www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

Similar documents
A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Medium Voltage Metal-Enclosed Switches

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Medium Voltage Metal-Enclosed Switches

Chapter 6 Generator-Voltage System

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Metal Clad VCBs ~ Mk1

SWITCHGEAR DIVISION PRODUCT PROFILES

POWERCON CORPORATION

Gas Insulated Metal-clad Switchgear, HMGS!

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Extensible Unit - VCE2a

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

C1000 Series Automatic Cap Bank

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Unit Substation Transformers 5 and 15 KV Class

Tradition. Technology. Innovation.

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

NEW Solutions for Underground System Growth

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

BGE STRATEGIC CUSTOMER ENGINEERING

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

SafeGear TM Motor Control Center Arc resistant metal-clad construction

7. SERVICES OVER 600 VOLTS

SECTION PANELBOARDS

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Aluminum Vertical Break Switch kv A.

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Advance 27 ANSI 27 kv switchgear

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

Switchgear Arrangement, Torque Requirements, Insulation Systems & Maintenance Intervals. Mike Schmaderer

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

University of Houston Master Construction Specifications Insert Project Name

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Ampgard The name motor applications rely on

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Pretest Module 29 High Voltage Unit 1

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

Unified requirements for systems with voltages above 1 kv up to 15 kv

Copper Vertical Break Switch kv A.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

A. Submit manufacturer's literature and technical data before starting work.

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

TYPE V CENTER BREAK SWITCH

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Controlled Power HSN High Speed DC Circuit Breakers

33KV INDOOR SWITCHGEAR

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Product Guide. enclosed NEMA STARTERS

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Service Entrance Methods

Electromagnetic Industries LLP

MAGNETIC MOTOR STARTERS

Control Transformers

Switchgear and Distribution Systems for Engineers and Technicians

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

S&C Manual PME Pad-Mounted Gear

Transformer Protection

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

Three-Phase Pole Mounted Recloser

Wheeler Ridge Junction Substation Project Description and Functional Specifications for Competitive Solicitation

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

SECTION MOTOR CONTROLLERS

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

When power interruptions happen.

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Switchgear. Low Voltage

Product guide. Enclosed NEMA starters. Answers for industry.

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

Design Standard. Purpose: Design Standard:

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

Multi-Pak Group Control

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Transcription:

PRIMARY UNIT SUBSTATIONS SECTION 2701 PRIMARY UNIT SUBSTATIONS Ratings: lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts PAGE 1 ---JUNE 1, 1959 DESIGNED AND BUILT TO MEET YOUR OWN REQUIREMENTS EXACTLY-yet costs no more Here's how to get more substation value for your dollar. 1-T-E engineers design a substation to meet your particular needs... then skillfully select from the broad line of quality 1-T-E substation components to give you the advantages of maximum economy, reliability, safety and convenience. In custom designing your substation, 1-T-E places particular emphasis on ease of installation and on meeting whatever may be your special requirements for growth and relocation. Standard components are used to save design time. Factory production and prefabrication save installal T E CIR CUIT BREAKE R C O MPANY tion cost by keeping work at the site to a minimum. 1-T-E engineers coordinate the selected equipment so that it is structurally and electrically mated. When you purchase a complete 1-T-E substation, drawings are promptly forwarded for site preparation. Manufacturing proceeds without the delays experienced when equipment from more than one manufacturer must be coordinated. Experienced engineering supervision carries through to installation. Shipping is scheduled so that all parts arrive on time to assure you of early availability for service. Printed in U.S. A. Distribution-List 16.1 www. ElectricalPartManuals. com PRIMARY UNIT SUBSTATION S DESCRIPTION NEW

www. ElectricalPartManuals. com

2701 SECTION PRIMARY UNIT SUBSTATIONS PAGE 2 JUNE l, 1959 -- NEW OUTDOOR STATION INCOMING This is a common method of terminating incoming powerlines ahead of primary unit substations. 1-T-E can supply outdoor stations of steel or aluminum in any arrangement dictated by circuit requirements. Units are designed simply and economically, but in every case with ample strength for wind, ice and line loads. Disconnecting switches in ratings 6.9 through 69 kv available from 1-T-E's broad line. OIL SWITCH AND TERMINAL CHAMBER A combination of oil switch and terminal chamber provides for transformer isolation without service interruption on the high-voltage line. The switch is keyinterlocked with the associated transformer power circuit breaker to prevent opening under load current. Oil switches are applicable as standardized equipment up to 15 kv and as nonstandardized equipment up to 69 kv. Terminal chambers for incoming cable are available air filled up to 15 kv, oil filled through 69 kv. Oil switch Terminal chamber SECTION METAL-CLAD SWITCHGEAR When incoming line voltage is 13.8 kv or less, 1-T-E metal-clad switchgear with air-magnetic circuit breakers can be used as the primary disconnect. Throatconnected to the transformer primary, it protects the transformer from fault currents besides providing a means of transformer isolation. It also permits differential relaying. Range of ratings is 150 to 1000 mva in standard current ratings. AIR INTERRUPTER SWITCH 1-T-E Type HPL-C air interrupter switches are furnished completely enclosed in metal and normally throat-connected to the transformer. The Type HPL-C switch closes into faults in complete safety for personnel. May be safely opened under full load. Available in a variety of arrangements, fused or unfused. Either current-limiting or non-current-limiting fuses are available, depending upon requirements. Ratings up to 14.4 kv, 2000 amp continuous and 95 BIL. www. ElectricalPartManuals. com,

www. ElectricalPartManuals. com

Typical 1-T-E primary unit substation transformer I-T-E supplies a full range of substation transformers manufactured in accordance with industry standards. They are available with or without provisions for tap changing under load. I-T-E transformers are built to resist the heaviest stresses. As a result, you have less risk of trouble in service, virtual freedom from transformer damage due to abnormal stresses, and greater length of service. Of all transformer manufacturers, only I-T-E assembles cores on a fiat bed prior to assembling coils. This insures better alignment of laminations in completed transformers for quieter operation and less heat generation. Tanks for liquid-filled transformers are double welded inside and out to prevent risk of leakage. Sides and cover are reinforced for extra strength. 1-T-E CIRCUIT BREAKER COMPANY Printed in U. 5. A. PRIMARY UNIT SUBSTATIONS TRA NSFORMER SECTION Transformer with load ratio control Tanking a core and coil assembly SECTION 2701 PAGE 3 JUNE I, 1959 NEW Distribution-list 16.1 www. ElectricalPartManuals. com

www. ElectricalPartManuals. com

. 2701 SECTION PAGE 4 JUNE l, 1959 NEW Better workmanship quickly identifies 1-T-E switchgear. Equipment has a better appearance in the beginning... keeps it longer. PRIMARY UNIT SUBSTATIONS 1-T -E metal-clad switchgear is available in a complete line, including walk-in and non-walk-in types. Ratings are continuous from 75 through 350 mva in the 4160 volt class and up to I 000 mva in the 13.8 kv class. Horizontal drawout circuit breakers roll out easily on permanently attached wheels. Safety shutters automatically close over bus openings when breaker is moved to test position or away from enclosure. Breakers are OUTG OING SECTION Horizontal drawout circuit breakers. "'Il One man can move breaker into or out of compartment in complete safety. Breakers cannot be moved in or out of connected position unless open. Simplified maintenance. Circuit breaker II. in 13.8 kv class illustrates pivoting arc,. chute assembly which gives easy access to contacts. Uniform magnetic flux density over entire length of arc chute speeds quenching of even high fault current arcs. fully interchangeable in same ratings. So power outage time can be kept to a minimum. This is possible because of the precise dimension control on 1-T-E breakers and enclosures during manufacture. All parts of 1-T-E switchgear are accessible for quick, easy inspection. Both front and rear doors are hinged. Essential breaker components are mounted on the circuit breaker itself for easier access. www. ElectricalPartManuals. com

www. ElectricalPartManuals. com