POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET

Similar documents
Troubleshooting Bosch Proportional Valves

Table of Contents. Parts Overview 1-3. Tools Needed 4. Recommended Service Parts 4. Gas Fire-Up Check List 5. Troubleshooting Flow Chart 6-9

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

Servo and Proportional Valves

TABLE OF CONTENTS INTRODUCTION.3 WARRANTY INFORMATION 4 SAFETY INFORMATION 5 PREPARING YOUR WATER BEFORE INSTALLATION 6

Installation, Operation & Maintenance Manual

Problems with your 12V Booster?

OnCommand Troubleshooting Guide Hayward Industries

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

User s Manual. Automatic Switch-Mode Battery Charger

Subject Underhood G System Error Codes and Symptoms System or Parts affected

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

Swimming Pool and Spa Purification System. Pool Pilot. by AUTOPILOT SYSTEMS INC. Installation and Operation (For Indoor or Outdoor use)

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Problems with your 12/24V Booster?

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

Mini Pump Installation, Operation & Maintenance Manual. For Models: BA-MS-633

POOL PILOT PROFESSIONAL

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Pool Pilot Soft Touch by AquaCal AutoPilot, Inc.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

MASSLOAD TECHNOLOGIES

Troubleshooting Guide

INSTALLATION INSTRUCTIONS

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

STEP-BY-STEP INSTALLATION GUIDE

TRAIL CHARGER with EXTENDER and COMBO NOSE BOX

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

Modulating Furnace Information. Warning on Meter Setting - Read First!

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

2) Mark wall at 5 10 for center line of bottom bolt-hole in wall brackets on transition box side of floor.

Advanced Troubleshooting Guide Snorkel V Battery Charger Rev 0 3JAN07

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

ECT Display Driver Installation for AP2 Module

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

GENERAL REQUIREMENTS:

Service Manual Gulf Stream Electronic Full Wall Slide Systems

i n s t r u c t i o n m a n u a l

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Electronic Brake Control

6000DC Single 12V Motor Wireless Controller Kits With Extra Options

Model 2300DL Installation Guide

Ebling Back Blade Snow Plow Wireless Controller Kit Only sold by SnowplowsPlus.com and ControlAllWireless.com

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

Table of Contents. General Operation. 3 How Slam-A-Winner plays How the Wheel Scores How the Ball Lift works Programming Options...

Troubleshooting Guide: Elevance Delivery Systems

INSTRUCTION MANUAL. Smart Pressure. Variable Pressure Diagnostic Smoke Machine. with UltraTraceUV Non-Contaminant Dye Solution Model No.

POOL PILOT PROFESSIONAL

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

The ECLIPSE #9800 & The ECLIPSE #9800WC

12/24 Volt Trailer, Caravan Electrical Tow Plug And Light Tester

Troubleshooting Guide

556L General Motors Passlock Interface Module

Instruction & Owner s Manual

12/24 Volt Trailer, Caravan Electrical Tow Plug And Light Tester Basic

Robotic Cleaner Troubleshooting Guide. Copyright 2010 Hayward Industries Inc.

Troubleshooting Guide

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

Grout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram

Analog Condensate Monitor Instruction & Maintenance Manual

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

EPRC-ST Solar Charge Controller

Gateway 505/605 Symptom Flow Chart Lift Interlock

Troubleshooting Guide

EasyStart Installation Instructions for Dometic Family RV A/Cs

Reverse Polarity MANUAL. Surechlor S3500

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

CHEMINSTRUMENTS HOT ROLL LAMINATOR MODEL HL-100, HL-101 OPERATING INSTRUCTIONS

An ISO 9001:2008 Registered Company

Phase 1 Workshop Home Study Guide

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

1998 E-Series Workshop Manual

NOTE. Installation and Service Manual Dual Planetary Gearmotor Slim Rack Slide Out System

Regulated Hose Supply Installation, Operation & Maintenance Manual

180 Lake Ave North Paynesville, MN Phone: (320) MASTER MANUFACTURING MASTER GARDNER

GRD502-B Flow Chart 02/05/09

Model 2300JL Installation Guide

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

TOTAL CONTROL. Total Control Components PART # DESCRIPTION Pool Chemistry Controller

2. Milk does not heat and the heater is not hot. a. Is there power getting to the pasteurizer heater? Check the incoming voltage to the contactor

QuickServe Online ( ) ISB6.7 CM2350 B101 Service Manual

INSTALLER MANUAL USER MANUAL. Contents

6500DC Dual Motor Wireless Controller Kits

TOTAL CONTROL. Total Control Components Pool Chemistry Controller Salt Chlorine Generator Acid Feeder Relay Box (optional)

Third Generation NITE Phoenix

HYDRAULIC LEVELING SYSTEMS OPERATIONS MANUAL (For systems with touch pad part number , , , , or no number at all)

PowerLevel s e r i e s

Technical Information and Diagnostic Guide

PD10-M-RIM INSTALLATION INSTRUCTIONS. The PD10-M-RIM is a storefront grade 1 exit device equipped with motor drive latch retraction.

GLOBE FLOWCELL. Operating Manual. Rola-Chem Flowcell PN /01/2013 page: 1 of 8

Installation & Service Manual

PAGE Both power cords must be connected & powered to operate the E-TES 120.

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

Digital by AUTOPILOT SYSTEMS INC.

Table No. 1 provides a means of identifying the various alternator systems. Note: All output figures are rated at 3600 RPM. TABLE NO.

Commercial Chlorine Generating Device LECTRANATOR II. The Next Generation POOL PILOT PROFESSIONAL REGISTRATION NO PEST CONTROL PRODUCTS ACT

Page 1 of 1 ALTERNATORS. Overview. Intek TM V-Twin Cylinder OHV Engine Service Manual Version 1.0. Copyright 1999 by Briggs and Stratton Corporation

Transcription:

POOL PILOT SOFT TOUCH OPERATING, TROUBLESHOOTING AND TECHNICAL CHEAT SHEET NORMAL OPERATING MODE OF SOFT TOUCH 1. Output Lights will pulsate to indicate Chlorine production. a. There are 7 lights to indicate output level. b. Chlorine Production is based upon an on/off period of a 30-minute cycle. c. If lights are solid Green this means unit is in rest mode. d. To increase percentage of chlorine production, press UP ARROW e. To decrease percentage of chlorine production, press DOWN ARROW (The lights will display between 1 light up to 7 lights to reflect output level) 2. Flow Light will be Green a. If Flow light is not on see troubleshooting section. 3. Salt Light will be Green (OK) unit will produce chlorine 4. If Salt light is Yellow (LOW) add salt until Green Salt light comes on or check with Salt addition chart for proper amount i. The Yellow Salt light comes on at 2500 ppm and unit will still produce chlorine. 5. If Salt light is Red (ADD) ---unit will engage safety cell shut off. Unit will automatically resume operation when salt is added back to sufficient levels. i. The Red Salt light comes on below 2000 ppm of salt. 6. Pushing the BOOST BUTTON will increase chlorine production to 100% for 24 hours of accumulative pump run time. The GREEN BOOST LIGHT will stay Solid Green a. Holding the Boost Button down from Boost OFF mode for 8 seconds will increase the Boost Cycle to 72 hours of accumulative pump run time. The Green Boost light will flash b. After Boost Cycle is complete the unit automatically reverts to the original Setting c. Depress the Boost button in either Boost mode to deactivate Boost mode.. 1/17/03 1

SOFT TOUCH TROUBLESHOOTING **If the service light comes on, count the number of flashes and see below?? 1 RED FLASH = LOW FLOW OR NO FLOW The flow light will go out and the Service light will flash once o Verify the that the filter is clean If filter is dirty, clean the filter to increase the overall flow. o Verify the water exiting the filter is not being diverted away from the inlet of the manifold. Make sure they do not have valves closed off or water being diverted away to other water features like waterfalls, therapy jets, etc. If they are diverting water away to a water feature, they may have to adjust the valve so more flow goes through the tri sensor to activate the flow. REMINDER: you need at least 15 GPM going through the flow switch to activate it. o Verify that the Manifold Strainer Screen is Clean The strainer screen is located in the bottom portion of the manifold on the inlet side. Even if the screen appears clean, run the pump for a few seconds to flush any debris that may have fallen back into the pipes. o The Tri Sensor may have Failed Check Tri Sensor Flow switch for continuity?? See Diagram 4A o Tri Cable may have Failed Check Tri Sensor Cable for Continuity?? Use a multi motion for continuity check?? 2 RED FLASHES Low Amps with Salt OK o Cell may be Scaled If cell is dirty, put cell in bucket with 1 part muriatic acid to 4 parts water for 15- minute intervals until scale is completely removed. HINT: VERIFY CHEMISTRY TO DETERMINE WHY CELL SCALED. If cell scales within a week, unit may not be reversing polarity. If cell scales 2 weeks or longer, water is unbalanced. o 20 amp fuse blown o replace 20 amp fuse o Verify that unit is grounded correctly o On the PS at J3 location verify you have 12 to 12 ½ dc volts. If you do not BAD POWER SUPPLY 1/17/03 2

SOFT TOUCH TROUBLESHOOTING CONT D **If the service light comes on, count the number of flashes and see below.?? 3 RED FLASHES very low amps with Salt OK o V1.4 or older - scaled cell or failed cell o Power Supply may have failed or improperly wired. Check the Power Supply for Output. If you do not get a Volt reading the power supply is bad How to test: The Power Supply has built in diagnostic test (See page 13 of your manual for procedures), or use a 957B tester, put tester in Power Supply mode or a Multimeter and test for Volts.?? Verify unit and incoming voltage match. o Cell cord may have failed Check Cell cord for Continuity How to test: Use a Multi Meter and test for continuity. Center hole is the black wire. o Cell Failure If you get High Volts and Low Amps your cell is bad. How to test: The Power Supply has built in diagnostic test (See page 13 of your manual for procedures), or use a 957B tester, put tester in Cell mode and test for volts and amps.?? 4 RED FLASHES Bad Temperature Sensor (salt will not be temperature compensated) o Replace Tri Sensor 1/17/03 3

MAXIMUM CELL CURRENT (DC AMPS) Cell Power 1 = 5 AMPS Cell Power 2 = 6.5 AMPS Cell Power 3 = 8 AMPS SOFT TOUCH TECHNICAL SPECIFICATIONS SOFT REVERSAL Chlorine Production Stops 30 seconds before reversing polarity. WARNING: Operating on level 1 reduces cell power but extends cell life, operating on level 3 increases cell power but shortens cell life REVERSAL TIME SHORT = Every 2 hours of cell run time NORM = Every 4 hours of cell run time LONG = Every 8 hours of cell run time BOOST CYCLES Solid Green light is 24 hour boost Flashing Green light is 72 hour boost (Hold boost down for 8 seconds to get 72 hour boost) NOTE: REVERSING AND BOOST CYCLE TIMES ARE STORED WHEN POWER GOES OFF, RESTARTING AT THE SAME POINT IN THEIR CYCLE. AUTOMATIC TEMPERATURE COMPENSATION This feature automatically adjusts the output level setting based upon the changes in seasonal water temperatures only. This unique feature conveniently compensates for warm (more purified needed) or cold (less purified needed) water conditions. *Remember that the output level is a time cycle based upon a 30-minute cycle. At 0% output, it is generating 0 of 30 minutes. At 25%, it is generating 7.5/30 minutes. At 50%, it is generating 15/30 minutes. At 75% it is generating 22.5/30 minutes. And at 100% it is generating 30/30 minutes. Temperature Output adjustment 50?F 1% fixed setting 55?F 25% of 70F setting 60?F 50% 65?F 75% 70?F 100% 75?F 125% 80?F 150% 85?F 175% 90?F 200% This is easier explained with the output level at 50% setting. At 70F, a 50% setting is truly 50%, thus generating 15/30 minutes. As the temperature increases to 80F, the 50% setting will still display as 50% but will continue to pulsate (generate) 22.5/30 minutes due to the temperature compensation of 150%. 15 minutes x 150% = 22.5 minutes. As the temperature increases to 90F or higher, the 50% setting will display 50% but will continue to pulsate continually, 30/30 minutes. 15 minutes x 200% = 30 minutes. As the temperature decreases to 65F, the unit will pulsate 11.25/30 minutes. 15 minutes x 75% = 11.25 minutes. As the temperature decreases to 60F, the unit will pulsate 7.5/30 minutes. 15 minutes x 50% = 7.5 minutes. As the temperature decreases to 50F or lower, the unit will pulsate 18 seconds/30 minutes, 30 x 1% =0.30 minute (18 seconds) (**This is true for all output settings at 50F or lower) 1/17/03 4

DIAGRAM 4A TRI-SENSOR CABLE / WIRING DIAGRAM FLOW 5 1 6 SALT 4 2 RED 1 Flow WHITE 2 BROWN 3 Salt GREEN 4 BLACK 5 Temp 3 BLUE 6 TRI-SENSOR CABLE PLUG (FEMALE CONNECTIONS) TEMP. FLOW DETECTOR 1 5 TEMP 6 SENSOR 2 4 SALT 3 SENSOR TRI-SENSOR ASSEMBLY HEAD PLUG (MALE CONNECTIONS) NOTE (Perform these tests on the Tri-Sensor Assembly): - Test for continuity of the FLOW pins by attaching a continuity meter test leads to pins #1 & #2 and manually activating the flow paddle to the center post. - Test for continuity of the SALT pins by attaching a continuity meter test leads to pin #3 and the INSIDE of either of the two the salt blades. Perform same test on pin #4 and the opposite blade. 1/17/03 5

1/17/03 6