Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Similar documents
EMPAC Metal enclosed capacitor bank for wind applications

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Live Tank Circuit Breakers Buyer s Guide - Section LTB family

ZX-Family Gas-insulated medium voltage switchgear

ZX2 Gas-insulated medium voltage switchgear

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Voltage limiting device HVL

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

B kv T&D GAS INSULATED SWITCHGEAR

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Voltage limiting device HVL

Surge arrester POLIM-H..SD

Product brochure. Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Product Brochure. Gas-insulated Switchgear ELK-14 The modular system for GIS, 245 kv

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Live Tank Circuit Breakers Buyer s Guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Surge arrester POLIM-H.. ND

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Independent Testing Laboratory for High Voltage Equipment

HD4. Gas insulated MV circuit-breakers kv A ka

Power Voltage Transformers for Air Insulated Substations

Air-insulated switchgear UniGear type ZS1

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

3TM Vacuum Contactors

Surge arrester POLIM-C.. HD

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

AIR CORE REACTORS. Phoenix Electric Corporation

Combined instrument transformers

Inductive voltage transformers

ZX2.2 Gas-insulated medium voltage switchgear

Outdoor vacuum breaker for railway applications - FSK II

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

OHB Outdoor sulphur Hexafluoride circuit-breaker

Surge arrester POLIM-H..N

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

B kv Gas-insulated Substations

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Inductive voltage transformers

Inductive voltage transformers

ZX-Family Gas-insulated medium voltage switchgear

CP Automatic capacitor bank

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Horizontal Circuit Switchers

Modular Standardized Electrical and Control Solutions for Fast Track Projects

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Mini contactors B6, BC6 with 3 pole

Publication No.: PSG

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Horizontal Circuit Switchers

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Inductive voltage transformers

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

PASS M0. Innovative solutions for distribution substations up to 170 kv

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Selective main circuit breakers S 750 series Technical Data

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Current transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv

Gas Insulated Metal-clad Switchgear, HMGS!

Product brochure. Gas-insulated Switchgear ELK-3 GIS for maximum performance, 420 kv

HIS Highly Integrated Switchgear up to 550 kv, 63 ka, 5000 A Type 8DQ1

Surge arresters Product overview

Gas-insulated switchgear up to 420 kv, 63 ka, 5000 A Type 8DQ1. siemens.com/energy. Answers for energy.

SWITCHGEAR DIVISION PRODUCT PROFILES

Breaker-failure protection RAICA

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Raising the bar. UHV switchgear and components

Medium Voltage Metal-Enclosed Switches

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

Short form catalogue Motor protection and control Manual motor starters

Inductive voltage transformers

Inductive voltage transformers

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Transcription:

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

SF6 circuit breaker EDT with integrated current transformer ABB is a world leader in live tank circuit breaker (LTB) technology with more than a century of experience in development, production, engineering and project handling. ABB offers a complete range of LTB from 36-1100 kv. ABB products are manufactured in factories which are continuously working on improvements to quality, health and safety, environmental concerns and social responsibility. EDT SK The EDT SK is a combined apparatus including an ED type SF6 live tank breaker, with a central compartment per pole, and an integrated current transformer. Rated voltages for this equipment are from 36-72.5 kv and rated breaking current from 25 31.5 ka. The circuit breakers are available for single or three pole operation. Each set of current transformers has two primary ratios and up to three secondary windings. Main features and advantages The EDT circuit breaker is based on the latest developments in arc research, integrating in a single apparatus, functions of interruption and measurement, and offers the following advantages: Restrike-free interruption of capacitive currents due to high inherent dielectric strength of SF6 gas and optimized contact movement. Low over-voltages when switching inductive currents due to optimum quenching at current zero. High dielectric strength even when SF6 gas is at atmospheric pressure due to wide contact gap. Low operating energy, reduced mechanical stress on breaker and low reaction forces on the foundation. High making capacity even in the case of parallel connected capacitor banks. High seismic capability due to optimized pole and structure design. Easy installation and commissioning. Each circuit breaker is pre-tested and shipped to site in the form of few easily inter-connected units. Change of primary relation in the high voltage terminals without need for accessories. Having SF6 rupture disks and optional composite insulators reduces the explosion risks. Properties Nominal voltage Rated current Rated breaking current Rated frequency Primary current Secondary current Protection Measurement Typical value 36 to 72.5 kv up to 1600 A 25-31.5 ka 50 and 60 Hz 100/200 A to 800/1600 A 1 to 5 A 10-30 VA 5P20 10-30 VA Cl 0.2s, 0.2, 0.5 2 Outdoor live tank SF6 circuit breaker

Design The circuit breaker poles include the breaking unit, the current transformers, the ceramic or composite support insulator and the pole linkage housing. The three poles of the breaker are mounted on a common support frame with the operating mechanism arranged below the same frame. The three breaker poles have a common gas system. For operations down to 30º C, the system is filled with SF6 gas at a pressure of 0.7MPa (abs at a temperature of +20 ºC). For applications where temperatures are as low as 50º C the common gas system is filled with a mixture of SF6 gas and nitrogen gas. When the SF6 and nitrogen gas mixture is used the breaking capacity is normally reduced one IEC step i.e. from 31.5 to 25kA. The operating reliability and service life of an SF6 circuit breaker is dependent on the maintenance of SF6 gas pressure and neutralization of the effects of moisture and decomposed products in the gas. This is achieved by: Well proven double O-rings of nitrile rubber for sealing purposes. Each breaking unit is provided with a desiccant, which absorbs moisture and gaseous decomposed products. Interruption capability is a function of SF6 gas density. A density monitor consisting of a temperature-independent pressure switch is provided in the circuit breaker. Temperature-dependent pressure variations of SF6 gas are compensated by hermetically sealed reference gas volume. An alarm signal is triggered when pressure drops due to loss of gas. upper terminal ceramic or silicon rubber insulator contact current transformer Operating mechanism, type FSA The circuit breaker is operated by a motor charged spring operating mechanism, which is installed in a splash-proof aluminum painted cubicle. Protection class IP-55. One FSA is used for three-pole operation. Three FSA are used when single pole operation is required. Outdoor live tank SF6 circuit breaker 3

Options Mechanical options Insulators Support structure Mechanical lock with key Extra corrosion protection Image contact Four door FSA operating mechanism SF6 gas monitoring Outdoor manometer Analogic SF6 gas monitor Electrical customization Grounding pads High voltage connections Six to twelve auxiliary contacts Multi-pole terminal contact. Surveillance of coils Minimum voltage trip coil Zero voltage capacitor trip Special applications Single pole operating driver Master-Slave Switchsync TM Withdrawable EDT EDT compact available in brown ceramic (grey on special request) or silicone rubber, with standard 25 mm/kv or long 31 mm/kv creepage distance. Silicone rubber insulators are used for improved safety, overall weight and electrical isolation. can be specifically designed to meet on-site distance requirements. to avoid unintended or unauthorized operation system for long term protection against corrosion, consisting of stainless steel pipe, with optional protective coating, and an hotdip galvanized metal structure with protective painting. measure breaker timing parameters allowing condition-based approaches for maintenance. facilitates access to the mechanism. simplifies on side maintenance records and doubles security of SF6 monitoring. monitors the quantity of gas in the breaker. for connection to earth. for both aluminum and cooper terminals. allows various different possibilities for the wiring of signals. improves mechanical and electrical protection in demanding environments. improves reliability of the circuit breaker by constant checks of the coil conditions. a security system which acts in situations of loss of electrical supply. The minimum voltage trip coil will open the circuit breaker when the supply falls below a determined voltage. opens the circuit breaker when there is no electrical supply (zero voltage). allows both single phase and three phase operation. for special circuit breaker applications, such as shunt capacitor banks or reactors, where uncontrolled closing or opening operations may lead to severe voltage and current switching transients. integrates circuit breaker, current transformer, disconnecting and earthing switch functions in a very competitive space-cost solution. includes all the features of the Withdrawable EDT plus voltage transformer, surge arrester and bus bar functions, in the best spacecost solution. Transportation and erection The EDT SK circuit breaker is transported as a complete unit filled with SF6 gas to a slight atmospheric overpressure. As the circuit-breaker is assembled and routine tested in the factory, the erection work at site is minimal and can easily be done in a day. Filling of the SF6 gas on site to specified working pressure can be facilitated by using the following pressurizing equipment: A special control valve for connection of SF6 gas bottle, and a 20 m long hose with connector. Complementary control valve for connection to nitrogen gas bottle (for mixed gas filling). Quality, safety and sustainability To ensure consistent and high product quality all components are subjected to stringent quality tests prior to manufacturing. To guarantee trouble-free functioning, comprehensive electrical and mechanical routine tests are carried out on the poles and operating mechanism after the product is fully assembled. Switchgear factory of ABB on Cordoba is certified with ISO 9001, ISO 14000, EMAS and ISO 18001 OHSAS. 4 Outdoor live tank SF6 circuit breaker

Technical data Values complying with IEC 62271-100 (50 Hz) and ANSI C37 (60Hz) EDT SK 1-1 36 52 72.5 Rated voltage IEC kv 36 52 72.5 ANSI kv 38 52 72.5 Power frequency withstand voltage - 1 min. dry IEC kv 70 95 140-1 min. wet IEC kv 70 95 140-1 min. dry ANSI kv 105 105 160-10 s. wet ANSI kv 105 105 140 Lightning impulse withstand voltage IEC kv 170 250 325 - Full wave 1.2/50 us ANSI kv 200 200 250 - Chopped wave 2 us ANSI kv 258 258 452 - Chopped wave 3 us ANSI kv 230 230 402 Creepage distance to earth (1) (2) mm 1390 1390 1995 Creepage distance across break (1) (2) mm 1995 1995 1995 Rated normal current A 1600 1600 1600 Rated breaking current (3) a 50 Hz ka 31.5 31.5 31.5 a 60 Hz ka 25 25 25 First pole to clear factor 1.5 1.5 1.5 1.5 Making current/peak (3) ka 62.5/79.0 62.5/79.0 62.5/79.0 Duration of short circuit s 1 1 1 Closing time ms 60 Opening time ms 35 Total break time ms 60 Dead time ms 300 Rated reclosing time, 60 Hz ANSI 20 Rated operating sequence IEC ANSI O-0.3s-CO-3min-CO ANSI CO-15s-CO Current transformer (4) Cover Type A Insulation Type B (SF6 gas) Cores by phase 1 3 Measure and/or protection Secondary relation 1 to 5 A Class precision Cl 0.2, 0.2S, 0.5 Protection 5P15 to 5P30 Power 10 to 30 VA Primary relation Double relation 1) Other values on request. 2) Tolerance according to IEC 233.3. 3) 100% SF6 gas. 4) Technical specification according to customer requirements. Data and illustration are not binding. We reserve the right to make changes in the course of technical development. Shipping data Type EDT SK 72.5 kv ceramic/composite insulator three pole operation include one operating mechanism EDT SK 52 kv ceramic/composite insulator three pole operation include one operating mechanism Number of cases Total volume (m 3 ) Total gross weight (kg) Total net weight (kg) 1 4.64 905/865 755/715 1 4.64 755/728 605/578 Outdoor live tank SF6 circuit breaker 5

Selection table for current transformers The EDT SK circuit breaker integrates SF6 insulated current transformers with one, two or three cores. Current transformers are designed and selected ad-hoc to satisfy on-site requirements regarding primary and secondary currents, accuracy classes and power. Current transformers are designed and tested according to IEC 60044 prior to assembly to ensure the most reliable and accurate operation. Hz Primary current Secondary current 6 Outdoor live tank SF6 circuit breaker Accuracy classes and power (S1) Accuracy classes and power (S2) Accuracy classes and power (S3) 50 100 200 5 5 5 Cl 0.5 15VA 5P20 10VA 5P20 10VA 50 100 200 5 5 5 Cl 0.2S 5VA 5P20 10VA 5P20 10VA 50 100 200 5 5 5 Cl 0.2 10VA 5P20 10VA 5P20 10VA 50 100 200 5 5 5 Cl 0.2S 10VA Cl 0.5 15VA 5P20 10VA 50 150 300 5 5 5 Cl 0.2S 15VA 5P20 15VA 5P20 15VA 50 200 400 5 5 5 Cl 0.5 15VA 5P20 15VA 5P20 15VA 50 200 400 5 5 5 Cl 0.2S 15VA 5P20 15VA 5P20 15VA 50 200 400 5 5 5 Cl 0.2S 15VA Cl 0.5 15VA 5P20 15VA 50 200 400 5 5 5 Cl 0.2S 20VA 5P20 20VA 5P20 20VA 50 200 400 5 5 5 Cl 0.2S 10VA Cl 0.5 25VA 5P20 25VA 50 300 600 5 5 5 Cl 0.2S 15VA Cl 0.5 15VA 5P20 15VA 50 400 800 5 5 5 Cl 0.5 15VA 5P20 15VA 5P20 15VA 50 400 800 5 5 5 Cl 0.2S 15VA 5P20 15VA 5P20 15VA 50 400 800 5 5 5 Cl 0.2S 15VA Cl 0.5 15VA 5P20 15VA 50 400 800 5 5 5 Cl 0.2S 15VA 5P20 20VA 5P20 20VA 50 400 800 5 5 5 Cl 0.2S 30VA 5P20 30VA 5P20 30VA 50 400 800 5 5 5 Cl 0.5 20VA 5P30 25VA 5P30 25VA 50 500 1000 1 1 1 Cl 0.2 30VA Cl 0.2 30VA 10P10 30VA 50 600 1200 5 5 5 Cl 0.2S 15VA Cl 0.5 15VA 5P20 15VA 50 625 1250 1 1 1 Cl 0.2 30VA Cl 0.2 30VA 10P10 30VA 50 700 1400 5 5 5 Cl 0.2 50VA Cl 0.2 30VA 10P10 30VA 50 750 1500 5 5 5 Cl 0.2S 15VA Cl 0.5 15VA 5P20 15VA 50 800 1600 5 5 5 Cl 0.2S 15VA Cl 0.5 15VA 5P20 15VA 60 100 200 5 5 5 Cl 0.2 10VA 5P20 10VA 5P20 10VA 60 100 200 5 5 5 Cl 0.5 15VA 5P20 10VA 5P20 10VA 60 200 400 5 5 5 Cl 0.2 30VA 5P20 30VA 5P20 30VA 60 200 400 5 5 5 Cl 0.2 15VA 5P20 15VA 5P20 15VA 60 300 600 5 5 5 Cl 0.5 30VA 5P20 30VA 5P20 30VA 60 400 800 5 5 5 Cl 0.2S 15VA 5P20 15VA 5P20 15VA 60 400 800 5 5 5 Cl 0.2 30VA 5P20 30VA 5P20 30VA 60 500 400 5 5 5 Cl 0.2S 15VA 5P20 15VA 5P20 15VA 60 600 1200 5 5 5 Cl 0.2S 15VA Cl 0.5 30VA 5P20 30VA 60 600 1200 5 5 5 Cl 0.2S 15VA 5P20 15VA 5P20 30VA 60 600 1200 5 5 5 Cl 0.2 15VA 5P20 15VA 5P20 15VA Others configurations avaible under request.

Dimensions EDT SK 1-1 72.5 kv, 3 pole operation 1050 1050 230 196 196 D=14 45 15.5 660 80 Ø354 660 15 257 257 3206 3297 12.5 18 338 15 7.5 40 18 498 (220) 400 175 1953 1293 987 200 2033 2495 Dimensions in mm. Other phase separation can be accommodated. Withdrawable option with earthing switch EDT SK 1-1 72.5 kv 805 ( STROKE) Y (1. 1050 1050 Ø14(8x) 40 18 47.5 (1. Y 179 A B 445 C 47.5 45 VIEW Y 40 45 15.5 160 4490 A (7. A EARTHING SWITCH 2970 FSA OPERATING MECHANISM CONTROL BOX 650 (8. 1873 2695 Dimensions in mm. Other phase separation and/or overall height requirements can be accommodated. 3947 Outdoor live tank SF6 circuit breaker 7

Contact us Asea Brown Boveri, S.A. Escritor Conde Zamora, s.n. 14004 Cordoba, Spain Phone +34 957 46 91 00 Fax: +34 957 46 92 42 www.abb.com/highvoltage Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2014 ABB All rights reserved 2GPC800091-101