JM - Junction Enclosure Modules for Communication Networks

Similar documents
Quartz. Save Space with Low Profile Design

Installation Manual OPEN. For Corrosive Service. The ONYX integrates electronic sensors and pneumatic valving into a vapor tight enclosure.

Quartz Explosionproof valve monitoring

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

EG Series Installation Manual

LIMIT SWITCH Axiom - AX

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

valve communication and control

LIMIT SWITCH Prism - PI

Quartz Explosionproof valve monitoring

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

LIMIT SWITCH Axiom - AX

LIMIT SWITCH Axiom - AX

Description. Fieldbus Optimized Through Junction Boxes

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Quartz Explosionproof valve monitoring

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Valve Control Solutions

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Eclipse Compact and modular with solid state reliability

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

CRANE Limit Switches. CCR Series. CXA Series. CCA Series

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

PISTON STYLE GAUGE. Mid-West Instrument

Prism PI Intelligent features offer advanced performance

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Accord DS/DM Series UltraSwitch Switch box

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

CYCLOPS Z Purge Indicator

CYCLOPS X Purge Controller XP Version

SKINNER Intrinsically Safe Series Four-Way

CML Electric Actuator for Baumann Series

General purpose / hazardous area

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Valve Position Monitors

Assembly. Trunk IN + - S U, I U, I. Spur 1

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

APG. Explosion Proof and Non-Incendive Magnetostrictive Level Sensors Series: MPX. Features

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

ALS SERIES VALVE MONITOR ATEX. Exd

Flow-Alert Flow Switches (Micro Switch)

Diaphragm Type Differential Pressure Gauges Switches & Transmitters Model 140

ValvePoint: valve communication and control

valve communication and control

Certificate of Compliance

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

Magnetic Level Gauges

Product Specification

Lighting and Power Distribution Panelboards

Automation Selection Guide

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Linear Position Indicator Bracket Mounted for Linear Actuators Resin Body

HKC HM- Series Electric Valve Actuators HM- Series

ARCAPRO positioner. Positioner customized for specific tasks

Series Village Lane Easley, SC Ph: (864) Fax: (864) Worm and Spur Gear Electric Actuators

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

Features. Flexibility

Valve Position Monitors

PIT, PIF & PIX Pressure-to-Current Transmitters

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

Shock/Vibration Control Switches

CYCLOPS Z Purge Indicator

VALVE ACCESSORIES & CONTROLS V200 POSITIONER A POSITIONER THAT OFFERS IT ALL IN ONE COMPACT, SIMPLE, HOUSING

AXIOM AN SERIES VALVE COMMUNICATION AND CONTROL NONINCENDIVE & I.S. ON/OFF VALVE CONTROLLER. on-off controller AXIOM AN

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

Axiom Explosionproof Advanced performance and reliability in harsh environments

LIMIT SWITCHES & POSITION INDICATION

POSITIONERS and Controls for Complete Valve Automation

Metso valve controls Product offering. Comprehensive offering to suit your every need. For North America markets only

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter. Min.

TSRT TSRT Tee Splice Kit Installation Instructions

Division 1 Explosionproof Panelboards

The products you need when you need them.

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

VALVES / ACTUATORS COMPLETE PRODUCT LINE / BRAYLINE ACCESSORIES. The High Performance Company

2006/2007 Product Catalog. The World s Leading SOLAR Controllers

ELECTRIC ACTUATORS. Series 70 Pgs 4-11 PRODUCT QUALITY & PRECISION INTRODUCTION

brands you trust. CRANE - Automation Actuators and Instrumentation

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Explosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst

PMV WS/WM Series UltraSwitch

Plugs and Receptacles: Hazardous Location

EH Range Technical Data

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

Quarter turn actuators Index

V200 Series Positioners

short form catalog SFC 07

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

CYCLOPS Y Purge Indicator

Transcription:

Pub #110014revB, Part 1-12/2002 JM - Junction Enclosure Modules for Communication Networks Installation & Adjusting Instructions for JMT, JMP, JMS, JMD, JMB series The JM provides a watertight / explosion proof enclosure for a wide variety of fieldbus drop connectors. Passive, Protected, or Switched Mounting The JM Enclosure 1. Locate the position where the JM enclosure will be mounted. Ensure that there is sufficient room to operate the disconnect switch levers and to remove the cover. 2. Attach the JM enclosure to a wall or other stationary flat surface using the mounting holes provided. 3. Secure the cover until hand tight Attaching Conduit and Fittings 1. Conduit entries are provided for the convenient attachment of threaded conduit and threaded conduit fittings. Attach threaded fittings and conduits securely. 2. Follow all applicable NEC codes and other regulations. Installing & Removing Cover 1. To insure NEMA 4, 4X, 6 and hazardous location ratings are maintained the cover must be completely closed and the O- Ring sealed to keep out water. JM Dimensions (in mm) Standard Enclosure Switched Enclosure Enclosure w/ Cyclone Valve StoneL Corporation One StoneL Dr 26275 US Hwy 59 Fergus Falls, MN 56537 USA 2001 StoneL Corporation Telephone: 218.739.5774 Toll Free: 800.843.7866 Fax: 218.739.5776 E-mail: sales@stonel.com Website: www.stonel.com

JM JM Model Options Example: Function T00 (1-1) Passive drop connector for 2 wire T01 (1-2) Passive drop connector for AS-I T03 (1-2) Passive drop connector for DeviceNet T05 (1-2) Passive drop connector for Modbus, DP T07 (1-2) Passive drop connector for FF-H1, PA P01 (1-1) Protected drop connector for FF-H1, PA (40mA) P03 (1-1) Protected drop connector for AS-I (240mA) S01* (1-1) Switched protected drop connector for FF-H1,PA (40mA) S03* (1-1) Switched protected drop connector for AS-I (240mA) S11* (1-1) Switched passive drop connector for DeviceNet D00 2 (1-1) Passive drop connectors for 2 wire D11 2 (1-1) Protected drop connectors for FF-H1, PA (40mA) D13 2 (1-1) Protected drop connectors for AS-I (240mA) B06 6 Pole Terminal Block B12 12 Pole Terminal Block 000 Housing only JMT0111E3 Solenoid 11 No Solenoid Enclosure C Clear Cover E Epoxy Coated Aluminum Pub #110014revB, Part 1-12/2002 page 2 Conduit Entries 3 (3) 1/2 NPT N (4) 1/2 NPT 6 (3) M20 M (4) M20 Z Potted Leads Note: Consult factory for sealed leads on drop leg of disconnect switch for Division 1 areas. * Switched protected drop connector available only with conduit Option 3 General Specifications Operating Life Unlimited Materials of Construction Housing and Cover Marine grade anodized aluminum epoxy coating Clear Cover Lexan Polycarbonate Elastomer Seals Buna-N Fasteners Stainless Steel Warranty Complete Assemblies Two Years Lexan is a registered trademark of General Electric Corporation. Temperature Range -40 to +85 C (-23 to 185 F) Enclosure Protection NEMA 4, 4X & 6; IP67 Hazardous Area Ratings Explosion Proof (Aluminum Cover) Class I, Div. 1 and 2, Groups B,C,D Class II, Div. 1 and 2, Groups E,F,G Non-incendive (Clear Cover) Class I, Div. 2, Groups A,B,C,D Class II, Div. 2, Groups E,F,G (Not all units carry approvals, consult factory)

page 3 - Bus in, Bus out, (1) Drop for 2 wire networks JMT00 JMT01 - Bus in, Bus out, (2) Drops for AS-Interface networks and other 2 wire networks - Bus in, Bus out, (2) Drops for DeviceNet networks JMT03 - Bus in, Bus out, (2) Drops for Modbus, Profibus-DP amd other 2 wire networks with seperate power bus JMT05 V- S L H V- L S H V- S V- S S V- H L S V- H L S V- S V-

page 4 - Bus in, Bus out, (2) Drops for Foundation Fieldbus H1 and Profibus-PA networks JMT07 JMP01 Protected Drop Connector - Bus in, Bus out, (1) Drop for Foundation Fieldbus H1and Profibus-PA networks 9-32 VDC (F/F Voltage) (Trunk) 40 ma JMP03 Protected Drop Connector - Bus in, Bus out, (1) Drop for AS-Interface networks AS-Interface Voltage (Trunk) 240 ma 1.0 Volt Max JMS01 Switched Protected Drop Connector - Bus in, Bus out, (1) Drop for Foundation Fieldbus H1and Profibus-PA networks - Disconnect drop from bus. 9-32 VDC (F/F Voltage) (Trunk) 40 ma

page 5 JMS03 Switched Protected Drop Connector - Bus in, Bus out, (1) Drop for AS-Interface networks - Disconnect drop from bus. AS-Interface Voltage (Trunk) 240 ma 1.0 Volt Max Switched - Bus in, Bus out, (1) Drop for DeviceNet networks - Disconnect drop from bus. JMS11 24 VDC (DeviceNet Voltage) 1.0 Volt Max V- L S H H S L V- V- S L H s - (2) Bus in s, (2) Bus out s, (2) Drops for 2 wire systems - Provides for easy spur wiring and branching from the trunk JMD00 JMD11 Protected Drop Connectors - (2) Bus in s, (2) Bus out s, (2) Drops for Foundation Fieldbus H1and Profibus-PA networks - Short circuit protection on drop. LED indicates drop fault. 9-32 VDC (F/F Voltage) (Trunk) 40 ma 1.0 Volt Max

page 6 JMD13 Protected Drop Connectors - (2) Bus in s, (2) Bus out s, (2) Drops for AS-Interface networks - Short circuit protection on drop. LED indicates drop fault. AS-Interface Voltage (Trunk) 240 ma 1.0 Volt Max 6 Pole Terminal Block - Provides convenient termination points in a rugged junction box - Accepts up to 12 AWG wire or (2) 14 AWG wires Voltage JMB06 0-300 VAC/VDC 20 amps 1 2 3 4 5 6 JMB12 12 Pole Terminal Block - Provides convenient termination points in a rugged junction box - Accepts up to 12 AWG wire or (2) 14 AWG wires Voltage 0-300 VAC/VDC 20 amps 1 2 3 4 5 6 7 8 9 10 11 12