DUAL DIGIT COUNTDOWN TIMER MANUAL

Similar documents
DKG-114 MANUAL AND REMOTE START UNIT

GCU-10. Automatic Engine Control Unit Operators Manual

Ezyfit AC Controller INSTRUCTION BOOK 2 & 4 STATION UNITS

User & Installation Guide. Version 1.4

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

GLM SERIES CONTROL Users Manual Rev:

Instruction Manual MINI IRRIGATION CONTROLLER.

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

EC200 ELECTRONIC CONTROL SYSTEM

ECONOMISER SERIES E2T USER MANUAL

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

MINIATURE CIRCUIT BREAKER

PFC W HF/PFC Battery Charger

IRRIGATION CONTROLLER

Melody 1 Platform Lift

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

Operating Instructions Control 330 Conductivity meter

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DIESEL Engine Fire Pump Controllers Features

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

INSTRUCTION AND USE MANUAL

Security alarms, warning systems.

Miniature Circuit Breaker

MCD Pump Application Module

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Technical Data FUEL CONTROL SYSTEM TANK GAUGE INTERFACE KIT. Applies to the following models only: - FC.TGE - FC.OCIO

EC328 Power Control System

Maxx 3 Installation Guide

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

Pressure Transmitters

8000 Series Liquid Flow Meter

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Gate & Door Controller with LCD and Intelligent Technology

CAUTION CM-SE CM-S21 CM-S41

Operating Instruction for Flowmonitor. Model: DF-WM

24V 3A EN54 Ancillary Power Supply

EC225 Power Control System

PART B BRAND SPECIFIC MANUAL

Elmdene International Ltd

Model 1900, 1901, 1902 Switching DC Power Supply

Installation Instructions: K-Safe-T-Drift

USER S MANUAL. Installation, Operation, & Maintenance

EC400 Power Control System

3000W HF/PFC Battery Charger

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

To ensure proper installation, digital pictures with contact information to before startup.

Three-Phase Soft Starters

SDS Enclosed Star-Delta Starter User Guide

SWITCHGEAR. 4G cam switches

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Application Engineering

Spares and Accessories

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Type SOQ Negative Sequence Time Overcurrent Relay

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Model 1900, 1901, 1902 Switching DC Power Supply

Signet Pressure Transmitter

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

E R A I Gate Openers Department

SCM-Power Distribution PLUS system Installation and User Instructions:

Flight Systems. Replacement for KASSEC DESCRIPTION

Cellwatch Battery Monitoring Systems

STR3. Step Motor Drive. User Manual

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

AEROSTAT HP-N-Ex Ionising Air Blower

Installation Instructions

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S


PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Sliding doors / fire doors

Single & Three-Phase Soft Starters

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Differential Temperature Controller

Installation Instructions for Lingenfelter Shift Light Controller with green LED

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

AFM500X Automatic Flashing Module

8000 Series Liquid Flow Meters

Magnetek DSD 412 Drive

Two Channel Remote Shutdown Device

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

CeraControl. Temperature Programmer User Handbook.

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

S D ST215 TAFFOR. ST215 Temperature Programmer User Handbook.

DKG-215 MANUAL AND REMOTE START UNIT

PSM72H Push-Button Start Module

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Transcription:

DUAL DIGIT COUNTDOWN TIMER MANUAL

2

3 Topline Electronics Ltd Introduction Topline were established in 1986 to provide high quality equipment. Topline now provide integrated dosing equipment packages with a comprehensive service backup. We believe that our after sales service is an integral part of the company s success, and wish to assure existing and new customers that we will continually review product and service performance with the aim of improving both. If you are experiencing any problems with your control system or general water quality, please do not hesitate to contact a Topline engineer on 01323-440760. Topline are always willing to develop new products and services with clients, so if you have an idea on how to improve any of Topline s products or wish to develop a product for your own use, please contact Andrew Hunt on 01323 440760. Technical Data Display Dimension Power Requirement Power Consumption Operating Temperature Enclosure Inputs Display Technical Data Control Dimension Power Requirement Power Consumption Operating Temperature Enclosure Outputs 122mm wide * 122mm high * 50mm tall. 12 VDC. 0.5amps. 0-50 degrees centigrade. Plastic IP65 4 wire from control unit. Bi Colour 38mm LED 122mm wide * 122mm high * 50mm tall. 240v ac 50 Hz Single phase 6 amps. 0-50 degrees centigrade. Plastic IP65 4 wire to display unit

4 CE Certificate Declaration of conformance Manufacturer's Name Topline Electronics Ltd Manufacturer's Address A8 Ropemaker Park Hailsham, E.Sussex England, BN27 3GU Declares that the above product conforms to the following product specifications: Low Voltage Directive 72/73 EEC Electromagnetic Compatibility Directive 2004/108/EC Restriction of Hazardous Substances (RoSH) Directive 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) Directive 2002/95/EC CE marking. I the undersigned, declare that the equipment above conforms to the above directives and carries the CE marking. Manufacturer Topline Electronics Ltd Signature on behalf of Topline Electronics Ltd A.Hunt Date Feb.10th 2007 Health and Safety Warning This equipment controls the operation of the feature pumps. If the incorrect on period is set then chemical control of the water can be difficult. Remember, if something is wrong with any of the swimming pool systems, TAKE THE APPROPRIATE ACTION! Even if this is only to alert your manager. Do not just record a fault and walk away - bad pool management can affect bathers health. Risk Assessment If the equipment is not operated by persons who are not proficient in the operation of swimming pool plant, then there is a risk of: 1. Operation of the receiver with covers removed may result in electrocution.

5 Installation. The Spa count down timer comes as two separate boxes. One of which is a dual digit LED display, the other is the control unit. Access to the mounting holes is by removing the screws that hold the lid in place. All cables must be routed using 20mm conduit fittings. The 4-core burglar cable can be up to 500 meters in length. The mains supply must be fitted with a 3 or 6 amp miniature circuit breaker. The blower trigger is a volts free relay output that MUST operate a SEPARATE contactor that supplies power to the blower. This relay can switch 240vAC at 1 amp maximum or it can be used to switch 24v AC or DC at 2 amp maximum. On NO account can this relay switch mains directly to the blower. The control unit can be triggered by a mains voltage or by a low voltage. It is recommended that the low voltage trigger be used on new installations. The low voltage input can be triggered by connecting the trigger input either to GND or to +24v. The quiescent condition being a disconnection. The control unit can be programmed to various on and off times. See the section entitled Changing the blower on and off times. Testing the control unit is a simple matter of applying power and checking that the Power on self test procedure on the display end is performed completely. This is followed by two green zeros (00) and a flashing decimal point to indicate that the unit is idle and ready. Press the puffer switch and the air blower should start.

6 Connections Dual digit display in pool room A B GND +12v 4-Core burglar alarm cable. Yellow - A Blue - B Black - GND Red - +12v Control unit in plant room A B GND +12v +12v GND Remote display Mains Supply L N E Blower Trigger Gnd Low voltage trigger input 3A or 6A MCB To air blower contactor Puffer switch

7 Dual Digit Spa Count Down Timer. Purpose. The unit is designed to allow a Spa feature to run for a preset time when triggered by a switch and then to prevent the feature from being run again for a preset resting time. Operation. The seven segment display has four operating modes. Power on self test, idle time, run time and disable time. Power on self test. The display will cycle through a self test when power is first applied. This consists of displaying two red dashes (--) followed by two red sixes (66) with a decimal point. The display will then count up as follows: green 00-09, red 00-09, green 00-90, red 00-90. Idle time. Two green zeros (00) and a flashing decimal point indicate that the unit is idle and ready for the user to turn the air blower on using the puffer switch. Run time. When the puffer switch is pressed the air blower is operated and the display will show the duration time in minutes in green that the air blower will run for. Disable time. When the air blower has completed its run cycle it will be turned off and disabled. The display will show the duration in minutes in red that the blower is disabled for.

8 Changing the blower on and off times. The on and off durations can be altered by the rotary switches located in the control unit in the plant room. WARNING :- DISCONNECT THE MAINS POWER WHEN WORKING INSIDE THE CONTROL UNIT. Unscrew the four screws in the box corners. Inside there will be a set of rotary switches with red and green knobs on. There are three types, one with just one red and one green knob, one with two red and two green knobs and the other with two grey knobs.. The switches have a click style feel to them. If not then the switch is faulty because the cut out has been sandwiched between two numbers. It is important for the notch on the switches to clearly show only one number. Use a small screwdriver to rotate the knob to the required position. Units with two red and two green knobs. The red knob sets the blower disable time. The green knob sets the blower run time. Both times are measured in minutes. These switches have ten positions. 0-9. The time shown on the switches corresponds directly to the run time and disable time with the caveat that 00 is forced to become 1 minute. Units with one red and one green knob. These single switches have sixteen positions. 0-9 and A - F. Switch Blower Blower position run time rest time 0 5 mins 2 mins 1 6 3 2 7 4 3 8 5 4 9 6 5 10 7 6 11 8 7 12 9 8 13 10 9 14 11 A 15 12 B 16 13 C 17 14 D 18 15 E 19 16 F 20 17

9 Changing the blower on and off times continued. Units with two grey knobs. These single switches have ten positions. 0-9. SW1 controls the blower running time. SW2 controls the blower rest time. Switch Blower Blower position run time rest time 0 6 mins 2 mins 1 8 3 2 10 4 3 12 5 4 14 6 5 16 7 6 18 8 7 20 9 8 22 10 9 24 11