Similar documents
TIME-10 Process Control Stopwatch

TACH-10 Contact / Non-Contact Tachometer

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

PY-11 Voltage & Continuity Tester

THWD-3 and TH-3 Relative Humidity and Temperature Meters

Instruction Manual. IT-1 Infrared Thermometer

KMP Insulation-Continuity Tester. Users Manual

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

KMP7010. Ground Resistance Tester. Users Manual

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Infrared Thermocouple Probe

TMA5 Mini Vane Anemometer

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

TMD90A Dual Input Digital Thermometer

INSP-3 Wiring Inspection Tester

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

CO2-100 CO2 Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

flexible infrared thermometer

Noncontact Thermometer

302+/303 Clamp Meter. Users Manual

323/324/325 Clamp Meter

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

362 Clamp Meter. Users Manual

373 Clamp Meter. Users Manual

Users Manual. Phase Rotation Indicator

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

365 Detachable Jaw True-rms Clamp Meter

362 Clamp Meter. Users Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

Operator s Manual TC-253A. Temperature Converter


1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Users Manual. Airflow Meter

233 True-rms Remote Display Digital Multimeter Safety Information

i400s Calibration Information Introduction

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided,

712 RTD Calibrator. Instruction Sheet. Introduction

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Tachometer. English. Users Manual

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

i3000s/i2000 Flex AC Current Probe

1000FLT. Users Manual. Fluorescent Light Tester

Visit us at

12:1 WIDE-RANGE INFRARED THERMOMETER WITH STAR BURST LASER TARGETING

Calibration Manual. Detachable Jaw True-rms Clamp Meter

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

716 Pressure Calibrator

H2, HV2R, HV2G Rotary Laser Levels

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

OPERATING INSTRUCTIONS. TempCheck Non-Contact Infrared Thermometer IRT200 F C + -

Go to to register your product and find more information.

EDI K_Instructions.qxd 28/07/ :34 Page 1 ORDER CODE: EDI K MODEL IRT537. Infrared Thermometer OPERATING MANUAL CLASS 2 LASER

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

80PK-2A Type K Immersion Probe

P5510. Users Manual. Pneumatic Comparison Test Pump

Self-Leveling Cross Line Laser

Users Manual. MegOhmMeter

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Instruction Manual. Ex-MP4

TECHNICAL MANUAL. FOR BLAST 2 (Bright Light Aiming System Tactical 2) For Rifles and Pistols Equipped with MIL-SPEC-1913 and Picatinny Rails

FD Conveyor for FD 260 Tabber

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Model P772 Conductivity Meter. User Manual

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

60 Watt Industrial LED Low Bay Light

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

Cable Length Meter INSTRUCTION MANUAL

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

4-20mA DC PROCESS CLAMP METER

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ANALOG INSULATION RESISTANCE TESTER

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

Sawhorse with Chainsaw Holder

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available.

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Temperature Calibrator

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

LED Twister II. User manual UK Version 1.0

HIGH VOLTAGE PROXIMITY DETECTOR

Visit us at SOLAR-500. Solar Analyzer. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

CAMBELT TENSION GAUGE

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Adjustable Steel Welding Table

CONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.

Transcription:

IR-500 Infrared Thermometer / Voltage Detector / Flashlight Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

IR-500 Infrared Thermometer / Voltage Detector / Flashlight English Users Manual June 2011, Rev.1 2011 Amprobe Test Tools. All rights reserved. Printed in Taiwan

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase, unless local laws require otherwise. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center (see address next page).

Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates. In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600 Non-Warranty Repairs and Replacement Europe European non-warranty units can be replaced by your Amprobe Test Tools distributor for a nominalv charge. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. European Correspondence Address* Amprobe Test Tools Europe Beha-Amprobe GmbH In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009-0 www.amprobe.eu *(Correspondence only no repair or replacement available from this address. European customers please contact your distributor.)

IR-500 Infrared Thermometer / Voltage Detector / Flashlight 1 2 3 4 5 7 8 9 10 6 1) Laser 2) Flash light 3) Display 4) Flash light button 5) On button / Test button 6) Battery cover 7) Battery indicator 8) Laser indicator 9) NCV indicator 10) O C / O F

CONTENTS SYMBOLS... 1 UNPACKING AND INSPECTION... 2 INTRODUCTION... 2 OPERATING INSTRUCTIONS... 3 Power On / Off... 3 Auto Power Off... 3 Auto Hold... 3 Operating the unit... 3 Making Temperature Measurement... 4 C / F Selection... 5 Distance & Spot Size... 5 Reminders... 6 Emissivity... 7 Non-Contact Voltage... 8 SPECIFICATION... 9 TROUBLE SHOOTING... 10 MAINTENANCE AND REPAIR... 10 BATTERY REPLACEMENT... 11

SYMBOLS W Caution! Refer to the explanation in this Manual * Laser light. Do not stare into laser beam KY M Caution! Non-contact voltage Battery Do not apply directly or around bare hazardous live conductor. ; Conform to relevant Australian standards P Complies with European Directives Do not dispose of this product as unsorted = municipal waste. Contact a qualified recycler WSafety Information WWarning Do not stare into laser beam. Do not point laser directly at eye or indirectly off reflective surfaces. For use by competent persons only. Do not leave the unit on or near objects of high temperature. Non-Contact Voltage function can only test on insulated wires. Testing on high voltage wires should keep a distance of 20mm minimum. Do not use the unit to sense wire voltage higher than 600V. 1

WCautions Use this unit only as specified in this manual or the protection provided by the unit may be impaired. The unit should be protected from the following, EMF (electro-magnetic fields) from arc welders, induction heaters Static electricity Thermal shock (caused by large or abrupt ambient temperature changes - allow 30 minutes for unit to stabilize before use) Unpacking and Inspection Your shipping carton should include: 1 IR-500 1 1.5V AAA alkaline battery (installed) 1 Manual If any of the items are damaged or missing, return the complete package to the place of purchase for an exchange. INTRODUCTION A must-have tool for everyday applications, verify temperature, voltage presence and use it as flash light in dark places. Compact and easy to use - just aim, press the button, and read surface temperatures in less than a second. You can safely measure surface temperatures of hot, hazardous, or hard-to-reach objects without contact. Features IR temperature measurement with laser pointer Integrated non-contact AC voltage warning 2

Holds temperature reading for 10 seconds Ultra white LED flashlight Selectable o F / o C Pocket clip OPERATING INSTRUCTIONS Power On / Off press Auto Power Off 3 minutes. Auto Hold The unit will hold the reading for 10 sec after On button is released. Operating the Unit To measure a temperature, point unit at object and press the Test Button. Be sure to consider distance-to-spot size ratio and field of view. The unit is equipped with a laser, use the laser only for aiming. See Making Temperature Measurement. 3

Making Temperature Measurement Ta rget Area Incorrect Make sure that the target is larger than the unit s spot size. The smaller the target, the closer you should be to it. The minimum measurement area is 3.75cm (1.5in) diameter. Press the key, the unit will show the temperature of target surface. Then release the key, the LCD will hold the reading for 10 seconds. Press the key for 3 seconds, the unit will turn into the IR temperature continuous measurement mode. 4

C / F Selection Press Test button and Flash light button for 2 sec at the same time for switching temperature unit C/ F. Distance & Spot Size As the distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. Use the unit at around 30cm to get the best measurement accuracy. At longer distances, the target area shall be larger than the distance divided by 8. Please do not put the fingers on the housing for long period of time and cross the B line to prevent from thermo effect interference of measuring accuracy. 5

Reminders 1. Changes of surrounding ambient temperature can result in inaccurate reading, allow time for the unit to adopt the change of ambient before use. Specified accuracy applies after 30 minutes when the unit changes to a different environment ambient. Allow time for the unit to adopt the change of ambient from the user s pocket to enviroment ambient. 6

2. The unit cannot measure through transparent surfaces such as glass. Remove the barrier between the unit and the target surface. 3. Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, aluminum, etc.). See Emissivity. 4. Steam, dust, smoke, etc., can prevent accurate measurement by obstructing the unit s optics Emissivity Most organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or painted surface. 7

Non-Contact Voltage The Non-Contact Voltage function is ON automatically when the unit in standby mode. When Non-Contact Voltage is sensed, the LCD flashes three dashes and flash light flashes. The number of dashes displaying on LCD indicates the electric field intensity. The higher electric field is sensed, the more - symbols display on LCD. Non-Contact Voltage function can only test on insulated wires. Testing on high voltage wires should keep a distance of 20mm minimum. 8

SPECIFICATION Temperature -30 C to 500 C (-22 F to 932 F) Range Accuracy at 23 C ±2 C <80 % RH Best display Resolution Response Time Wavelength Emissivity D:S Repeatability Display Hold Non-Contact Voltage Power Weight Dimensions (HxWxD) Storage Temperature -30 C to 0 C (-22 F to 32 F): ±2 C (±4 F) 1 C to 10 C (34 F to 50 F): ±1.5 C (±3 F) 11 C to 40 C (52 F to 104 F): ±1 C (±2 F) 41 C to 500 C (106 F to 932 F): ±1.5 C (±3 F) or ±1.5% of reading, whichever is greater. 0.2 C (0.5 F) 0.5 s 6.5um to 18um E=0.95 8:1(calculated at 80% energy) ±1 C or ±0.5% of reading, whichever is greater. 10 s 60VAC ~ 600VAC 1.5V AAA alkaline battery Approx. 50g (0.11lb) 100 x 20 x 29mm (3.94 x 0.79 x 1.14in) -20 C to 60 C (without battery) CE Certification This instrument conforms to the following standards: EN 61326-1 Electromagnetic Emissions and Susceptibility EN 61010-1 General Safety EN 60825-1 Laser Safety 9

TROUBLESHOOTING Code Problem Action Battery icon Possible low battery Check and/or appears replace battery Blank display Laser doesn t work Possible dead battery Low or dead battery Check and/or replace battery Replace battery MAINTENANCE AND REPAIR Lens Cleaning: Blow off loose particles using clean compressed air. Gently brush remaining debris away with a camel s hair brush. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water or rubbing alcohol. NOTE: DO NOT use solvents to clean the plastic lens. Case Cleaning: Use soap and water on a damp sponge or soft cloth. NOTE: DO NOT submerge the unit in water. 10

BATTERY REPLACEMENT Please replace the battery when Battery indicator is flashing on display. When battery is replaced / installed, the unit will go into standby mode automatically 11