PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

Similar documents
Domae. The right solution for distribution boards

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

TX³ RCCBs 2P up to 100 A

DX³ 4-pole RCBO 6000 A/10 ka

Btdin RCBO 6000A up to 63A (2P)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCCBs - ID 4P up to 100 A

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Modular contactor for installation into distribution boards

and other modular devices for low voltage installation

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Modular contactors and relays

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

New DX 3 High rating & breaking capacity

DSE201 Compact design with enhanced protection

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

COMPLETE SOLUTIONS FOR POWER PROTECTION

DPX moulded case circuit breakers

Residential and light commercial. invicta. panelboards

DX³ RCBO 6000 A Phase + Neutral, neutral right side

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

R.C.B.O. SP / 1 module

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Cat N 3. OVERALL DIMENSIONS

QUALITY ASSURANCE & DOCUMENTATION

Phase + Neutral, neutral on right side

Wall mounted switchgear

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Phase + Neutral, neutral on left side

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Low Voltage A GE Power Controls Company. General catalogue

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Industrial Contactors CTX 3 3P 185A - 800A

3 - Protection components Motor circuit-breakers

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

EAD10H80D EAD14H80D EAD17H80D

BETA Switching Switches and Light Indicators

DX³ RCBO 6000A Phase + Neutral, neutral on left

Residual Current Circuit-breaker (RCCB) FH 200 Series

(1,5 modules per pole)

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

For Info: Phone: Fax:

WORKSHOP SPECIFICATIONS

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

RX 3 M.C.B A up to 63 A

ABB STOTZ-KONTAKT GmbH

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

RESIDUAL CURRENT CIRCUIT BREAKER

Protection components

l Suitable for most residential, commercial and light industrial applications

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Technical Journal September 2012

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

RX 3 M.C.B A up to 63 A

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Short form catalogue. Motor protection & control

1.4. Product overview Memera consumer units and devices

NB1 Miniature Circuit Breaker

MCBs and RCDs LR TM 6000

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices

AF40... AF96 3-pole contactors Technical data

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

Effective discrimination of protective devices

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

W Datasheet: DIN Rail Contactors, series AMPARO

Selective main circuit breakers S 750 series Technical Data

01 Spectra Plus - Introduction

ic60a circuit breakers (curve C)

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Miniature Circuit-Breakers (MCBs)

BETA Switching Switching Devices

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

Ready to install Distribution boards, DIN rail mounted equipment, enclosures and connection systems

AThink future. Switch to green. XBoard Consumer Units. stylish and easy to fit.

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Selection Guide Motor Control Device Solutions

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Residual current devices

Transcription:

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements Flush boards have unique flanges which support the wall board between studs, eliminating the need for dwangs Ample wiring room on all sides Removable DIN rails can be workshop as sembled and fitted into boards at final stage Supplied complete with insulated busbars, neutral and earth bars, spare way fillers, circuit labels, earth bonding wire and tag, N & E links Flush board can be fitted to 75mm, (3") walls Available in 1 to 4 rows, 15 60 ways Surface Available in 1 to 4 rows, 10 60 ways Flush Complies to AS/NZ3439.3 Doors and cable entries manufactured from high im pact, UV stabilised engineering grade resin. Glow wire rating = 850 C. Doors open 180. 20mm over hang minimum all around the boards to hide gaps in the wall (DBF Series). Removable front cover allows easy access for wiring and pre-installation of the wall box. Ample room for circuit labelling top and bottom, transparent cover provided to protect labelling. Covers are common to both DBF and DBS Series. Page 2

DBF SERIES 10mm gap under DIN rails to run cables. Boards can be fitted with up to 4 sets of neutral and earth bars. Slotted fixing holes for stud mounting. Removable DIN rails for workshop pre-wiring. Cable entry knockouts run full width of the board. All plastic box. Available in 10, 15 and 30 way boards. DBS SERIES 25mm gap under DIN rails to run cables. Conduit entries top, bottom and back entry on DBS series. Boards can be fitted with up to 4 sets of neutral and earth bars if required. Page 3

INDEX BOARDS & ENCLOSURES DBF Series Flush Mount ing Page 6 CONNECTION SYSTEMS Busbars & Earth/ Neutral Bars Page 11 DBS Series Surface Mounting Page 8 DIMENSIONAL DRAWINGS Pages 22 26 376.00 115.00 392.00 ME Series Surface Mounting Page 9 SE Series Surface Enclosures Page 10 Page 4

INDEX CIRCUIT PROTECTION DE VIC ES MCBs Page 12 CONTROL DEVICES Time Switches Page 18 RCBOs Page 13 Contactors Page 20 RCCBs Page 14 TRANSFORMER Bell Transformer Page 19 Isolating Switch es Page 16 MEASURING DEVICES Meters Page 19 Voltage Surge Protectors Page 17 Page 5

DBF SERIES FLUSH MOUNTING BOARDS PDL s slim-line flush mounting distribution boards are available in 1 4 rows, 10 60 ways. Unique double doors provide minimum projection and 180 opening. The boards can be fitted to 75mm (3") walls. IP40 The cover and top/bottom cable entries are man ufactured from engineering grade resin. Insulated busbars, neutral and earth bars, spare way fillers, circuit labels, earth bonding wire and tag, N & E links are provided. 1 Row, 10 Way Total Cat No. DBF10 Busbar: 1 x 10 Way Insulated N Bar: 2 x 5 Way E Bar: 1 x 9 Way Spare Way Fillers: 1 x 7.5 Way Strip Cover Size: 286W x 258H x 20D Hole Size: 246W x 223H x 80D inc. wallboard 1 Row, 15 Way Total Cat No. DBF15 Busbar: 1 x 15 Way Insulated N Bar: 2 x 7 Way E Bar: 1 x 13 Way Spare Way Fillers: 1 x 7.5 Way Strip Cover Size: 376W x 258H x 20D Hole Size: 335W x 223H x 80D inc. wallboard 2 Rows, 30 Way Total Cat No. DBF30 Busbar: 2 x 15 Way Insulated N Bar: 1 x 13 and 2 x 7 Way E Bar: 2 x 13 Way Spare Way Fillers: 2 x 7.5 Way Strip Cover Size: 376W x 392H x 20D Hole Size: 335W x 357H x 80D inc. wallboard Page 6

DBF SERIES FLUSH MOUNTING BOARDS (Cont) 3 Rows, 45 Way Total Cat No. DBF45 Busbar: 3 x 15 Way Insulated N Bar: 2 x 13 and 2 x 7 Way E Bar: 3 x 13 Way Spare Way Fillers: 2 x 7.5 Way Strip Cover Size: 376W x 526H x 20D Hole Size: 335W x 491H x 80D inc. wallboard 4 Rows, 60 Way Total Cat No. DBF60 Busbar: 4 x 15 Way Insulated N Bar: 3 x 13 and 2 x 7 Way E Bar: 4 x 13 Way Spare Way Fillers: 3 x 7.5 Way Strip Cover Size: 376W x 660H x 20D Hole Size: 335W x 625H x 80D inc. wallboard Dimensional Drawings on Page 22. Page 7

DBS SERIES SURFACE MOUNTING BOARDS PDL s robust surface mounting distribution boards are available in 1 4 rows, 15 60 ways. Extra wiring room is provided for ease of cable entry. Doors open 180 with minimum projection. IP40 The cover and top/bottom conduit entry are manufactured from engineering grade resin. Insulated busbars, neutral and earth bars, spare way fillers, circuit labels, earth bonding wire and tag are provided. 1 Row, 15 Way Total Cat No. DBS15 Busbar: 1 x 15 Way Insulated N Bar: 2 x 7 Way E Bar: 1 x 13 Way Spare Way Fillers: 1 x 7.5 Way Strip Board Size: 376W x 258H x 115D 2 Rows, 30 Way Total Cat No. DBS30 Busbar: 2 x 15 Way Insulated N Bar: 1 x 13 and 2 x 7 Way E Bar: 2 x 13 Way Spare Way Fillers: 2 x 7.5 Way Strip Board Size: 376W x 392H x 115D 3 Rows, 45 Way Total Cat No. DBS45 Busbar: 3 x 15 Way Insulated N Bar: 2 x 13 and 2 x 7 Way E Bar: 3 x 13 Way Spare Way Fillers: 2 x 7.5 Way Strip Board Size: 376W x 526H x 115D 4 Rows, 60 Way Total Cat No. DBS60 Busbar: 4 x 15 Way Insulated N Bar: 3 x 13 and 2 x 7 Way E Bar: 4 x 13 Way Spare Way Fillers: 3 x 7.5 Way Strip Board Size: 376W x 660H x 115D Dimensional Drawings on Page 23. Page 8

ME SERIES SURFACE MOUNTING BOARDS PDL s compact surface mounting distribution boards are available in 5 12 ways. Manufactured from engineering grade resin. The boards are particularly easy to wire due to the open back construction. Insulated busbars, neutral and earth bars, spare way fillers, circuit labels, earth bonding wire and tag are provided. IP40 Utility board 5 Way Cat No. ME5 Busbar: 1 x 5 Way Insulated N Bar: 2 x 7 Way E Bar: 1 x 13 Way Spare Way Fillers: 2 Board Size: 111W x 206H x 102D 9 Way Cat No. ME9 Busbar: 1 x 9 Way Insulated N Bar: 2 x 7 Way E Bar: 1 x 13 Way Spare Way Filler: 4 Board Size: 190W x 206H x 102D 12 Way Cat No. ME12 Busbar: 1 x 12 Way Insulated N Bar: 2 x 7 Way E Bar: 1 x 13 Way Spare Way Fillers: 5 Board Size: 272W x 206H x 102D Dimensional Drawings on Page 24. Page 9

SE SERIES SURFACE MOUNTING ENCLOSURES PDL s surface mounting enclosures are suitable for in dividual or multiple ways of DIN rail mounted devices i.e. MCB, RCD etc. Enclosures are in two parts base and cover with cable entry options via the sur face or rear. 2 Way Cat No. SE2 Minimum Opening: Maximum Opening: 18mm (1 pole) 36mm (2 pole) Back Entry Knockouts: 2 Enclosure Size: 53W x 133H x 70D 4 Way Cat No. SE4 Minimum Opening: Maximum Opening: 18mm (1 pole) 72mm (4 pole) Back Entry Knockouts: 4 Enclosure Size: 89W x 133H x 70D 6 Way Cat No. SE6 Minimum Opening: Maximum Opening: 18mm (1 pole) 108mm (6 pole) Back Entry Knockouts: 6 Enclosure Size: 125W x 133H x 70D Dimensional Drawings on Page 24. Page 10

CONNECTION SYSTEMS Busbars Cat No. MG 15 Earth Bar Cat No. DBF 15/13 Neutral Bar Cat No. DBF 15/12 Earth/Neutral Bar Links Cat No. DBF 15/10 Pole Fillers Cat No. DBF 15/23 7.5 Way pole filler strip to suit all PDL distribution boards and enclosures. Earth Conductor Tags Cat No. 4DBE Page 11

MINIATURE CIRCUIT BREAKERS MCBs The circuit-breakers combine the following functions: - C60a circuit-breakers are used in the domestic sectors where single phase fault levels are less than or equal to 4.5kA. - protection of circuits against short-circuit currents, - protection of circuits against overload currents, - control, - isolation, - protection of persons against indirect contact. - All breakers are tested and comply with IEC898 and AS4898 and have Aus tralian approval. Tripping Characteristics Curve t(s) 10 000 5 000 1h 2 000 1 000 500 200 100 50 20 10 5 2 1.5.2.1.05.02.01.005.002 I / In.001.5.7 1 2 3 4 5 7 10 20 30 50 70100 200300 C Curve for general use. Technical Data C60a Circuit-Breakers c power circuit v voltage rating: 240V AC v number of cycles (O-C): 10 000 v foolproof terminal design - moving barrier prevents incorrect cable insertion - cable strand centering guides ensure correct cable positions and strand grouping v isolation with positive contact indication v bistable din clip, simplifies disassembly c environment v tropicalisation: treatment 2 (relative humidity: 95% at 55 C) v connection: tunnel terminals for the following cables: - up to 25A : 25mm 2 stranded - 32 to 63A : 35mm 2 stranded C Curve Utilisation cables feeding conventional loads. Technical Data c power circuit v tripping curves: the magnetic trip unit operates between 5 and 10 In. Approval No: N13634 4.5 ka MCBs C Curve 1 Pole 6A Cat No. 11354 1 Pole 10A Cat No. 11355 1 Pole 16A Cat No. 11356 1 Pole 20A Cat No. 11357 1 Pole 25A Cat No. 11339 1 Pole 32A Cat No. 11358 1 Pole 40A Cat No. 11359 Dimensional Drawings on Page 25. Page 12

RESIDUAL CURRENT BREAKERS WITH OVERCURRENT PROTECTION RCBOs The DPN Vigi self-contained residual current device carries out complete protection of final circuits (overcurrents and insulation faults). c protection of persons against indirect contact (30mA) c additional protection of persons against direct contact (30mA) Technical Data c voltage rating: 240V AC c breaking capacity: v EN 60.898/EN 61.009: - rated breaking capacity (Icn): 6kA - rated residual breaking and making capacity (phase/earth): 6kA v fast closing v positive contact indication v earth fault visualised on front face c durability (O-C cycle): v mechanical: 20 000 v electrical: - 20A: 20 000-25A: 15 000-32A: 10 000 c environment: v tropicalisation: treatment 2 (relative humidity: 95% at 55 C) c complies to AS 3190 v weight: 190g v connection: tunnel terminals for 10mm 2 flexible or 16mm 2 rigid cables C Curve c tripping curve: the magnetic trip units operate between 5 and 10 In. 1 Pole + Neutral, 6A Cat No. 19541 1 Pole + Neutral, 10A Cat No. 19542 1 Pole + Neutral, 16A Cat No. 19543 1 Pole + Neutral, 20A Cat No. 19544 1 Pole + Neutral, 25A Cat No. 19545 1 Pole + Neutral, 32A Cat No. 19546 1 Pole + Neutral, 40A Cat No. 19547 Dimensional Drawings on Page 25. Page 13

RESIDUAL CURRENT CIRCUIT BREAKERS RCCBs Merlin Gerin s range of residual current circuit breakers (RCCBs) constantly monitor the balance of current flow between phase and neutral. All sockets connected downstream in the same circuit as the RCCB are protected against a fault between Phase and Earth or Neutral and Earth. The RCCBs are tested to and comply with AS3190. They are type A for de tecting alternating and pul sat ing direct ground fault currents. Technical Data Rated Tripping Current IΔn: 30mA Rated Short Circuit Capacity: 10kA Type: A Standards Complying to: AS3190 Terminals Accommodate up to 35mm 2 flexible cables 50mm 2 rigid cables 2 Pole, 40A, 240V Cat No. 23358 2 Pole, 63A, 240V Cat No. 23362 4 Pole, 40A, 415V Cat No. 23382 4 Pole, 63A, 415V Cat No. 23386 Dimensional Drawings on Page 25. Page 14

RCCB SAFETY SWITCH WIRING DIAGRAM RESIDENTIAL APPLICATIONS A RCCB Safety Switch detects a residual leakage current from active or neutral to earth, such as current from active through a person to earth. It does NOT operate on load current or fault currents active to neutral. Test Operation Press trip test T button. c Handle on the RCCB and circuitbreaker should move down to off position. c The RCCB can also be tested by using a test lamp (say 25W) from active to earth on the loadside. c If the unit does not trip, call a qualified electrician. c To restore power, after trip, move RCCB and circuit-breaker handle up for on. This resets the RCCB. Basic Precautions Electricity can be dangerous. Do not regard the RCCB as a substitute for safe electrical practices. Do not inspect or repair equipment that is not isolated. Page 15

ISOLATING SWITCHES The I switches combine the following functions: - control (opening and closing of on-load circuits), - disconnection Technical Data c compliance with standards: v 63 A: EN 60669-1, IEC 669-1 v I 63 and 100, IEC 947-3: - degree of pollution 3 - isolating voltage 500V AC - impulse voltage 6kV - degree of protection IP 4 on the front panel - frequency 50 60 Hz c isolation with positive contact indication c DC application: 48 (110V with 2 series-connected poles) c mechanical endurance: v I 63 and 100: 50,000 operating cycles c electrical endurance: AC22, p.f. = 0.6 v I = 63A: 20,000 operating cycles v I = 100A: 10,000 operating cycles c short-circuit withstand: 20 x In: 1 s c tropicalisation: treatment 2 (relative humidity 95% at 55 C) c connection by tunnel terminals for: v 50mm 2 rigid cables or comb busbars, 35mm 2 supple cables for I 63 and 100 Single Pole Iso lat ing Switches 1 Pole, 63A, 250V AC Cat No. 15013 1 Pole, 100A, 415V AC Cat No. 15090 Double Pole Isolating Switches 2 Pole, 63A, 415V AC Cat No. 15014 2 Pole, 100A, 415V AC Cat No. 15091 Three Pole Isolating Switches 3 Pole, 63A, 415V AC Cat No. 15015 3 Pole, 100A, 415V AC Cat No. 15092 Dimensional Drawings on Page 25. Page 16

VOLTAGE SURGE PROTECTORS ST surge arrestors are designed to protect equipment on energy networks using TN-S, TN-C and MEN earthing systems. They are not recommended on TT systems and are forbidden on IT systems. Each surge arrestor in the range has a specific use: c incomer end protection: v the STM is recommended for a medium to high risk level c secondary protection: v the STD ensures secondary protection of loads to be protected and is placed in a cascading configuration with surge arrestors at the incomer end Common Technical Data c frequency: 50 60 Hz c Uc: 275V c operation indication by means of a mechanical indicator: v white: normal operation v red: surge arrestor must be immediately replaced c disconnection of the short-circuited surge arrestor to be conducted with a circuit-breaker c permissible internal short-circuit current for STD: 10kA c permissible internal short-circuit current for STM and STH: v 1P: 10kA c upstream and downstream terminal connection: v flexible cable: 2.5 to 16mm 2 v rigid cable: 2.5 to 25mm 2 v flexible or rigid cable 10mm 2 if installation with lightning conductor c operating temperature: -25 C, +60 C c storage temperature: -40 C, +70 C c protection class: v IP20 at terminals v IP40 on front panel c weight (g): v 1P: 60 v 1P+N: 106 v 3P: 220 v 3P+N: 250. Standard v IEC 61643-11 class 2 test. Specific Technical Data STM c common mode protection: v Imax (8/20 µs): 40kA v In (8/20 µs): 15kA v Up: 1.2kV. STD c common mode protection: v Imax (8/20 µs): 10kA v In (8/20 µs): 5kA v Up: 1.2kV c differential mode protection: v Imax (8/20 µs): 10kA v In (8/20 µs): 3kA v Up: 1kV Auxiliaries c adaptable remote indication modules, EM/RM STD Cat No. 16600 In: Rated Discharge Current (20 times 8/20 wave): 5kA Imax: Maximum Discharge (once) Current 8/20 wave/max: 10kA STM Cat No. 16604 In: Rated Discharge Current (20 times 8/20 wave): 15kA Imax: Maximum Discharge (once) Current 8/20 wave/max: 40kA MEN Earthing System 1 Phase L1 N disconnection circuit-break C20 L1 receiver or equipment to be protected surge arrestor (1P) main neutral bar MEN link main earth bar Dimensional Drawings on Page 25. Page 17

TIME SWITCHES Merlin Gerin time switches are designed to control heating, light ing, irrigation and hot water cylinders through automatic switch ing. For larger loads above switching capacity of the timers, use MG CT Contactors (see page 20 & 21). 24 Hour Analogue Timer Cat No. 15335 Rated Operational Voltage Ue (~50Hz): 230V AC ± 10% Switching Capacity Maximum Resistive: 16A Maximum Inductive Cos 0.6: 4A Maximum Incandescent: 1350W Minimum Switching Load: None Minimum Programmable Time between switching operations: 15 mins Accuracy: Mains synchronized Operating Temperature: Min -25 C Max +55 C Comes with manual switch ON/Automatic and sealable cover Power Reserve: None Terminal capacities: 2 x 1.5mm 2 24 Hour + 7 Day Digital Timer Cat No. 15725 Rated Operational Voltage Ue (~50Hz): 230V AC ± 10% Switching Capacity Maximum Resistive: 16A Maximum Inductive Cos 0.6: 2.5A Maximum Incandescent: 1000W Minimum Switching Load: None Minimum Programmable Time between switching operations: 1 min Memory Locations: 48 Accuracy: ± 1 sec. Per day Operating Temperatures: Min. -10 C Max + 55 C Power Reserve 3 years Terminal Capacities: 2 x 1.5mm 2 Dimensional Drawings on Page 25. Page 18

BELL TRANSFORMER 8VA Bell Transformer Cat No. 15216 Bell transformers and safety transformers allow for a very low voltage (ELV 8V or 12V) to be obtained from a low voltage network (LV 230V). All Multi 9 transformers are : c safe: primary and secondary circuits are perfectly insulated by each other c resistant to short-circuit currents thanks to the built-in device c class II with terminal shield (optional) Technical Data c primary voltage: 230V AC ± 10% c secondary voltage on load: v 8-12V AC ± 15 % for bell transformers c frequency: 50Hz... 60Hz c compliance with standards : NF EN 60742, EN 61558-1, IEC 61558-1 c approval NF USE c connection: tunnel terminals for cables up to 4mm 2 transformer rated off load reference secondary voltage (V) voltage (V) 15216 8 13 12 18 Note: Transformers have an off load operating voltage that is higher than the rated voltage. For loads that are sensitive to overloads (electro-magnetic circuits), the transformer must be made to operate at ln. After operation of the protection device upon an overload, cut-off the power supply and let the transformer cool down before restart. kw Hour Meter 1P+N 63A 230V Cat No. 17065 ME1 Single-phase digital kilowatt hour meter designed to measure the electrical power consumed by a single-phase circuit. They are equipped with a total meter, a yellow metering indicator light (flashing) and with cabling error indication. Common Technical Data c direct measurement (without CT) up to 63A c compact dimensions v 4 modules of 9mm c U = 230V ± 10%, 50/60Hz c Accuracy class: 2 c -25 C + 55 C c Consumption: 2.5VA c Terminals: power: 16mm 2 c Total meter: v capacity: 999.99MWh v display: in kwh or MWh, with 5 significant digits c Conforms with standard IEC 1036 (with sealable enclosure) Dimensional Drawings on Page 25. Page 19

CONTACTORS The CT modular contactors control single-phase, three-phase and four-phase circuits up to 100A. Common Technical Data c power circuit: v voltage rating: - 250V 1P and 2P - 400V 3P and 4P v frequency: 50 Hz c control circuit: v voltage rating: - 230/240V: -15% +6% v coil frequency: 50Hz c utilisation temperature: -5 C to +60 C c tropicalisation: treatment 2 (relative humidity: 95% at 55 C) c complies with standard: EN 61.095, IEC 1095 c silent operation (< 20 db) for the entire range c connection: v by tunnel terminals v control circuit - with flexible cables: 2 x 2.5mm 2 - with rigid cables: 2 x 1.5mm 2 v power circuit: - with flexible cables: 2 x 2.5mm 2 for 16 and 25A 2 x 10mm 2 for 40 and 63A - with rigid cables: 6mm 2 for 16 and 25A 25mm 2 for 40A and 63A c pilot light on the front face of each device (red indicator light: coil live) c inrush and holding power: type rating consumption holding power (A) inrush (VA) (VA) (W) 1P, 2P 16/25 15 3.8 1.3 3P, 4P 25 34 4.6 1.6 2P 40/63 34 4.6 1.6 3P, 4P 40/63 53 6.5 2.1 Specific Technical Data CT-100A c power circuit: v current ratings at 40 C: 16 to 100A (AC7a category) c power circuit connection v with flexible cables: 2 x 35mm 2 for 100A v with rigid cables: 50mm 2 for 100A c inrush and hold power: type rating consumption holding power (A) inrush (VA) (VA) (W) 2P 100 53 6.5 2.1 4P 100 106 13 4.2 2 Pole, 25A, 240V AC Contactor Cat No. 15959 A1 1 3 2 N/O Contacts A2 2 4 2 Pole, 16A, 240V AC Contactor Cat No. 15956 A1 1 R1 1 N/O, 1 N/C Contact A2 2 R2 2 Pole, 40A, 240V AC Contactor Cat No. 15966 A1 1 3 2 N/O Contacts A2 2 4 Dimensional Drawings on Page 26. Page 20

CT CONTACTORS Lighting Application AC5a and AC5b Categories c the following tables concern all the contactors from the CT range, with or without manual control, for 230V single-phase lighting circuits c they indicate the contactor rating to be chosen according to the number and type of lamps to be controlled. As a guideline, maximum power is also given type of lighting maximum number of lamps application for a given rating 230V single-phase circuit CT contactors power (W) 16A 25A 40A incandescent lamp with or without halogen gas 40 38 57 115 60 30 45 85 75 25 38 70 100 19 28 50 150 12 18 35 200 10 14 26 300 7 10 18 500 4 6 10 1000 2 3 6 12V halogen lamp (on ELV electromagnetic transformer) 20 15 23 42 50 10 15 27 75 8 12 23 100 6 9 18 150 4 6 13 26mm fluorescent tube (single parallel-corrected) 15 15 20 40 18 15 20 40 20 15 20 40 36 15 20 40 40 15 20 40 58 10 15 30 65 10 15 30 115 5 7 14 140 5 7 14 26mm fluorescent tube (single uncorrected) 15 22 30 70 18 22 30 70 20 22 30 70 36 20 28 60 40 20 28 60 58 13 17 35 65 13 17 35 115 7 10 20 140 7 10 20 26mm fluorescent tube (dual serial-corrected) 2 x 18 30 46 80 2 x 20 30 46 80 2 x 36 17 25 43 2 x 40 17 25 43 2 x 58 10 16 27 2 x 65 10 16 27 2 x 118 6 10 16 2 x 140 6 10 16 c to obtain an equivalence on: v three-phase + neutral circuits: multiply the number of lamps and the power indicated in the table by 3 v three-phase without neutral circuits: multiply the number of lamps and the power indicated in the table by 1.7 type of lighting maximum number of lamps application for a given rating 230V single-phase circuit CT contactors power (W) 16A 25A 40A 26mm fluorescent tube (4 tubes, serial correction) 4 x 18 15 23 46 electronic ballast (1 x 26mm tube) 18 74 111 222 36 38 58 117 58 25 37 74 electronic ballast (2 x 26mm tubes) 2 x 18 36 55 111 2 x 36 20 30 60 2 x 58 12 19 38 electronic compact lamp (low consumption) 7 133 200 400 11 80 120 240 15 58 88 176 20 44 66 132 23 38 57 114 low pressure sodium vapour lamp (without correction) 18 18 34 57 35 4 9 14 55 5 9 14 90 3 6 9 135 2 4 6 180 2 4 6 low pressure sodium vapour lamp (with parallel correction) 18 14 21 40 35 3 5 10 55 3 5 10 90 2 4 8 135 1 2 4 180 1 2 5 high pressure sodium vapour lamp (without correction) 70 8 12 20 150 4 7 13 250 2 4 8 400 1 3 5 1000-1 2 high pressure sodium vapour lamp (with parallel correction 70 6 9 18 150 6 9 18 250 2 3 6 400 2 4 8 1000 1 2 4 Heating Application AC7a and AC1 Categories c the following table concerns all the contactors in the CT range, with or without manual control, for 230V single-phase and 400V three-phase heating circuits c it indicates the contactor rating to be chosen according to the power to be controlled and the number of operations a day type of heating maximum power (kw) application for a given rating number of CT contactors operations/day 25A 40A 230V heating 25 5.4 8.6 50 54 8.6 75 4.6 7.4 100 4 6 250 2.5 3.8 500 1.7 2.7 400V heating 25 16 26 50 16 26 75 14 22 100 11 17 250 5 8 500 3.5 6 Small Motor Application AC7b category c the following table concerns all the contactors in the CT range, with or without manual control, for 230V single-phase and 400V three-phase circuits c it indicates the contactor rating to be chosen according to the power of the motor to be controlled small motor maximum power (kw) application type for a given rating CT contactors voltage 25A 40A single-phase motor with capacitor 230V 1.4 2.5 three-phase motor 400V 4 7.5 Page 21

DIMENSIONAL DRAWINGS DBF Series Flush Mounting Boards DBF10 DBF30 258.00 222.40 335.00 RECOMMENDED STUD OR HOLE WIDTH 286.00 392.00 356.40 DBF15 258.00 222.40 376.00 9.5 70.00 12.0 GIB THICKNESS 376.00 70.00 DBF60 DBF45 526.00 490.40 660.00 624.40 70.00 376.00 70.00 376.00 70.00 Page 22

DIMENSIONAL DRAWINGS DBS Series Surface Mounting Boards DBS15 376.00 115.00 DBS30 376.00 115.00 526.00 258.00 392.00 DBS45 376.00 115.00 DBS60 376.00 115.00 660.00 Page 23

DIMENSIONAL DRAWINGS ME Series Surface Mounting Boards ME5 84 206 111 33 77 102 ME9 ME12 84 84 206 206 190 33 77 102 272 33 77 102 SE Series Surface Mounting Enclosures SE2 70.00 53.00 132.40 45.60 36.00 SE4 SE6 70.00 89.00 70.00 125.00 132.40 45.60 132.40 45.60 72.00 108.00 Page 24

DIMENSIONAL DRAWINGS Miniature Circuit Breakers MCBs Residual Current Circuit Breakers RCCBs 4 P 2 P 021-0100 Residual Current Circuit Breakers with Overcurrent Protection RCBOs Voltage Surge Protectors 1P+N 032-0100 159-0100 Isolating Switches Time Switches 2P 057-0997 Page 25

DIMENSIONAL DRAWINGS Standard Contactors 16/25A 1P 2P Standard Contactors 40/63A Bell Transformer 2P 2 modules kw Hour Meter 082-0997 Page 26

Chemical resistance now there s a choice of orange or white* PDL s orange 56 Series is proven to offer chemical resistance in tough industrial situations. Now there s a white version for clean, clinical environments. Here are some good reasons to choose PDL 56 Series orange or white: Chemically-resistant Rated IP66 Fully modular assembly for total versatility Proven in the field PVC compatibility Fully compliant with AS/NZ standards Made in New Zealand * Plugs and connectors are available in orange only Distribution Solution to IP66 Weather Protected Distribution Board IP66 Up to 13 Way (18mm accessories) Additional wiring space both top/bottom Supplied with Base (56E6 size) with dedicated conduit entries Supplied fitted with DIN rail, Earth, and Neutral (2) bars Transparent cover flap Lockable cover Based on industry proven technology and part of the modular PDL 56 Series Complies with AS/NZS3439.3 Ordering Information: Stock code: 56CB13 Available in grey as standard with orange & white available on request Page 27

Schneider Electric products are available through electrical wholesalers New Zealand wide For PDL Electrical Products are designed to ISO 9001 Freecall 0800-652 999, Freefax 0800-101 152 Email sales@nz.schneider-electric.com Online product detail www.pdl.co.nz and www.merlingerin.com NZPDLSUPERBRD0306