GP400 MODULE T ROUBLESHOOTING ES MODEL -- ELECTRICAL SYSTEM TROUBLESHOOTING ES. Figure 4b-1: GP400 Module

Similar documents
HYDRAULIC ES. The following table applies to Figure 5-11, Figure 5-12 and Figure ES ELECTRIC MODEL - HYDRAULIC ES

3084RT DIESEL/DUAL FUEL MODELS

6092RT, 3392RT-T. T ROUBLESHOOTING -- ELECTRICAL SYSTEM TROUBLESHOOTING Figure 4-2: GP400 Module, 6092RT, 3392RT-T

Section 4 TROUBLESHOOTING CONTENTS PAGE

GP400 MODULE T ROUBLESHOOTING -- ELECTRICAL SYSTEM TROUBLESHOOTING. Figure 4a-1: GP400 Module. 4069ERT Service and Parts Manual March 2014 Page 4-5

CONTROLS AND SWITCHES

CONTROLS AND SWITCHES

GP400 MODULE T ROUBLESHOOTING -- ELECTRICAL SYSTEM TROUBLESHOOTING. Figure 4-1: GP400 Module. IBZ Service and Parts Manual December 2013 Page 4-5

J1 Plug Pin Identification

J1 Plug Pin Identification

J1 Plug Pin Identification

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

HANDHELD EZ-CAL -- UPPER CONTROLS BOX

TROUBLESHOOTING -- EZ-CAL SCAN TOOLS



Parts Manual. Speed Level Series. RT - Internal Combustion ES - Electric

Section 55 Chapter 6

DESCRIPTION & OPERATION

Application Engineering

CONTROLLER DIAGNOSTIC GUIDE

SENTINEL *331019* Service Information Manual. (Paper Manual) Rev (CD -ROM)

SECTION 2 - PROCEDURES. Features. 2.6 MOTOR CONTROLLER. Modes of Operation JLG Lift 2-5

Application Engineering

Flight Systems. Replacement for KASSEC DESCRIPTION

N1387 Series Troubleshooting Guide for N Alternators

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Spray Height Controller

Subject Underhood G System Error Codes and Symptoms System or Parts affected

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Model H30 Operation Manual

oubleshooting Guide diesel - gasoline - LPG electric P.O. Box 1160 St. Joseph, MO Fax:

Troubleshooting Manual

Troubleshooting Guide

2004 SUSPENSION. Electronic Suspension Control (ESC) - Corvette. Fastener Tightening Specifications Specification Application

Light Trailer Boom Technical Training. Rev

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

2007 Chevrolet Corvette STEERING Steering Wheel and Column - Corvette. Steering Wheel and Column - Corvette

Automated Control Electronics (ACE ) System Operation and Diagnostics

620 Magnolia Avenue Suite B Ontario, CA (909) Diagnostic and Troubleshooting. Golf Cart. Revision: A Date:

INSTRUMENTATION & CONTROL

Alternative Fuel Engine Control Unit

Class C Hydraulic Leveling System OEM INSTALLATION MANUAL

SECTION Instrument Cluster and Panel Illumination

ATOTH-G Series BLDC Motor Controller. User s Manual

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

Vission 20/20 micro-controller. Operation and service manual Version 2.6

ELECTRICAL SYSTEM RP-7


CE SERVICE AND PARTS MANUAL 2033ES / 2633ES

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

ValveMate 7000 Controller Operating Manual

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

DESCRIPTION & OPERATION

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Kelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual

Job Sheet 5 Hydraulic Unit Circuit

Class C Hydraulic Leveling System OEM INSTALLATION MANUAL

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Troubleshooting Guide

Section 3 Technical Information

Kelly KDC Series/PM Motor Controller User s Manual

Brushed. Brushed. Brushed Motor

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

ATA 49 AUXILIARY POWER UNIT

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR Cat Tractors with standard shoe/drum brakes

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

MATRIX LLC LEVEL CONTROL PANEL

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Maximiser Progressive Controller

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

Auto-Level Troubleshooting (Old Platform) Electronic Control- Prior to 2009, Pressure Switch Control panel #s 2057, 2058, 2795, 2795B

Troubleshooting Guide

Service Manual. For the SCV2832E, SCV2426, Automatic Scrubbers For: Training Troubleshooting

INSTALLATION INSTRUCTIONS. Yamaha G19 Installation Notes

Full Bridge Permanent Magnet DC Motor Controller User's Manual

SCHEMATIC AND ROUTING DIAGRAMS

Service Guide. Service Guide LEVEL BEST. June How to use the Service Guide:

SCHEMATIC AND ROUTING DIAGRAMS

DISCONTINUED. Service Guide. Service Guide LEVEL BEST. June How to use the Service Guide:

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Open Center Compact Valve Custom Installation Guide Rev A

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE

DIAGNOSIS AND TESTING

Installation, Operation and Maintenance Manual

Low usage. Mild climate

Induction Power Supplies

LCI4A3LCD Hydraulic Leveling

INSTALL GUIDE OEM-CH(RS)-CH4-[ADS-CH4]-EN

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

Transcription:

T ROUBLESHOOTING - 3084ES MODEL -- ELECTRICAL SYSTEM TROUBLESHOOTING - 3084ES GP400 MODULE The GP400 module is the brains of the system. It receives and processes a variety of inputs both from the machine and the operator, then controls all the operative functions of the machine. It also has a feature that allows the technician to access and monitor all functionality of the system, along with a technician-friendly series of fault messages that can be accessed through the use of the EZ-Cal scan tool. Flash codes are also provided in case an EZ-Cal scan tool is not available. Such information can be used for preventative maintenance and troubleshooting should a problem arise. A comprehensive list of EZ-Cal accessible information can be found later in this section. The GP400 operates on volts DC and should never be probed or operated with voltage higher than 4 volts DC. Figure 4b-: GP400 Module P4- not used P4- not used P4-3 not used P4-4 not used P4-5 not used P4-6 not used P4-7 not used P4-8 not used P4-9 not used P4-0 Rear Wheel Bypass Valve P4- not used P4- Motor Controller P4-3 not used P4-4 Down Valve P4-5 not used P5- Lift Valve P5- Steer Right P5-3 Steer Left P5-4 Drive Forward P5-5 Drive Reverse P5-6 Alarm P5-7 High Torque P5-8 High Speed P5-9 Hour Meter P5-0 not used P5- not used P5- not used P5-3 not used P5-4 not used P5-5 not used OUTRIGGER VALVES P6- Back Pitching Valve P6- Front Pitching Valve P6-3 Right Pitching Valve P6-4 Left Pitching Valve P6-5 not used P6-6 not used P6-7 not used P6-8 not used P6-9 not used P6-0 not used P6- not used P6- not used P6-3 Axle Lock P6-4 not used P6-5 not used BASE & LOWER CONTROLS P7- Valve Supply P7- Base Selected P7-3 UP - Base P7-4 Platform Selected P7-5 not used P7-6 not used P7-7 DOWN - Base P7-8 not used P7-9 not used P7-0 not used P7- not used P7- not used P7-3 not used P7-4 not used P7-5 not used P- CAN BUS H P- CAN BUS L P-3 Ground P- not used P- not used P-3 not used 4 3 5 3 5 3 5 3 5 3 5 0 P8- Elevation Transducer P8- not used P8-3 not used P8-4 not used P8-5 CE Elevation Transducer P8-6 Pressure Transducer P8-7 not used P8-8 TBM Analog IN P8-9 not used P8-0 not used P8- not used P8- not used P8-3 Ground P8-4 Ground P8-5 Ground EZ-Cal Connection NOT USED Diagnostic LED ART_397 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-5

TROUBLESHOOTING - 3084ES MODEL -- ELECTRICAL SYSTEM TROUBLESHOOTING - 3084ES MATRIX MODULE The Matrix Module is the remote module located inside the upper control box. It received inputs from the operator and relays them to the GP400. Figure 4b-: Matrix Module P4- not used P4- not used P4-3 not used P4-4 Level Indicator Lamp P4-5 Alarm P4-6 DriveEnabled Lamp (Outriggers Option) P4-7 not used P4-8 not used P4-9 not used Diagnostic LED P- Volts DC INPUT: Power-up P- not used P-3 CAN BUS H P-4 Ground P-5 not used P-6 CAN BUS L Matrix Module (inside Upper Control Box) 3 6 9 7 4 3 0 0 3 P- FORWARD / DOWN P- REVERSE / UP P-3 STEER Left P-4 STEER Right P-5 Enable Bar P-6 Potentiometer P-7 not used P-8 not used P-9 not used P-0 Potentiometer P- Potentiometer P- Switch Supply P3- High Speed P3- Switch Supply P3-3 not used P3-4 DRIVE P3-5 LIFT P3-6 NOT USED P3-7 not used P3-8 not used P3-9 not used P3-0 UP Switch P3- DOWN Switch P3- not used ART_359 TERMINAL BLOCK MODULE (TBM) There is a module inside the lower control box, called a TBM (Terminal Block Module) that provides terminal point connections for both positive and ground circuits. A signal from the Emergency Stop circuit activates a load-reduction relay within the TBM that provides ample power to the B+ (positive) terminal strip. This arrangement protects the system against voltage drop conditions that can be detrimental to the electrical system. Figure 4a-3: Terminal Block Module (TBM) GROUND (B ) Connection PLATFORM Selected BASE Selected ANALOG (AMP) COMMON B+ POSITIVE OUTPUT (B+) Supply To various circuits ART_386 November 009 Page 4b-6 3084 Speed Level Sigma Lift Service and Parts Manual

T ROUBLESHOOTING - 3084ES MODEL -- ELECTRICAL SYSTEM TROUBLESHOOTING - 3084ES P600 MOTOR CONTROL MODULE The Motor Control Module operates the electric pump motor with varied speeds depending on operator commands. Pulse-width Modulation provides smooth and controlled operation with maximum battery efficiency. The Motor Controller also converts battery voltage (48 volts DC) to the user-friendly volts DC used throughout the rest of the system. Figure 4b-4: P600 Motor Control Module To: Battery B+ Disconnect Switch To: Pump Motor P 600 CMEC 48V RT 50 60 s/n: 070004 B To: Battery Ground Diagnostic LED P5 EZ-Cal Connection P6 P6- CAN BUS H P6- CAN BUS L P6-3 Ground to GP400 4 P7 P7- CAN BUS H P7- CAN BUS L P7-3 Ground 3 to Upper Controls 3 P8 P8-48 Volts DC INPUT P8-48 Volts DC INPUT 3 P P- Volts DC OUTPUT P- Volts DC OUTPUT P-3 Volts DC OUTPUT P-4 BASE Selected P-5 PLATFORM Selected P-6 Output to EMERGENCY STOP Circuit for Module Activation ART_57 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-7

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL SCAN TOOL EZ-CAL SCAN TOOL The EZ-Cal (MEC part # 90888; not part of the machine) is a hand-held scan tool that interfaces with the system to provide various information and adjustments. The EZ-cal receives its power from the GP400 when connected. The system must be powered up by closing the Battery disconnect switch and pulling both emergency stop switches. You must also select Base or Platform depending on the station you will operate from. USING THE EZ-CAL SCAN TOOL To operate the EZ-cal, plug the cable into the 4-terminal receptacle P9 on the GP400 and power the system up. The EZ-Cal display will illuminate and read HELP: PRESS ENTER. From this point, use the right and left arrows to scroll through the base menus. Once the desired base menu is obtained (i.e. ADJUSTMENTS) press Enter to access sub menus. Use the right and left arrows to scroll through sub menus, press Enter again. The up/down arrows are used to change settings only. Press ESC to back up one level. Figure 4b-5: EZ-Cal Scan Tool Connections - GP400 Module Calibrator MEC P/N 90888 GP400 Control Module 3 5 3 5 3 5 3 5 3 5 4 LED 0 SYMBOL KEY FUNCTIONS GP400 Module Lower Controls Terminal Block Module ESC/ENTER BUTTONS To move back and forth between menu and sub-menu Diagnostic LED LEFT/RIGHT BUTTONS Select menus and setting to be adjusted UP/DOWN BUTTONS Adjust setting values ART_354 November 009 Page 4b-8 3084 Speed Level Sigma Lift Service and Parts Manual

T ROUBLESHOOTING - 3084ES MODEL -- USING THE EZ-CAL WITH THE FLOW CHARTS USING THE EZ-CAL WITH THE FLOW CHARTS Use the EZ-cal Flow Charts as a guide to locate diagnostic information and make adjustments. Each box in the flow chart will have 3 bits of information. Figure 4b-6: EZ-Cal Display Example ART_7 5C- Identification Number UP MAX Personality 6 Default Setting - match with information tables - does not appear on EZ-Cal display The IDENTIFIER (5c): Used to locate this specific personality in the informational charts. Here you can obtain specific information on the individual personalities. The PERSONALITY (Up Max): Identifies the individual personalities. The DEFAULT SETTING: The factory setting. If adjustments are made, they must be returned to default setting. ACCESS LEVEL PROVIDES ACCESS TO CHANGE PERSONALITIES NORMALLY PRESET AT THE FACTORY TO PROVIDE PROPER MACHINE MOVEMENT AT SAFE SPEEDS. PERSONALITIES MUST NOT BE CHANGED WITHOUT PRIOR AUTHORIZATION FROM MEC AND MAY ONLY BE RETURNED TO FACTORY SPECIFICATION AS LISTED IN THE FOLLOWING TABLES. ERROR MESSAGES To obtain error messages from the EZ-cal Connect the EZ-cal as mentioned above. The display will read, HELP:PRESS ENTER. Press Enter to display the current error message. Use the following list of error messages to better understand the fault. Pressing Enter twice will provide a scrolling message of the current error followed by a log of previous errors that may have occurred within recent operation. SCROLLING MESSAGES The EZ-Cal will provide a scrolling message of the current error followed by a log of previous errors that may have occurred within recent operation. Refer to "Scrolling Message" on page 4b-9. FLASH CODES Flash Codes, provided from the GP400 red LED, will also assist in the event an EZ-cal is not available. However, the EZ-cal yields considerably more relevant information. Refer to "EZ-Cal HELP Messages" on page 4b- for flash coded error messages. 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-9

Adjustments & Setup HELP: T ROUBLESHOOTING - 3084ES MODEL -- USING THE EZ-CAL WITH THE FLOW CHARTS Figure 4b-7: EZ-Cal Flow Chart: Adjustments and Setup, ANSI Models DIAGNOSTICS ACCESS LEVEL RUN SYSTEM TEST GP400 MENU 3 4 5 6 ADJUSTMENTS SETUPS ENTER ENTER ENTER ENTER EZ-Cal Flow Chart Chart of SYMBOL KEY FUNCTIONS 3084ES ANSI Models ESC/ENTER BUTTONS To move back and forth between menu and sub-menu LEFT/RIGHT BUTTONS Select menus and setting to be adjusted UP/DOWN BUTTONS Adjust setting values HELP A SYSTEM B 6A CHANGE DEFAULTS 6B 6C 6D 6E HEIGHT LOAD INTERLOCKS SETUPS SETUPS SETUPS ENTER LOGGED HELP PLATFORM C GROUND D INPUTS E ANALOGS F OUTPUTS G MONITOR H LOG See Chart 6A- CUSTOMER 6=XX84ES 6A- MODEL SELECT : : 3:3084ES US 4: 5: 6: 7: 8: 6B- CALIBRATE LEVEL 6B- SHUTDOWN 0: NEVER 6B-3 ELEV SHUTDOWN : LIFT & DRIVE 6B-4 AXLE 3.0 6C- ELEVATION @ 5% 6C- CALIBRATE HEIGHT 6C-3 MIN LIFT.0 sec 6C-4 SAMPLES@ 0.3 sec 6C-5 CORRECTION 3:Y+ 6C-6 SLOWDOWN 6D- CALIBRATE LOAD 6D- FAULTY LOAD -0 6D-3 DYNAMIC SCALE 6D-4 DELAY UP 0.0 sec 6D-5 DELAY DOWN 0.0 sec 6E- TRIGGER ONLY 0.0 sec 6E- TRIGGER WAIT 0.0 sec 6E-3 FUNCTION HOLD 0. sec 6E-4 THROTTLE DELAY 0.0 sec 6E-5 STARTER DELAY 0.0 sec 5A 5B 5C 5D 5E 5F 5G 5H 5I 5J 5K DRIVE DECK OUTRIGGERS GROUND DRIVE LIFT STEER OVERLOAD ALARMS HEIGHTS ELEVATED (not used) LEVELING MODE 5A- FWD MIN 5% 5A- FWD MAX 95% 5A-3 REV MIN 5% 5A-4 REV MAX 95% 5A-5 ACCEL.5 sec 5A-6 DECEL.0 sec 5A-7 MAX HEIGHT 5A-8 POSITRAC 5B- FWD MIN 5% 5B- FWD MAX 5% 5B-3 REV MIN 5% 5B-4 REV MAX 5% 5B-5 ACCEL.5 sec 5B-6 DECEL 5.0 sec 5C- UP MIN 5% 5C- UP MAX 6 5C-3 DOWN MIN (not used) 5C-4 DOWN MAX (not used) 5C-5 ACCEL. sec 5C-6 DECEL 0.5 sec 5C-7 MAX HEIGHT 0 5C-8 ARMGUARD 5D- SPEED 3 5D- DRIVE COMP 5D-3 DRIVE COMP ELEVATED 5D-4 ACCEL 0. sec 5D-5 DECEL 0. sec 5E- OUT MIN 5E- OUT MAX 0 5E-3 IN MIN 5E-4 IN MAX 0 5E-5 ACCEL 3.0 sec 5E-6 DECEL 3.0 sec 5F- OUTRIGGERS 5F- EXTEND 5 5F-3 LEVEL 35% 5F-4 RETRACT 55% 5F-5 DEBOUNCE 0.35 sec 5F-6 INITIAL 0.5 sec 5F-7 FILTER 6 5F-8 X TARGET 0.º 5F-9 Y TARGET 0.º 5G- UP 6 5G- DOWN 5G-3 OUT 5 5G-4 IN 5 5G-5 ACCEL.0 sec 5G-6 DECEL.0 sec 5H- X TRIP.0º 5H- Y TRIP.0º 5H-3 DELAY TRIP.0 sec 5H-4 DELAY CLEAR 0.5 sec 5H-5 0.5 sec ENTER 5I- TRIP@ 5I- LAMP@ 5I-3 ALARM@ 5I-4 @HEIGHT 5I-5 SAFE DOWN 5I-6 DELAY trip.5 sec 5I-7 DELAY clear.5 sec 5I-8 5K-8 OVERLOAD # 5I-8a @HEIGHT 5J- DRIVE 0: NO 5J- LIFT : DOWN 5J-3 : WHEN ELEVATED 5I-8b SCALE 0 5K- ELEVATION@ 5% 5K- MAX DRIVE STD 5K-3 MAX LIFT 0 5K-4 ARMGUARD 5K-5 OVERLOAD 5K-6 SAFE DOWN 5K-7 OVERLOAD# 5C-8a TIME 0.0 sec 5C-8b @HEIGHT 5F-0 SLACK 0.3º 5H-5a 5H-5b 5H-5c @HEIGHT X TRIP Y TRIP.5º.5º ART_393 November 009 Page 4b-0 3084 Speed Level Sigma Lift Service and Parts Manual

T ROUBLESHOOTING - 3084ES MODEL -- USING THE EZ-CAL WITH THE FLOW CHARTS Figure 4b-8: EZ-Cal Flow Chart: Diagnostic, ANSI Models DIAGNOSTIC Use in conjunction with Diagnostic Tables for thorough explaination of readout and values. GP400 MENU DIAGNOSTICS ENTER EZ-Cal Flow Chart Chart of SYMBOL KEY FUNCTIONS 3084ES ANSI Models ESC/ENTER BUTTONS To move back and forth between menu and sub-menu LEFT/RIGHT BUTTONS Select menus and setting to be adjusted UP/DOWN BUTTONS Adjust setting values A SYSTEM A- MODE A- SUPPLY A-3 VALVE SUPPLY A-4 MOTOR VOLTS (ES ONLY) A-5 MOTOR AMPS (ES ONLY) A-6 TEMPERATURE (ES ONLY) A-7 A-8 ED A-9 HEIGHT (CE ONLY) A-0 LOAD (CE ONLY) A- OVERLOADED (CE ONLY) A- NOT USED A-3 ELEVATED A-4 OUTRIGGER A-5 AXLE A-5a LEVEL / OFF LEVEL A-5b LOCKED A-5c ANGLE A-a SUPPLY V DC A-b SUPPLY CAP BANK A-7a FILTERED A-7b LOCAL A-9a HEIGHT % A-9b HEIGHT % A-4a RETRACTED A-4b EXTENDED A-4c STATUS A-4d OUTRIGGER TEST A-4e AUTO RETRACT B PLATFORM B- TRIGGER ON / OFF B- DLD B-3 JOYSTICK B-4 FWD / DWN OFF / ON B-5 REV / UP OFF / ON B-6 LEFT OFF / ON B-7 RIGHT OFF / ON B-8 POSITRAC B-9 NOT USED P4 P4-0 C GROUND C- UP ON / OFF C- DOWN ON / OFF C-3 NOT USED C-4 NOT USED C-5 NOT USED REAR WHEEL BYPASS VALVE P4- MOTOR CONTROLLER P4-4 DOWN VALVE D INPUTS D- P7- V SUPPLY D- P7- BASE SELECTED D-3 P7-3 UP SELECTED D-4 P7-4 PLATFORM SELECTED D-5 P7-5 NOT USED D-6 P7-7 DOWN SELECTED ON = Powered - Rear Wheels in bypass ON = Contactor closed ON = Down Valve activated 4 E ANALOGS LOAD SENSE 3 5 GP400 MICROPROCESSOR ALL CIRCUITS V ONLY E- P8- ANGLE TRANSDUCER E- P8-6 PRESS TRANSDUCER E-3 TBM AMPERAGE 3 5 3 5 F- P4-0 REAR WHEELS F- P4- PROPORTIONAL 3 5 F-3 P4-4 DOWN 3 5 0 P5 F OUTPUTS F-4 P5- LIFT F-5 P5- STEER RIGHT F-6 P5-3 STEER LEFT F-7 P5-4 DRIVE FWD F-8 P5-5 DRIVE REV F-9 P5-6 ALARM F-0 P5-7 HIGH TORQUE F- P5-8 HIGH SPEED F- P5-9 HOUR METER F-3 P5- POWER OUT MANIFOLD & MISC P5- LIFT VALVE P5- STEER RIGHT P5-3 STEER LEFT P5-4 DRIVE FORWARD P5-5 DRIVE REVERSE P5-6 ALARM P5-7 HIGH TORQUE P5-8 HIGH SPEED P5-9 HOUR METER P5- Power Supply B+ P6 P6- P6- P6-3 P6-4 P6-3 P7 P7- P7- P7-3 P7-4 P7-5 P7-7 OUTRIGGER MANIFOLD REAR PITCH VALVE FRONT PITCH VALVE RIGHT ROLLING VALVE LEFT ROLLING VALVE AXLE LOCK VALVES BASE & LOWER CONTROLS BATTERY VOLTAGE from TBM F-4 P6- BACK PITCH F-5 P6- FRONT PITCH F-6 P6-3 RIGHT ROLLING F-7 P6-4 LEFT ROLLING F-8 P6-3 AXLE LOCK BASE SELECTED UP SWITCH (BASE CONTROLS) PLATFORM SELECTED LIMIT SWITCH DOWN SWITCH (BASE CONTROLS) G LOG G- CAL DATE G- SOFTWARE G-3 POWERED ON = Lift Valve activated ON = Alarm activated ON = Meter activated ON=System powered up ON = Valve powered ON = Voltage, OFF = No Voltage ON = Base Controls ON = Up activated ON = Platform Controls NOT USED ON = Down activated ART_394 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-

Adjustments & Setup HELP: T ROUBLESHOOTING - 3084ES MODEL -- USING THE EZ-CAL WITH THE FLOW CHARTS Figure 4b-9: EZ-Cal Flow Chart: Adjustments and Setup, CE Models DIAGNOSTICS ACCESS LEVEL RUN SYSTEM TEST GP400 MENU 3 4 5 6 ADJUSTMENTS SETUPS ENTER ENTER ENTER ENTER EZ-Cal Flow Chart Chart of SYMBOL KEY FUNCTIONS 3084ES CE Models ESC/ENTER BUTTONS To move back and forth between menu and sub-menu LEFT/RIGHT BUTTONS Select menus and setting to be adjusted UP/DOWN BUTTONS Adjust setting values HELP A SYSTEM B 6A CHANGE DEFAULTS 6B 6C 6D 6E HEIGHT LOAD INTERLOCKS SETUPS SETUPS SETUPS ENTER LOGGED HELP PLATFORM C GROUND D INPUTS E ANALOGS F OUTPUTS G MONITOR H LOG See Chart 6A- CUSTOMER =XX84ES 6A- MODEL SELECT : : 3: 4:3084ES CE 5: 6: 7: 8: 6B- CALIBRATE LEVEL 6B- SHUTDOWN 0: NEVER 6B-3 ELEV SHUTDOWN : LIFT & DRIVE 6B-4 AXLE 3.0 6C- ELEVATION @ 5% 6C- CALIBRATE HEIGHT 6C-3 MIN LIFT.0 sec 6C-4 SAMPLES@ 0.3 sec 6C-5 CORRECTION 3:Y+ 6C-6 SLOWDOWN 6D- CALIBRATE LOAD 6D- FAULTY LOAD -0 6D-3 DYNAMIC SCALE 6D-4 DELAY UP 0.0 sec 6D-5 DELAY DOWN 0.0 sec 6E- TRIGGER ONLY 0.0 sec 6E- TRIGGER WAIT 0.0 sec 6E-3 FUNCTION HOLD 0. sec 6E-4 THROTTLE DELAY 0.0 sec 6E-5 STARTER DELAY 0.0 sec 5A 5B 5C 5D 5E 5F 5G 5H 5I 5J 5K DRIVE DECK OUTRIGGERS GROUND DRIVE LIFT STEER OVERLOAD ALARMS HEIGHTS ELEVATED (not used) LEVELING MODE 5A- FWD MIN 5% 5A- FWD MAX 95% 5A-3 REV MIN 5% 5A-4 REV MAX 95% 5A-5 ACCEL.5 sec 5A-6 DECEL.0 sec 5A-7 MAX HEIGHT 5A-8 POSITRAC 5B- FWD MIN 5% 5B- FWD MAX 5% 5B-3 REV MIN 5% 5B-4 REV MAX 5% 5B-5 ACCEL.5 sec 5B-6 DECEL 5.0 sec 5C- UP MIN 5% 5C- UP MAX 6 5C-3 DOWN MIN (not used) 5C-4 DOWN MAX (not used) 5C-5 ACCEL. sec 5C-6 DECEL 0.5 sec 5C-7 MAX HEIGHT 0 5C-8 ARMGUARD 5D- SPEED 3 5D- DRIVE COMP 5D-3 DRIVE COMP ELEVATED 5D-4 ACCEL 0. sec 5D-5 DECEL 0. sec 5E- OUT MIN 5E- OUT MAX 0 5E-3 IN MIN 5E-4 IN MAX 0 5E-5 ACCEL 3.0 sec 5E-6 DECEL 3.0 sec 5F- OUTRIGGERS 5F- EXTEND 5 5F-3 LEVEL 35% 5F-4 RETRACT 55% 5F-5 DEBOUNCE 0.35 sec 5F-6 INITIAL 0.5 sec 5F-7 FILTER 6 5F-8 X TARGET 0.º 5F-9 Y TARGET 0.º 5G- UP 6 5G- DOWN 5G-3 OUT 5 5G-4 IN 5 5G-5 ACCEL.0 sec 5G-6 DECEL.0 sec 5H- X TRIP.0º 5H- Y TRIP.0º 5H-3 DELAY TRIP.0 sec 5H-4 DELAY CLEAR 0.5 sec 5H-5 0.5 sec 5I- TRIP@ 5I- LAMP@ 5I-3 ALARM@ 5I-4 @HEIGHT % 5I-5 SAFE DOWN 8% 5I-6 DELAY TRIP.5 sec 5I-7 DELAY CLEAR.5 sec 5I-8 OVERLOAD 5I-8a @HEIGHT 5J- DRIVE 0: NO 5J- LIFT : DOWN 5J-3 : WHEN ELEVATED 5I-8b SCALE 0 5K- ELEVATION@ 5% 5K- MAX DRIVE STD 5K-3 MAX LIFT 0 5K-4 ARMGUARD 5K-5 OVERLOAD % 5K-6 SAFE DOWN 8% 5K-7 OVERLOAD# 5K-8 # 5C-8a TIME 0.0 sec 5C-8b @HEIGHT 5F-0 SLACK 0.3º 5H-5a 5H-5b 5H-5c @HEIGHT X TRIP Y TRIP.5º.5º ART_395 November 009 Page 4b- 3084 Speed Level Sigma Lift Service and Parts Manual

T ROUBLESHOOTING - 3084ES MODEL -- USING THE EZ-CAL WITH THE FLOW CHARTS Figure 4b-0: Outriggers EZ-Cal Flow Chart: Diagnostic, CE Models DIAGNOSTIC Use in conjunction with Diagnostic Tables for thorough explaination of readout and values. GP400 MENU DIAGNOSTICS ENTER EZ-Cal Flow Chart Chart of SYMBOL KEY FUNCTIONS 3084ES CE Models ESC/ENTER BUTTONS To move back and forth between menu and sub-menu LEFT/RIGHT BUTTONS Select menus and setting to be adjusted UP/DOWN BUTTONS Adjust setting values A SYSTEM A- MODE A- SUPPLY A-3 VALVE SUPPLY A-4 MOTOR VOLTS (ES ONLY) A-5 MOTOR AMPS (ES ONLY) A-6 TEMPERATURE (ES ONLY) A-7 A-8 ED A-9 HEIGHT (CE ONLY) A-0 LOAD (CE ONLY) A- OVERLOADED (CE ONLY) A- NOT USED A-3 ELEVATED A-4 OUTRIGGER A-5 AXLE A-5a LEVEL / OFF LEVEL A-5b LOCKED A-5c ANGLE A-a SUPPLY V DC A-b SUPPLY CAP BANK A-7a FILTERED A-7b LOCAL A-9a HEIGHT % A-9b HEIGHT % A-4a RETRACTED A-4b EXTENDED A-4c STATUS A-4d OUTRIGGER TEST A-4e AUTO RETRACT B PLATFORM B- TRIGGER ON / OFF B- DLD B-3 JOYSTICK B-4 FWD / DWN OFF / ON B-5 REV / UP OFF / ON B-6 LEFT OFF / ON B-7 RIGHT OFF / ON B-8 POSITRAC B-9 NOT USED P4 P4-0 C GROUND C- UP ON / OFF C- DOWN ON / OFF C-3 NOT USED C-4 NOT USED C-5 NOT USED REAR WHEEL BYPASS VALVE P4- MOTOR CONTROLLER P4-4 DOWN VALVE D INPUTS D- P7- V SUPPLY D- P7- BASE SELECTED D-3 P7-3 UP SELECTED D-4 P7-4 PLATFORM SELECTED D-5 P7-5 NOT USED D-6 P7-7 DOWN SELECTED E ANALOGS LOAD SENSE ON = Powered - Rear Wheels in bypass ON = Contactor closed ON = Down Valve activated 4 3 5 GP400 MICROPROCESSOR ALL CIRCUITS V ONLY E- P8- ANGLE TRANSDUCER E- P8-6 PRESS TRANSDUCER E-3 TBM AMPERAGE 3 5 3 5 F- P4-0 REAR WHEELS F- P4- PROPORTIONAL 3 5 F-3 P4-4 DOWN 3 5 0 P5 F OUTPUTS F-4 P5- LIFT F-5 P5- STEER RIGHT F-6 P5-3 STEER LEFT F-7 P5-4 DRIVE FWD F-8 P5-5 DRIVE REV F-9 P5-6 ALARM F-0 P5-7 HIGH TORQUE F- P5-8 HIGH SPEED F- P5-9 HOUR METER F-3 P5- POWER OUT MANIFOLD & MISC P5- LIFT VALVE P5- STEER RIGHT P5-3 STEER LEFT P5-4 DRIVE FORWARD P5-5 DRIVE REVERSE P5-6 ALARM P5-7 HIGH TORQUE P5-8 HIGH SPEED P5-9 HOUR METER P5- POWER SUPPLY B+ P6 P6- P6- P6-3 P6-4 P6-3 P7 P7- P7- P7-3 P7-4 P7-5 P7-7 OUTRIGGER MANIFOLD REAR PITCH VALVE FRONT PITCH VALVE RIGHT ROLLING VALVE LEFT ROLLING VALVE AXLE LOCK VALVES BASE & LOWER CONTROLS BATTERY VOLTAGE from TBM F-4 P6- BACK PITCH F-5 P6- FRONT PITCH F-6 P6-3 RIGHT ROLLING F-7 P6-4 LEFT ROLLING F-8 P6-3 AXLE LOCK BASE SELECTED UP SWITCH (BASE CONTROLS) PLATFORM SELECTED LIMIT SWITCH - NOT USED DOWN SWITCH (BASE CONTROLS) G LOG G- CAL DATE G- SOFTWARE G-3 POWERED ON = Lift Valve activated ON = Alarm activated ON = Meter activated ON = System powered up ON = Valve powered ON = Voltage, OFF = No Voltage ON = Base Controls ON = Up activated ON = Platform Controls NOT USED ON = Down activated ART_396 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-3

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES EZ-CAL RETRIEVE MODE AND HELP MESSAGES NOTE: It is important to understand that an error message will only be available if the red Diagnostic LED is flashing. If the machine is not operating properly and the red Diagnostic LED is not flashing, the trouble may lie with something not monitored by the electronic control system, i.e. a switch, hydraulic valve or wiring damage. There are two different menus that you can access for message retrieval; MODE and HELP. MODE MENU Allows the technician to see the current state of the controller with a short description. Go to, DIAGNOSTICS/SYSTEM/MODE (EZ-Cal Flow Chart, ID# a). Pressing ENTER a second time will provide additional information with certain messages. HELP MENU Provides various HELP messages to identify failure modes. Some error messages may also be identified by counting the number of times the red LED flashes on the controller so that even without access to an EZ-Cal, some simple diagnostics are possible. However, it is recommended to use an EZ-Cal to diagnose problems, and not rely on the LED! The EZ-Cal provides a much higher detail of information. MODE MESSAGE Connect the EZ-Cal (see illustration). The display will read, HELP: PRESS ENTER. Press Rt. arrow to DIAGNOSTICS. Press Enter. Rt. arrow to MODE. Refer to the following list of HELP messages to better understand the nature of the message or fault. If the GP400 does not register a fault, the display will read EVERYTHING OK. SCROLLING MESSAGE Pressing ENTER twice will provide a scrolling message of the current message (if one exists) followed by a log of previous operations and/or errors that occurred immediately prior, starting with most recent. All messages are cleared whenever the system is powered down. Other helpful menus available include DIAGNOSTICS which allows the technician to monitor specific plug input/output information. Refer to EZ-Cal Flow Chart Diagnostics (ANSI Page 4b- CE Page 4b-3). MODE MESSAGES The purpose of MODE is to indicate, in real time, the current state of the controller with a short description. INITIALIZING The system is preparing to operate, immediately after power-on. SHUTDOWN! The system cannot operate for example both the PLATFORM & GROUND inputs are active together. CHECK CANBUS The system cannot operate CANBUS communications is not successful (for example wire damage to the platform) 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-9

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES PLATFORM, GROUND The system is ready to operate, from the upper or lower controls as indicated (selected by the Base/Platform selector switch) GROUND UP, GROUND DOWN, A ground function is operating normally GROUND UP LOCKED, GROUND DOWN LOCKED, A ground function is selected but not allowed (for example, the function switch was closed at power-on) GROUND FAULTY Multiple ground function inputs are active at the same time WAITING FOR TRIGGER A platform function is selected, but the joystick trigger switch is not closed (close the trigger switch to proceed) TRIGGER CLOSED The joystick trigger switch is closed, but no function is selected (select a function to proceed) TRIGGER LOCKED The joystick trigger switch was closed at power-on, or closed for too long with no function selected (check trigger switch) FORWARD, REVERSE A platform drive function is operating normally FORWARD (LEFT), FORWARD (RIGHT), REVERSE (LEFT), REVERSE (RIGHT) A platform drive function is operating normally, with steer also active STEER LEFT, STEER RIGHT A platform steer function is operating normally (without drive) UP, DOWN A platform lift/lower function is operating normally FORWARD LOCKED, REVERSE LOCKED A platform drive function is selected but not allowed (for example, the switch was closed at power-on) LEFT LOCKED, RIGHT LOCKED A platform steer function is selected but not allowed (for example, the switch was closed at power-on) UP LOCKED, DOWN LOCKED A platform lift/lower function is selected but not allowed (for example, the switch was closed at power-on) CHECK DRIVE/LIFT Neither platform drive nor platform lift select is active, or both are active at the same time CHECK JOYSTICK Both platform joystick directions are active at the same time STEER FAULTY Both platform steer directions are active at the same time November 009 Page 4b-0 3084 Speed Level Sigma Lift Service and Parts Manual

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES EXTENDING LEGS Outrigger legs are extending normally RETRACTING LEGS Outrigger legs are extending normally OUTRIGGERS LOCKED An outrigger function is selected but not allowed (for example, the switch was closed at power-on) INTERLOCKED** An interlock shutdown is active, preventing one or more functions. The interlock can be due to many different causes **Press <ENTER> from the MODE display to see the precise cause of the interlock (listed below) press <ESC> from that display to return to the MODE display: TEST MODE The system test mode is active switch power off and on again to clear ED The vehicle is tilted beyond limits, descend, then move vehicle to a more level location OVERLOADED The vehicle platform is overloaded, reduce platform load. (CE option only) TOO HIGH The vehicle platform is too high to allow some functions descend first ARMGUARD During descent, the system is configured to stop movement to provide an armguard delay release and re-select DOWN to continue lowering (CE option only) TOO HOT The EZLIFT heatsink has reached 75ºc, preventing all functions except lowering. Functions will be allowed again when the heatsink cools to below 70ºc. The heatsink temperature can be viewed in the DIAGNOSTICS/SYSTEM/ TEMPERATURE display, ID # a5. The heatsink must be bolted to a significant metal panel of the vehicle, capable of dissipating heat to the environment. UNCALIBRATED The height and/or pressure sensors have not been calibrated see CALIBRATION OF OVER- LOAD SYSTEM (CE option only). If machine is not equipped with Overload system, refer to SETUPS table and change those personalities that do not match the figure listed in the table. EXTERNAL ALL, EXTERNAL DRIVE, EXTERNAL LIFT An external cutout input is preventing functions determine the cause of the external cutout (for example, a limit switch) 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES EZ-CAL HELP MESSAGES In addition to the MODE messages detailed above, the GP400 provides a HELP message to identify failure modes. Some error messages may also be identified by counting the number of times the red LED flashes on the controller so that even without access to an EZ-Cal, some simple diagnostics are possible. However, it is recommended to use an EZ-Cal to diagnose problems, and not rely on the LED! The EZ-Cal provides a much higher detail of information. Connect the EZ-Cal (see illustration). The display will read, HELP: PRESS ENTER. Press Enter to display the current message. Refer to the following list of HELP messages to better understand the nature of the message or fault. If the GP400 does not register a fault, the display will read EVERYTHING OK. Pressing ENTER twice will provide a scrolling message of the current message (if one exists) followed by a log of previous operations and/or errors that occurred immediately prior, starting with most recent. All messages are cleared whenever the system is powered down. NOTE: When using the LED to attempt diagnosis, please note that a DUAL FLASH code is indicated. The LED will flash on/off a certain number of times, pause off for a short delay, then flash on/off a second certain number of times, followed by a much longer pause off. The sequence will then repeat. INFORMATION ONLY MESSAGES The following are information only HELP messages which are not indicative of any possible problem there is no LED flash code (the LED remains on steady): STARTUP! (no flash code) The system has just been powered on and is carrying out some initialization steps prior to being ready to operate. If you select a function during this time, it may be locked out until you release then re-select it. EVERYTHING OK (no flash code) There is no problem with the system it is ready to operate in platform mode when a function is selected. NOTE: If this is the HELP message when a function is selected, check for open-circuit switches or wiring. GROUND MODE ACTIVE! (no flash code) There is no problem with the GP400 it is ready to operate in ground mode when a function is selected. CLOSE TRIGGER (no flash code) A platform function is selected but the trigger switch is not closed. VEHICLE ED (no flash code) The vehicle is tilted beyond the limits, some functions may be prevented. November 009 Page 4b- 3084 Speed Level Sigma Lift Service and Parts Manual

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES FUNCTION ACTIVE MESSAGES The following HELP messages indicate that there is no problem with the GP400 but that a function is active the vehicle should be moving as requested by the operator. DRIVING! (no flash code) LIFTING! (no flash code) LOWERING! (no flash code) STEERING! (no flash code) EXTENDING OUTRIGGERS! (no flash code) RETRACTING OUTRIGGERS! (no flash code) CALIBRATION MESSAGES The following are calibration HELP messages until the machine is properly calibrated for height and/or pressure (as required), many functions will not be available. NOT CALIBRATED Flash Code: / FUNCTIONS LOCKED - NOT CALIBRATED Flash Code: / The height and/or pressure sensors have not been calibrated and are required because of the setup of the GP400. Calibration procedures are accessible from the SETUPS/HEIGHT SETUPS and SETUPS/LOAD SETUPS menus. FAULT: CUSTOMER Flash Code: / The system must be configured to the customer requirements with the EZ-Cal in SETUPS/ CHANGE DEFAULTS menu, scroll to the correct machine from this menu, the press Right Arrow to select the appropriate model. NOTE: Selecting the incorrect customer or model will cause the machine to operate incorrectly or go into fault mode. 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-3

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES SHUTDOWN HELP MESSAGES This section lists shutdown HELP messages functions can be shut down to prevent them being used: SHUTDOWN - CHECK EMS SWITCHES! Flash Code: / The Base/Platform selector switch position indicates the mode in which the system must operate if both are active together; the system does not know how to function FUNCTIONS LOCKED - TEST MODE SELECTED Flash Code: / Test mode is not accessible with this system. Switch power off/on to reset to normal operation FUNCTIONS LOCKED - ARMGUARD (CE option only) Flash Code: / During descent, the System can stop movement for a configurable time, to allow a safety check that no-one is close to the machine. The operator must release and re-select DOWN to continue lowering (after the delay time-out). FUNCTIONS LOCKED OVERLOADED (CE option only) Flash Code: / System overload features are active, and the platform is excessively loaded to allow operation the platform load must be reduced. FUNCTIONS LOCKED UNDERLOADED (CE option only) Flash Code: / System overload features are active, and the platform load is too low to be valid this could be caused by erroneous calibration, a sensor fault, or a change in the vehicle mechanics/ hydraulics. FUNCTIONS LOCKED - TOO HIGH Flash Code: / The platform is raised too high to allow some functions. Certain functions may not be allowed above certain elevations. Check operator s manual or ADJUSTMENTS/HEIGHTS/MAX DRIVE and MAX LIFT to see if drive and/or lift is allowed at all heights. FUNCTIONS LOCKED - ED Flash Code: / The vehicle is tilted too much to allow some functions. Check operator s manual or ADJUSTMENTS//Xtrip and Ytrip, which determine the maximum allowed vehicle tilt. Refer to EZ-Cal Flow Chart Adjustments and Setup. FUNCTIONS LOCKED - EXTERNAL SHUTDOWN Flash Code: / An external shutdown is preventing functions check DIAGNOSTICS/SYSTEM/ MODE/INTER- LOCK to see which external interlock is active. CHECK GROUND INPUT SWITCHES! Flash Code: / There is a problem with the ground function select switches more than one is active at the same time. SELECT DRIVE/LIFT MODE! Flash Code: / There is a problem with the platform drive/lift select switch neither mode is selected. CHECK DRIVE/LIFT SELECT SWITCH! Flash Code: / There is a problem with the platform drive/lift select switch both modes are selected together. CHECK JOYSTICK SWITCHES! Flash Code: / There is a problem with the platform joystick switches both directions are selected together. November 009 Page 4b-4 3084 Speed Level Sigma Lift Service and Parts Manual

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES RELEASE TRIGGER! Flash Code: / The trigger was closed at power-on, or closed for too long with no function selected. RELEASE GROUND SWITCHES! Flash Code: / Ground function switches were closed at power-on. RELEASE JOYSTICK SWITCHES! Flash Code: / Platform joystick switches were closed at power-on, or closed for too long without trigger switch (see SETUPS/INTERLOCKS/TRIGGERwait). RELEASE OUTRIGGER SWITCHES! Flash Code: / Outrigger switches were closed at power-on. WIRING MESSAGES The following are wiring HELP messages problems have been detected which are likely due to vehicle wiring issues: FAULT: ENERGIZED VALVE - CHECK P5 WIRING! Flash Code: 3/ FAULT: VALVE FEEDBACK HIGH - CHECK VALVE WIRING! Flash Code: 3/ There is a voltage on one or more valve outputs, when all outputs are off. Check each valve output to trace where the invalid supply is coming from. FAULT: CAPBANK VOLTAGE TOO HIGH - CHECK LINE CONT! Flash Code: 3/3 The voltage on the B+ stud of the controller (connected to an internal voltage stabilization capacitor bank) is too high when the line contactor is off. B+ stud voltage should be approximately 3 volts at idle. Check the line contactor tips are not welded, and check the power wiring for errors. FAULT: ENERGIZED LINE CONTACTOR - CHECK P5 WIRING! Flash Code: 3/4 There is a voltage on the line contactor coil output, when it is off. Check wiring to the line contactor coil to trace where the invalid supply is coming from. FAULT: MOTOR OVERLOAD! Flash Code: 3/5 The power protection circuits in the controller have activated to protect from extreme overload. Check for short-circuit power wiring; check for a seized or shorted motor. 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-5

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES P600 TEMPERATURE MESSAGES This section lists temperature HELP messages problems have been detected which are likely due to excessive duty cycling or poor heatsinking: FAULT: BAD INTERNAL TEMPERATURE SENSOR! Flash Code: 4/ The heatsink temperature is out of range; if the fault remains, the power controller may have to be replaced. FUNCTIONS LOCKED - TOO HOT! Flash Code: 4/ The heatsink temperature exceeds 75ºc, preventing all functions except lowering. Check for excessive motor current draw; check for good heatsinking to vehicle chassis. SUPPLY MESSAGES The following are supply HELP messages problems have been detected which are likely due to supply issues: FAULT: BAD INTERNAL 5V! Flash Code: 4/ The internal 5V slave supply is out of range; if the fault remains, the controller may have to be replaced. FAULT: BAD INTERNAL SLAVE! Flash Code: 4/ The internal slave is not operating correctly; if the fault remains, the controller may have to be replaced. FAULT: BAD INTERNAL V! Flash Code: 4/3 The internal V supply is out of range; V Supply is generated by the Motor control module and supplied to the GP400. Check for wiring errors between the two modules. If the fault remains, the Motor Controller may have to be replaced. FAULT: BATTERY VOLTAGE TOO LOW! Flash Code: 4/4 The battery supply is too low the batteries must be re-charged. FAULT: BATTERY VOLTAGE TOO HIGH! Flash Code: 4/4 The battery supply is too high check that the correct battery and charger are installed. FAULT: BAD 5V SENSOR SUPPLY - CHECK P- WIRING! Flash Code: 4/5 The 5V sensor supply is out of range; this supply is available to power external 5V-powered sensors check that is has not been overloaded or short-circuited to other wiring (CE models). November 009 Page 4b-6 3084 Speed Level Sigma Lift Service and Parts Manual

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES SENSOR MESSAGES CE MODELS The following are sensor HELP messages problems have been detected which are likely due to sensor issues (CE models). FAULT: CHECK HEIGHT SENSOR Flash Code: 6/ FAULT: CHECK HEIGHT SENSOR Flash Code: 6/ A height sensor is giving an out-of-range voltage (below 0.5V or above 4.5V). FAULT: CHECK HEIGHT SENSORS Flash Code: 6/ When two height sensors are fitted, both should read the same height at all times; this message indicates that the sensors are reading different heights. Check for loose sensors and/or re-calibrate. FAULT: CHECK PRESSURE SENSOR Flash Code: 6/ A pressure sensor is giving an out-of-range voltage (below 0.5V or above 4.5V). FAULT: CHECK ELEVATION SWITCH Flash Code: 6/3 The elevation switch is in disagreement with the height sensor(s). During calibration, the height at which the elevation switch opens (while lifting) and closes (while lowering), is recorded. Subsequently, height and these calibration points are continuously checked any significant difference generates this error. This section lists CANBUS HELP messages problems have been detected with CANBUS communications between different modules (of course, only applicable if more than one module is connected together via CANBUS): FAULT: CANBUS! Flash Code: 6/6 There are problems with CANBUS communications between the different modules; messages expected from one or more module are not being received, or messages intended to one or more module cannot be transmitted. Check for open- and short- circuit problems with CANBUS wiring; ensure that the CANBUS is wired correctly pin-to-pin; ensure that the vehicle chassis is not erroneously shorted to the chassis (for example, due to insulator breakdown in the motor). POWER WIRING MESSAGES The following are power wiring HELP messages problems have been detected which are likely due to power wiring errors: FAULT: CAPBANK VOLTAGE TOO LOW - CHECK STUD WIRING! Flash Code: 7/7 The voltage on the B+ stud of the controller (connected to an internal voltage stabilization capacitor bank) is too low when the line contactor is off (a pre-charge circuit in the module normally applies approximately 3 volts to the capacitor bank). Check the 300 amp fuse, line contactor or power wiring for errors. Also check DC motor for internal grounding. 3084 Speed Level Sigma Lift Service and Parts Manual November 009 Page 4b-7

TROUBLESHOOTING - 3084ES MODEL -- EZ-CAL RETRIEVE MODE AND HELP MESSAGES OTHER MESSAGES The following are other HELP messages: SOME BIG BAD PROBLEM! Flash Code: 9/9 This message should not occur! FACTORY OVERRIDE Flash Code: (fast flashing) When the controller is first shipped, prior to initial calibration, it is configured in a special factory override state. In this state, none of the normal shutdowns or interlocks will occur the vehicle can be freely lifted/lowered and driven irrespective of any calibration needs, vehicle tilt, etc. As soon as an EZ-Cal is connected to the controller, the factory override state is ended. If calibration does not occur, then the factory override state will recur if the EZ-Cal is disconnected and power is switched off/on. IMPORTANT: Never use a vehicle in factory override; this state is ONLY intended for use during manufacture! While factory override is active, the LED is rapidly flashed on/off. November 009 Page 4b-8 3084 Speed Level Sigma Lift Service and Parts Manual

3084ES ELECTRIC MODEL 3084ES ELECTRIC MODEL - HYDRAULIC - 3084ES HYDRAULIC - 3084ES The following table applies to Figure 5-, Figure 5- and Figure 5-3. Callout Description MA- MAIN MANIFOLD CBV Counter Balance Valve, Drive CBV Counter Balance Valve, Drive CL Coil - Speed/Torque/Steer #8 CL Coil - Lift Valve #0 CL3 Coil - Proportional CP Cavity Plug, Stopped CV Check Valve, Load Sense Steer EC Priority Flow Control EP Piloted Poppet Valve - Torque/Speed EP Piloted Poppet Valve - Torque/Speed FD Flow Divider/Combiner FD Flow Divider/Combiner HP Hand Pump, Brake Release LS Load Sense Shuttle MP Manual Push Brake Release Valve OD Orifice Disc, Brakes, 0.035 OPL Orifice Plug, Steering, 0.087 OPL Orifice Plug, Flow Divider Bleed, 0.05 OPL3 Orifice Plug, Flow Divider Bleed, 0.05 OPL4 Orifice Plug, Stopped OPL5 Orifice Plug, Stopped PD Pilot Valve, Series Parallel, 4-Way / 3-Position PD Pilot Valve, Series Parallel, 4-Way / 3-Position PD3 Pilot Valve, Series Parallel, 4-Way / 3-Position PLG4 Port Plug PLG6 Port Plug RV Relief Valve, Lift, 500 PSI RV Relief Valve, Steering, 000 PSI RV7 Relief Valve, 3000 PSI Main SV Spool Valve, Lift, 3-Way SV Spool Valve, Steer, 4-Way / 3-Position SV3 Spool Valve, Series Parallel, 4-Way / 3-Position SV4 Spool Valve, Series Parallel, 4-Way / 3-Position SVD Spool Valve, Drive, 4-Way / 3-Position Callout CYL CYL MA- CV3 CV4 CV5 CV6 CV7 CV8 CV9 CYL4 CYL5 CYL6 CYL7 ORF4 ORF5 RV3 RV4 RV5 RV6 SV8 SV9 MA-3 CYL3 ORF3 SV5 LF LR RF RR SV6 SV7 FL P Description STEERING COMPONENTS Steer Cylinder, Right Steer Cylinder, Left COMPONENTS Combination Valve Manifold - Tilt Check Valve, Tilt, Side/Side Load Sense Check Valve, Tilt, Front/Rear Load Sense Check Valve, 0PSI Oscillating Axle Check Valve, Tilt Cyl, Front/Rear Check Valve, Tilt Cyl, Front/Rear Check Valve, Tilt Cyl, Side/Side Check Valve, Tilt Cyl, Side/Side Tilt Cylinder, Front/Rear Tilt Cylinder, Side/Side Axle Lock Cylinder Axle Lock Cylinder Orifice, 0.040, Tilt, Side/Side Orifice, 0.040, Tilt, Front/Rear Relief Valve, Tilt Cyl Front/Rear, 500 PSI Relief Valve, Tilt Cyl Front/Rear, 500 PSI Relief Valve, Tilt Cyl Side/Side, 500 PSI Relief Valve, Tilt Cyl Side/Side, 500 PSI Spool Valve, Tilt Front/Rear Spool Valve, Tilt Side/Side LIFT COMPONENTS Lift Cylinder Manifold Lift Cylinder Orifice, 0.067 Descend Solenoid Valve, V, Dual Coil Wheel Motors Wheel Motor - Left Front Wheel Motor w/ Brake - Left Rear Wheel Motor - Right Front Wheel Motor w/ Brake - Right Rear Spool Valve - Right Wheel Motor Bypass Spool Valve - Left Wheel Motor Bypass RESERVOIR Filter, 0 Micron, Fluid Return Pump, Hydraulic Fluid May 00 Page 5-4 Speed Level Sigma Lifts Service and Parts Manual

3084ES ELECTRIC MODEL - HYDRAULIC - 3084ES Figure 5-: Hydraulic Schematic - 3084ES OSCILLATING AXLE LOCK CYLINDERS CYL6 CYL7 CYL4 CV6 500 PSI RV3 CYL5 CV8 500 PSI RV5 SV9 LCA LCB LCA LCB SV8 MA- CYLINDER FRONT/REAR CV7 RV4 500 PSI CYLINDER SIDE/SIDE CV9 RV6 500 PSI S ORF4 ø.040 P CV3 S S ORF5 ø.040 CV4 T CV5 S LS T OA ø.067 SV5 MA-3 ORF3 CYL STEERING CYL CYL3 SV6 SV7 LIFT CYLINDER LF RR RF LR B A A B STR STL LFT LFA LFB RRB RRA RFB RFA LRA LRB ORLS PD MA- SV PD CL CL CV OPL3 ø.087 OPL RV EP OPL ø.05 FD ø.05 EP 500 PSI PD3 FD OPL5 Provision for 3/8-6 UNC Orifice Plug OPL6 RV 500 PSI SV CL CBV 3 3 LS SVD a b CBV SV4 OD CL ø.035 MP SV3 CL ORR ORS CP CAVITY VC0- B EC RV7 3000 PSI OPL4 HP T GSTR GP P P PUMP E FL 3084ES HYDRAULIC SCHEMATIC ART_308 Speed Level Sigma Lifts Service and Parts Manual May 00 Page 5-5

3084ES ELECTRIC MODEL - HYDRAULIC - 3084ES Figure 5-: Hydraulic Manifold, Main M - 3084ES TOP BOTTOM PLG4 PD PLG4 PLG4 PD3 PD PLG6 FD PLG6 FRONT PLG4 BACK PLG4 PLG4 SVD FD EP EP SV3 CL3 PLG4 SV4 CL3 T PLG CL SV EC GP HP PLG4 CV SV CL CL LS RV7 ORLS PLG4 LEFT RIGHT PLG4 OPL3 LRB PLG4 OPL LFB RFA RRA RFB RRB LRA CP PLG4 CBV LFA ORR CBV RV PLG4 OPL5 LFT MP OD RV P OPL B PLG4 OPL4 ORS GSTR 3084ES STR HYDRAULIC MANIFOLD M STL ART_30 May 00 Page 5-6 Speed Level Sigma Lifts Service and Parts Manual

3084ES ELECTRIC MODEL - HYDRAULIC - 3084ES Figure 5-3: Hydraulic Manifold, Tilt M - All Models FRONT CV3 SV9 CL CL CV4 SV8 CL CL BOTTOM PLG8 ORF5 PLG4 PLG4 ORF4 LCA LCA OA LCB LCB CV5 LEFT RIGHT P T T LS 3084 All Models ART_3 Speed Level Sigma Lifts Service and Parts Manual May 00 Page 5-7

ELECTRICAL - 3084ES SCHEMATIC Model: / Serial # 3084ES 80005- UP Upper Controls GP400: 50 4 Reference Art #: none TO: BASE Publication Art #: ART_387 J5 BLK BARE RED 3084ES J6 BRN BLU ORG BLK BARE RED 3084ES ELECTRIC MODEL - ELECTRICAL - 3084ES BLU YEL Figure 5-4: Electric Schematic, Upper Controls - 3084ES B B+ P3- P3- P3-3 P3-4 P3-5 P3-6 J7 HORN (option) 45 73 55 BRN YEL ORG BLK BARE RED PLATFORM UNDERSIDE CAN MODULE MAST CAN BUS H CAN BUS L GND V INPUT CAN BUS H CAN BUS L J8 C D E F G H CONTROL BOX CONNECTOR P GP400 MATRIX MODULE 50 4 V INPUT POWER-UP not used CAN BUS H GROUND not used CAN BUS L P- P- P-3 P-4 P-5 P-6 55 BLK BARE CLEAR OFF/RUN E-STOP 45 YEL HORN (option) 73 P FORWARD / DOWN REVERSE / UP STEER LEFT STEER RIGHT ENABLE BAR POTENTIOMETER not used not used not used POTENTIOMETER POTENTIOMETER SWITCH SUPPLY P- P- P-3 P-4 P-5 P-6 P-7 P-8 P-9 P-0 P- P- BLK BLK GRN YEL RED BLK WHT BLK BLK POT ENABLE RIGHT LEFT REV/UP FWD/DOWN JOYSTICK P4 SWITCH SUPPLY SWITCH SUPPLY not used DRIVE LIFT CHOKE / GLOW not used not used UP SWITCH ROLL RIGHT ROLL LEFT & AUTO LEVEL PITCH & ROLL COMMON P3- P3- P3-3 P3-4 P3-5 P3-6 P3-7 P3-8 P3-9 P3-0 P3- P3-40 4 43 4 48 49 438 LIFT/DRIVE PITCH UP PITCH DOWN ROLL RIGHT ROLL LEFT 448 449 HI SPEED HI TORQUE AUTO LEVEL P3 not used not used not used LEVEL INDICATOR LAMP ALARM (CE) not used OVERLOAD LAMP (CE) not used not used P4- P4- P4-3 P4-4 P4-5 P4-6 P4-7 P4-8 P4-9 47 45 430 LAMP OVERLOAD ALARM (CE only) OVERLOAD LAMP (CE only) 55 UPPER CONTROLS May 00 Page 5-8 Speed Level Sigma Lifts Service and Parts Manual

3084ES ELECTRIC MODEL - ELECTRICAL - 3084ES Figure 5-5: Upper Controls Components - 3084ES 3084ES ANSI Matrix Module Light Toggle Switches HIGH SPEED MID RANGE HIGH TORQUE Micro-Switch MODE SELECT LIFT DRIVE Steer Right EMERGENCY STOP Steer Left OFF / RUN Enable Switch Toggle Switches Micro-Switch Reverse/Up Rocker Switch Forward/Down Rocker Switch Cable Connector HORN Button (Optional) 9843 AUTO LEVEL MANUAL LEVEL (Front to Rear) MANUAL LEVEL (Side to Side) Potentiometer ART_388 3084ES CE Overload Alarm Matrix Module OVERLOAD INDICATOR Toggle Switches HIGH SPEED MID RANGE HIGH TORQUE LIFT DRIVE Micro-Switches EMERGENCY STOP Steer Right OFF / RUN Steer Left 9859 Enable Switch 9843 Toggle Switches AUTO LEVEL MANUAL LEVEL (Front to Rear) Micro-Switches Reverse/Up Rocker Switch MANUAL LEVEL (Side to Side) Forward/Down Rocker Switch Potentiometer Cable Connector HORN Button (Optional) ART_389 Speed Level Sigma Lifts Service and Parts Manual May 00 Page 5-9

Model: / Serial # SCHEMATIC 3084ES Serial #80005- UP Lower Control Box - Electric 3084ES 3084ES ELECTRIC MODEL - ELECTRICAL - 3084ES Figure 5-6: Electric Schematic, Lower Control Box - 3084ES Reference Art #: none Publication Art #: ART_37 GP400 MICROPROCESSOR ALL CIRCUITS V ONLY LOWER CONTROL BOX J P P4 P5 P6 P7 P8 CAN BUS H CAN BUS L GROUND REAR WHEEL BYPASS VALVE MOTOR CONTACTOR DOWN VALVE TERMINAL BLOCK MODULE (TBM) P- P- P-3 P4- P4- P4-4 P4-5 P4-6 P4-7 P4-8 P4-0 P4- P4-4 MANIFOLD & MISC LIFT VALVE P5- STEER RIGHT P5- STEER LEFT P5-3 DRIVE FORWARD P5-4 DRIVE REVERSE P5-5 ALARM P5-6 HIGH TORQUE P5-7 HIGH SPEED P5-8 HOUR METER P5-9 P5-4 BACK PITCHING VALVE FRONT PITCHING VALVE RIGHT ROLLING VALVE LEFT ROLLING VALVE AXLE LOCK VALVE P6- P6- P6-3 P6-4 P6-3 P6-5 BASE & LOWER CONTROLS VALVE SUPPLY P7- BASE SELECTED P7- UP SWITCH P7-3 PLATFORM SELECTED P7-4 DOWN SWITCH P7-7 P7-0 P7- P7-3 ANALOG INPUTS ELEVATION TRANSDUCER CE ELEVATION ANALOG IN TBM ANALOG IN GROUND GROUND GROUND P8- P8-5 P8-6 P8-9 P8-3 P8-4 P8-5 44 43 4 47 0 05 04 07 08 0 37 33 3 4 75 76 77 78 5 405 406 404 409 43 407 4 7 5 BASE/PLATFORM SELECT 404 55 405 DOWN DIODE ASSEMBLY 05 05 UP 406 405 EMERGENCY DOWN E-STOP 44 43 4 47 0 05 04 07 08 0 33 3 75 76 77 78 5 407 43 4 5 5 000 55 45 5 56 5 5 5 5 404 405 46 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 5 6 7 8 34 36 38 40 4 44 54 55 56 57 58 59 60 6 6 64 65 66 67 68 69 70 B+ DOWN 405 409 5A BREAKER 408 J 3 4 404 405 7 408 4 HOUR METER CHARGE INDICATOR ALARM 37 5 B 5 56 5 May 00 Page 5-0 Speed Level Sigma Lifts Service and Parts Manual

Model: / Serial # SCHEMATIC 3084ES Serial #80005- UP Base - Electric Reference Art #: none J 3 4 5 6 7 8 9 0 J4* 47 3 0 4 05 5 04 6 07 7 08 8 9 0 0 33 3 5 6 7 8 34 36 38 40 4 44 60 6 6 64 65 66 44 43 4 75 76 77 78 5 407 43 4 54 55 56 5 5 000 57 55 58 45 59 5 56 5 5 5 67 5 68 404 69 405 70 46 Publication Art #: ART_38 REAR WHEELS DOWN VALVE MAIN MANIFOLD AXLE LOCK CYLINDERS 3084ES J5 3 LEVEL MANIFOLD ANGLE TRANSDUCER ELEVATION 3084ES ELECTRIC MODEL - ELECTRICAL - 3084ES Figure 5-7: Electric Schematic, Base - 3084ES 48V 48V 408 408 408 405 404 46 0 5 300A 0A J0 J J 45 BRN 45 5 BLU 5 55 3 ORG 3 55 44 4 BLK 4 44 4 5 BARE 5 BARE 43 6 RED 6 43 AXLE P600 PUMP MOTOR CONTROLLER 48 VDC TO VDC CONVERTER P6- CAN BUS H P6- CAN BUS L P6-3 GROUND P7 P6 CAN BUS H P7- CAN BUS L P7- GROUND P7-3 P8-48 VOLT INPUT P8-48 VOLT INPUT P- VOLT OUTPUT P P- VOLT OUTPUT P-3 VOLT OUTPUT P-4 BASE SELECTED P-5 PLATFORM SELECTED P-6 OUTPUT TO E-STOP CIRCUIT FOR MODULE ACTIVATION 8 HP MOTOR PWM TO MOTOR B+ M MOTOR CONTACTOR J0-56A 56 J0- CAN BUS H CAN BUS L GND V INPUT CAN BUS H CAN BUS L CAN MODULE B P8 48 VDC CHARGER MAIN BATTERY DISCONNECT SWITCH BLK RED TO PLATFORM *J4 Plug contains connections only at points designated by symbol 3 3 PRESSURE TRANSDUCER ANGLE TRANSDUCER 5A VOLTS CHARGE DIODE J 408 CE CERTIFIED 6 VOLTS 6 VOLTS 6 VOLTS 6 VOLTS 5 6 VOLTS 6 VOLTS 6 VOLTS 48 VOLTS BATTERY PACK 6 VOLTS Speed Level Sigma Lifts Service and Parts Manual May 00 Page 5-

9864 9855 3084ES ELECTRIC MODEL - ELECTRICAL - 3084ES Figure 5-8: Lower Controls Components - 3084ES GP400 Module RAISE (Green) LOWER (Green) EMERGENCY STOP PUSH FOR EMERGENCY RAISE STOP HOUR METER CHARGE INDICATOR LOWER Terminal Block Module Master Disconnect Switch PLATFORM OFF BASE TWIST TO RESET 5 AMP BREAKER PLATFORM OFF BASE EMERGENCY LOWERING 5 AMP BREAKER EMERGENCY LOWERING Diagnostic LED 3084ES ANSI ART_390 GP400 Module RAISE (Green) LOWER (Green) EMERGENCY STOP HOUR METER CHARGE INDICATOR Terminal Block Module Master Disconnect Switch 5 AMP BREAKER PLATFORM OFF BASE EMERGENCY LOWERING Diagnostic LED 3084ES CE ART_39 May 00 Page 5- Speed Level Sigma Lifts Service and Parts Manual