urlington 50mm close coupled cistern tank with back and bottom entry water supply with lever flush urlington Extended depth 50mm close coupled cistern tank with back and bottom entry water supply with lever flush 4 0 Parts supplied: Please read these instructions carefully to avoid damage to the valves, and to ensure correct installation. Inlet Valve Plug Lever olt x Plastic one one one Do not use bleach or bleach based cleaning products in the cistern, as these will cause damage to the seals. We cannot be held responsible or liable for any failure which results from the use of bleach based products. Water temperature range + to +45. Water pressure 0. to 8 bar. : installation Overflow pipe valve base ody Seat Screw down the nut and take off the washers. Plastic washer Insert flush valve base attached with rubber washer into cistern flush hole. Then install the rubber washer, plastic washer, and tighten the fixing nut. - 5
: scale and adjustment setting Note: The should be adjusted for the required flush volume. The diagram A below indicates the correct setting for 6L full flush and L half flush. The diagram below indicates the correct setting is for 4.5L full flush and.6l half flush. 4 urlington 50mm close coupled cistern tank A 6L full flush and L half flush 4.5L full flush and.6l half flush Half flush float Move float down, flush volume increases. Half Float : should be set on the mark. Half Float : should be set on the.5 mark Full Adjustor : should be set on the 5.5 mark Full Adjustor : should be set at mark. Half Adjustor : should be set at.5 mark. Half Adjustor : should be set at.5 mark 0 urlington Extended depth 50mm close coupled cistern tank A 6L full flush and L half flush Half Float : should be set on the.5 mark Full Adjustor : should be set on the 5 mark Half Adjustor : should be set at.5 mark Half flush adjustor Move adjustor down, flush volume increases. 4.5L full flush and.6l half flush Full flush adjustor Half Float : should be set on the mark Full Adjustor : should be set on the 5mark Half Adjustor : should be set at 4.5 mark Move adjustor down, flush volume increases. : Installation Option for lose coupled or Low level Low Level Installation lose oupled Installation ody Please use the plug to block the bottom inlet hole. Valve one istern Please use the plug to block the bottom inlet hole. rass nut Push the flush cone over the fixing nut, ensure that it is flat, and there is no leakage between cistern and pan. Use the two white bolts to block the two installation holes. Use the brass nut from Low Level kit to fix the. 4: trouble shooting Problem Leakage No flush, low flush or half flush volume Half flush water level is too high or too low. Reason Solution.Incorrect installation.. valve seat does not fit flush valve body.. valve body is stuck..install again according to the correct installation procedure..install again..disconnet and wash flush valve body. able is distorted. Water level is adjusted incorrectly. Remove kinks or sharp bends in the cable. Adjust water level. -5
6 4 0 8 6 4 0 6 4 0 8 6 4 0 : Inlet Valve adjustment settings and Installation 4 urlington 50mm close coupled cistern tank 6 4 Adjust the scale to 6. 0 urlington Extended depth 50mm close coupled cistern tank 6L full flush and L half flush, Adjust the scale to 6. 4.5L full flush and.6l half flush Adjust the scale to. "6" scale 6 4 "6" scale Fixing rod Loosen the fixing rod. istern Fixing rod Overflow pipe Fix the inlet valve onto the overflow pipe, and tighten the fixing rod. Adjustment Rod onnect the water supply pipe to the supply end. Open the water supply, heck if the inlet valve works well. If required, the water level could be adjusted. Adjusting the rod: A: y adjusting clockwise the water level rises and the flush volume increases. : y adjusting anti-clockwise the water level falls and the flush volume decreases. : Filter cleaning (Please clean periodically) istern Inlet valve Inlet pipe Filter Inlet valve istern lose the water supply, and take off the inlet valve. : Inlet Valve trouble shooting Problem Incorrect water level Inlet Valve does not work Reason Incorrect adjustment. Water supply is closed. The filter is blocked. Screw down the fixing nut, and take off the water supply pipe. Filter lean by rinsing the filter. lean the filter. Solution Adjust the Water. level correctly. Open the water supply Reinstall the inlet valve. Leakage The Stop Float is pressed by the tank.. The Inlet Valve fixing nut has not been tightened. Readjust the direction of the inlet valve. Tighten the nut. - 5
: Install lose oupled istern To Pan lose oupled istern & Level Installation * Please ensure the flush cone is in position before installation. Plastic washer Install the cistern as shown and tighten the fixing nuts. onnect the water supply to the cistern. : Install Lever utton ox Pull Plastic Rubber Insert the box and tighten the nut. * Raise the lever so that it fits into the flush box in the correct position. Nut Anti-rotation Lever * The fixing nut should be tightened as much as possible to avoid the cistern lever working loose during operation. * Make sure the cable is not distorted or kinked. istern Lever Hole Direction Slot In The Thread * With the lever facing outward and the slot on the thread facing upwards, fix the lever to cistern. * The overflow pipe of flush valve may be cut down depending on the installation on site. Please ensure the fill rate of the cistern does not exceed the flow capacity of the overflow pipe. Note: After installation check that the full flush and half flush are working correctly. Please consult the trouble shooting pages if there are any problems. 4-5
Low Level istern Installation Note: Please carefully check for leaks after installation. Please use two white bolts to block the two fixing holes on the bottom of cistern, cut the bolts to suitable length if necessary. 5-5 Outlet one Sha p e d W as h e r Plastic Decorative over Pipe one Inlet Hole istern Pan