OBSOLETE DOCUMENT. 167D Series Switching Valves. Bulletin 71.7:167D. Introduction. Features

Similar documents
167D Series Switching Valves

type 630r relief Valve

167D Series Switching Valves

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Type MR108 Direct-Operated Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

type 122a three-way Switching Valve

T205VB Series Tank Blanketing Vacuum Breakers

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

Type 289P Pilot-Operated Relief Valve

Type T205B Balanced Tank Blanketing Regulator

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Type 310A-32A Pressure Reducing Regulator

289 Series Relief Valves

Y690A Series Pressure Reducing Regulators

OBSOLETE DOCUMENT. PRX Series Pilots for Pilot-Operated Pressure Reducing Regulators. PRX Series. Introduction. Product Description

Type 289P Pilot-Operated Relief Valve

Bulletin: Floating Ball Valve. Tartarini Floating Ball Valve. Introduction. Features and Benefits

cs200 series commercial / Industrial pressure reducing regulators

Type 289RC Exhaust Booster

67C Series Instrument Supply Regulators

Type D2 FloPro Control Valve

S203 Series Relief Monitor Regulators

FLA Series Pressure Reducing Regulator

67 Series Pressure Regulators

Type 63EG-98HM Pilot-Operated Relief Valve or Backpressure Regulator

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

133 Series Direct-Operated Regulators

Types 63EG and EGR

Type MR108 Direct-Operated Backpressure Regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

T205 Series Tank Blanketing Regulators

Design D4 Control Valve

627 Series Pressure Reducing Regulators

T205 Series Tank Blanketing Regulators

119 Series Fuel Gas Valve

Fisher D4 Control Valve Assembly

627 Series Pressure Reducing Regulators

Fisher 377 Trip Valve

Fisher 377 Trip Valve

627 Series Pressure Reducing Regulators

Types 95LD and 95HD Differential Pressure Regulators

Type 92S Pilot-Operated Steam Regulators

Y690A Series Pressure Reducing Regulators

MR98 Series Backpressure Regulators, Relief and Differential Relief Valves

CS800 Series Commercial/Industrial Pressure Reducing Regulators

Fisher D4 Control Valve Assembly

Fisher VBL Volume Booster

Type EZH Relief or Backpressure Regulator

Types 98L and 98H Backpressure Regulators and Relief Valves

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Fisher 8532 High-Performance Butterfly Valve

SLAM-SHUT VALVE. Type OSE

ES-665 Series Spring-Loaded Thief Hatch

Fisher 8532 High-Performance Butterfly Valve

161 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher A31D Double-Flange High-Performance Butterfly Valve

Fisher VBL Volume Booster

Baumann Pneumatic Pressure Controller (for Industrial and Sanitary Applications)

Fisher 657 and 667 Diaphragm Actuators

Type LR125 Pressure Reducing Liquid Regulator

Type EZL Relief Valve or Backpressure Regulator

PRX Series Pilots for Pilot-Operated Pressure Reducing Regulators

Fisher eplug complete Rotary Control Valve and Actuator Package

Fisher V250 Rotary Control Valve

Fisher 9500 Butterfly Control Valve

Fisher SS-263 Volume Booster

Fisher 656 Diaphragm Actuator

Type 1051 and 1052 Diaphragm Rotary Actuators

Type 8560 Eccentric Disk Butterfly Control Valve

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Type 1190 Low-Pressure Gas Blanketing Regulator

Fisher 685 Piston Actuator

Features. Product Bulletin 51.6:8590 August Valve D104017X012

Fisher 3024C Diaphragm Actuator

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Fisher V260 Ball Control Valve

Fisher CL600 Control-Disk Valve

Fisher 2506 and 2516 Receiver Controllers

Baumann Corrosion Resistant Control Valve

Fisherr 1051 and 1052 Diaphragm Rotary Actuators

Design D and DA Control Valves

Types P551 and P551A External Closing Spring Retrofit Kits for the Type N550/N551 ESV

Fisher 3660 and 3661 Positioners

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Accessories. Section Outline

Pressure control solutions for your industry. Aerospace & Defense

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Fisher 8590 High-Performance Butterfly Valve

Design V250 Rotary Control Valve

Type EZR Relief Valve or Backpressure Regulator

Fisher Z500 Severe Service Ball Valves

Fisher 480 Series Yokeless Piston Actuators

Fisher V500 Rotary Globe Control Valve

Fisher CV500 Rotary Globe Control Valve

Fisher 546 Electro Pneumatic Transducer

Baumann Sanitary Control Valve

Type SR8 Sanitary Backpressure Regulator

Fisher 377 Trip Valve

Transcription:

167D Series Switching Valves P1185 Type 167D Two-way Switching Valve Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are typically used to deliver constant reduced pressure of gaseous fluids to pilot-operated controllers and other pneumatic instrumentation. The Types 167D and 167DS are two-way switching valves. The Types 167DA and 167DAS are three-way switching valves. Features Compact The Types 167D and 167DA switching valves are engineered for outstanding performance in a compact, lightweight package. Easy, Accurate Adjustment With a choice of springs for optimum resolution, the switching point is set to a specific requirement by an adjusting screw atop the spring case. Patent Pending P1184 www.emersonprocess.com/regulators Bulletin 71.7:167D Type 167DA Three-way Switching Valve October 2009 Sour Gas Service Capability NACE MR0175 and MR0103 compliant construction available. Optional Stainless Steel Construction The Types 167DS and 167DAS provide high resistance to corrosion especially beneficial in offshore applications. Ease of Maintenance No special tools are required to perform maintenance, and all maintenance can be performed with the valve in the line. Rugged Construction The Types 167D and 167DA switching valves are engineered for longer service life with minimal maintenance requirements. Corrosion Resistant Fasteners Bolting and adjusting screw are double zinc-chromated for enhanced corrosion resistance. Optional stainless steel bolting and adjusting screw are also available. D103235X012

Bulletin 71.7:167D Specifications Body Size, Inlet and Outlet Connection Style Ports A and C: 1/4 or 1/2 NPT Vent and Control Pressure Connections (Port D) and Port B: 1/4 NPT Construction Materials See Table 3 Maximum Inlet Pressure (Body Rating) (1) 400 psig (27,6 bar) Set Pressure Ranges See Table 1 Maximum Diaphragm Pressure (1) 50 psi (3,4 bar) over outlet pressure setting Flow and Sizing Coefficients See Table 2 Approximate Weights Types 167D and 167DA: 1.2 pounds (0,5 kg) Types 167DS and 167DAS: 2.8 pounds (1 kg) 2 1. The pressure/temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded. 2. Product complies with the material requirements of NACE MR0175 or MR0103. Environmental limits may apply. Table 1. Set Pressure Ranges and Control Spring Data Types 167D, 167DA 167DS, 167DAS set PRESSURE RANGE, PSIG (bar) 0 to 15 (0 to 1,0) 0 to 20 (0 to 1,4) 0 to 35 (0 to 2,4) 0 to 60 (0 to 4,1) 0 to 125 (0 to 8,6) 0 to 20 (0 to 1,4) 0 to 35 (0 to 2,4) 0 to 60 (0 to 4,1) 0 to 125 (0 to 8,6) 0 to 150 (0 to 10,3) Spring Case Vent Location Aligned with inlet standard, other positions optional Temperature Capabilities (1) Nitrile (NBR) Standard Bolting: -20 to 180 F (-29 to 82 C) Stainless Steel Bolting: -40 to 180 F (-40 to 82 C) Fluorocarbon (FKM): 0 to 300 F (-18 to 149 C) Options All Types Handwheel adjusting screw NACE MR0175 or NACE MR0103 construction (2) Panel mount (includes spring case with 1/4 NPT vent, handwheel, and panel mounting nut) Closing cap (available on spring case with 1/4 NPT vent) Fluorocarbon (FKM) elastomers for high temperatures and/or corrosive chemicals Stainless steel stem and valve plug CONTROL SPRING DATA Color Material Part Number Yellow stripe White stripe Purple stripe Brown stripe Pink stripe White Purple Brown Pink Gold Inconel is a mark owned by Special Metals Corporation Table 2. Flow and Sizing Coefficients TYPES BODY SIZE PORT 167D, 167DS 167DA, 167DAS Music Wire Chrome Silicon Inconel GG00421X012 GE40282X012 GE40283X012 GE40284X012 GE40345X012 GE40320X012 GE40321X012 GE40322X012 GE40323X012 GE40324X012 Wire Diameter, Inch (mm) 0.142 (3,61) 0.145 (3,68) 0.156 (3,96) 0.170 (4,32) 0.207 (5,26) 0.148 (3,76) 0.162 (4,12) 0.177 (4,50) 0.218 (5,54) 0.234 (5,94) Free Length, Inch (mm) 1.425 (36,2) 1.425 (36,2) 1.750 (44,4) Maximum Pressure change on diaphragm for full stroke, psid (bar d) 8 (0,55) 8 (0,55) 11 (0,76) 14 (0,96) 31 (2,1) 6 (0,41) 10 (0,69) 13 (0,90) 27 (1,9) 36 (2,5) WIDE-OPEN FLOW COEFFICIENTS IEC SIZING COEFFICIENT C 1 C g C v X t 1/4 NPT 41.46 1.09 37.56 0.89 C 1/2 NPT 46.50 1.18 39.03 0.96 All sizes B 27.79 0.96 28.74 0.52 1/4 NPT 49.35 1.60 30.58 0.59 C 1/2 NPT 58.86 1.81 32.22 0.66

soft seat O-RING port a M1152 BODY TYPE 167D two-way switching valve inlet pressure outlet pressure atmospheric pressure loading pressure Figure 2. 167D Series Operational Schematics (Port D not shown) Table 3. Construction Materials part name Body and Spring Case Adjusting screw Control spring diaphragm port c VALVE STEM valve plug valve spring 167D and 167DA Aluminum (ASTM B85/Alloy 380) soft seat O-RING port a BODY M1151 Types Bulletin 71.7:167D port b Adjusting screw TYPE 167DA three-way switching valve 167DS and 167DAS CF8M/CF3M Stainless steel Spring Retainer Aluminum 316L Stainless steel Upper Spring Seat Diaphragm Plate Zinc-plated steel Chromate conversion coated Aluminum 316 Stainless steel Control Spring Zinc-plated steel and Chrome Silicon Inconel Valve Stem Valve Plug Valve Spring Diaphragm, O-Rings, and soft seat Bolting, Adjusting Screw Brass or Aluminum Brass or 316L Stainless steel Zinc-plated steel 302 Stainless steel or Inconel (NACE) Nitrile (NBR) or Fluorocarbon (FKM) 316L Stainless steel Control spring port c valve STEM valve plug valve SPRING Zinc-plated steel or 316 Stainless steel HEXNUT Zinc-plated steel or 316 Stainless steel 316 Stainless steel Handwheel Zinc-plated steel screw with resin handwheel diaphragm 3

Bulletin 71.7:167D Figure 3. Typical 167DA or 167DAS Installation (Lockup system using Type 167DA or 167DAS to close air circuit to diaphragm of main valve in case of plant air failure. Main valve will remain in position it occupied at time of supply pressure failure.) Principle of Operation Refer to Figure 2 and also refer to Figures 3 through 5 for port D location. Control pressure enters the switching valves through Port D (not shown in Figure 2) and registers under the diaphragm. Control pressure overcomes the spring force and the diaphragm and valve plug are raised, closing port C and opening port B of the Type 167DA three-way switching valve. In this condition the Type 167D construction is turned off and the Type 167DA construction provides flow from path A to B. If, either intentionally or through pneumatic failure, the control pressure drops below the spring force, the diaphragm and valve plug move downward, opening port C and closing port B of the Type 167DA three way switching valve. In this condition both constructions provide a flow path from port A to port C. The pressure change necessary to switch the valve depends on the spring used and the setting of the adjusting screw on the switching valve. 4 type 657 10C0622 supply type dvc6010 a b type 67cfr a d c b type 167DA or 167das COOLING TOWER PUMP AF8400 PRESSURE GAUGE PUMP DISCHARGE Type 167D or 167DS switching valve SET TO OPEN AT 5 PSI (0,34 bar) WHISTLE TO INSTRUMENT AIR SUPPLY 55 PSI (3,8 bar) Figure 4. Typical 167D or 167DS Installation (Warning system using Type 167D or 167DS two-way valve to activate a whistle when pump discharge pressure falls.) Installation The switching valve can be mounted in any position, providing the vent in the spring case is free from obstruction. Connect the pneumatic control line to the port marked D on the valve body. Ports A and C (and B on the Types 167DA and 167DAS valve) are connected for the desired switching valve response to loss or decrease in pneumatic pressure. Figure 5 shows typical application of the Types 167DA and 167DAS switching valve. If the control valve inlet pressure falls below a predetermined setting, the onoff controller turns off control pressure to the switching valve. This causes the switching valve to bleed the control valve diaphragm pressure to atmosphere, closing the control valve. The control valve remains closed until the inlet pressure is restored to the desired setting. Dimensions are shown in Figure 7. A c

GE37992 type 657 Figure 5. Typical Switching Valve Application Figure 6. 167D Series Vent Positions Overpressure Protection type dvc6010/ 67cfr GE31784 The 167D Series switching valves have maximum outlet pressure ratings that are lower than their maximum inlet pressure ratings. A pressure-relieving or pressurelimiting device is needed if inlet pressure can exceed the maximum outlet pressure rating. Overpressuring any portion of a switching valve or associated equipment may cause leakage, parts damage, or personal injury due to bursting of pressure-containing parts or explosion of accumulated gas. Switching valve operation within ratings does not preclude the possibility of damage from external sources or from debris in the pipeline. A switching valve should be inspected for damage periodically and after any overpressure condition. position 4 check valve 3/4 npt type 167da or 167das S d 1 2 a c b 3 vent supply position 3 asco solenoid de-energized position 1 (aligned with inlet) (standard) position 2 Bulletin 71.7:167D factory (1/4 O.d.) or customer supplied tubing (piped by customer) volume tank shipped with actuator Universal NACE Compliance Optional materials are available for applications handling sour gases. These constructions comply with the recommendations of all NACE International sour service standards. The manufacturing processes and materials used by Emerson assure that all products specified for sour gas service comply with the chemical, physical, and metallurgical requirements of NACE MR0175 and/or NACE MR0103. Customers have the responsibility to specify correct materials. Environmental limitations may apply and shall be determined by the user. 5

Bulletin 71.7:167D Figure 7. 167D Series Dimensions 6 inlet connection 1/2 npt and optional GG01159 3.69 MAX (94) 2.78 (71) 2.98 (76) 1.49 (38) 2.75 (70) 167DA Series 0.63 (16) vent side outlet outlet connection 1/2 npt and optional inlet connection 1/2 npt and optional GG02448 3.66 MAX (93) 2.35 (60) 2.98 (76) 1.49 (38) 2.75 (70) 0.63 (16) 167D Series vent side outlet outlet connection 1/2 npt and optional Inches (mm)

Ordering Guide Type (Select One) 167D (two-way, aluminum)*** 167DS (two-way, stainless steel)*** 167DA (three-way, aluminum)*** 167DAS (three-way, stainless steel)*** Body Size (Ports A and C) (Select One) 1/4 NPT 1/2 NPT Quantity (Specify) Spring Case Style (Select One) Drilled hole vent (Types 167D and 167DA standard)*** 1/4 NPT vent (Types 167DS and 167DAS standard)*** Single hole panel mount*** Adjusting Screw (Select One) Square head (Types 167D and 167DA standard)*** Square head with closing cap (Types 167DS and 167DAS standard)*** Handwheel*** Set Pressure Range (Select One) 0 to 15 psig (0 to 1,0 bar)*** 0 to 20 psig (0 to 1,4 bar)*** 0 to 35 psig (0 to 2,4 bar)*** 0 to 60 psig (0 to 4,1 bar)*** 0 to 125 psig (0 to 8,6 bar)*** 0 to 150 psig (0 to 10,3 bar) (Types 167DS and 167DAS only)*** 1. Product complies with the material requirements of NACE MR0175. Environmental limits may apply. Regulators Quick Order Guide * * * Readily Available for Shipment * * Allow Additional Time for Shipment * Special Order, Constructed from Non-Stocked Parts. Consult your local Sales Office for Availability. Availability of the product being ordered is determined by the component with the longest shipping time for the requested construction. Bulletin 71.7:167D Diaphragm, O-Rings, and Valve Plug (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)** Spring Case Vent Location (Select One) Position 1 - Aligned with inlet (standard)*** Position 2 Position 3 Position 4 NACE MR0175 Construction (Optional) (1) Yes (not available with gauge)** NACE MR0103 Construction (Optional) Yes (not available with gauge)** Replacement Parts Kit (Optional) Yes, send one replacement parts kit to match this order. Specification Worksheet Application (Please designate units): Specific Use Line Size Gas Type and Specific Gravity Gas Temperature Does the Application Require Overpressure Protection? Yes No If yes, which is preferred: Relief Valve Monitor Regulator Shutoff Device Is overpressure protection equipment selection assistance desired? Pressure (Please designate units): Maximum Inlet Pressure (P 1max ) Minimum Inlet Pressure (P 1min ) Downstream Pressure Setting(s) (P 2 ) Maximum Flow (Q max ) Performance Required: Accuracy Requirements? Need for Extremely Fast Response? Other Requirements: 7

Bulletin 71.7:167D Industrial Regulators Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75069-1872 USA Tel: 1-800-558-5853 Outside U.S. 1-972-548-3574 Asia-Pacific Shanghai, China 201206 Tel: +86 21 2892 9000 Europe Bologna, Italy 40013 Tel: +39 051 4190611 Middle East and Africa Dubai, United Arab Emirates Tel: +971 4811 8100 For further information visit www.emersonprocess.com/regulators Natural Gas Technologies The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc., a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 2009; All Rights Reserved Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas 75069-1872 USA Tel: 1-800-558-5853 Outside U.S. 1-972-548-3574 Asia-Pacific Singapore, Singapore 128461 Tel: +65 6777 8211 Europe Bologna, Italy 40013 Tel: +39 051 4190611 Gallardon, France 28320 Tel: +33 (0)2 37 33 47 00 TESCOM Emerson Process Management Tescom Corporation USA - Headquarters Elk River, Minnesota 55330-2445 USA Tel: 1-763-241-3238 Europe Selmsdorf, Germany 23923 Tel: +49 (0) 38823 31 0