For Options, Modifications and Accessories, see pages Discount Schedule A6

Similar documents
For Options, Modifications and Accessories, see pages Discount Schedule A6

Multi-Pak Group Control

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

[V] Common Control Transformer Control (See page 1-78 Note)

Bussmann series Quik-Spec Coordination Panelboard

Enclosures. See Section Typical Description

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers

3. Coils shall be of molded construction

Design Standard. Purpose: Design Standard:

Quick selector reference guide. Motor Control Center Aftermarket Buckets

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

SIGNAL WORDS QUALIFIED PERSON

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Softstarters Type PSS. Softstarters. General information

Bulletin 190-M Compact Starters. Selection Guide

CENTERLINE 2100 Motor Control Centers

Quik-Spec Electrical Gear

Self-protected Combination Starters System PKZ 2-SP

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION PANELBOARDS

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

PANELBOARDS SECTION 1

C1000 Series Automatic Cap Bank

Bussmann series Quik-Spec Power Module Switch elevator disconnect

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Bulletin 140M Motor Protectors

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

A. Submit manufacturer's literature and technical data before starting work.

Variable Frequency AC Motor Drive Units

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

NEMA Contactors & Starters (Freedom)

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

SECTION MOTOR CONTROL

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

KT4 Manual Motor Starter

Introduction. Features. Intelligent Technologies Motor Control Center Structures

Service Entrance Methods

Quik-Spec. Section Contents

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Medium Voltage Metal-Enclosed Switches

XT IEC Power Control Manual Motor Protectors

C E R T I F I C A T E O F C O M P L I A N C E

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1489-M Circuit Breakers

Bulletin 1489 Circuit Breakers. Selection Guide

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Selection Guide Motor Control Device Solutions

Selection Guide. Control Circuit and Load Protection

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Effective December 2015 Supersedes September 2013

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Ideal for use as a manual starter

Laser Service Factory-assembled Panelboards

Type VBII Visible Blade Disconnect Switches

Panelboards Circuit Breaker / Lighting and Distribution

IN2 Enclosed Switches and Circuit Breakers

Application guide. Tmax Link OEM UL 891 Switchboard Program

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

IEC Utilization Categories (Explanation)

C E R T I F I C A T E O F C O M P L I A N C E

Enclosed Full-Voltage Starters

Customer Requirements Downtown Secondary Network Service

smissline Description

WARREN COUNTY, N.Y. M/E REFERENCE

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Operation and Maintenance manual. fusible shunt trip switch

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION DISTRIBUTION AND GROUNDING

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

EPS-ECONOMY PUMP STARTER

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Cable-Operated Disconnect Switches. Accessories

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Enclosed Full-Voltage Starters

Bolted contact switches. Pringle switches

Product Guide. NEMA pump controls.

TRANSMISSION SYSTEMS

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Transcription:

Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F are line lug compartments that provide a lug connection for incoming lines (191M) to distribute power to the motor control center or for outgoing cables (191F) to feed power from the MCC to an external load. These line lug compartments are available with ratings from 00 to 000A. al mechanical or crimp lugs can be supplied with the lug compartments. Bulletin 19F and 19M Feeder and Main Fusible Disconnect Switch Units (FDS, MFDS)........... 9 Bulletin 19M and 19F are fusible disconnect switches. These switches are available with ratings from 0A to 000A. The 19F is a plug-in unit for ratings up to 00A and frame mounted for ratings 400A and above. The 19M is frame mounted (rigidly mounted and hardwired) in the structure for all ratings. The bolted pressure switch design is used for 19 units rated 00A through 000A. Bulletin 19F and 19M Feeder and Main Circuit Breaker Units (FCB, MCB)...................... 7 Bulletin 19M and 19F are circuit breaker units with trip ratings available from 1A to 000A. These units are available with thermal magnetic trips up to 400A and electronic trips 00A and above. The 19F is a plug-in unit for ratings up to A and is a frame mounted unit for ratings 400A and above. The 19M is frame mounted for all ratings. Discount Schedule A For s, Modifications and Accessories, see pages 107-1 1

Catalog Number Explanation - Bulletin 19F and 19M Fusible Disconnect Feeders and Mains 0-00A Feeders are available as Plug-in Units 400-100A Feeders and all Mains are Frame Mounted 00-000A units have Visual Blade Bolted Pressure Switches Main and Feeder Units 8 19F T - B K C - 4J - ** Bulletin Number Mounting Maximum Trip Ratings NEMA Enclosure Line Voltage Fuse, Clip Rating and Class s 8C 8E 8A 8F Maximum Trip Code Line Voltage Code Fuse, Clip Rating Code Ratings P 0/0V 19F Fusible Disconnect Code and Class B 0A Switch Feeder (FDS) A Up to 0V See Fuse Clip Sizes/ C 0A Main Fusible N 80V on page 70. 19M Disconnect Switch D 100A KN 400V 8G (MFDS) E 00A I 41V Code s F 400A B 480V See s section G 00A C Up to 00V beginning on page 107. H 800A 8B J 100A Code Mounting K 100A T [1] 8D Top L 000A Code NEMA Enclosure B [1] Bottom K NEMA 1 or 1 Z 0. Space Factor with gasket [1] A T or B is required for all 19M units and only 400A and above 19F units. J NEMA 1 Discount Schedule A For s, Modifications and Accessories, see pages 107 1 9

Main and Feeder Units Bulletin 19F Fusible Disconnect Switch Feeders (FDS) See page 1 for product description. Select disconnect switch rating based upon 1% of actual load amperes. Refer to NEC/CEC. 19FZ Plug-in unit, 0. space factor, 0A only. 19F Plug-in unit, 0A-00A. 19FT Top-mounted feeder, 400A are top-fed, connect load to bottom of switch. 19FT Top-mounted feeder, 00A-100A are reverse-fed, connect load to top of switch. 19FB Bottom-mounted feeder, 400A-100A are top-fed, connect load to bottom of switch. Refer to Appendix for horsepower ratings. Refer to Appendix for wire size conversion table. Switch Rating Fuse Clip Rating These units have horizontal operating handles and 0 Bulletin 194R fused disconnect switch. See page 9 for information on installation into series E-J sections. 0 Wired to pull-apart terminal blocks as standard. For unit without power terminal blocks, add 110 to 0 the catalog number string (N/C). Unit will then be 0 supplied with a separately mounted disconnect switch and fuse block. 0 Dual 0 [] Dual disconnects use Cutler-Hammer fusible Dual switches. Duals must have identical fuse clip types. Only 0A and 0A disconnects with 00V Class H and R fuse clips are wired to pull-apart terminal blocks. Dual Dual units require two () sets of fuses. The fuse 100/0 [] size code must correspond to the respective fuse 100/0 clip designator code. The fuse manufacturer for Dual both fuses must be the same (e.g., 19F-CAC-4J-090G). Class Cables/ Phase Load Lugs Provided Cable/Wire Size Range Wire Space Factor Catalog Number [1] A Only Class I NEMA 1 or 1 NEMA 1 w/ gasket 0 CC, J 1 #14-#8 AWG CU 0. 19FZ-BKC- 19FZ-BJC- CC, J, R, H 1 1.0 19F-BK_- 19F-BJ_- 19F-CK_- 19F-CJ_- 0 #14-#4 AWG 1 CU 1.0 19F-BK_-44 19F-BJ_-44 0/0 [] 0/0 19F-CK_-4 19F-CJ_-4 Dual 0 [] 0 19F-CK_- 19F-CJ_- J, R, H 19F-DK_-4 19F-DJ_-4 #14-1/0 AWG 1 CU #14-4 AWG 100/0 [] 100/0 1. 19F-DK_- 19F-DJ_- Larger switch must be mounted on the left side. Dual 100 [] 100 1 #14-1/0 AWG CU 19F-DK_- 19F-DJ_- 100 100 1 #8-1/0 AWG CU 19F-DK_- 19F-DJ_- 00 00 1 #-4/0 AWG CU.0 19F-EK_- 19F-EJ_- 400 400 #1/0-0 kcmil CU. [] 19F_-FK_- 19F_-FJ_- 00 00 J, R, H, L #-00 kcmil Bolted pressure contact switch. Viewing window. [4] 19F_-GK_- 19F_-GJ_- 800 on door for visual verification of disconnect blades. 800 #-0 kcmil CU/AL. [4] 19F_-HKC- 19F_-HJC- L 100 100 4 #-0 kcmil. [4] 19F_-JKC- 19F_-JJC- 87 Delivery [1] The catalog numbers listed are not complete: For 400-100 Amperes, insert T for Top mounted or B for Bottom mounted (e.g., 19FT- or 19FB-). Unless already selected, select the voltage from Fuse Clip Voltage table (e.g., 19F-BKC). Select the fuse clip designator from Fuse Clip Sizes/s table (e.g., 19F-BKC-4J). For duals, add letter suffix only numbers are already supplied in catalog number (e.g.,19f-cka-j). If power fuse will be selected, select from table on page 08 (e.g., 19F-BKC-4J-0G). Double code number for duals (e.g., 00G). For fuse rating, based on disconnect rating, see publication 100-TD00x-EN-P. If optional load lugs will be selected, select from table on page 7. Add option number to base catalog number (e.g., 19F-GKC-9R-0G-8B00). [] Not available with DSA (options 11DSA and 11DSA). [] Frame mounted unit. Must be located at top or bottom of section. [4] Frame mounted unit, section does not have vertical wireway next to this unit. Must be located at top or bottom of section. May not be mounted in section containing other frame mounted units. -II 88 Fuse Clip Voltage Fuse Clip Sizes/s and UL Listed Short Circuit Withstand Ratings for Fusible Disconnect Switch Units (19FT, 19FB, 19MT, 19MB) Fuse Clip Designator Fuse Clip Voltage Fuse Clip Voltage Code Available Short Circuit Amperes (rms symmetrical) through 00V 0A 0A 100A 00A 400A 00A 800A 100A 100A 000A 0-0 P [] J 4J J J 7J 8J 9J 100kA 40 A [] R 4R R R 7R 8R 9R 100kA 0 A [1] H 4 7 8 9 10kA 80 N [] L L [] 4L L L 7L 100kA 400 KN [] CC 4C 100kA 41 I [] Non-Fused [4] 00N 00N 00N 00N 00N 100kA [] 480 B [] 00 C [1] Not available for 100A or 000A 19M. [] These voltage codes are to be used only when ground fault protection (option 88GF) is selected on 100A-000A 19M units. [] For 00A, 100% rated, Class L fuses are the only valid option. L indicates provision for a 01A, Class L. [4] Available on mains (19MT, 19MB) only. This is 100% rated and can be supplied in NEMA 1, 1 with gasket, and 1. Not available as standard with 100kA series coordinated bus bracing, consult factory. [] Short circuit withstand is 100kA only when protected upstream with Class L fuses that are sized in accordance with particular switch (e.g., 800A upstream fuses are to be used with 800A switch or 000A upstream fuses are to be used with 000A switch). 70 For s, Modifications and Accessories, see pages 107 1 Discount Schedule A

Main and Feeder Units Bulletin 19M Fusible Disconnect Switch Mains (MFDS) See page 1 for product description. Select disconnect switch rating based upon 1% of actual load amperes. Refer to NEC/UL/cUL. Mains are suitable for use as service entrance per NEC (UL) and CEC (CSA). If application is a four-wire system, a neutral connection plate rated for 80A is available. Select on pages, 10, 117 and 14. If a Neutral connection greater then 80A is required, refer to page and page 117 or contact your local Rockwell Automation Sales Office. Mains rated 1000A and above may require ground fault protection. For 1000-100A applications that require ground fault protection, contact your local Rockwell Automation Sales Office. For 100-000A applications that require ground fault protection, see option 88GF on page 11. Non-fused mains are available in 00A through 000A. See Fuse Clip Sizes/s table on page 70. 19MT Top-mounted main, 0A-000A are top-fed. 19MB Bottom-mounted main, 0A-400A are top-fed. 19MB Bottom-mounted main, 00A-000A are reverse-fed. Top- and bottom-mounted mains are designed with adequate space to route cables to lugs. Special consideration may need to be given to the mounting of the CT s for a metering device. Addition of a pull box might be considered. Refer to Appendix for wire size conversion table. Includes line terminal guard. 89 Switch Rating Fuse Clip Line Lugs Provided Space Factor Catalog Number [1] A Only Class I NEMA 1 and 1 w/ gasket NEMA 1 19M_-BK_- 19M_-BJ_- Rating Cables/ Cable/Wire Size Wire Class Phase Range [] 0 0 1 #14-#8 AWG CU 0 0 1 #14-# AWG CU 1. [] 19M_-CK_- 19M_-CJ_- 100 100 J, R, H 1 #8-1/0 AWG CU 19M_-DK_- 19M_-DJ_- 00 00 1 #-4/0 AWG CU.0 [] 19M_-EK_- 19M_-EJ_- 400 400 1/0-0 kcmil CU. [] 19M_-FK_- 19M_-FJ_- 00 [],[] 00 J, R, H, L #-00 kcmil CU/AL 19M_-GK_- 19M_-GJ_- 800 [],[] 800 #-0 kcmil CU/AL. [4] 19M_-HKC- 19M_-HJC- 100 [],[] 100 4 #-0 kcmil CU/AL 19M_-JKC- 19M_-JJC- L 100 [],[],[7] 100 4 #-00 kcmil CU/AL.0 19M_-KK_- 19M_-KJ_- 000 [],[],[7] 000 #-00 kcmil CU/AL 0 D W [8] 19M_-LK_- 19M_-LJ_- Delivery [1] The catalog numbers listed are not complete: Insert T for Top mounted or B for Bottom mounted (e.g., 19MT- or 19MB-). Unless already selected, select the voltage code from table on page 70 (e.g., 19MT-GKC). Then select the appropriate fuse clip designator from Fuse Clip Sizes/s on page 70 (e.g., 19MT-GKC-9J). If power fuse will be selected, select from table on page 08 (e.g., 19MT-GKC-9J-9G). For fuse rating, based on disconnect rating, see publication 100-TD00x-EN-P. If optional line lugs will be selected, select from al Crimp Lugs for Bulletins 19FT, 19FB, 19MT and 19MB table below (e.g., 19MT-GKC-9J-9G-8B00). [] If optional full-rated incoming neutral bus (see page 117) is specified, the quantity and size/type of the lug(s) on neutral lug pad will be the same as the -phase lugs. When optional half-rated incoming neutral bus (see page 117) is specified and (1) or () lugs per phase are specified, (1) lug will be provided on the half-rated neutral riser. When () or (4) lugs are specified, () lugs will be provided. When () or () lugs are specified, () lugs will be provided on half-rated neutral riser. [] Frame mounted unit. Must be located at top or bottom of section. [4] Frame mounted unit, section does not have vertical wireway next to this unit. Must be located at top or bottom of section. May not be mounted in section containing other frame mounted units. [] Fusible disconnect switch is a bolted pressure switch. No vertical wireway. Not available in NEMA R or 4 for 100A and 000A. 00A through 100A units have viewing window on door for visual verification of disconnect blades. [] Units having 100% ratings are available for these fusible disconnect switches for NEMA 1 and 1 with gasket only. Non-fused switches are 100% rated and available in NEMA 1, 1 with gasket, and 1. See options on page 1 to select. For 100% rated 100A and 000A units, no top or bottom wireway is present above or below the unit and the unit must be located at either end of the motor control center lineup. [7] When used with a -phase, 4-wire power system, horizontal neutral bus and incoming neutral bus is required. [8] Frame mounted unit, section does not have vertical wireway. Horizontal bus is deeper than standard. A special bus splice kit is provided when this unit is supplied adjacent to a section with standard depth bus. -II Discount Schedule A For s, Modifications and Accessories, see pages 107 1 71

Main and Feeder Units al Crimp Lugs for Bulletins 19FT, 19FB, 19MT and 19MB 90 Switch Size of Lug Cables/ Cable/Wire Size or Phase Range Wire 19FT 19MT Number [1] 19FB 19MB 00A Mechanical Only 1 #-0 kcmil CU 81A0 400A Panduit LCC 0 kcmil CU 8B0 [],[] 1 00 kcmil CU 8A00 [],[],[4] Burndy YA-A Series 0 kcmil CU/AL 8B0 [],[] 1 00 kcmil CU/AL 8A00 [],[],[4] 00A Panduit LCC CU 8B00 [] [] Burndy YA-A Series CU/AL 8B00 [] [] 800A Panduit LCC CU 8C00 [] [] Burndy YA-A Series CU/AL 8C00 [] [] 100A Panduit LCC 4 CU 8D00 [] [] 00 kcmil Burndy YA-A Series 4 CU/AL 8D00 [] [] 100A Panduit LCC CU 8E00 [] Burndy YA-A Series CU/AL 8E00 [] 000A Panduit LCC CU 8F00 [] Burndy YA-A Series CU/AL 8F00 [] [1] If optional full-rated incoming neutral bus (see page 117) is specified, the quantity and size/type of the lug(s) on neutral lug pad will be the same as the -phase lugs. When optional half-rated incoming neutral bus (see page 117) is specified and (1) or () lugs per phase are specified, (1) lug will be provided on the half-rated neutral riser. When () or (4) lugs are specified, () lugs will be provided. When () or () lugs are specified, () lugs will be provided on half-rated neutral riser. [] For top entry of incoming cables only. [] Disconnect supplied with lug pad assembly, reference page 1 for additional lugs. [4] Requires pullbox. Select on page 8. 7 For s, Modifications and Accessories, see pages 107 1 Discount Schedule A

4 9 10 11 1 1 14 1 1 17 Factory-Installed s, Modifications, Accessories for Contactors and Starters, Metering, Mains and Feeders, Lighting and Power Panels, Transformer and Miscellaneous Units Multiple option numbers are separated by a dash and added to the base catalog number in ascending order. Overload Relay Auxiliary Contact (Eutectic Alloy) (one contact per overload relay) [1] Number -11DSA DeviceNet Starter Auxiliary (DSA) [],[] -11DSA Additional Unit Space -9 Normally Open -9A Normally Closed -1 Filters for Door Vents -1A Surge Suppressor [7] -17 [8] -17R O/L Contact on [9] Left Side of Circuit -18 Description A B A B For use with contactors and starters to provide DeviceNet inputs and outputs. (4) 10V inputs and () 10V outputs. Available for 110V-10V control only. For use with contactors and starters to provide DeviceNet inputs and outputs. (4) 4VDC inputs and () 40VAC (max), 0VDC (max) outputs. Available for 110V-10VAC or 0V-40VAC control voltage. Adds 0. space factor unit space to Bulletin 11 and 11 size 1, and units. Note: Bulletin 11 and 11, sizes 1 and, cannot be increased from 1. to.0 space factors by selecting option 1, nor can size 1 increase from 0. to 1.0 space factor by using option 1. Filters for door vents on NEMA 1 and NEMA 1 with gasket Bulletin 19, 19 and 197 units On coil, one per contactor, for starters and contactors, not available on vacuum type, selection of this option requires the selection of -17R if an option relay (89 ) is also selected. For units with interposing relays (89CB and 89CBL) and unwired control relays (89CF and 89P), may only be used if option relay (89 ) is selected. Selection of this option requires selection of option -17. Except when 89CBL or Common Control is selected. Moves overload trip contact from right (grounded) side of the control circuit to left (power input) side of control circuit. FVC FVR FVNR 10L 10L 10 107 11 11 TS1W TSW 1 1 TSR1W TSRW 1E 17E 1F 17F TSR1W TSRW 1J 17J 1K 17K Feeder/ Main 19 19 147 Delivery [1] s 9 and 9A are mutually exclusive and not available with optional overload relays (-7F _). [] Not available for dual 10L or dual 11 units. Not available for 0. space factor 10L units. Not available for 0. space factor 11 or 0. space factor 11 units with E1 Plus with ground fault/jam protection (option 7FEE_G) or E1 Plus with jam protection (option 7FEE_J). Not allowed for 0. space factor 11 units with eutectic overload relay. Mutually exclusive with 89_ relay and 87 timer options. Not available with push buttons or selector switches, except options and 1F are allowed for Bulletin 10L, 10L, 11 and 11. [] DeviceNet options 11DSA and 11DSA are mutually exclusive. Not available with 7FEE_D. Not available for 19F single or dual mounted when one or both trip code 00 is used. Mutually exclusive with E overload relays, option 7FEC_. [4] A 10/40VAC source must be provided. [] Bulletins 19F and 19M require option 98 (external N.O. auxiliary contact). Bulletins 19F and 19M require option 98 (N.O. external auxiliary contact) or 98X (N.O. internal auxiliary contact). [] Not available with dual 19F units. [7] Available for 110-40V control voltage. delivery for 110-10V control voltage. PE delivery for 0-40V control voltage. Not available for common control. [8] s 17 and 89CBL are mutually exclusive. [9] Not available with option -7FEC. [10] Except primary wiring to control transformers. On units where the control transformer is inaccessible (e.g. installed under a mounting bracket), the transformer secondary x1 will be wired to the transformer secondary fuse and the transformer secondary x will be grounded and wired to the coil on Bulletin 10 or 10 units, to the coil on the starter units when option -18 is selected, to the normally closed overload relay auxiliary contact on the starter units when option -18 is not selected. [4],[],[] [],[] Available on NEMA 1 and NEMA 1 with gasket Bulletins 19, 19 and 197 only Omit -19 Omission of control wiring [10] Control Circuit -1 One (1) control circuit fuse for separate control or line to neutral control Fuse - Two () control circuit fuses for common control PE 114 Discount Schedule A

4 9 10 11 1 1 14 1 1 17 Factory-Installed s, Modifications, Accessories for Contactors and Starters, Metering, Mains and Feeders, Lighting and Power Panels, Transformer and Miscellaneous Units Multiple option numbers are separated by a dash and added to the base catalog number in ascending order. Auxiliary Contacts [] -90-91 Number -98 [4] Description NORMALLY OPEN One (1) N.O. auxiliary contact mounted on each contactor or 1- starter NORMALLY CLOSED One (1) N.C. auxiliary contact mounted on each contactor or 1- starter NORMALLY OPEN One (1) N.O. auxiliary contact (operates with movement of external handle only) NORMALLY OPEN -98X [] One (1) N.O. auxiliary contact mounted internally in circuit breaker NORMALLY CLOSED -99 [4] One (1) N.C. auxiliary contact (operates with movement of external handle only) NORMALLY CLOSED -99X [] One (1) N.C. auxiliary contact mounted internally in circuit breaker NEMA Size Misc. Units FVC [1] FVR FVNR [1] TS1W TSW [1] For vacuum contactor starters only option -91 or -900111 is allowed. [] Multiple auxiliary contacts must be group coded by adding the second and third digit of the special feature number to the base digit 9 (e.g., 90-91-98X-99, when group coded, reads 9018X9). [] B auxiliary contacts are wired to terminal blocks. If the number of auxiliary contact wiring points required exceeds the number of terminals available in the unit, remaining auxiliary contacts will be unwired. Refer to wiring diagram. [4] The maximum number of auxiliary contacts that can be supplied is two (), in any combination. Contacts actuate with movement of unit handle to ON or OFF position only. Contacts are not designed to actuate as the result of a circuit breaker trip. For such applications, auxiliary contacts mounted internally (98X or 99X) must be selected. Auxiliary contacts are supplied unwired. Not available on dual 19F units or 100A and 000A 19M units. [] For 100A and 000A 19M, the maximum number of auxiliary contacts is four (4). The following contact arrangements are allowed. -98, -99, or -989 two contacts, (1) N.O/N.C. Form-C contacts -988, -999 four contacts, two (1) N.O/N.C. Form-C contacts The auxiliary contacts are mounted external to the switch and are actuated by the movement of the operating handle. Auxiliary contacts are supplied unwired. [] The maximum number of auxiliary contacts that can be supplied internally is () N.O. and () N.C. With a shunt trip, the maximum is (1) N.O. and (1) N.C.. Not available for 19F single or dual mounted when one or both trip codes are 00. Maximum Number of Additional Auxiliary Contacts Per Starter/Contactor 14 Bulletin Number [1] NEMA Size 1- Size - Size 10L, 10L [] 11/11 [] 4 10L/11 Dual 10/107 1/1 4 4 10L/10L/11/11 0.SF 1/17 4 100D 100M 10L 10L 10 107 11 11 1 1 1 TSR1W TSRW FDS CB Xfmr Delivery A B [] A B [] 1- [] A or B 1- A or B 1- [] A or B 1- A or B [1] Units selected with OFF pilot light will use one of these contacts. Bulletins 1 and 17 will use two of these contacts. [] When Bulletin 9 timers are selected on 0-00A contactors or size 1- starters, auxiliary mounting positions (P and P4) are used, limiting the maximum number of starter auxiliaries to two (). When 89CB, 89CBL, 89CF, 89P, 700TC_, 11DSA or 11DSA with NEMA B wiring is present with transformer control in 1.0 space factor units, the number of starter auxiliary contacts is limited to four (4). When 89CBL is present with separate control and control circuit fuse (1) in 1.0 space factor units, the number of starter auxiliary contacts is limited to four (4) for units with 7FEC. In E overloads, the number of starter auxiliary contacts is limited to five (). For size units with 7FEEE_ or 7FEE_D, E1 Plus Overload, the number of auxiliary contacts is limited to five () 1 17 19F 19M 19F 19M 19 197 10 Discount Schedule A