Technical Documentation

Similar documents
Technical Documentation

TRANSNORM LOW VOLTAGE MOTORS IC 411 TN LV 1 4E5

SINGLE PHASE TEFC CAGE MOTORS

Technical Documentation

COMBROIND001_= THREE PHASE SQUIRREL CAGE INDUCTION MOTORS. IE1 motors MAA - BAA Series IE2 motors MAQ - BAQ Series

ELECTRIC MOTORS. Selection. Starting torque and nominal torque

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

champion series motors

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

: B3; B5; B14; B34; B35; V1

1 THREE-PHASE CAGE INDUCTION MOTORS

Low Voltage 3-Phase Induction Motors. Range 0.18kW to 670kW

New Generation 1LE1/1PC1

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2.

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

Industrial Performance Motors. New Aluminum and Cast Iron Motors. Flexibility

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Company name: GSI Created by: SLK Phone: (65) Date: 13/03/2017 Client: Client Number: Contact:

Series E4F E5F

LSES high efficiency three-phase asynchronous motors. General information

Business Units. Vision

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

Aluminium Frame Motors Improved Efficiency EFF2

PLS Open Drip Proof three-phase asynchronous motors. General information

This catalogue also includes cooling medium pumps of the types DKP and EKP.

Low Voltage Induction Motors

1LG0 Low-voltage Motors

HIGH EFFICIENCY INDUCTION MOTORS COMBROHEF001_=

Three-phase roller table motors with squirrel-cage rotor for the application at the frequency converters Series A21O, A20O, ARB, ARC.

KAT.NMST ENG NORM ELECTRIC MOTORS THREE PHASES SQUIRREL CAGE TEFC NMST

Technical Documentation

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

M3000 Steel Motors. ABB LV Motors M3000 Range

How do you take the first step towards an energy efficient future?

High efficiency induction motors

LSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

General Purpose Energy Efficient Induction Motors series 2SIE

THREE-PHASE ASYNCHRONOUS MOTORS EFFICIENCY CLASS ACCORDING IEC

IEC Low Voltage Induction Motors 400 V 50 Hz. Motors for all applications

Ordering information. When placing an order, specify motor type, size and product code according to the following example.

General Specifications. Cooling Method 3M series are IC 411 Standard. IC 416, IC 418 can be provided Upon request

Three-phase asynchronous motors for low voltage with squirrel-cage rotor. with EU efficiency classification

ELECTRIC MOTORS 3SIE IE3

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

IE2 Three Phase Induction Motors AN Series Catalogue

Process performance IE3 aluminum motors, 50/60 Hz The product range for global customers

Low-voltage motors up to 315kW. 1LG0 Low-voltage Motors. Answers for industry.

STANDARD VERSION OF HIGH VOLTAGE MOTORS

HAIE2 -Efficiency and reliability for industry

THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE

High Efficiency Induction Motors IE2. MarelliMotori MAQ - BAQ SERIES FRAME SIZES ASI.CT GB

Explosion and flame-proof cast iron electric motors

Standardmotoren Standard motors

Energy Saving Three Phase Motors

Open continuous current (DC) motors MS 1 - MS 2. General information

Single Phase AC Induction Electric Motors

ABB Oy MV Induction Machines

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

LSES high efficiency three-phase asynchronous motors General information

Built-in motors. Contents. Product description 7/2 Overview of technical data 7/3

General Purpose Cast Iron Motors

IEC Low Voltage Induction Motors 400 V 50 Hz. Motors for all applications

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

M3000 Motors for Hazardous Areas. Low Voltage Non-sparking Motors Ex na, EEx na

ELK PRODUCT CATALOGUE. elkmotor.com.tr

Variable speed asynchronous motors with FCPL brake LSMV FCPL. General information

Energy-efficient Cast Iron Three Phase Induction Motors 50 Hz

PRICE LIST & BASIC DATA

A B C D, E, F M2BA 112 MB 3GBA ADB, 122, 451, etc

Motors. IE changeover. IEC Squirrel-Cage Motors. Frame sizes 63 to 450 Power range 0.09 to 1250 kw Price List D 81.

Asynchronous generators

BFG range BFGC range BFN range

Metric Efficient Line Cast-iron IEC Motors

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

Technical Documentation

COMSELHYD001_= 01/2018 HYDROPOWER. Selection guide

AC MOTORS. Bangalore, India

Permanent-magnet synchronous motors

Product Catalogue. General Purpose 3-phase Induction Motors. Energy Efficient Motors series 2SIE

EMM16154-AP M3AA 160MLB 4 B3 15KW

AC MOTORS. Bangalore, India

ETM motors Data Book 50Hz - 60Hz

General Purpose Energy Efficient Induction Motors series 2SIE

MG Model C & D 3 phase kw

EMM16154-PP M3BP 160 MLB 4P B3 15kW

MVM06184C-AP (3GAA CSE+332)

MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

EFF2 Three-Phase TEFC Induction Motors

Catalog. Low voltage General performance IE2 high efficiency motors according to EU MEPS

BFG range BFGC range BFN range

DC motors. G-motion. CTi Automation - Phone: Fax: Web:

Low voltage asynchronous motors IEC motors with squirrel-cage rotor

ARAGON MOTO R S. Three Phase Induction Motors

Three-phase motors for marine use

Department/Author Customer name Customer ref. Item name

Transcription:

Technical Documentation LOW VOLTAGE THREE PHASE TEFC CAGE MOTORS IE315EN

Mission, Vision, Targets Our electric motors and generators are optimized in accordance with our client's technical and economical requests. Our clients will receive from us, within a very short notice, most advanced and high quality technical solutions of electric motors, generators, electric drives and complete technical solutions of small and middle sized hydroelectric power plants, along with economically most favourable conditions. We are constantly moving your ideas. We are not just manufacturing motors and generators, we turn ambitious concepts of our clients into advanced, innovative and reliable products, which are unique and future oriented. Our reliability, creativity and flexibility will assist our clients in achieving their goals. Keeping track with newest technological and technical solutions, our products are being constantly developped and therefore we are improving all our activities aimed to fulfil our client's requests. Our view of the future is oriented towards development of high power and big sized electric motors, hydrogenerators for small and middle sized hydroelectric power plants, as well as electric motors designed for extreme working conditions and most complex technical requirements.

Index 1 Main characteristics................................................. Electrical data Series 3.ZKE p=..............................................4 Series 3.ZKE p=4..............................................5 Series 3.ZKE p=6..............................................6 Series 3.ZKE p=8..............................................7 Motor dimensions 3.ZKE 00-3.ZKE 315; IM B3 - IM 1001..................................8 3.ZKE 00-3.ZKE 315; IM B5, V1 - IM 3001, 3011.............................9 3.ZKIE 315; IM B3 - IM 1001........................................ 10 3.ZKIE 315; IM B35 - IM 001....................................... 11 3.ZKIE 315; IM V1 - IM 3011........................................ 1 3.ZKIE 355; IM B3 - IM 1001........................................ 13 3.ZKIE 355; IM B35 - IM 001....................................... 14 3.ZKIE 355; IM V1 - IM 3011........................................ 15 ATB SEVER reserves the right to modify the design, technical specifications and dimensions of the products shown in this catalogue.

Main characteristics Changing the nomenclature of the IEC motor efficiency level New labelling and definition methods of IEC motor efficiency level according to IEC 60034-30:008 and IEC 60034--1:007 Definition of efficiency classes has been done according to different standards. For the purposes of international harmonization, a new standard has been created IEC 60034-30:008 (Rotation electric machines Part 30: Efficiency level class of one speed, three-phase asynchronous motors with a cage rotor (marking IE)). According to this standard, motors have been defined into new efficiency level classes. This standard has been valid since October 008. Since then the new nomenclature has been put into practice. New method of loss measurement according to IEC 60034--1:007 The efficiency level according to IEC 60034-30:008 is based on determining motor losses by using the standard IEC 60034-- 1:007, which has been valid since November 007 and serves as a substitute for the standard IEC 60034-:1996. With this new measuring technique additional losses are not determined as a percentage (0.5%), but are determined through the process of measuring (by using the standard IEC 60034--1:007). According to the new standard, the nomenclature of the efficiency level is changed from EFF1 to IE and from EFF to IE1. High efficiency Low efficiency New efficiency classes IE High Efficiency IE1 Standard Efficiency Determining loss according to the old and new standard: Before: P L =0,5% P Now: P LL=individual measuring (PL - additional losses dependent on the work load) New standard class of the motor efficiency level 100 % 90 IE1 to IE3 efficiencies 4-pole 50 Hz IE3 IE IE1 A new signification method is applied to new classes of efficiency levels: - IE1 standard efficiency - IE high efficiency - IE3 premium efficiency L Efficiency 80 70 Classification acc. to CEMEP 1.5 3.5 18.5 45 110 50 375 kw Power (IE marking International efficiency) L 1 3 4 5 6 7 Example of rating plates 3~Mot. C.l.F 13456009-1/10 3.ZKE 5 M-6 IMB3 IP55 D/Y 400/690 V 30 kw 50 Hz 55/3 A cosϕ 0,85 985 min IE3-93,1(100%) - 93,1(75%) - 90,6(50%) S1 460 V 30 kw 60 Hz 46 A cosϕ 0,87 118 min IE3-94,1(100%) - 94,0(75%) - 91,(50%) Made in Serbia ID# 134567 340 kg EN 60034 IE3-1 -1 50 Hz data 60 Hz data 8 1. Rated voltage at 50 Hz. Rated current at 50 Hz 3. IE efficiency class and nominal efficiency at 50 Hz 4. Rated voltage at 60 Hz 5. Rated current at 60 Hz 6. IE efficiency class and nominal efficiency at 60 Hz 7. Efficiency class logo 8. Country of origin

Main characteristics 3 committee of Manufacturers of Electrical Machines and Power Electronics (CEMEP) Number of poles, 4, 4, 6 Power range Efficiency degree Voltage 400 V, 50 Hz < 1000 V, 50/60 Hz IP5X Brake motor No Arrangement Motor reductors No Yes Ex-motors No Yes (provided that explosion prevention All Validity Voluntary arrangement, will be substituted after the implementation of the EuP directive into national laws and norms Standard IEC 60034-30 has been valid since October 008. EuP directive needs to be implemented into national laws and norms Motor power level class level Electric energy consumption per year Electric energy savings per year kw kwh kwh IE 93,5 119646 55 144 IE3 94,5 11840

4 Electrical data Voltage: 400 V, 50 Hz, F/B, IP55 Series 3.ZKE Type Output Pn Full load R.P.M. IE Efficiency ηn Power factor cosφn Full load Current In Rated torque Tn Moment of inertia J kw min -1 100%Pn 75%Pn 50%Pn A Nm kgm kg Weight 3000 min -1 3.ZKE 00 La- 30 960 IE3 93,3 93, 9, 0,87 53 97 0,173 05 3.ZKE 00 Lb- 37 965 IE3 93,7 93,7 9,8 0,87 66 119 0,08 0 3.ZKE 5 Mb- 45 965 IE3 94,0 94,0 93,3 0,88 79 145 0,5 300 3.ZKE 50 Ma- 55 97 IE3 94,3 93,8 9,4 0,90 94 177 0,44 400 3.ZKE 80 Sa- 75 973 IE3 94,7 94,7 93,8 0,91 19 41 0,74 50 3.ZKE 80 Mb- 90 975 IE3 95,0 95,0 94,3 0,9 149 89 0,88 610 3.ZKE 315 Sa- 110 970 IE3 95, 95, 94,4 0,91 183 354 1,17 695 3.ZKE 315 Mb- 13 970 IE3 95,4 95,4 94,5 0,91 0 44 1,4 870 3.ZKIE 315 Mc- 160 985 IE3 95,6 95,0 93,5 0,90 69 51,0 1150 3.ZKIE 315 Md- 00 980 IE3 95,8 95,6 94,9 0,91 33 641,5 1310 3.ZKIE 315 Lf- 50 980 IE3 95,8 95,5 94,7 0,91 414 801 4,7 1460 3.ZKIE 315 Lg- 315 98 IE3 95,8 95,5 94,5 0,90 58 1009 5,4 1740 3.ZKIE 355 Ma- 50 984 IE3 95,8 95,3 93,8 0,89 44 800 4,7 1550 3.ZKIE 355 Mb- 315 983 IE3 95,8 95,8 94,9 0,91 5 1008 5,4 1770 3.ZKIE 355 Mc- 355 983 IE3 95,8 95,7 95, 0,9 58 1137 5,7 1980 3.ZKIE 355 Ld- 400 98 96,7 0,9 650 181 6,5 550 3.ZKIE 355 Le- 450 98 96,7 0,9 730 1441 6,9 770 3.ZKIE 355 Lf- 500 98 96,7 0,9 81 1600 7,5 910 Bigger motors on request

Electrical data 5 Voltage: 400 V, 50 Hz, F/B, IP55 Series 3.ZKE Type Output Pn Full load R.P.M. IE Efficiency ηn Power factor cosφn Full load Current In Rated torque Tn Moment of inertia J kw min -1 100%Pn 75%Pn 50%Pn A Nm kgm kg Weight 1500 min -1 3.ZKE 00 Lb-4 30 1475 IE3 93,6 93,3 91,8 0,84 55 194 0,30 50 3.ZKE 5 Sa-4 37 1475 IE3 93,9 93,8 9,1 0,84 68 40 0,4 300 3.ZKE 5 Mb-4 45 1475 IE3 94, 94,1 9,5 0,85 81 91 0,47 330 3.ZKE 50 Ma-4 55 148 IE3 94,6 94,5 93,5 0,87 97 354 0,74 445 3.ZKE 80 Sa-4 75 1483 IE3 95,0 94,8 93,6 0,85 134 483 1,06 570 3.ZKE 80 Mb-4 90 1483 IE3 95, 95,0 93,9 0,86 159 580 1,36 630 3.ZKE 315 Sa-4 110 1485 IE3 95,4 94,9 9,5 0,87 19 707,1 800 3.ZKE 315 Mb-4 13 1485 IE3 95,6 95,4 94,1 0,88 7 849,54 910 3.ZKIE 315 Mc-4 160 1485 IE3 95,8 95,7 94,6 0,89 71 109 3,6 1110 3.ZKIE 315 Md-4 00 1485 IE3 96,0 95,8 94,9 0,90 335 186 4,3 150 3.ZKIE 315 Lf-4 50 1486 IE3 96,0 95,8 94,4 0,87 433 1607 5,0 1500 3.ZKIE 315 Lg-4 315 1486 IE3 96,0 95,7 94,1 0,88 539 016 6,0 1770 3.ZKIE 355 Ma-4 50 1487 IE3 96,0 95,9 95, 0,88 48 1606 7,6 1750 3.ZKIE 355 Mb-4 315 1489 IE3 96,0 95,7 94,6 0,87 545 00 9,9 1960 3.ZKIE 355 Mc-4 355 1490 IE3 96,0 96,0 95,1 0,88 607 75 13,0 150 3.ZKIE 355 Ld-4 400 149 96,3 0,90 666 560 14,5 545 3.ZKIE 355 Le-4 450 149 96,4 0,90 748 880 17 770 3.ZKIE 355 Lf-4 500 149 96,5 0,91 8 300 19 90

6 Electrical data Series 3.ZKE Type Output Pn Full load R.P.M. IE Efficiency ηn Power factor cosφn Full load Current In Rated torque Tn Voltage: 400 V, 50 Hz, F/B, IP55 Moment of inertia J kw min -1 100%Pn 75%Pn 50%Pn A Nm kgm kg Weight 1000 min -1 3.ZKE 00 La-6 18,5 983 IE3 91,7 91,9 89,9 0,8 36 180 0,5 30 3.ZKE 00 Lb-6 980 IE3 9, 9,3 90, 0,81 43 14 0,70 60 3.ZKE 5 Mb-6 30 985 IE3 9,9 93,1 90,6 0,85 55 91 0,656 340 3.ZKE 50 Ma-6 37 987 IE3 93,3 93, 91,7 0,84 68 358 0,90 400 3.ZKE 80 Sa-6 45 988 IE3 93,7 93,6 91,8 0,86 81 435 1,50 515 3.ZKE 80 Mb-6 55 989 IE3 94,1 93,8 9,1 0,87 97 531 1,8 570 3.ZKE 315 Sa-6 75 988 IE3 94,6 94,3 9,6 0,87 13 75,70 760 3.ZKE 315 Mb-6 90 988 IE3 94,9 94,8 93,3 0,87 158 870 3,18 870 3.ZKIE 315 Mc-6 110 988 IE3 95,1 95,0 93,1 0,86 194 1063 5,5 1080 3.ZKIE 315 Md-6 13 988 IE3 95,4 95, 93,0 0,86 3 176 6,6 100 3.ZKIE 315 Me-6 160 987 IE3 95,6 95,5 93,9 0,88 75 1548 7,0 1300 3.ZKIE 315 Lf-6 00 990 IE3 95,8 95,4 93, 0,86 351 199 7,5 1500 3.ZKIE 315 Lg-6 50 990 IE3 95,8 95,5 93,1 0,86 439 41 9,3 1750 3.ZKIE 355 Ma-6 00 990 IE3 95,8 95,5 93,9 0,88 343 199 13,1 1700 3.ZKIE 355 Mb-6 50 990 IE3 95,8 95,7 94,8 0,88 49 41 14,9 1980 3.ZKIE 355 Mc-6 315 990 IE3 95,8 95,9 95,5 0,88 540 3039 14,5 40 3.ZKIE 355 Ld-6 355 990 IE3 95,8 96,0 95,6 0,88 609 344 18 500 3.ZKIE 355 Le-6 400 990 96,0 0,89 676 3858 0 700

Electrical data 7 Series 3.ZKE Type Output Pn Full load R.P.M. IE Efficiency ηn Power factor cosφn Full load Current In Rated torque Tn Voltage: 400 V, 50 Hz, F/B, IP55 Moment of inertia J kw min -1 100%Pn 75%Pn 50%Pn A Nm kgm kg Weight 750 min -1 3.ZKE 00 Lb-8 15 75 87,9 87,9 86, 0,70 35, 199 0,3 05 3.ZKE 5 Sa-8 18,5 735 89,1 88,9 87,4 0,75 40 40 0,47 45 3.ZKE 5 Mb-8 735 90, 90,1 89, 0,75 47 86 0,56 85 3.ZKE 50 Ma-8 30 735 91,1 90,8 89,4 0,78 61 390 0,87 370 3.ZKE 80 Sa-8 37 735 91,7 91,6 90,3 0,78 75 481 1,5 495 3.ZKE 80 Mb-8 45 735 9,3 9,1 90,9 0,78 90 585 1,8 580 3.ZKE 315 Sa-8 55 739 9,7 9,4 91,1 0,81 106 710,6 750 3.ZKE 315 Mb-8 75 740 93,4 93,0 91,6 0,81 143 970 3,3 803 3.ZKIE 315 Mc-8 90 74 93,8 93,6 9,3 0,78 178 1158 6,3 1045 3.ZKIE 315 Md-8 110 74 94,1 94,0 9,6 0,79 14 1416 7,8 1150 3.ZKIE 315 Me-8 13 74 94,5 94,4 93, 0,79 56 1699 8,9 170 3.ZKIE 315 Lf-8 160 739 94,7 94,5 93,3 0,81 301 068 7,5 1450 3.ZKIE 315 Lg-8 00 739 94,9 94,8 93,8 0,80 381 585 9,3 170 3.ZKIE 355 Ma-8 160 743 94,7 94,6 93,5 0,8 98 060 19, 185 3.ZKIE 355 Mb-8 00 744 94,9 94,9 93,9 0,8 381 570,4 090 3.ZKIE 355 Mc-8 50 744 94,9 94,7 93,4 0,8 464 309 6, 440 3.ZKIE 355 Ld-8 315 745 94,9 94,9 93,8 0,8 585 4038 8,0 810 3.ZKIE 355 Le-8 355 745 94,9 94,9 94,0 0,8 659 4550 30,0 3035

8 Motor dimensions IM B3 - IM 1001 Type Poles A AA AB AC B BA BB C D DA DB DC E EA F FA GA GC H HA HC HD I K L LC U 3.ZKE 00 La,6 Lb,4,6,8 318 80 398 395 305 95 375 133 55 55 M0 M0 110 110 16 16 59 59 00 35 398 514 395.5 18 764 876 M50x1.5 3.ZKE 5 Sa 4,8 86 355 60 60 140 140 18 18 64 64 43 805 96 356 90 446 418 110 149 55 55 M0 M0 110 110 16 16 59 59 5 35 438 56 414.5 18 800 97 Mb 311 380 4,6,8 60 60 140 140 18 18 64 64 444.5 830 987 M50x1.5 3.ZKE 50 Ma 60 60 64 64 406 96 506 474 349 95 430 168 M0 M0 140 140 18 18 4,6,8 65 65 69 69 50 40 487.5 610 48.5 4 906 1060 M50x1.5 3.ZKE 80 Sa Mb 65 65 18 18 69 69 368 450 4,6,8 75 75 0 0 79,5 79,5 457 110 567 510 11 190 M0 M0 140 140 65 65 18 18 69 69 419 500 4,6,8 75 75 0 0 79,5 79,5 80 45 536 659 514 973 118 4 539.5 104 1179 M50x1.5 3.ZKE 315 Sa Mb 65 65 140 140 18 18 69 69 559 107 119 406 500 4,6,8 80 80 170 170 85 85 589 110 179 508 15 633 56 10 16 M0 M0 315 50 599 74 8 65 65 140 140 18 18 69 69 584.5 113 170 457 550 4,6,8 80 80 170 170 85 85 614.5 1153 1330 M63x1.5 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

Motor dimensions 9 IM B5, V1 - IM 3001, 3011 Type Poles Flange AC AD D DA DB DC E EA F FA GA GC HB I L LA LC M N P S Z T V U 3.ZKE 00 3.ZKE 5 La,6 FF 350 395 314 55 55 M0 M0 110 110 16 16 59 59 60 395.5 764 0 876 350 300 400 Ø18.5 4 5 514 M50 x 1.5 Lb,4,6,8 Sa 4,8 60 60 140 140 18 18 64 64 43 805 96 FF 400 418 337 55 55 M0 M0 110 110 16 16 59 59 75 414.5 800 0 97 400 350 450 Ø18.5 8 5 56 M50 x 1.5 Mb 4,6,8 60 60 140 140 18 18 64 64 444.5 830 987 3.ZKE 50 Ma 60 60 64 64 FF 500 474 360 M0 M0 140 140 18 18 4,6,8 65 65 69 69 99 48.5 906 1060 500 450 550 Ø18.5 8 5 635 M50 x 1.5 3.ZKE 80 Sa Mb 65 65 18 18 69 69 4,6,8 75 75 0 0 79,5 79,5 FF 500 510 379 M0 M0 140 140 65 65 18 18 69 69 4,6,8 75 75 0 0 79,5 79,5 37 514 973 118 500 450 550 Ø18.5 8 5 654 M50 x 1.5 539.5 104 1179 3.ZKE 315 Sa Mb 65 65 140 140 18 18 69 69 559 107 119 4,6,8 80 80 170 170 85 85 589 110 179 FF 600 56 47 M0 M0 345 5 600 550 660 Ø4 8 6 757 M63 x 1.5 65 65 140 140 18 18 69 69 584.5 113 170 4,6,8 80 80 170 170 85 85 614.5 1153 1330 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

10 Motor dimensions IM B3 - IM 1001 AG U Type Poles A AA AB AC AG B BA BA1 BB C D DA DB DC E EA F FA GA GC H HA HD K L LC U 3.ZKIE 315 Mc, Md 65 65 M0 M0 140 140 18 18 69 69 176 146 508 10 633 655 403 457 508 10 15 588 16 315 40 850 Ø8 Mc, Md, 4,6,8 90 90 M4 M4 170 170 5 5 95 95 1306 1486 Me xm63x1.5 Le, Lf 65 65 M0 M0 140 140 18 18 69 69 1587 173 560 10 680 655-560 630 10 0 780 00 315 40 850 Ø8 Lf, Lg 4,6,8 90 90 M4 M4 170 170 5 5 95 95 1617 179 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

Motor dimensions 11 IM B35 - IM 001 AG U Type Poles Flange A AA AB AC AG B BA BA1 BB C H HA HD K L LA LC M N P S Z T U 3.ZKIE 315 Mc, Md Mc, Md, Me 176 146 FF 600 508 10 633 655 403 457 508 10 15 588 16 315 40 850 Ø8 5 4,6,8 1306 1486 Le, Lf 1587 173 FF 740 560 10 680 655-560 630 10 0 780 16 315 40 850 Ø8 5 Lf, Lg 4,6,8 1617 179 600 550 660 Ø4 8 6 740 680 800 Ø4 8 6 xm63x1,5 Type Poles D DA DB DC E EA F FA GA GC 3.ZKIE 315 Mc, Md 65 65 M0 M0 140 140 18 18 69 69 Mc, Md, Me 4,6,8 90 90 M4 M4 170 170 5 5 95 95 Le, Lf 65 65 M0 M0 140 140 18 18 69 69 Lf, Lg 4,6,8 90 90 M4 M4 170 170 5 5 95 95 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

1 Motor dimensions IM V1 - IM 3011 AG U Type Pole Flange AC AG D DA DB DC E EA F FA GA GC HB L LA LC M N P S Z T U 3.ZKIE 315 Mc, Md 65 65 M0 M0 140 140 18 18 69 69 176 146 FF 600 655 403 535 5 Mc, Md, 4,6,8 90 90 M4 M4 170 170 5 5 95 95 1306 1486 Me Le, Lf 65 65 M0 M0 140 140 18 18 69 69 1587 173 FF 740 655-535 5 Lf, Lg 4,6,8 90 90 M4 M4 170 170 5 5 95 95 1617 179 600 550 660 Ø4 8 6 740 680 800 Ø4 8 6 xm63x1,5 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

Motor dimensions 13 IM B3 - IM 1001 AG U Type Poles A AA AB AC AG B BA BB C D DA DB DC E EA F FA GA GC H HA HD K L LC U 3.ZKIE 355 Ma, Mb, 560 150 660 54 75 75 M0 M0 140 140 0 0 79,5 79,5 1493 1648 610 Ø8 Mc 1760 1980 4, 6, 8 150 780 750 403 355 35 945 Ld, Le 800 0 980 00 100 100 M4 M4 10 10 8 8 106 106 1890 110 630 Ø35 Lf 4 060 80 xm75x1.5 xm80x1,5 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

14 Motor dimensions IM B35 - IM 001 AG U Type Poles Flange A AA AB AC AG B BA BB C H HA HD K L LA LC M N P S Z T U 3.ZKIE 355 1493 1648 Ma, Mb, 610 560 150 660 54 Ø8 Mc 1760 1980 4, 6, 8 FF 740 150 780 750 403 355 35 945 5 Ld, Le 1890 110 630 630 0 980 00 Ø35 Lf 4 060 80 740 680 800 Ø4 8 6 xm75x1,5 xm80x1,5 Type Poles D DA DB DC E EA F FA GA GC 3.ZKIE 355 Ma, Mb, Mc Ld, Le 75 75 M0 M0 140 140 0 0 79.5 79.5 4, 6, 8 100 100 M4 M4 10 10 8 8 106 106 Lf 4 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

Motor dimensions 15 IM V1 - IM 3011 AG U Type Poles Flange AC AG D DA DB DC E EA F FA GA GC HB L LA LC M N P S Z T U 3.ZKIE 355 Ma, Mb, Mc 75 75 M0 M0 140 140 0 0 79.5 79.5 1493 1760 1648 1980 4, 6, 8 FF 740 755 403 590 5 Ld, Le 100 100 M4 M4 10 10 8 8 106 106 1890 110 Lf 4 060 080 740 680 800 Ø4 8 6 xm75x1.5 xm80x1.5 The fixing dimensions given in thick figures are obligatory according to the recommendation of IEC. All other technical data and dimensions during the future development of motors may undergo some changes and therefore they can be considered as obligatory after our confirmation only. All dimensions are given in millimetres.

16 Note

QUESTIONNAIRE FOR THE OFFER OF ASYNCHRONOUS ELECTRIC MOTORS Enquiry Number: ITEM: Qty: Customer: A MOTOR DATA D POWER TRANSMISSION AND STARTING CONDITIONS 1 Motor type: Three phase Rotor type: Squirrel cage: 1 Coupling type: Slip-ring: 3 Rated output: PN= kw 4 Rated voltage UN= V 3 Number of consecutive startings: Connection: 5 Rated frequency: fn= Hz 6 Rated speed: nn= rpm F 7 Insulation class 8 Duty type: S1 S3 S4 Delta S5 S6 S7 S8 S9 S10 Jm kgm or Terminal box IP: IMB3 IMB5 Brake torque: Nm Brake voltage: V/Hz 15 Rotor data for s lip-ring motors : CCW Both yes no left IR = A 5 Moment of inertia referred to motor shaft : 6 Driven machine special data: C AMBIENT CONDITIONS 5 50 75 100 J= kgm Tacho gen. Resolver Encoder Absolute encoder 8 Motor flange size: M mm, P mm, N mm 9 Second shaft end: yes DA= mm EA= mm 10 F 1 Ambient temperature: C Relative humidity: % 3 Altitude (above sea level): Specific ambient conditions: m 4 Speed sensor: Sensor Type: or Squared 0 N radial load Manufacturer: Speed range: from up to rpm Load torque characteristic: Speed %: Torque Nm: N Converter type: 7 Constant top right 6 Variable speed drive: yes no Power of converter supplied motor kw ot 1 Type: 4 B 4 Terminal box position (DE side view): B DATA ABOUT THE DRIVEN MACHINE Required power: F vibration level mm/s noise level (LpfA) db (A) 5 Shaft load: axial load V,DC UR = V % PN min Temperature rise: 3 Request for: 14 Motor brake: Required speed: per day Duration: or Motor IP: 1 Protection degree: 13 Sense of rotation (DE side view) : CW 3 per day E ADDITIONAL REQUESTS FOR MOTOR EXECUTION 10 Cooling method: IC Cold state: per hour H min IEC 11 Mounting arrangement: Hot state: per hour 1 Motor overload: ED % starts /h 9 Standard: Star B S Starting: no Other requests and limits: ADDITIONAL EQUIPMENT, SPARE PARTS AND DOCUMENTATION 1 Winding temperature protection: PTC, per phase Pt100, per phase Bearing temperature sensor Pt100, per bearing 3 Anti-condesation heaters 4 Packaging: yes V standard oversea Note: H CUSTOMER 1 Company: Address: 3 City: 4 Country: 5 Person: 6 Telefon / Fax: e-mail: 7 The Questionnaire is available on line at http://www.sever.rs/upiti/uen.html

ATB SEVER DOO Magnetna polja 6 4 000 Subotica Serbia Tel. +381 4 665-14 Fax +381 4 665-15 www.atb-motors.com sever @rs. atb-motors.com