800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Similar documents
Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

CP900EPFCLCD User s Manual K

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

USER MANUAL. Uninterruptible power supply MODEL: 53965,

Limousin II User Manual

Uninterruptible Power Supply

PR1000ELCD / PR1500ELCD User s Manual

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Uninterruptible Power System

661-SK [1]I:\USV_TEAM\USV_MANUAL\Roline\LineSecureII\661-SK [1].d oc U P S. Uninterruptible Power System

Uninterruptible Power System

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

MM-AVR UPS Series User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Installation and Operation Manual Back-UPS BR800/1100CI-IN

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Uninterruptible Power System

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Liebert PSA VA. Installer/User Guide

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Installation and Operation Manual Back-UPS BR1000-CH

1. INTRODUCTION. Features:

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

POWERWARE User s Guide VA.

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

3000VA 120/208/230VAC

Eclipse Plus VA UPS and Surge Suppressor User s Manual

Informer Compact Series

02/15/01. Powerware User s Guide VA.

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

Back-UPS CS Back-UPS CS 350

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

User s Manual Lineage LI3000 UPS K

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

BULL POWER Line Conditioner Regulating Power Bar

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Liebert PowerSure PSI UPS

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

General Precautions. Personnel Precautions

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

User s Manual Legend SB825 UPS K

U n i n t e r r u p t i b l e P o w e r S y s t e m

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Sola 3000 Guide Specifications

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Liebert PowerSure PSI

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

400 Watt Backup Power System Owner s Manual

UTILITY INPUT MAINS OUTLET

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

FALCON ELECTRIC, INC.

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Foreword

Powerware Vdc Extended Battery Cabinet User s Guide.

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

ALLIANCE SERIES OWNER'S MANUAL

User s Manual for: UP625 UPS UP825 UPS. ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:

CERTIFIED CATEGORY III-3 PROTECTION

Illuminator Series CR NEMA 3R

Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

Up to 98% efficient under full load Similar runtimes to the previous 3u model

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

USER MANUAL. Line Interactive UPS. Uninterruptible Power System

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

POWERSTAR INC. Operations / Maintenance Manual Model: PS VA Tower UPS

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Transcription:

U P S Uninterruptible Power System Line-Interactive Network UPS 800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions should be followed during installation and maintenance of the UPS and batteries. WARNING: Intend for installation in a controlled environment. Servicing of batteries should be performed or supervised by personnel knowledge of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number and type. CAUTION: Do not dispose of batteries in a fire, the battery may explode. CAUTION: Do not open or mutilate the battery, released electrolyte is harmful to the skin and eyes. It may be toxic. CAUTION: A battery can present a risk of electric shock and high short circuit current. The following precaution should be observed when working on batteries A. Remove watches, rings or other metal objects. B. Use tools with insulated handles. C. Wear rubber gloves and boots. D. Do not lay tools or metal parts on top of batteries. E. Disconnect charging source prior to connecting or disconnecting battery terminals. 1

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS..... 1 TABLE OF CONTENTS 2 INTRODUCTION..3 1. PRESENTATION........ 4 2. INSTALLATION... 6 3. OPERATION... 8 4. SOFTWARE AND COMPUTER INTERFACE.. 9 APPENDIX A. TROUBLESHOOTING 10 APPENDIX B. SPECIFICATIONS. 11 2

INTRODUCTION Please read and save this manual! Thank you for selecting this uninterruptible power system (UPS). It provides you with a perfect protection for connected equipment. The manual is a guide to install and use the UPS. It includes important safety instructions for operation and correct installation of the UPS. If you should have any problems with the UPS, please refer to this manual before calling customer service. Please save or recycle the packaging materials! The UPS s shipping materials are designed with great care to provide protection within delivery. These materials are invaluable if you ever have to return the UPS for service. Damage happened during transit is not covered under the warranty. Intelligent microprocessor control The UPS is a microprocessor-controlled unit. This means that it operates with the newest technology, high performance and powerful function. The UPS is an intelligent protector and provides pure, reliable AC power to the critical loads - protecting them from utility power blackout, swells, sags, surges and interference. Furthermore, in order to save the battery energy, UPS can automatically turn it off under backup mode if none of the connected loads is operating. Advanced battery management The visual and audible indications of the UPS present the battery s status. Self-test function let UPS detect a weak battery before it is put into service. The UPS normally perform a self-test at power up condition. 3

1. PRESENTATION 4 800VA~1500VA(220V) 2200VA(110V) 1.21 1.22 1.23 1.27 1.28 2200VA(220V)/3000VA(220V) 3000VA(110V) 800VA~1500VA(110V) FRONT & REAR PANELS 1.11 1.12 1.13 1.14 1.15 1.16 1.22 1.21 1.26 1.25 1.29 1.28 1.24 1.25 (1500VA N/A) 1.26 1.29 1.23 1.27 1.24 1.22 1.29 1.28 1.21 1.26 1.23 1.27 1.21 1.26 1.23 1.27 1.21 1.26 1.23 1.27 1.22 1.29 1.28 1.24 1.22 1.29 1.28

1.11"REPLACE BATTERY" indicator (RED LED) The LED illuminates when the UPS's battery is no longer useful and must be replaced. 1.12 "BUCK AVR (VOLTAGE REDUCTION)" indicator (YELLOW LED) The LED illuminates when the UPS is correcting a high utility voltage condition. The loads receive normal power. 1.13 "BACK UP" indicator (YELLOW LED) The LED illuminates when the UPS is supplying battery power to the loads. 1.14 "BOOST AVR (VOLTAGE BOOST)" indicator (YELLOW LED) The LED illuminates when the UPS is correcting a low utility voltage condition. The loads receive normal power. 1.15 "LINE NORMAL" indicator (GREEN LED) 1.16 "ON/OFF/TEST/SILENCE" button Press the button more than 2 seconds to turn the UPS on or off, press the button less than 1 second to activate the UPS's self-testing or silence the back up alarm. 1.21 MAIN SWITCH 1.22 REMOTE PORT (COMPUTER INTERFACE) Provide both RS-232 and relay signal to support NOVELL, UNIX, DOS, WINDOWS and other operating systems. 1.23 TEL./MODEM port Telecom transfer ports provide users to extend the applications. Caution: To reduce the risk of fire, use only No. 26AWG or larger telecommunication line cord. 1.24 SITE WIRING FAULT INDICATORS (RED LED) It comes on when the UPS is connected to an improperly wired AC power outlet. Note: This device is available on 110 Vac model only. 1.25 BYPASS OUTPUT POWER RECEPTACLES 1.26 EXTERNAL BATTERY PACK CONNECTOR (optional) Caution: Use only factory supplied or authorized connecting cable for external battery! 1.27 UPS OUTPUT RECEPTACLES 1.28 AC INPUT POWER RECEPTACLE 1.29 INPUT CIRCUIT BREAKER It trips when the connected loads exceed the protected receptacle's capacity, The center plungers of the circuit breakers extend when tripped. 5

2. INSTALLATION Inspect the UPS upon receipt. The packaging is recyclable; keep it for reuse or disposed of properly. 2.1 Recharge the battery UPS may be used by anyone immediately upon receipt. The battery is fully charged before shipped from the factory. However, user is recommended to recharge the battery at least four hours before using UPS. Energy loss may occur during shipping or long duration storage. To recharge the battery, simply let UPS be plugged into an AC outlet and switch it on. 2.2 Connect the loads Plug your primary equipment (e.g. computer, monitor and critical data storage device, etc.) to the Battery Power-Supplied outlets. Plug your peripheral equipment (e.g. printer, scanner, fax, or audio device) to the Full-time Surge Protection outlets. Do not plug laser printer to the UPS output outlets, as its power demand is much higher than typical peripherals and may cause the circuit breaker to trip. It is suggested to connect the similar heavy loads (like laser printer) to the bypass outlets. 2.3 Connect the telephone If you wish to extend the length of wire of, connect the telephone cable from the wall outlet to the IN jack. Connect the telephone cable (provided) from the OUT jack to the fax or modem. 2.4 Connect to the utility power Plug UPS to a 2-pole, 3-wire grounding receptacle. Make sure the branch is protected and does not service equipment requiring heavy electricity (e.g. refrigerator, air conditioner, copier, etc.). 2.5 UPS self-test UPS will conduct a self-test once switched on it each time. Do not add or take off any equipment while UPS conducts self-test; await it until the Power indicator lights up. Besides this, switch on your equipment after switch on UPS. 2.6 Battery auto-charging Once the power cord is connected, the battery of UPS will be automatically charged by itself. 2.7 Auto restart feature UPS is equipped with Auto Restart feature. It will activate when the battery level becomes too low to sustain its operation and the utility is not present. UPS will switch itself to waiting mode, waiting for utility switch itself on and recharge its battery. If the user is away during a utility failure, UPS will manage to return to normal function and recharge its battery when utility power returns. 6

2.8 Overload protection If an overload situation is detected during self-test, UPS audible alarm will activate, emit a long beep and automatically shut down the system. Unplug at least one piece of equipment from the Battery Supplied Outlets. Switch off UPS, wait 5 seconds and check to make sure the circuit breaker is set then switch on, again. User is allowable to change the fuse under overload condition. 2.9 Optimal battery status To maintain the optimal status of battery, let UPS be always plugged in. 2.10 Self-protection feature UPS is equipped with self-protection feature preventing people from playing with the unit to subsequently damaging the unit. It is programmed so that once switched off, the user must wait 5 seconds before switching UPS on again. 2.11 Storage To store UPS, cover it and store it with the battery fully charged. During extended storage, recharge the battery every three months to ensure battery life. 2.12 Power failure When the event of power failure occurs after turning on UPS, and prior to the self-test sequence, UPS will automatically shut down and not restart until utility power is restored. This is necessary to check the quality of power that is delivered to your connected equipment. 7

3. OPERATION 3.1 Simple test It is recommended that the user perform a simulation test when using UPS for the first time or when adding an additional piece of equipment. Conduct a simulation-test: first, switch on UPS and wait for the power indicator to light up, then simply unplug UPS to simulate the event of utility failure. 3.2 Check the power requirement of your equipment 3.2.1. Make sure the total power of your equipment does not exceed rating capacity. 3.2.2. Also make sure the equipment you plugged into the Battery Power-Supplied outlets does not require total power exceeding the capacity of the UPS. Otherwise, overload may occur and cause the circuit breaker to trip. If the power requirement of your equipment differs from VA, convert the requirement power into VA by doing the calculations below: 3.2.3. If the power requirement of your equipment is listed other than VA, convert the requirement into VA by doing the calculations below. Watt (W) X 1.67 = VA, or Amps(A) X 120= VA (For 100-120V model) Watt (W) X 1.67 = VA, or Amps(A) X 230= VA (For 220-240 model) 3.3 Limited rating power of UPS When utility failure occurs, the UPS output outlets will supply power to your equipment from its battery and the alarm will beep every 2 seconds. Be sure that your equipment is running under the limited rating power. To restore the utility by plugging UPS back in to the existing power source. Repeat the test a few times to make sure UPS works properly and to find out the expected runtime. 8

4. SOFTWARE AND COMPUTER INTERFACE 4.1 Power Monitoring Software The UPSMON series software (or other power monitoring software) is applied standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure. Moreover, UPSMON displays all the diagnostic symptoms on monitor, such as Voltage, Frequency, Battery level and so on. The software is available for Windows 95/98/ME, Windows NT/2000/XP, Novell Netware, Linux and others. Call your dealer for more information on computer OS compatible solutions. 4.2 Interface Kits A series of interface kits is available for operation systems that provide UPS monitoring. Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating system recognize. The interface cable at UPS side must be connected to REMOTE PORT, at computer side can be either COM 1 or COM 2. The other installation instructions and powerful features please refer to READ.ME file. CAUTION: Use only factory supplied or authorized UPS monitoring cable! 4.3 The characteristics of computer interface port The computer interface port has the following characteristics: The communication port on the back of the UPS may be connected to host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UPS in some cases. Its major functions normally include some or all of the following: To broadcast a warning when power fails. To close any open file before the battery is exhausted. To turn-off the UPS. Some computers are equipped with a special connector to link with the communication port. In addition, special plug-in cord may be needed. Some computers may need special UPS monitoring software. Contact your dealer for the details on the various interface Kits. 9

APPENDIX A TROUBLESHOOTING UPS has a self-protect feature that prevents the UPS from being damaged as a result of overheating. If the temperature is higher than 55 C, wait for a while and let the UPS become cool. Problems Possible Cause Solution Full-time Surge Protection outlets stop providing power to the equipment Circuit breaker button popped up as a result of overload. Unplug at least one piece of equipment from the Full-time Surge Protection outlets. Switch off UPS, wait 5 seconds, reset the circuit breaker (press down breaker button), then switch on UPS. UPS doesn t perform to its expected Battery undercharged or depleted due to frequent Recharge the battery by leaving the UPS plugged in and switched on. runtime. power outages. The power required by your equipment slightly exceeds the capacity of the UPS. Unplug at least one piece of equipment from the UPS outlets. UPS cannot be turned on. The battery is slightly worn-out. Special UPS is designed to prevent damage from flipping. The battery is worn-out. Mechanical problem. Consider replacing the battery. Switch UPS off, wait for 5 seconds, then switch UPS on. Replace the battery by following the instructions in this manual. Contact your sales representative. 10

APPENDIX B SPECIFICATIONS MODEL 800VA 1000VA 1200VA 1500VA INPUT Capacity (On Battery) 800VA /480W 1000VA /600W 1200VA /720W 1500VA /900W (Spike protection) 500VA 500VA 500VA 500VA for 220-240V only. Voltage +/-25% at line input Frequency 50 or 60 Hz +/-10% (auto sensing) OUTPUT Voltage (on battery) Simulated sine wave at 100V/115V/230V +/- 5% Frequency (on 50 or 60 Hz +/- 0.5% PROTECTION And FILTERING battery) Voltage Regulation (AVR) Transfer Time Spike Protection EMI/RFI filter Overload Protection Unit Input 10Base-T Cable Port Short Circuit AVR automatically increase output voltage 15% above input voltage if 9% to 25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal 2/4 milliseconds, including detection time 320 Joules, 2ms 10Db at 0.15MHz, 50Db at 30MHz UPS automatic shutdown if overload exceeds 110% of nominal at 60 seconds and 130% at 3 seconds Circuit Circuit Circuit Circuit Breaker Breaker Breaker Breaker For overload & Short circuit protection Network (UTP,RJ-45) compatible jacks UPS output cut off immediately or input fuse protection Sealed, Maintenance-free lead acid 4 hours (to 90% of full capacity) BATTERY Type Typical Recharge Time Protection Automatic self-test & discharge protection, Replace battery indicator Back-up Time 3 180 min (depending on computer load) PHYSICAL Weight Kg (lbs) 13.3 15.0 15.5 15.8 (29.3) (33.0) (34.1) (34.8) Dimension (mm) 130*382*201 W*D*H (5.1 *15 *7.9 ) ALARM Battery Back-up Slow beeping sound (about 0.47Hz) Battery Low Rapid beeping sound (about 1.824Hz) Overload Continue beeping sound INTERFACE Dry Contact ( DB9 ) YES YES YES YES Interface RS-232C Interface YES YES YES YES ENVIRONMENT Ambient Operation 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg C Audible Noise < 40dBA (1 meter from surface) Storage Condition 15000 meter max. 11

APPENDIX B SPECIFICATIONS MODEL 2200VA/2200VA 3000VA/3000VA INPUT Capacity (On Battery) 2200VA/1320W 3000VA/1800W Voltage +/-25% at line input Frequency 50 or 60 Hz +/-10% (auto sensing) OUTPUT Voltage (on battery) Simulated sine wave at 100V/115V/230V +/- 5% Frequency 50 or 60 Hz +/- 0.5% (on battery) Voltage Regulation (AVR) AVR automatically increase output voltage 15% above input voltage if 9% to 25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal PROTECTION And FILTERING BATTERY PHYSICAL ALARM Transfer Time Spike Protection EMI/RFI filter Overload Protection 2/4 milliseconds, including detection time 320 Joules, 2ms 10Db at 0.15MHz,50dB at 30MHz UPS automatic shutdown if overload exceeds 110% of nominal at 60 seconds and 130% at 3 seconds Unit Input Circuit Breaker Circuit Breaker For overload & Short circuit protection 10Base-T Cable Port Network(UTP,RJ-45) compatible jacks Short Circuit UPS output cut off immediately or input fuse protection Type Sealed, Maintenance-free lead acid Typical Recharge 6 hours (to 90% of full capacity) Time Protection Automatic self-test & discharge protection, Replace battery indicator Back-up Time 3 180 min (depending on computer load) Weight Kg (lbs) 26.2 29.8 (57.6) (65.6) Dimension (mm) 170*450*225 W*D*H (6.7 *17.7 *8.9 ) Battery Back-up Slow beeping sound (about 0.47Hz) Battery Low Rapid beeping sound (about 1.824Hz) Overload Continue beeping sound INTERFACE Dry Contact ( DB9 ) YES YES Interface RS-232C Interface YES YES ENVIRONMENT Ambient Operation 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg C Audible Noise < 40dBA (1 meter from surface) Storage Condition 15000 meter max. 2002.Oct.15 Version 2.4 All right Reserved. All trademarks are property of their respective owners. Specifications subject to change without notice. 12 661-KN80-005