Agilent InfinityLab Quick Change Valve G4237A

Similar documents
Agilent G4239C Valve Kit - Instructions

Agilent G4236A 2D-LC Valve Installation Guide

Agilent Online-SPE Direct Inject Kit G4744A

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent InfinityLab Quick Change Valve G4235A Instructions

Agilent G5632 Valve Kit Instructions

Agilent Valve Kit G4231A/B/C and G4232B/C/D

1260 Infinity II Multicolumn Thermostat

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

Dual-Needle Infinity II Upgrade Kit

Agilent InfinityLab LC Series Multi-wash Upgrade Kit

Agilent 1290 Infinity Autosampler

Agilent SD-1 Purification System ml/min

Agilent 1290 Infinity II Ultra Low Dispersion Kit

Agilent 210/218 - Isocratic Pump

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

G1160A Agilent 1100 Series Multiple Purpose Switching Valve

Agilent 210/218 - Binary Pump

CHROMATOGRAPHY. SYKAM S 6000 Valve Series

Agilent 1200 Series Valves

Agilent 1200 Series Thermostatted Column Compartment G1316A/G1316B/G1316C

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Agilent 1200 Series Manual Injector

HIGH PRESSURE SWITCHING VALVES

10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual

Agilent 1260 Infinity Manual Injector

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

1260 Infinity II Degasser User Manual. 5 Maintenance

Agilent 1260 Infinity Standard Autosampler

Agilent 1100 Series Thermostatted Column Compartment. Reference Manual

FITTINGS, LOOPS, AND VALVE ACCESSORIES

Agilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

Agilent 1260 Infinity Bio-inert Manual Injector

Agilent 218 Purification Solution

One-Piece UPchurch Fingertight Fittings 1,2. ChromTRAC. TOP SELLER see starred products in price block. Fingertight Fittings.

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Your Essential Resource for INFINITYLAB LC SUPPLIES

Ultra High Performance Fittings. Fittings Connectors Kits

Technical Procedure for Gas Chromatography (GC-FID)

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

High Pressure Valves. MX Series II Modules Manual Sample Injection Switching

Customer Information. Service Engineer s Responsibilities. Agilent Cary 7000 UMS/UMA/Solids Autosampler

Agilent 1200 Series Standard and Preparative Autosamplers

System Manual. Agilent 1260 Infinity Capillary LC System

Agilent 1290 Infinity Quaternary Pump

For more information about Agilent Technologies services please visit our web site using the following URL

Agilent 1200 Series Nano Pump

Agilent 1290 Infinity Quaternary Pump

Agilent 1260 Infinity Binary Pump VL

Agilent 1290 Infinity Binary Pump

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Agilent 1100 Series Capillary LC System. System Manual

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Fittings SECTION 1 OF 4 SECTIONS ON FITTINGS

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

78 동방하이테크상사 T.(02) F.(02)

Quick Reference Guide. Supplies for Waters HPLC Systems

1350 Valves. 1 of 14. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Installing a Purged Packed (PP) Inlet

Agilent 1260 Infinity Capillary Pump

850 Professional IC. AnCat MCS Manual EN

Replacing the Column Stabilizer Tube with Finger-tight Fittings

Installation Guide Thermal Conductivity Detector Accessory 19232E

1110 Valves. Introduction

Agilent 1260 Infinity Quaternary Pump VL

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Fixed Flow Splitter *

NEW HPLC - SYSTEM LINE

Agilent 1260 Infinity Bio-inert High Performance Autosampler

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

MPP 910 IDS MPP 930 IDS

1260 Infinity II SFC System

98 동방하이테크상사 T.(02) F.(02)

QuickSplit TM Flow Splitters

Section 8. Parts A8EN -09 -[AD -31SW/WP] AD31SW--MA--02 (formerly ) Issued 12/95. E 1995 Nordson Corporation All rights reserved

Motor Valve MV-7/IMV-7

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Simplify your search for. You will find both PEEK-lined stainless steel hardware as well as standard ss column hardware at the below stockingstations.

Physiological Calibration Standard II Calibration standard physiological fluid CALIBRATION STANDARD PROTEIN

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Technical Overview. Introduction

2017 HPLC Product Catalog 1

GE Healthcare. Valve INV-917. Instructions

When installing the screwed end, socket weld & flanged end valves the following respective procedures shall be followed for better performance.

Instrument Accessories & Parts, Tubing & Connections

Agilent 7693A Automated Liquid Sampler

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

MP18 Stacking Valve System Technical Information Manual

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

Installing a Purged Packed Inlet

HP 1946A LC/MSD Replacement Parts

Agilent 7693A Automated Liquid Sampler

Transcription:

Agilent InfinityLab Quick Change Valve G4237A Instructions Agilent G4237A Valve Kit Instructions This technical note describes the installation and application of the Agilent InfinityLab Quick Change 4 column selector Valve Head G4237A in a 1260/1290 Infinity II Multicolumn Thermostat (MCT). Contents Typical Applications 2 Multicolumn Selection 2 Method Development 3 Delivery Checklist 3 Install the Valve Heads 6 Remove the Transportation Lock and the Valve Dummy 6 Install the Valve Head and Connect Capillaries 8 Install the Capillaries 12 Setup Examples 14 Valve Specifications 15 Valve Parts 15 Agilent Technologies

Typical Applications Multicolumn Selection Advantages Increase productivity Higher instrument up-time The valve facilitating quick changes allows the selection between up to four different stationary phases for a variety of applications, or the usage of identical stationary phases in columns with different dimensions for either faster run-times (short columns) or higher resolution (long columns) or for loading studies with different internal diameters. Figure 1 The G7116A 1260 Infinity II Multicolumn Thermostat equipped with an InfinityLab Quick Change 4 Column Selector Valve Head 2

Method Development Advantages: Faster method development Automated method development possible Figure 2 Totally different chromatographic results by using the same sample but three different stationary phases Delivery Checklist Check the content of the delivery. You should have received the following: G4237A: p/n Description 5067-4279 4 column selector valve head, 800 bar 5067-6596 Cap kit 0.12 mm, 4-col, incl. QC-HE (Optional) 5067-4300 Cap kit 0.17 mm, 4-col, incl. QC-HE (Optional) 3

The different Capillary Kits for the 4-Column Selector contain the following parts: Capillary Kit (5067-6596) # p/n Description 4 G7116-60015 Heat Exchanger Assembly 1.6 µl-z Quick Connect Heatexchanger Standard Flow 4 G7116-68003 Column Holder Clips (2/Pk) 1 5500-1202 Capillary ST 0.12 mm x 500 mm M4-SL PS-PS autosampler to valve 4 5500-1199 Capillary ST 0.12 mm x 130 mm M4-SL PS-PS valve to heat exchanger 4 5500-1200 Capillary ST 0.12 mm x 130 mm SL/M column to valve 1 5063-6591 PEEK Fittings 10/PK column outlet 4 5500-1201 Capillary ST 0.12 mm x 105 mm SL-- PS-LS heat exchanger (PS-SL) to column 1 5500-1203 Capillary ST 0.12 mm x 280 mm M4-SL PS-PS valve to detector 1 5500-1204 Capillary ST 0.12 mm x 150 mm M4-M4 PS-PS valve to valve (column bypass) 8 G1314-68703 Cap fitting kit special 1 5023-2504 Hex driver SW-4 slitted 1 5067-6141 M4 Blank nut 1 G1375-87326 Waste tube 4

Capillary Kit (5067-4300) # p/n Description 4 G7116-60051 Quick-Connect Heat Exchanger Large ID, Standard Flow 4 G7116-68003 Column Holder Clips (2/Pk) 1 5067-6188 Capillary ST 0.17 mm x 500 mm SL-M4 PS-PS autosampler to valve 4 5067-5109 Capillary ST 0.17 mm x 90 mm SL/M valve to heat exchanger 4 5067-4746 Capillary ST 0.12 mm x 250 mm SV/M long column to valve 4 5500-1200 Capillary ST 0.12 mm x 130 mm SL/M short column to valve 2 0100-1516 Fitting male PEEK, 2/pk column outlet 4 5500-1193 Capillary ST 0.17 mm x 105 mm heat exchanger to column 1 5500-1203 Capillary ST 0.12 mm x 280 mm M4-SL PS-PS valve to detector 1 5500-1204 Capillary ST 0.12 mm x 150 mm M4-M4 PS-PS valve to valve (column bypass) 1 5065-4454 Fitting screw long 10/pk 1 5023-2504 Hex driver SW-4 slitted 1 5067-6141 M4 Blank nut 1 G1375-87326 Waste tube 4 G1314-68703 Cap fitting kit special Capillary and Fitting Information M4 = fitting thread size for micro valve ports PS = pre-swaged fitting NS = non-swaged fitting SL = fitting screw long LS = long capillary socket (required for special fittings as the A-Line Quick Turn Fittings) SV = removable high pressure fitting 5

Install the Valve Heads The valve drives are factory-installed in the Multicolumn Thermostat. The valve heads are interchangeable and can be easily mounted. At the first installation, the transportation lock and the dummy valve have to be removed, see Remove the Transportation Lock and the Valve Dummy on page 6. The valve heads can be installed by mounting the valve heads onto the valve drives and fastening the nut manually (do not use any tools). Be sure that the guide pin snaps into the groove of the valve drive thread. The valves are mounted on pull-out rails to allow easy installation of capillaries. Push the valve gently into its housing until it snaps into the inner position, push it again and it slides out. When all capillaries are installed, push the valve back into its housing, see. Remove the Transportation Lock and the Valve Dummy The following procedure demonstrates the necessary steps for installing the valve head to the valve drive of a Multicolumn Thermostat (MCT). For the installation of a valve head to a G1170A Infinity Valve Drive you can ignore the steps that describe the MCT features of the transportation lock and spring loaded valve drive. 1 Switch off the module. 2 When unscrewing the transportation lock, push it back until the last screw is removed - the valve rail is spring-loaded. 6

3 Press on the valve dummy (1.) to release it (2.) (spring-loaded valve rail). 4 5 7

Install the Valve Head and Connect Capillaries CAUTION The valve actuator contains sensitive optical parts, which need to be protected from dust and other pollutions. Pollution of these parts can impair the accurate selection of valve ports and therefore bias measurement results. Always install a valve head for operation and storage. For protecting the actuator, a dummy valve head can be used instead of a functional valve. Do not touch parts inside the actuator. CAUTION Column Damage or Bias Measurement Results Switching the valve to a wrong position can damage the column or bias measurement results. Fit the lobe to the groove to make sure the valve is switched to the correct position. CAUTION Valve Damage Using a low pressure valve on the high pressure side can damage the valve. When using multiple column compartments as part of a method development solution, make sure that the high pressure valve head is connected to the autosampler and the low pressure valve head is connected to the detector. CAUTION Wrong combination of fitting with valve The InfinityLab Quick Turn fitting (5067-5966) is not compatible with the G5639A Bio-inert 4-Column Selector Valve. Misuse can lead to extra dead volume and leaks. As fitting, use UHP fitting (5067-5403) instead. 8

For information about the compatibility mode of 800 bar valve heads see Information on RFID Tag Technical Note (01200-90134). For a correct installation of the valve head, the outside pin (red) must completely fit into the outside groove on the valve drive s shaft (red). A correct installation is only possible if the two pins (green and blue) on the valve head fit into their corresponding grooves on the valve drive s actuator axis. Their match depends on the diameter of the pin and groove. The tag reader reads the valve head properties from the valve head RFID tag during initialization of the module. Valve properties will not be updated, if the valve head is replaced while the module is on. Selection of valve port positions can fail, if the instrument does not know the properties of the installed valve. To allow correct valve identification, power off the valve drive for at least 10 s. For firmware requirements see Information on RFID Tag Technical Note (01200-90134) which is included to each valve head. 9

1 Insert the valve head into the valve shaft. OR If the outside pin does not fit into the outside groove, you have to turn the valve head until you feel that the two pins snap into the grooves. Now you should feel additional resistance from the valve drive while continuously turning the valve head until the pin fits into the groove. 10

2 When the outer pin is locked into the groove, manually screw the nut onto the valve head. Fasten the nut manually. Do not use any tools. 3 Install all required capillary connections to the valve. 4 Push the valve head until it snaps in and stays in the rear position. 5 Power on or power-cycle your module, so the valve head gets recognized during module initialization. 11

Install the Capillaries CAUTION Damage to the rotor seal Instant pressure release within the valve will lead to water jet effects that can harm internal parts of the valve. This pressure release typically happens if the valve gets switched under high pressure over unused or open channels. Block all unused channels properly with the M4 blank nut. To minimize valve movement over open connections it is recommended to plumb the column connected channels in one row. e.g.: channel 1 column 1 channel 2 column 2 channel 3 blocked channel 4 waste The blank nuts are only required for the ports on the inner circle that connect the valve with the column inlet. 1 Install the In and Out connectors. from sampler to the valve ( Capillary ST 0.12 mm x 500 mm M4-SL PS-PS (5500-1202)) or on a standard system (with 0.17 mm capillaries) Capillary ST 0.17 mm x 500 mm SL-M4 PS-PS (5067-6188) from valve to the detector ( Capillary ST 0.12 mm x 280 mm M4-SL PS-PS (5500-1203)) The In port is hydraulically connected to the column inlet ports 1-4 while the Out port connects to the column outlet ports 1`-4`. 12

2 Install the column inlet and outlet connections. - ports 1-4 for connections from valve to the heat exchanger ( Capillary ST 0.12 mm x 130 mm M4-SL PS-PS (5500-1199)) or on a standard system (with 0.17 mm capillaries) Capillary ST 0.17 mm x 90 mm SL/M (5067-5109) or waste line (Waste tube (G1375-87326)) - ports 1`-4` for connections from column outlet to valve, use fingertight PEEK fittings for connecting the column outlet. For a short column: use Capillary ST 0.12 mm x 130 mm SL/M (5500-1200) For a long column: use Capillary ST 0.12 mm x 250 mm SV/M (5067-4746) 13

Setup Examples 1 1-4 column-selection Figure 3 Hydraulic flow path schematics for a 4-column selection setup 2 Two column selection with purge line and valve-bypass Figure 4 Hydraulic flow path schematics for 2-column selection setup with purge and valve bypass line 14

Valve Specifications Table 1 Type G4237A (5067-4287), 4-column selection, 800 bar Specification Liquid contacts Port size Flow passage diameters PEEK, Stainless Steel Accepts M4 male threaded fittings Stator: 0.25 mm (0.010 in) Rotor Seal: 0.30 mm (0.012 in) Port to Port Volume 0.93 µl Maximum Pressure 800 bar ph Range 0 14 Maximum Temperature 85 C Valve Parts Replacement Parts Table 2 Replacement Parts Valve Rotor Seal Stator Head Bearing Ring Stator Screws (Pack of 10) Stator Ring 4 column selector valve head, 800 bar (5067-4279) 5068-0264 5068-0263 1534-4045 5068-0089 n.a. 15

Valve Head Parts The figure below illustrates replacement parts for the valve heads, with the 12ps/13pt Selector valve as an example. The valves can vary in their appearance and do not necessarily include all of the illustrated parts. Neither, every spare part is available for each flavor of the valve. Figure 5 Valve Head Parts (example) 1 Stator screws 2 Stator head assembly 3 Stator ring screws (not available) 4 Stator ring (available for service only) 5 Rotor seal 6 Bearing ring 7 Spanner nut (available for service only) *G4237-90010* *G4237-90010* G4237-90010 Part Number: G4237-90010 Edition: 06/2017 Printed in Germany Agilent Technologies, Inc 2017 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn, Germany