AirPort MD8 Battery-Power, Portable Air Sampler

Similar documents
Environmental Monitoring Microbial Air Sampling RCS High Flow Touch

Heating oven with mechanical control

Refrigerated incubator with Peltier technology

Heating oven with natural convection

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Modular Filtration Manifolds and Related Assembly Components Specialized Manifold Producer

Heating chamber with mechanical convection

Heating chamber with mechanical convection

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

Safety drying ovens. Advantages: Areas of application: FDL series 115

FlowFAST H. Horizontal Laminar Flow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Heating oven with mechanical convection

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Boekel Complete Culture Control Incubators

3. Operating instructions: Minor 200

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Vari-Disk Service. Inline disc filters to meet your needs. Inlet and outlet connectors. Filter housing

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Flash Point Process Analyzer

SITRANS P measuring instruments for pressure

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :

Portable pressure calibrator, Wally Box III Model CPH7600

Integrated temperature test and calibration bench Model CBS-SC4000

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

MCP Standard. Multi-purpose Saves individual application parameters! Applications. Interfaces. Robust, powerful drive Ideal for dispensing and filling

Pipette Controllers OPERATOR INSTRUCTIONS

Insertion magnetic inductive flowmeter

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

Mobile Filter Unit MFU-15

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Drying ovens. FD 53 - Drying oven with forced convection. Performance features and equipment :

Operating Instructions AirLite Sample Pump Cat. No SKC Inc. 863 Valley View Road Eighty Four, PA 15330

TECHINCAL DESCRIPTION BIO BAN

Millipore Express SHR Hydrophilic Filters

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

JUMO MIDAS S05 Pressure transmitter Type

Process Filtration From Pure to Sterile

Process Filtration From Pure to Sterile

Technical Information Liquiline System CAT810

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

Dräger X-am Mark II Pump External pump for multi-gas detectors

EN. SKF Grease Spraying System For Large Open Gears. Extend the lifetime of large gear drives

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

LowViscosity Housing Filter LVH-F

Process Filtration From Pure to Sterile

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

POLYMED CATALOGUE 2013 POLYCARBONATE STOPCOCKS MANIFOLDS - CONNECTORS

Automatic back-flushing filter AutoFilt RF4

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

Climate chamber with illumination

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

Ductless mobile fume hoods with modular filtration column

Produce it at a lower cost! TKA Ion exchangers!

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Climate chambers with illumination

SPUN (MELT-BLOWN) POLYPROPYLENE MICRON FILTER CARTRIDGE

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Battery compartment door. Belt clip (back of pump) Front view Top view. Figure 1. AirLite Sample Pump

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

FLUID TRANSFER SECTION 1

Flow measurement FlexFlow PF20H Hygienic flow sensor

Model ED 400 Drying and heating chambers Classic.Line with natural convection

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Isolator technology. eco safe Iso Compact. Width (m) EN Isolator. Class. Standard 0.9 / 1.2 II EN

» Features. » Applications. Product Range Flow Sensors. Thermal Anemometer No moving parts Immersion probe Transformer integrated

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Solutions for sterile Requirements

Compact Pressure Transmitter DAN-HH

V-SENSOR LOW AIR VELOCITY SENSOR

Magnetic-Inductive flow Meter fmi

Process Filtration From Pure to Sterile

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

SITRANS T measuring instruments for temperature

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

2/2-Way and T Valve Bodies in Stainless Steel

Incubators. Incubators

Thermo-hygrometer-anemometer VT 210

General Specifications

Certificate: _01 / 29 April 2014

better measurement Simply a question of

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Backflushing Filter AutoFilt RF4

Dissolved Oxygen Measurement System with Air Blast Cleaner

P-SRF V STERILE AIR PLEATED DEPTH FILTER ELEMENTS

Process Filtration From Pure to Sterile

PERSONAL AIR SAMPLER & RADIATION ALARM

Simply a question of better measurement

Transcription:

AirPort MD8 Battery-Power, Portable Air Sampler AirPort MD8 is the new air sampler for the pharmaceutical industry, the biotechnology, the food and beverage industry, for hospitals environmental care and for works safety. AirPort MD8 uses the gelatine membrane filter method guaranteeing reliable and exact measurement results. AirPort MD8 offers following benefits: Battery-powered and portable for universal use. Battery-control guarantees constant performance during the air sampling. Ergonomic design and easy to clean. Flexible adjustment possibilities of the volume flow and the sample volume. The device can be calibrated locally. Airport Specifications for AirPort MD8 Volume flow regulation by integrated anemometer. Volume flow adjustable in three steps Fixed given sample volumes Operational life with one battery charge Noise level Dimensions (L + W + H) Power supply Battery Battery charger input Battery charger output Charging time 30 l/min., 40 l/min and 50 l/min. 25, 50, 100, 250, 500, 750 and 1000 liters. In addition, the sample volume can be chosen manually in 5-liter steps. Approx. 4.5 hours For gelatine membrane filters 48 db (A) Approx. 2.5 kg 300 + 135 + 165 mm NiMH 16.8 Volt/3800 mah 100 240 V/47 63 Hz/600 ma 24 V/1000 ma Approx. 4.5 hours for empty battery Order information for AirPort MD8 16757 AirPort MD8, complete with holder (17801) for gelatine disposable units and battery charger (6989525). Accessories for AirPort MD8 17801 Adapter for disposable gelatine filter units. 6989525 Battery charger. Order information for consumables Disposable gelatine units, sterile, pack of 10 17528-080 ACD Individually packed in 1 Polyethylene bag each 17528-080 BZD Individually packed in 3 Polyethylene bags each 17528-080 VPD Individually packed in 3 Polyethylene bags each, but label on innermost bag Further accessories and consumables on request! Special brochure available on request. Order no. SM-1502-e 172

The Detection of Microorganisms and Viruses out of Air Quantitatively and Reproducible with the MD8 airscan The system consists of the MD8 airscan air sampler and disposable gelatine filter units. The system is routinely used for the quantitative detection of air-borne organisms, mainly in sterile areas of class A and B (classification according to EU-Guide for GMP ), isolators, or blow-fill-seal machines. The very high air flow rate of 8 m 3 /h enables isokinetic sample removal at flow speed usual in laminar flow as well as for the filtration of 1 m 3 air very quickly (less than 8 minutes). The filter unit can be placed remote from the air sampler. The MD8 airscan air sampler allows to adjust selectively and easily air flow rate and sample removal speed. By means of a specially developed calibration unit (see accessories) the user can calibrate the MD8 airscan locally, e.g. within the scope of validation steps. After removing the sample, the gelatine filter can be placed directly on the agar culture medium for incubation and colony growth. Specifications for the MD8 airscan air sampler Air flow rate 2.0 m 3 /h 8 m 3 /h adjustable in 100 liter steps Timer 1 99 minutes, adjustable in 1 minute steps Max. deviation ±5% in a temperature range of 15 35 C Noise level For gelatine membrane filters, max. 62 db (A) Approx. 6.5 kg Dimensions (L + W + H) 375 + 242 + 228 mm Correction of the When the entered air flow rate cannot be attained, air flow rate setting the display shows the max. attainable flow rate for a corresponding new setting below this value. Specifications for gelatine filters Gelatine filter Water-soluble, pore size 3 µm. Diameter 80 mm. Thickness approx. 250 µm. Max. temperature 60 C. Residual dampness content 46% 49%. Air flow rates approx. 2.7/min./cm 2 at p = 0.05 bar. Retention rates 1. Bac. subtilis niger 99.9995% at 0.25 m/s inlet velocity 2. Coli-Phages: phage T1, 99.9% at 0.3 m/s inlet velocity and 50% rel. air humidity. Phage T3, 99.94% at 0.3 m/s inlet velocity and 80% rel. air humidity Filtration area 38.5 cm 2 Conditions for use Room temperature, max. 30 C, max. air humidity 85% Sterilization Supplied presterilized by gamma irradiation Airscan, Gelatine Membranes 173

Order information for the MD8 airscan air sampler 16746 MD8 airscan air sampler, 230 V, 50 Hz 16747 MD8 airscan air sampler, 115 V, 60 Hz 16748 MD8 airscan air sampler, 100 V, 50 60 Hz Each version can be switched from 50 to 60 Hz and back. Accessories for the MD8 airscan air sampler 17801 Holder for disposable gelatine filter units Order information for consumables Disposable gelatine units, sterile, pack of 10 17528-080 ACD Individually packed in 1 Polyethylene bag each 17528-080 BZD Individually packed in 3 Polyethylene bags each 17528-080 VPD Individually packed in 3 Polyethylene bags each, but label on innermost bag Airscan, Gelatine Membranes Further consumables on request! Special brochures available on request. Order no. SLF3001-e SM-3011-e 174

Accessories for the MD8 Air Samplers Calibration unit The user himself can calibrate the MD 8 airscan and AirPort MD8 directly on the job by means of the calibration unit*. This is absolutely necessary above all within the scope of validation steps, for which it is important, that the shown air flow rate (desired value at the MD8) corresponds to the actual air amount (actual value at the calibration device). On request, a calibration certificate of the German Calibration Service can be made available. The calibration unit is supplied complete with battery charger power supply unit (specific for the country in which it is used), filter holder, connectors set and connection tube (PVC, 2m). Tubing and connectors set If the disposable gelatine filter unit is not placed directly at the MD8 airscan, but in a distance from it, a flexible plastic hose (2 m or 5 m), a connectors set and, if not available, a holder (tripod 16970, double socket 16976, clamp 17037) are necessary for the connection between filter and MD8 airscan. The autoclavable silicone hose is used instead of the flexible plastic hose, if the MD 8 airscan has to be used in sterile rooms, operating rooms, isolators, blow-fill-seal machines, etc. With this hose attached to the air outlet connector (exhaust), the waste air can be led off into an other room. Case Stable case for the transport and the storage of a MD 8 airscan incl. accessories. Gelatine membrane filter, 80 mm, sterile, pack of 50 Gelatine membrane filters are still available as 80 mm filter discs, suitable for the filter holder supplied with the MD8 airscan. The filters are sterile supplied, but the filter holders have to be sterilized by dry heat (180 C, 2 h) and then equipped with the filters under sterile conditions. For performing routine check-ups, a stack is recommended in this case. Aluminium stack It consists of a middle part, 10 numbered filter holders and 2 end caps. The stack is first sterilized (by 180 C dry heat, 2 h), and then equipped with the filters under sterile conditions (LF-cleanbench). The prepared filter holders are put on a side of the middle part. After removing the sample, the inserted filter holders are put on the other side of the middle part, so that used and not-used filter holders are separated from each other. Accessories Specifications for calibration unit Dimensions Length without filter holder, 295 mm Width, 174 mm Height with handling, 246 mm Connectors Quick locks (bayonet principle) Operational life with full battery Approx. 70 hours Approx. 5.6 kg Charge time for empty battery Approx. 30 hours Max. fault To 3.2 m 3 /h, ±3% Max. fault 3.2 to 16 m 3 /h, ±1.5% Measuring range 1.6 16 m 3 /h Type of protection IP 40 Ambient conditions Rel. air humidity, 30% 80% Temperature, min. 10 C, max. 40 C * Alternatively, a maintenance agreement can be signed. Within the scope of the contractual services, Sartorius technicians will carry out a calibration of the MD8 at regular intervals. 175

Order numbers 16740 Calibration unit 17208 Case 12602-080 ALK Gelatine membrane filter, 80 mm, sterile, pack of 50 17656 Aluminium stack Tubing and connectors set 17085 Plastic hose, 2 m 17088 Plastic hose, 5 m 17662 Silicone hose, 1 m (25 + 3 mm) 17657 Connectors set Replacement parts for the stack 17655 Individual filter holders 17660 Middle part 17661 End cap Accessories 176