DEVICE STATE/BYPASSED FAILURE OVERLOAD

Similar documents
For Operation in the Control Cabinet

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

For Operation in the Control Cabinet

Technical specifications

Low-Voltage Controls and Distribution

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

Siemens AG 2007 July 2007 V 1 N s L w alog Ne Cat sirius Soft Starters 3RW40 for standard applications

Solid State Relays, 3-phase

DIN EN UL 508 / CSA 3RF A A 0 2

SIRIUS 3RU2 Thermal Overload Relays

3RT14 Contactors with 3 Main Contacts

AF40... AF96 3-pole contactors Technical data

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Electronic overload relays EF205 and EF370

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Solid State Relays contactor with Integrated Fuse Type RGC1F

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Industrial Power Supplies

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT


Electronic overload relay EF65, EF96 and EF146

Protection Equipment

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Synergy EN product information

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

MCD 200 Series Soft Starters

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

3VU13, 3VU16 Circuit-Breakers

Electronic timers CT-S range Function diagrams

Thermal overload relay TF65 and TF96

1.1 Caution Statements

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Thermal Overload Relays - WEG RW Series, 2 Pole

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Starting Torque Limiter Type TCI (Soft Start)

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

For Operation in the Control Cabinet 3RW Soft Starters

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

1 Phase electronic contactor (SC 1)

Siemens AG Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12 SIRIUS. Catalog Add-On IC 10 AO. Edition Answers for industry.

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Protective Devices: Circuit-Breakers 1 )

Protection Equipment. 5/2 Introduction

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Thermal overload relay TF140DU and TF140DU-V1000

Design Guide. VLT Soft Start Controller MCD 100

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Short form catalogue. Motor protection & control

RVS-AX Instruction Manual

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Star Series Motor protection & control

Motor Protection Circuit Breakers 3VU13 and 3VU16

Application example of a motor controlled by MCD100 and protected by a circuit breaker

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

MasterINTERFACE 39 Series - Relay interface modules

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

RVS-DN Digital Reduced Voltage Motor Starter

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Three-Phase Soft Starters

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Electronic timers CT-E range Selection and ordering details

Single & Three-Phase Soft Starters

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Technical Information

Bulletin 193-T1 Bimetallic Overload Relays

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

QUINT-PS/24DC/24DC/20

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

PSE The efficient range Description

Model Number Structure

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

CI-TI Contactors and motor starters Types CI 61 - CI 98

ASL09..S 3-pole Contactors - Spring Terminals

22AF 40AF AF 150AF 225AF 400AF 800AF

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Description. Positive safety relays

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Application Mini Contactors for Motors and Resistive Loads

Transcription:

Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated control supply ON 1) ma 440 200 660 360 Rated frequency Hz 5060 5060 Tolerance % 10 10 Control inputs IN ONOFF Rated operational ma Approx. 10 according to DIN 19240 Rated operational voltage V DC 24 from internal supply dc+ or external DC supply (according to DIN 19240) through terminals and IN Relay outputs Output 1 ONRUN mode 2) 1314 Operating indication Output 2 BYPASSED 2324 Bypass indication Output 3 OVERLOADFAILURE 959697 Overloaderror indication Rated operational A 3 AC-15AC-14 at 230 V Rated operational voltage 1 DC-13 at 24 V Protection against overvoltages Protection by means of varistor through contact Short-circuit protection 4 A glgg operational class; 6 A quick (fuse is not included in scope of supply) 1) Values for the coil power consumption at +10 % U n, 50 Hz. 2) Factory presetting: ON mode. Type.. Control electronics Operating indications LED DEVICE STATEBYPASSED FAILURE OVERLOAD Off Green Off Off Off Start Green Green flashing Off Off Bypass Green Green Off Off Ramp-down Green Green flashing Off Off Alarm signals I e class setting not permissible Off Not relevant Not relevant Red flashing Start inhibitedthyristors too hot Yellow flashing Not relevant Not relevant Off Error signals U < 0.75 x U s or U > 1.15 x U s Off Off Red Off Non-permissible I e Class setting for edge 0 > 1 on input IN Green Off Red Red flashing Motor protection shut-down Green Off Off Red Thermal overloading of the thyristors Yellow Off Red Off Missing mains voltage, phase failure, missing load Green Off Red Off Device fault Red Off Red Off Type.. Factory presetting Protection functions Motor protection functions Trips in the event of Thermal overloading of the motor Trip class to IEC 60947-4-1 Class 101520 10 Phase failure sensitivity % >40 Overload warning No Reset option after tripping Manualautomatic (MANAUTO) Recovery time min 5 Device protection functions Trips in the event of Thermal overloading of the thyristors Reset option after tripping Manualautomatic (MANAUTO) Recovery time s 30

Type.. Factory presetting Control times and parameters Control times Closing delay (with control voltage) ms <50 Closing delay (automaticmains contactor mode) ms <300 Recovery time (closing command in active ramp-down) ms 100 Mains failure bridging time Control supply voltage ms 50 Mains failure response time Load circuit ms 500 Reclosing lockout after overload trip Motor protection trip min 5 Device protection trip s 30 Starting parameters Starting time s 0...20 7 Starting voltage % 40... 100 50 Starting limit 1.3...5xI e 5xI e Ramp-down parameters Ramp-down time s 0...20 0 Reset mode parameters (for motordevice protection shut-down) Manual reset LED AUTO Off Off Automatic reset LED AUTO Yellow Start-up detection Yes Operating mode output 1314 Rising edge at Start command Falling edge at Off command ON ON Ramp-down end RUN Type..-.BB4...-.BB5. Power electronics Rated operational voltage for inline circuit VAC 200... 460 400... 600 Tolerance % -15+10-15+10 Rated frequency Hz 5060 Tolerance % 10 Continuous duty at 40 C (% of I e ) % 115 Minimum load (% of set motor I M ) % 15 Maximum cable length between soft starter and motor m 200 Permissible installation height m 5000 (derating from 1000, see characteristic curves); higher on request Permissible mounting position ' ' # # 5 * $ " ' Permissible ambient temperature Operation C -25... +60; (derating from +40) Storage C -40... +80 Degree of protection IP00

Type 55 56 73 74 75 76 Power electronics Load rating with rated operational I e According to IEC and ULCSA, for individual mounting, AC-53a -At 40 C A 134 162 230 280 356 432 -At 50 C A 117 145 205 248 315 385 -At 60 C A 100 125 180 215 280 335 Smallest adjustable rated motor I M For the motor overload protection A 59 87 80 130 131 207 Power loss In operation after completed starting with uninterrupted rated W 60 75 75 90 125 165 operational (40 C) approx. During starting with limit set to 350% I M (40 C) W 1043 1355 2448 3257 3277 3600 Permissible rated motor and starts per hour For normal starting (Class 10) - Rated motor I 1) M, starting time 10 s A 134 162 230 280 356 432 - Starts per hour 2) 1h 20 8 14 20 16 17 - Rated motor I 1)3) M, starting time 20 s A 134 162 230 280 356 432 - Starts per hour 2) 1h 7 1.4 3 8 5 5 For heavy starting (Class 15) - Rated motor I 1) M, starting time 15 s A 134 152 210 250 341 402 - Starts per hour 2) 1h 11 8 11 13 11 12 - Rated motor I 1)3) M, starting time 30 s A 134 152 210 250 341 402 - Starts per hour 2) 1h 1.2 1.7 1 6 2 2 For heavy starting (Class 20) - Rated motor I 1) M, starting time 20 s A 124 142 200 230 311 372 - Starts per hour 2) 1h 12 9 10 10 10 10 - Rated motor I 1)3) M, starting time 40 s A 124 142 200 230 311 372 - Starts per hour 2) 1h 2 2 1 5 1 1 1) Current limit on soft starter set to 350 % I M. 2) For intermittent duty S4 with ON period = 70 %, T u = 40 C, stand-alone installation vertical. The quoted switching frequencies do not apply for automatic mode. 3) Maximum adjustable rated motor I M, dependent on CLASS setting.

Soft starter Type 5. 7. Conductor cross-sections Main conductors: With box terminal 3RT19 55-4G (55 kw) 3RT19 66-4G Front clamping point Finely stranded with end sleeve mm 2 16... 70 70... 240 Finely stranded without end sleeve mm 2 16... 70 70... 240 Stranded mm 2 16... 70 95... 300 mm Min. 3 x 9 x 0.8 Max. 6 x 15.5 x 0.8 Min. 6 x 9 x 0.8 Max. 20 x 24 x 0.5 AWG conductors, solid or stranded AWG 6... 20 30... 600 kcmil Rear clamping point Finely stranded with end sleeve mm 2 16... 70 120... 185 Finely stranded without end sleeve mm 2 16... 70 120... 185 Stranded mm 2 16... 70 120... 240 mm Min. 3 x 9 x 0.8 Max. 6 x 15.5 x 0.8 Min. 6 x 9 x 0.8 Max. 20 x 24 x 0.5 AWG conductors, solid or stranded AWG 6... 20 250... 500 kcmil Both clamping points Finely stranded with end sleeve mm 2 Max. 1x50, 1x70 Min. 2 x 50; max. 2 x 185 Finely stranded without end sleeve mm 2 Max. 1x50, 1x70 Min. 2 x 50; max. 2 x 185 Stranded mm 2 Max. 2 x 70 Max. 2 x 70; max. 2 x 240 mm Max. 2 x (6 x 15.5 x 0.8) Max. 2 x (20 x 24 x 0.5) AWG conductors, solid or stranded AWG Max. 2 x 10 Min. 2x20; max.2x500kcmil Terminal screws M10 (hexagon socket, AF4) M12 (hexagon socket, AF5) - Tightening torque Nm 10... 12 20... 22 lb.in 90... 110 180... 195 Main conductors: With box terminal 3RT19 56-4G Front or rear clamping point Finely stranded with end sleeve mm 2 16... 120 Finely stranded without end sleeve mm 2 16... 120 Stranded mm 2 16... 120 mm Min.3x9x0.8 Max. 6 x 15.5 x 0.8 AWG conductors, solid or stranded AWG 6... 250 kcmil Both clamping points Finely stranded with end sleeve mm 2 Max. 1 x 95, 1 x 120 Finely stranded without end sleeve mm 2 Max. 1 x 95, 1 x 120 Stranded mm 2 Max. 2 x 120 mm Max. 2 x (10 x 15.5 x 0.8) AWG conductors, solid or stranded AWG Max. 2 x 30 Main conductors: Without box terminalrail connection Finely stranded with cable lug mm 2 16... 95 1) 50... 240 2) Stranded with cable lug mm 2 25... 120 1) 70... 240 2) AWG conductors, solid or stranded AWG 4... 250 kcmil 20... 500 kcmil Connecting bar (max. width) mm 17 25 Terminal screws M8 x 25 (AF13) M10 x 30 (AF17) - Tightening torque Nm 10... 14 14... 24 lb. in 89... 124 124... 210 1) When connecting cable lugs to DIN 46235, use 3RT19 56-4EA1 terminal cover for conductor cross-sections from 95 mm² to ensure phase spacing. 2) When connecting cable lugs to DIN 46234, the 3RT19 66-4EA1 terminal cover must be used for conductor cross-sections of 240 mm² and more as well as DIN 46235 for conductor cross-sections of 185 mm² and more to keep the phase clearance. Soft starter Type.. Conductor cross-sections Auxiliary conductors (1 or 2 conductors can be ): Solid mm 2 2 x 0.5... 2.5 Finely stranded with end sleeve mm 2 2 x 0.5... 1.5 AWG conductors - Solid or stranded AWG 2x20...14 - Finely stranded with end sleeve AWG 2x20...16 Terminal screws - Tightening torque Nm 0.8... 1.2 lb. in 7... 10.3 Spring-loaded terminals Solid mm 2 2 x 0.25... 1.5 Finely stranded with end sleeve mm 2 2 x 0.25... 1.5 AWG conductors, solid or stranded AWG 2x24...16

Standard Parameters Electromagnetic compatibility according to EN 60947-4-2 EMC interference immunity Electrostatic discharge (ESD) EN 61000-4-2 4 kv contact discharge, 8 kv air discharge Electromagnetic RF fields EN 61000-4-3 Frequency range: 80... 1000 MHz with 80 % at 1 khz Degree of severity 3: 10 Vm Conducted RF interference EN 61000-4-6 Frequency range: 150 khz... 80 MHz with 80 % at 1 khz Interference 10 V RF voltages and RF s on cables Burst EN 61000-4-4 2 kv5khz Surge EN 61000-4-5 1 kv line to line EMC interference emission EMC interference field strength EN 55011 Limit value of Class A at 30... 1000 MHz Radio interference voltage EN 55011 Limit value of Class A at 0.15... 30 MHz Is an RI suppression filter necessary? Degree of noise suppression A (industrial applications) No

Fuse assignment The type of coordination to which the motor feeder with soft starter is mounted depends on the application-specific requirements. Normally, fuseless mounting (combination of circuit breaker and soft starter) is sufficient. If type of coordination "2" is to be fulfilled, semiconductor fuses must be fitted in the motor feeder. Fuseless version 3! 5 * $ = Soft starters Circuit breakers 1) Rated 400 V +10 % 575 V +10 % Rated G1 Q1 Q1 Type A Type Type A Type of coordination "1" 2) : I q = 65 ka at 400 VI q = 35 ka at 600 V 3) 55 134 3VL3 720-2DC36 3VL3 720-1DC36 200 56 162 3VL3 720-2DC36 3VL3 720-1DC36 200 73 230 3VL4 731-2DC36 3VL5 731-3DC36 315 74 280 3VL4 731-2DC36 3VL5 731-3DC36 315 75 356 3VL4 740-2DC36 3VL5 740-3DC36 400 76 432 3VL5 750-2DC36 3VL5 750-3DC36 500 1) The rated motor must be considered when selecting the devices. 3) Except 55: I q = 35 ka at 400 VI q =12kA at 600V. 2) The types of coordination are explained in more detail under Fuseless Load Feeders on Page 651. Fused version (line protection only).! 5 * " % % = Soft starters Line protection, maximum Line contactors Rated Rated Size (optional) G1 F1 K1 Type A Type A Type 115 V Type 230 V Type of coordination "1" 1) : I q = 65 ka at 400600 V 55 134 3NA3 244-6 250 2 3RT10 55-6AF36 3RT10 55-6AP36 56 162 3NA3 244-6 250 2 3RT10 56-6AF36 3RT10 56-6AP36 73 230 2 x 3NA3 354-6 2x355 3 3RT10 65-6AF36 3RT10 65-6AP36 74 280 2 x 3NA3 354-6 2x355 3 3RT10 66-6AF36 3RT10 66-6AP36 75 356 2 x 3NA3 365-6 2x500 3 3RT10 75-6AF36 3RT10 75-6AP36 76 432 2 x 3NA3 365-6 2x500 3 3RT10 76-6AF36 3RT10 76-6AP36 1) The types of coordination are explained in more detail under Fuseless Load Feeders on Page 651.

Fused version with 3NE1 SITOR fuses (semiconductor and line protection).! 5 * " % & > Soft starters All-range fuses Line contactor Rated Rated Size (optional) G1 F 1 K1 Type A Type A Type 115 V Type 230 V Type of coordination "2" 1) : I q = 65 ka at 400600 V 55 134 3NE1 227-2 250 1 3RT10 55-6AF36 3RT10 55-6AP36 56 162 3NE1 227-2 250 1 3RT10 56-6AF36 3RT10 56-6AP36 73 230 3NE1 331-2 350 2 3RT10 65-6AF36 3RT10 65-6AP36 74 280 3NE1 333-2 450 2 3RT10 66-6AF36 3RT10 66-6AP36 75 356 3NE1 334-2 500 2 3RT10 75-6AF36 3RT10 75-6AP36 76 432 3NE1 435-2 560 3 3RT10 76-6AF36 3RT10 76-6AP36 1) The types of coordination are explained in more detail under Fuseless Load Feeders on Page 651. Fused version with 3NE3 SITOR fuses (semiconductor protection by fuse, line and overload protection by circuit breaker; alternatively, installation with contactor and overload relay possible).!. 3.!! 5 * ' =! 5 * " % ' = Soft starters Semiconductor fuses, minimum Semiconductor fuses, maximum Line contactor Rated Rated Size Rated Size (optional) G1 F3 F3 K1 Type A Type A Type A Type 115 V Type 230 V Type of coordination "2" 1) : I q = 65 ka at 400600 V 55 134 3NE3 227 250 1 3NE3 335 560 2 3RT10 55-6AF36 3RT10 55-6AP36 56 162 3NE3 227 250 1 3NE3 335 560 2 3RT10 56-6AF36 3RT10 56-6AP36 73 230 3NE3 232-0B 400 1 3NE3 333 450 2 3RT10 65-6AF36 3RT10 65-6AP36 74 280 3NE3 233 450 1 3NE3 336 630 2 3RT10 66-6AF36 3RT10 66-6AP36 75 356 3NE3 335 560 2 3NE3 336 630 2 3RT10 75-6AF36 3RT10 75-6AP36 76 432 3NE3 337-8 710 2 3NE3 340-8 900 2 3RT10 76-6AF36 3RT10 76-6AP36 Soft starters Circuit breakers Line protection, maximum Rated 400V +10% Rated 575 V +10 % Rated Rated Size G1 Q1 Q1 F1 Type A Type A Type A Type A Type of coordination "2" 1) : I q = 65 ka at 400600 V 55 134 3VL3 720-1DC36 200 3VL3 720-1DC36 200 3NA3 244-6 250 2 56 162 3VL3 720-1DC36 200 3VL3 720-1DC36 200 3NA3 244-6 250 2 73 230 3VL4 731-1DC36 315 3VL5 731-1DC36 315 2 x 3NA3 354-6 2 x 355 3 74 280 3VL4 731-1DC36 315 3VL5 731-1DC36 315 2 x 3NA3 354-6 2 x 355 3 75 356 3VL4 740-1DC36 400 3VL5 740-1DC36 400 2 x 3NA3 365-6 2 x 500 3 76 432 3VL5 750-1DC36 500 3VL5 750-1DC36 500 2 x 3NA3 365-6 2 x 500 3 1) The types of coordination are explained in more detail under Fuseless Load Feeders on Page 651.