Operating instructions Binary level sensor. LI214x /00 04/2016

Similar documents
Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Operating instructions Flow monitors SI5000 SI / / 2007

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating instructions Binary level sensor LMT /00 06/2011

Operating instructions Flow monitors SI / / 2010

Operating instructions Flow monitor SI / / 2013

Operating instructions Flow monitors SI5002 SI5003 SI / / 2012

Operating instructions Flow monitor SI / / 2014

Operating instructions Electronic level sensor LK7 / LK /07 04/2006

Operating instructions Mechatronic flow sensor SBY /00 03/2011

Installation instructions BasicRelay CR / / 2012

Capacitive level sensors CLS 23

HFS - High Frequency Limit Level Sensor

Innovation in level sensing Level measurement for tanks using guided wave radar technology

JUMO MIDAS S05 Pressure transmitter Type

Thermal flow sensor TFS-35

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Continuous level sensor NSK

Installation Instructions Electronic pressure sensor. PX3111 PX322x PX323x PX3244 PX3422 PX911x PX913x

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

BODAS Pressure sensor PR3 series 10

Continuous level sensor NSK

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Thermal flow sensor TFS-35

Level Sensor with G1/2" Thread Hygienic

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Sensor with M12 Thread Hygienic

Overview of types. Technical data

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Level Limit Switch liquiphant FTL 360 / FTL 361

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

optical sensors through-beam, retro-reflective, dif. reflection sensors 2300 visible red light robust metal housing

LFT RADAR MICROONDE GUIDATE CONTROLLI DI LIVELLO. LFT level sensor the all-round talent with TDR technology. Dimensional drawing.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Innovation in pressure sensing Simple-to-set compact electronic pressure switches. Pressure switches

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Types K510 / K520 / K130 / K610 / K620 / K522 (Angle 90 ) Measuring ranges from -60 C to +200 C.

Electronic Circuit Breaker ESS20-0..

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch

HBLT-Wire LEVEL SENSOR For analogue measurements of NH3 and HFC in refrigeration systems

Operating Instructions 07/2013

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

HBSO1 Oil switch. Instruction manual. For detecting oil in refrigeration systems WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Variants of sensors. průmyslová elektronika. Universal use for limit level sensing of liquids and bulk solids

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Proximity sensors SMT/SME-10, for C-slot

Operating Instructions April 2008 SITRANS LVL100

Instruction Manual September 2010 SITRANS LVL200S

Proximity switches and switch brackets

Level Measurement Point level measurement - RF Capacitance switches

Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch

Operating manual. ba55321de LRD Conductivity measuring cell to be installed in pipelines. ba55321de01 12/00

Level Measuring Sensor for Diesel Fuel Tanks

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Operating Instructions OPTISWITCH 4000 C with transistor output

SITRANS P measuring instruments for pressure

Inductive Proximity Sensor

Inductive Special Properties

Pressure Sensors. for liquid and gaseous media

Surface mounting, flush mounting, and DIN track mounting

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Flow measurement FlexFlow PF20H Hygienic flow sensor

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Pressure transmitter for industrial applications Type MBS 4510

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...


1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

User Manual Rittal PMC UPS 6kVA

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Meter FMT II. Operating manual. original operating manual. Translation of the

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Operating instructions Solenoid interlock AZM About this document. Content

Heat Meter Integrator

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Operating instructions Solenoid interlock AZM About this document. Content

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Front panel valves SV

Steering column and sensor

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

2/2 Solenoid Cartridge Valve, Size 10

LTX RF LEVEL SENSOR. Instruction Manual

ACTUATORS POSITION SENSOR

CBI All in One DC UPS Power Solutions

Powerful, durable and quick to mount. Magnetic and cylinder sensors from ifm electronic.

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Operating instructions Solenoid interlock AZM About this document. Content

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Transcription:

Operating instructions Binary level sensor LI214x 704776/00 04/2016

Contents 1 Preliminary note................................................. 3 1.1 Symbols used............................................... 3 2 Safety instructions............................................... 3 3 Functions and features............................................ 4 3.1 Applications................................................ 4 3.2 Restriction of the application area............................... 4 4 Function....................................................... 4 4.1 Measuring principle.......................................... 4 4.2 Features of the unit.......................................... 5 5 Installation...................................................... 5 5.1 Installation location / environment............................... 5 5.2 Mounting................................................... 6 5.3 Set the installation depth...................................... 6 6 Electrical connection.............................................. 7 7 Operating and display elements.................................... 7 8 Settings........................................................ 8 8.1 Set to the empty vessel....................................... 8 8.2 Set to the full vessel.......................................... 8 8.3 Lock / unlock the unit......................................... 8 9 Operation...................................................... 9 10 Maintenance, repair, disposal..................................... 9 11 Scale drawing................................................. 10 12 Technical data................................................. 10 2

1 Preliminary note 1.1 Symbols used Instructions > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note. 2 Safety instructions Please read the product description prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur. Installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator. The unit complies with the standard EN 61000-6-4. The unit may cause radio interference in domestic areas. If interference occurs, the user must take appropriate remedial actions. 3

3 Functions and features The unit monitors the level of liquids in tanks. 3.1 Applications Water, hydrous media, oils, coolant emulsions. 3.2 Restriction of the application area The unit is not suitable for acids, alkalis, granulates, bulk materials. It is not suitable for hygienic areas. Highly conductive foam can trigger a switching operation. Check the consequences by performing a test in your application! Maximum tank pressure: ± 0.5 bar (when mounted using the appropriate mounting accessories; chapter 5.2 Installation procedure). 4 Function 4.1 Measuring principle The unit operates to the capacitive measuring principle. By direct contact with the medium the unit detects whether the maximum level (limit level) is reached and indicates this by a switched signal. Max. level reached Max. level not reached output open (OFF) output closed (ON) The dielectric constant of a medium is important for its detection. Media with a dielectric constant > 1.8 are safely detected. Dielectric constants of common liquids Mineral oil 2 Coolant emulsion 25...75 Glycol 37 Water 80 Water, demineralised 30 Electrically conductive and non conductive media are detected. 4

The unit operates with radial detection characteristics. Therefore media below the active zone are not detected. Despite different electrical properties media are only detected when the active zone (A) is covered. A 4.2 Features of the unit Automatic adjustment function to the medium to be detected by programming buttons ( chapter 8 Settings). This allows reliable detection of media with a very low dielectric constant (e.g. oil). The installation depth determines the level ( 5.3). The unit is virtually immune to almost any kind of build-up on the probe. The position of the switching level within the active zone can however change with build-up. Operating and switching status indication via LED ring. 5 Installation 5.1 Installation location / environment Installation of the unit: from the top ( 5.3). The following minimum distances must be adhered to: Distance tank bottom - end of the probe: 10 mm. Distance metal tank wall - probe: 20 mm. 5

5.2 Mounting The unit is mounted using a mounting clamp or an adapter. The following standard mounting accessories are available: Order no. Material E43000 mounting clamp (for non-pressurised tanks) E43001 flange plate 73-90 with clamp adapter (pressure rating of 0.5 bar) E43002 welding adapter with clamp adapter (pressure rating of 0.5 bar) E43003 mounting adapter G¾ with clamp adapter (stainless steel, pressure rating of 0.5 bar) E43004 mounting adapter G1 with clamp adapter (stainless steel, pressure rating of 0.5 bar) E43005 flange plate 100-125 with clamp adapter (aluminium, pressure rating of 0.5 bar) E43006 flange plate 65-80 with clamp adapter (aluminium, pressure rating of 0.5 bar) E43007 flange plate 54-52x52 with clamp adapter (aluminium, pressure rating of 0.5 bar) E43016 mounting clamp with mounting bracket (for non-pressurised tanks) E43019 mounting adapter G¾ with clamp adapter (brass, pressure rating of 0.5 bar) Further accessories on request. 5.3 Set the installation depth A = response level H = tank height L = probe length L1 = installation depth L2 = extension length L3 MET A L2 H M L3 = installation depth (min.: 60 mm) S M = height mounting adapter L L1 MET = max. immersion depth (Active zone) = 31 mm S = height of the connection piece Select the installation depth L1 so that the MET zone is covered when the response level A has been reached, that is: L1 = (H - A) + MET + S. 6

6 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: 1 4 3 L+ L 2 3 1 4 Pin1 = L+ Pin4 = switching output/ NC Pin3 = L- Core colours of ifm sockets: 1 = BN (brown), 3 = BU (blue), 4 = BK (black) 7 Operating and display elements 1 2 3 1: LED ring green / yellow green: max. level reached / output open (OFF) yellow: max. level not reached / output closed (ON) 2: programming button OUT OFF 3: programming button OUT ON 7

8 Settings Before the first set-up the empty adjustment must be carried out. 8.1 Set to the empty vessel This adjusts the unit to both the empty vessel and the installation conditions (e.g. the set installation depth). Previous settings are deleted. Empty the tank until the medium is at least 20 mm below the end of the probe. Press the programming button (OUT ON) for at least 2 s. > > The yellow LED flashes slowly (approx. 1 Hz) (= unit is in the adjustment mode). > > After the adjustment process the yellow LED is lit continuously (= unit is in the operating mode, sensor zone not covered). 8.2 Set to the full vessel The empty adjustment is sufficient for media with a low dielectric constant (e.g. oils). For aqueous media the sensitivity must be optimised by a full adjustment. The full adjustment does not change the settings of the empty adjustment. Fill the tank until the active zone of the unit is covered. Press the programming button (OUT OFF), keep it pressed for at least 6 s. > > The yellow LED flashes, after 6 s rapidly (approx. 2 Hz), (= device is in the adjustment mode). > > After adjustment the green LED is lit continuously (unit is in the operating mode, sensor zone covered). 8

8.3 Lock / unlock the unit The unit can be locked electronically to prevent unintentional settings. Locking Press both setting buttons simultaneously for 10 s in the operating mode. > > The LED flashes green. > > After the time (> 10 s) has elapsed, the colour of the LED changes from green to yellow (flashing) and the unit is locked. Unlocking Press both setting buttons simultaneously for 10 s in the operating mode. > > The LED continues to indicate the current operating status (no reaction of the LED). > > After the time (> 10 s) has elapsed, the LED flashes green and the unit is unlocked. On delivery: unlocked. 9 Operation When the supply voltage has been applied, the unit is in the operating mode. It carries out its measurement and evaluation functions and switches the output. Operation indication by LED: LED Status / function Green Yellow unit ready for operation, sensor zone covered (output open (OFF)) unit ready for operation, sensor zone not covered (output closed (ON)) 10 Maintenance, repair, disposal Recommended maintenance: Check the probe for build-up from time to time, clean it in case of strong soiling. After removal of the unit or a change of media with dielectric constants that differ greatly (e.g. oil / water) another adjustment should be carried out. It is not possible to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 9

11 Scale drawing M12x1 53 L 16 21,3 16,6 A LED 1 Dimensions in mm 1: programming buttons A: active zone (31 mm) L: probe length in mm: 132 (LI2141) 273 (LI2142) 481 (LI2143) 12 Technical data Operating voltage [V]...10... 36 DC Current rating [ma]...200 Short-circuit protection (pulsed); protected against reverse polarity and overload Current consumption [ma]...< 22 Voltage drop [V]...< 2.5 Dielectric constant medium...> 1.8 Max. tank pressure [bar]... ± 0.5 1) Housing materials... PP-GF orange; TPE-U Materials (wetted parts)... PP Protection... IP 65, IP 67 Protection class...ii Ambient temperature [ C]...0...60 Medium temperature oil [ C]...0...65 Medium temperature water and media similar to water [ C]...0...35 Storage temperature [ C]...-25... 80 Shock resistance [g]... 12 (DIN EN 60068-2-29, 11 ms) Vibration resistance [g]...5 (DIN EN 60068-2-6, 10...2000 Hz) EMC...EN 61000-6-2: 2005 + Corr. 2005...EN 61000-6-4: 2007 1) when mounted using pressure-resistant mounting accessories ( 5.2) More information at www.ifm.com 10

11