RedBin-P Pressure switches 5 Pa Pa

Similar documents
ExBin-P Pressure switches 5 Pa Pa

InBin-P Pressure switches 5 Pa Pa

RedCos-P Pressure sensor 20 Pa Pa

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

SCHISCHEK REDBIN-D TRANSMITTER

RVP-R- VAV controller. In explosion-proof version

m WARNING! READ m BEFORE INSTALLATION

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Type Z & Ex pz purge and pressurization system

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Type 2REX-A. Oil & Gas / Heavy Industry

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Assembly. Trunk IN + - S U, I U, I. Spur 1

Differential pressure sensor

Solenoid coil for control in potentially explosive areas Type BZ

Pressure Switches. Pressure switches, pneumatic. Pressure switches, electronic

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

JUMO dtrans p20 DELTA

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Temperature sensor TE2

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Technical Data. Dimensions

BETA SWITCHES FOR HAZARDOUS AREA

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Pressure Transmitter

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

CombiTemp Temperature Measuring System

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

SITRANS P measuring instruments for pressure

Pressure transmitter JUMO dtrans p02

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Resistance thermometer Without thermowell Model TR10-H

A good connection. International approvals.

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features. Display

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Compact differential pressure switch Models DC, DCC

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Thermocouple For additional thermowell Model TC10-B

Load and Motor Switches, Load-Break Switches Series 8549

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Load and Motor Switches, Load-Break Switches Series 8544

Compact temperature switch Model TCS

SATRON VVFe Pressure Transmitter

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

INTERNATIONAL METAL ENGINEERING

IECEx Certificate of Conformity

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

TORRIX Magnetostrictive level sensor

Pressure transmitter for industrial applications Type MBS 4510

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Leading the way in hazardous areas Features EATON

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Direct Communication Module

Type Electronic Limit Switch

Direct-acting 3/2 way plunger valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Series 3730 Electropneumatic Positioner Type

Safety Instructions Proline Promass 300

SATRON VT Pressure Transmitter

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Solenoid Valve Island Type 3965

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Differential Pressure Sensors

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

CSD Series Current Devices Split Core

Centrifugal fan with highly efficient EC drive motor

Compact pressure switch Model PCS

Sensor boxes SRBE Key features and product range overview

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Capanivo Series CN 4000

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Transcription:

RedBin-P Pressure switches 5 Pa... 5.000 Pa Electrical, explosion-proof binary pressure / differential pressure switches 5 Pa...100 Pa with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact EC type-approved in acc. with ATEX directive 2014 / 34 / EU for zone 2, 22 Compact. Easy installation. Universal. Cost effective. Safe. RedBin - P-... RedBin - P-... - 2 RedBin -... - CT RedBin -... - OCT RedBin -... - VA RedBin -... - OVA Subject to change! Type Switch Supply Range min. Setting max. Pressure Activation delay Output switch Wiring diagram RedBin- P- 100 Pressure 24 VAC / DC 0... 100 Pa 5 Pa 5.000 Pa 0...240 s potential free contact SB 1.0 RedBin- P- 500 Pressure 24 VAC / DC 0... 500 Pa 25 Pa 5.000 Pa potential free contact SB 1.0 RedBin- P-5000 Pressure 24 VAC / DC 0...5.000 Pa 250 Pa 50.000 Pa potential free contact SB 1.0 RedBin- P-... - 2 Types...P-500 und...p-5000 as above with additional switching 2 potential free contact SB 1.0 RedBin- P-... - CT Types as above with aluminium housing and seawater resistant coating (cable glands M16 brass nickel-plated, screws in stainless steel) RedBin- P-... - OCT Types as above, offshore version with aluminium housing and seawater resistant coating (stainless steel tubes for clamping ring connection, cable glands M20 brass nickel-plated, screws in stainless steel) RedBin- P-... - VA Types as above with stainless steel housing for aggressive ambient (cable glands M20 brass nickel-plated, screws in stainless steel) RedBin- P-... - OVA Types as above, offshore version with stainless steel housing for aggressive ambient (tubes for clamping ring connection and screws in stainless steel, cable glands M20 brass nickel-plated) Product views and applications Figures...Bin-P-...-2 Pressure / Diff. press. switch...bin-p...-ct...bin-p...-va Offshore...-OCT Offshore...-OVA Description The RedBin-P-... pressure switch generation from 5...5000 Pa (acc. to type) is a revolution for differential pressure switches in HVAC systems, in chemical, pharmaceutical, industrial and offshore /onshore plants, for use in hazardous areas zone 2 (gas) and zone 22 (dust). Highest protection class (ATEX) and IP66 protection, small dimensions, universal functions and technical data guarantee safe operation even under difficult environmental conditions. All pressure switches are programmable on site without any additional tools. The switching points are scalable within the maximum ranges. The integrated display is for parametrisation and an actual value indication at working mode (can be switched off as needed)....bin-p-...-2 switches are equipped with an additional switching (2-stage), which can be parametrised independently....bin-p-...-oct and...-ova offshore versions are equipped with stainless steel tubing Ø 6 mm. Highlights For all types of gases, mists, vapours and dust for use in zone 2 and 22 Power supply 24 VAC / DC Potential free switching contact Adjustable switching threshold, hysteresis and start-up bypass time Adjustable switch activation delay (acc. to type) Integrated Ex terminal box No addional Ex-i module requi No intrinsically safe wiring / installation between panel and sensor requi No intrinsically safe wiring / installation and no space in the panel requi Optional second switching (acc. to type) Display with backlight, can be switched off Password locking Down to 20 C ambient temperature applicable Compact design and small dimension Robust aluminium housing (optional with seawater resistant coating) or in stainless steel IP66 protection Offshore versions with pressure tube connection for clamping ring Ø 6 mm 1 / 6

Technical data...-p-100...-p-500...-p-5000 Supply voltage, frequency 24 VAC / DC ± 20 % (19,2...28,8 VAC / DC), 50 / 60 Hz Current, power consumption 150 ma, ~ 4 W, internal fuse 500 mat, without bracket, not removable Galvanic isolation Supply for relay min. 1,5 kv Electrical connection Terminals 0,14...2,5 mm² at integrated Ex terminal box, stripping length 9 mm, torque 0,4...0,5 Nm, equipotential bonding 4 mm² Cable glands 2 M16 1,5 mm, Ex approved, for cable diameter ~ Ø 5...9 mm Cable glands...-ct 2 M16 1,5 mm, Ex approved, brass nickel-plated, for cable diameter ~ Ø 6...10 mm...-va,...-oct,...-ova 2 M20 1,5 mm, Ex approved, brass nickel-plated, for cable diameter ~ Ø 6...13 mm Protection class Class I (grounded) Display LC-Display, backlit, for configuration, user guidance, parameter and actual value indication. Status indicator via LEDs Control elements 3 buttons for configuration Housing material Aluminium die-cast housing, coated. Optional with seawater resistant coating (...-CT/...-OCT) or stainless steel housing, 1.4581 / UNS-J92900 / similar AISI 316Nb (...-VA /...-OVA) Dimensions (L W H) Aluminium housing ~ 180 107 66 mm, stainless steel housing ~ 195 127 70 mm (each without connectors) Weight ~ 950 g aluminium housing, stainless steel version ~ 2,5 kg Ambient temperature 20...+50 C, storage temperature 35...+70 C Temperature class Aluminium housing T6 (T80 C) at 20...+50 C Stainless steel housing T5 (T95 C) at 20...+40 C, T4 (T130 C) at 20...+50 C Ambient humidity 0...95 % rh, non condensing Sensor circuit Internal intrinsically safe (IS) circuit Sensor Piezo pressure transmitter, installation in Ex zone Pressure connection P+ / P sleeves Ø 4...6 mm. OCT versions have 2 stainless steel (316L) tube connections for clamp ring fittings Ø 6 mm Measuring range 0...100 Pa 0...500 Pa 0...5000 Pa Minimum measuring range is 5 % of full range (e. g. 25 Pa at...500 Pa switch) Response time of sensor T90 / 5 s Accuracy of pressure < ± 1 % typically, max. ± 5 % of end value ± 1 Pa Setting range hysteresis 0,1...10 Pa (factory setting 2 Pa) 0,5...50 Pa (factory setting 10 Pa) 5...500 Pa (factory setting 100 Pa) Start delay 5 s Start-up bypass time (AUB) 3...240 s (factory setting 120 s) Switch activation delay 0...240 s (factory setting 0 s / Off) Setting zero point Via menu. Short-circuit mechanically both tube connectors P+ / P for the moment of zero point setting Output Potential free switching contact breaking /making contact, adjustable per menu max. rating load: 0,5 A (30 VAC/DC) 0,1 A (250 VAC) 0,1 A (220 VDC); min. rating load: 10 mw / 0,1 V / 1 ma Additional relay (type...-2) as above as above Duration of life Mechanical 10 10 6 Electrical (rated load) 100 10 3 Wiring diagram SB 1.0 Scope of delivery Pressure switch, 3 self-tapping screws 4,2 13 mm resp. in stainless steel (with...ct and...va versions), short circuit tube Special solutions and accessories...-ct...-oct...-va...-ova Types in aluminium housing with seawater resistant coating, parts nickel-plated Offshore version in aluminium housing with seawater resistant coating, parts nickel-plated Types in stainless steel housing, parts nickel-plated Offshore version in stainless steel housing, parts nickel-plated MKR Mounting bracket for round ducts up to Ø 600 mm Kit 2 Flexible pressure tube, 2 m, inner Ø 6 mm, 2 connection nipples Kit-S8-CBR 2 cable glands M16 1.5 mm, Ex-e, brass nickel-plated, for cable Ø 5...10 mm Kit-Offs-GL-CBR 2 cable glands M20 1.5 mm, Ex-d, Ms-Ni, for armou cables Kit-PTC-CBR 2 connecting tubes for tube fittings Ø 6 mm, stainless steel 316 L CSA Hazardous Location EMPLACEMENTS DANGEREUX This equipment is suitable for installation in Class I, Division 2,! Group A, B, C, D hazardous locations or nonhazardous locations only. CET ÉQUIPEMENT EST SEULEMENT APPROPRIÉ À L INSTALLATION DANS LA CLASSE I, DIVISION 2, GROUPES A, B, C, D DES EMPLACEMENTS DANGEREUX OU DES EMPLACEMENTS NON DANGEREUX. WARNING EXPLOSION HAZARD:! Substitution of components may impair suitability for Class I, Division 2. AVERTISSEMENT RISQUE D EXPLOSION : LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CE MATERIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I, DIVISION 2.! WARNING EXPLOSION HAZARD: Do not connect or disconnect this equipment unless power has been removed or the area is known to be nonhazardous. AVERTISSEMENT RISQUE D EXPLOSION : NE PAS BRACHER OU DÉBRANCHER TANT QUE LE CIRCUIT EST SOUS TENSION, À MOINS QU IL NE S AGISSE D UN EMPLACEMENT NON DANGEREUX. 2 / 6

Electrical connection All pressure switches require a 24 VAC / DC power supply. The electrical wiring must be realized via the integrated Ex terminal box acc. to ATEX. Attention: Before opening the terminal box cover, the supply voltage must be shut off! The supply has to be connected at terminals 1 ( / ~) and 2 (+ / ~). The start-up bypass delay (AUB) can be activated by bridging terminals 2 3. Activation is indicated by a flashing LED. Display, buttons and parameters Display for programming and indication Push button ENTER! the cable installation must be conside! RedBin-P-... SB 1.0 24 VAC / DC + ~ ~ PE AUB 1 2 3 Zero point compensation Approbations At different relay and supply voltages (24 VAC / DC) (see Information for Installation )! Relais 250 VAC / 0,1 A 220 VDC / 0,1 A 30 VAC / DC / 0,5 A 5 6 7 SW- IN (GND) SW- Ch 1 SW- Ch2 PA Switching function ly open or closed can be selected via menu only....bin-p-... pressure switches are equipped with a zero point compensation to adjust the module to the installation position. The pressure nipples P+ / P must be connected with a short circuit tube and the zero point compensation performed by following the menu for parametrisation (menu 14). Before starting the zero point compensation, the device should be connected to power supply for a minimum of 15 minutes to reach the uniform working temperature! ATEX directive 2014 / 34 / EU EC type-approved EPS 14 ATEX 1 658 IECEx certified IECEx EPS 14.0075 Approval for gas II 3 (1) G Ex nc [ia Ga] IIC T6...T4 Gc Types...-CT,...-OCT II 3 (1) G Ex nc [ia Ga] IIB T6 Gc Approval for dust II 3 (1) D Ex tc [ia Da] IIIC T80 C...T130 C Dc IP66 B. Long cabling CE identification CE 0158 We recommend using shielded signal wires and to connect one end of the shield to the EMC directive 2014 / 30 / EU...Bin-... terminal box. Enclosure protection IP66 in acc. with EN 60529 C. Separate ground wires For supply and signal wires use separate grounds. EAC TC RU С-DE.ГБ08.В.01510 D. Relais CSA 13.2672226 Aluminium housing Wires for safety extra-low voltage must be installed separately from other circuits. At 24 VAC / DC only supply and signal wires are permitted in one cable, in all other cases Class Division Class I, Division 2, Groups ABCD, T6, IP66 use separate or double isolated cables. An over-current protection fuse < 10 A has to Ex na IIC Gc be provided by the installer. Types...-CT,...OCT Ex na IIB Gc Class Zone Class I, Zone 2, AEx na IIC T6 Gc, IP66 Types...-CT,...OCT Class I, Zone 2, AEx na IIB T6 Gc, IP66 Important information for installation and operation! Fig....Bin-P-2 Push button for level selection Change operation parametrisation mode To change from operation to parametrisation mode and vice versa, push ENTER button for minimum of 3 seconds. Back to operation mode with menu save. Indication of data logging A flashing unit symbol (star) in the display shows that data is received and the device is working. Password input The default / delivery setup is 0000. In this configuration the password input is not activated. To activate the password protection (menu 15) change the 4 digits into your choosen numbers (e. g. 1234) and press ENTER. Please keep your password in mind for next parameter change! Due to a new parameter setup the password is requested. A. Installation, commissioning, maintenance All national and international standards, rules and regulations must be complied with. Certified apparatus must be installed in accordance with manufacturer instructions. If the equipment is used in a manner not specified by the manufacturer, the safety protection provided by the equipment may be impai. For electrical installations design, selection and erection, EN /IEC 60079-14 can be used. Canada: Install per Canadian Electrical Code (CEC). USA: Install per National Electrical Code (NEC). Attention: Apply all Ex rules and regulation before opening the internal terminal box. Do not open cover when circuits are live! Draw the wiring cables through the cable glands. For connection use the internal Ex terminal box and connect equipotential bonding. After connection install the cables in a fixed position and protect them against mechanical and thermical damage. Close all openings and ensure IP protection (min. IP66). Avoid temperature transfer and ensure not to exceed max. ambient temperature! For outdoor installation a protective shield against sun, rain and snow should be applied. After mounting and installation a zero point compensation must be done to ensure correct measurement results (see description). Sensors are maintenance free. An annual inspection is recommended. For electrical installations inspection and maintenance, EN / IEC 60079-17 can be used. Clean with damp cloth only. Ex sensors must not be opened and repai by the end user. 3 / 6

Dimensions [ mm ] Aluminium housing...bin-p...-oct Ø 4,5 68 80 107 181.7 2 4.5 Ø 4.5 182.7 102 59 123.3 ~ 194 ~ 226 21.5 213 157,5 166 ~ 180 170 117 138 Ø 4,5 Ø 4,5 66 55 Stainless steel housing...bin-p...-ova 69 81.3 126.3 ~ 61 70 Parametrisation and commissioning To change from operation to parametrisation mode push the ENTER button for minimum 3 seconds. If password protected: type password and push. Skip menu with, back to operation mode with menu save. Operation Parametrisation push for min. 3 s Menu Function ENTER Indication Select ENTER Next indication Select ENTER Next menu Menu 1 Preset Select application Menu 2 Unit sensor Select physical unit Menu 3 set 1 Select switching point 1 Menu 4 set 2 * Select switching point 2 Menu 5 hysteresis ** Select hysteresis Menu 6 mode ** Select switching properties (break contact, make contact) Menu 7 no function menu skip FAN, FILT, PRO Pa, mbar, inh 2 O enter setpoint enter setpoint enter hysteresis Up, Down, Mid * nc, no Continue next page 4 / 6

Continue Parametrisation Menu Function ENTER Indication Select ENTER Next indication Select ENTER Next menu Menu 8 no function menu skip Menu 9 no function menu skip Menu 10 no function menu skip Menu 11 no function menu skip Menu 12 Menu 13 Menu 14 Menu 15 time Select bypass (AUB) time display setting Select display Zero point compensation Sensor s calibration for its installation position security Select password protection Menu 16 save Select: save data, discard, back to menu, factory setting * for...bin-p-...-2 only (2-stage) ** adjustable in professional mode only (menu 1) enter seconds for AUB on, off enter password Yes, no, menu, dset (default setting) (operation mode after save ) Menu 1 pset Preset For some applications you can select presetting to ease parametrisation. Besides fan belt ( FAN ) and filter monitoring ( FILT ) the professional mode ( PRO ) is available for further applications. Professional mode When this mode is selected the switching properties can be set at will per menu 5 ( hysteresis ) and 6 ( mode ) acc. to requirements. Fan speed monitoring The preset FAN hides menu 5 ( hysteresis ) and 6 ( mode ) during parametrisation. The corresponding values are set automaticly. Filter monitoring The preset FILT hides menu 5 ( hysteresis ) and 6 ( mode ) during parametrisation. The corresponding values are set automaticly. M P P + + 5 / 6

Menu 6 mode Switching properties 1. Define the device s range first: The device should indicate ( LED) when the pressure is above the setpoints mode up-range has to be selected. under the setpoints mode down-range has to be selected. between the setpoints mode mid-range has to be selected. This mode is available for 2-stage devices only (...Bin-P...-2). 2. Select the switching characteristic of the relay: When the measu value is in range, the corresponding relays shall close select ly closed (nc) open select ly open (no) UP range Normally Closed (nc) Normal range above setpoint switch is closed The switch opens UP range Normally Open (no) Normal range above setpoint switch is open The switch closes Down range Normally Closed (nc) Normal range below setpoint switch is closed The switch opens Down range Normally Open (no) Normal range below setpoint switch is open The switch closes Mid range Normally Closed (nc) Normal range between setpoints switch is closed Mid range Normally Open (no) Normal range between setpoints switch is open 2-stage devices only 2-stage devices only 2-stage: 2-stage: 6 / 6