mains operation) expires. The illumination of this LED always results in the energisation of the corresponding signal relay Netz OK (mains operation). (See block diagram, Section 6) 9.1 Battery Circuit Monitoring After switch-on the unit, at first the LED Batt OK illuminates. The corresponding message relay is enabled, the contact is closed. To ensure the back-up capability, the battery circuit is tested cyclically each 60s; the first test is performed 60s after mains switch on. By means of this test it is possible to identify an open circuit or the high impedance of the battery circuit. A defective battery circuit is indicated by the expiring of the green LED Batt OK. The corresponding message relay is inactive, the contact is opened. Possible causes: battery not connected, current circuit interrupted, battery defective, external fusing at the battery circuit defective. 9.2 Battery Test During mains operation, a cyclic battery test loads the battery whilst the voltage is measured. In this way it is possible to evaluate the quality of the battery. A seriously aged battery is indicated by the blinking of the green LED Batt OK. Approximately 1 hour after mains switch-on the first battery test is made, each other after 24 hours. F With the processor controlled automatic battery test, the back-up capability of the battery is ensured. To evaluate the capacity of the batteries we recommend additionally to check the batteries with the nominal load current at least one time each year. Therefore battery operation is enforced by mains switch off and the back-up time is measured until automatic switch off (deep discharge limitation). The actual battery capacity can be evaluated from the back-up time and the nominal load current. If the capacity of the batteries is not sufficient for the necessary backup time, the batteries must be exchanged. 9.3 Shut-Down To avoid the discharge of the battery until the deep discharge limitation, it is possible to abandon the battery operation with an external signal. This is effected by connecting a +12V/+24V DC control voltage at terminal 3 (+) and 4 (-) at the terminal strip IO. Additionally a shut-down signal can be given over the serial interface via USB (RTS signal of the virtual RS232, for example with the J. Schneider TECCONTROL Windows Software). 6/6 Technical modifications possible!

9.4 Temperature Compensation (optional module) Lead batteries have a temperature coefficient of approx. -3mV per C and cell. The AKKUTEC final charging voltage is selected such that battery charging is provided over a temperature range of 15-45 C. In applications with frequent and large temperature variations, the charging voltage should be appropriately compensated to achieve optimal battery life. Also, particular ly in the case of very low environmental temperature (Tu < 15 C), compensation should be performed to ensure adequate battery charging. By connecting the external temperature sensor module (option) to terminal strip IO -1 connection 1 and 2 (note poles!), temperature compensation is automatically activated. For an surrounding air temperature variation of 0-45 C, the final charging voltage (and thus also the output voltage) varies over a range of 27. 85-26.3 V DC Battery temperatures above 45 C are indicated by the expiring of the LED Batt OK.. F To obtain satisfactory battery life, the operating temperature of the batteries should not exceed 25 C. Higher temperatures lead to a reduction in the lifetime! 10. Taking out of operation The unit is taken out of operation by removing the mains supply. To prevent subsequent backup from the batteries, the battery circuit must be opened by activating Shut -Down. (See Section 9.3). The LEDs Netz OK and Batt OK must expire. (s. Punkt 9.3). Never undo electrical connections whilst the unit is in operation! It also not permitted to make electrical connections whilst the unit is in operation! 7/7 Technical modifications possible!

11. Installation drawings snap fixation for 35 mm Normprofilschienen DIN EN 50022 (NS 35 x 15 / 7,5mm) Netz L N Ua Netz OK Batt OK 160 1 2 3 4 5 6 7 8 9 I/O Batt USB Ua 75 Tiefe: 150mm Depth: 150mm 12. Maintenance Inside the unit there are no parts which may be maintained by the user. The unit is to be cleaned regularly, depending on the degree of soiling The batteries must be checked as described in section 9.2 and must eventually be exchanged. 8/8 Technical modifications possible!