PREHEATER. Instruction Manual

Similar documents
Instruction Manual 8. USING THE TEMPERATURE CONTROL METER

SELF FEEDER. Instruction Manual TABLE OF CONTENTS

Preheater. Instruction Manual

High-output, temperature controlled soldering station. Instruction Manual

Soldering iron unit. Instruction Manual TABLE OF CONTENTS

FEEDER WITH SOLDER CUTTING FUNCTION

Desoldering Tool. Instruction Manual. Table of Contents

Desoldering Tool. (HAKKO FR-4101) Instruction Manual. Table of Contents

IRON TYPE GUN TYPE. Desoldering Tool. Instruction Manual

Switching DC Power Supply

Desoldering Tool. (HAKKO FR-4102) Instruction Manual. Table of Contents

QSSE, QSSEX INDUSTRIAL Battery Chargers

USER MANUAL TMT-PH200 IR PREHEATER.

Desoldering tool. Instruction Manual

1. PACKING LIST AND PART NAMES

I1 7.5 Pre-Lit Clear Christmas Tree

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

12 amp RMS Battery Charger

6.5 Multi Function C5 LED Pre-Lighted Tree Pre-Lighted Tree 96842

DISCHARGER-ANALYZER BDX USER'S MANUAL

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

ASSEMBLY INSTRUCTIONS

1.CONTENTS 1. Contents Control location Before riding Safe riding Driving Use genuine spare parts Use

User s Manual. Automatic Switch-Mode Battery Charger

A/C-HEATER SYSTEM - AUTOMATIC

BRITESTREAM LED FIBREGLASS NICHE POOL LIGHTS

MULTI-FUNCTION JUMP STARTER

VAL6 KBE5S. Service Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

7.0 Aspen Pine SYLVANIA Power-Lit TM M5 Warm White LED Pre-Lighted Tree V

BRITESTREAM SLIM90 FIBREGLASS POOL LIGHT

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

PRESSURE BOOSTER 150

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

KAC-9104D INSTRUCTION MANUAL

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Light Source User Guide

FOR INDOOR/SEASONAL USE ONLY

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

PowerFlex 700H and 700S AC Drives Frame 9 Main Fan Capacitor Replacement Kit

QPET, QPETXU Battery Chargers

Parts missing or damaged? Questions? Toll-free Helpline

Example Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

7.5 Oregon Fir With SYLVANIA Multi Color Mini Lights and Multi Color G50 Soft Glow Lights Pre-Lighted Tree V69139 INSTRUCTION MANUAL

OBE, OBEXU, ON BOARD Battery Chargers

OWNER S MANUAL Please read this manual before operating your power supply

Installation, Operation, and Maintenance Manual

OBAE, OBAEXU, ON BOARD Battery Chargers

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

CLEAN POWER TM CPS Series Operator s Manual

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

HLS Watt Halogen Illuminator Service Manual

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Triple Output Power Supply

SunPro Complete DE Fixture 1000W HPS

SeekTech Inductive Clamp

KAC-8104D INSTRUCTION MANUAL CLASS D MONO POWER AMPLIFIER B /00 (MV)

OWNER S MANUAL POWER INVERTER

Model 1693, 1694 Switching DC Power Supply

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

2003 LEGACY SERVICE MANUAL QUICK REFERENCE INDEX

Infrared oil heater. Model. Type. KBE5S for 120V 60Hz KBE5L for 120V 60Hz KBE5L 2-step for 120V 60Hz KBE1S for 230V 50Hz

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

SECTION 1 2 INSTRUMENTS AND CONTROLS. Switches

Go to to register your product and find more information.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Katalysator Nr /

945 SERIES SERVICE MANUAL

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

Light Source User Guide

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual

Cordless two speed drill/driver K 10613

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

KAC-8452 KAC-8402 INSTRUCTION MANUAL

11.Airbag Warning Light Failure

20V Lithium-Ion Battery Pack

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

General safety and installation information.

M-3025CB-AV Fuel Pump

365 Detachable Jaw True-rms Clamp Meter

12v / 24v Diesel Transfer Pump Kit

SECTION 1 2 INSTRUMENTS AND CONTROLS. Switches

KAC-718 INSTRUCTION MANUAL MONO POWER AMPLIFIER B (EM)

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

DC Master 24/ A

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

KAC-6203 INSTRUCTION MANUAL

Transcription:

PREHEATER Instruction Manual Thank you for purchasing the Hakko 853. This unit preheats electronic printed wiring boards. Please read this manual before operating the Hakko 853. Keep this manual readily accessible for reference. TABLE OF CONTENTS 1. PACKING LIST... 1 2. SPECIFICATIONS... 1 3. WARNINGS, S... 2 4. PART NAMES... 3 5. OPERATING INSTRUCTIONS... 3 6. OPERATING INSTRUCTIONS... 4 7. TROUBLE SHOOTING... 4 8. RESISTANCE MEASUREMENT FOR INVESTIGATING BROKEN HEATING ELEMENT AND SENSOR... 5 9. MAINTENANCE... 5 10. PARTS LIST... 6 11. WIRING DIAGRAM... 7

1. PACKING LIST Hakko 853... 1 Instruction manual... 1 2. SPECIFICATIONS Name Power consumption Hot air temperature Air flow Outer dimension Weight (w/cord) Hakko 853 100V-350W 120V-500W 230V-500W 110V-400W 220V-460W 240V-540W 120~250 C. (248~482 F.) 0.18m 3 /min. (6.35ft 3 /min.) 170 (l) x 140 (w) x 60 (h), mm. (6.7 (l) x 5.5 (w) x 2.4 (h), in.) 1kg. (2.2lbs.) * Specifications and design are subject to change without notice. * This product is protected against electrostatic discharge. 1

3. WARNINGS, S Warnings and cautions are placed at critical points in this manual to direct the operatorʼs attention to significant items. They are defined as follows: WARNING: Failure to comply with a WARNING may result in serious injury or death. : Failure to comply with a may result in injury to the operator, or damage to the items involved. Two examples are given below. When power is ON, air outlet temperatures will be between 120 and 250 C. (248 and 482 F.). To avoid injury or damage to personnel and items in the work area, observe the following: Do not touch the hot air outlet with your bare hands. Do not use ignitable gases, ignitable materials, or flammable objects close to the unit. Do not blow ignitable substances, ignitable objects, or flux onto the outlet. Do not insert anything into the outlet. Do not use with the outlet obstructed or with the unit surrounded by other objects. Inform other people in the area that the unit is hot and dangerous. Turn off the power when no longer using or when leaving the unit unattended. Before replacing parts or storing, cool the unit and then turn off the power. To prevent accidents or damage to the Hakko 853, be sure to observe the following: Do not use for any purpose other than preheating. Limit continuous use to approximately one hour. Be sure to ground the unit. Do not modify this unit. Use only genuine replacement parts. Do not place in water or use with wet hands. Hold the plug when connecting and disconnecting the cord. Avoid any other actions considered to be dangerous. 2

4. PART NAMES Guard plate Air outlet Power switch Power cord WARM/COOL switch Temperature control knob LED heater lamp 5. OPERATING INSTRUCTIONS PREPARATION Refer to the figure as shown at the right, and position the Hakko 853 and printed wiring board. Outlet 250 C. (482 F.) 170 C. (338 F.) Printed wiring board POWER ON Set the WARM/COOL switch to COOL and turn the power OFF. 40mm (1.6 in.) Plug in the power cord. This unit is protected against electrostatic discharge. Be sure to ground the unit. Temperature control knob is set to 250 C. (482 F.) Set the temperature. Turn power ON. Make sure the outlet is not obstructed before turning the power ON. 3

6. OPERATING INSTRUCTIONS Set the WARM/COOL switch to WARM. Hot air is discharged. Preheating begins. The LED heater lamp will light. When the designated temperature is reached, the lamp will flash. AFTER USE Set the WARM/COOL switch to COOL to cool the unit. Make sure the unit is completely cool, then turn the power OFF. 7. TROUBLE SHOOTING WARNING Unless otherwise directed, carry out these procedures with the power switch OFF and the power cord UNPLUGGED. If the power cord is damaged, it must be replaced only by the manufacturer or an authorized Hakko repair facility to preclude damage to either the unit or injury to personnel. Be sure the unit has cooled to room temperature before beginning work. TROUBLE-SHOOTING GUIDE Unit does not operate when power turned ON. Air is not discharged. Air does not become hot when WARM/COOL switch is set to WARM after power ON. CHECK Is the fuse blown? Investigate why the fuse blew and then replace the fuse. If the cause can not be determined, just replace the fuse. If the fuse blows again, send the unit in for repair. CHECK Is the fan motor working? Turn the fan by hand and check if the blades turn smoothly. If there is a problem, replace the fan or send the unit in for repair. CHECK Is the heating element broken? Measure the resistance value of the heating element as described on page 5. CHECK Is the sensor broken? Measure the resistance value of the sensor as described on page 5. CHECK Is the printed wiring board broken? Check the printed wiring board visually for burned parts. If there are parts with burn damage, replace the wiring board or send the unit in for repair. 4

8. RESISTANCE MEASUREMENT FOR INVESTIGATING BROKEN HEATING ELEMENT AND SENSOR Heating element connector Sensor connector This unit is protected against electrostatic discharge. Be sure to ground the unit. Heating element resistance measurement Sensor resistance measurement Remove the heating element connector and measure the resistance. Heating element resistance value: 25-30 Ω (100-120 V) 100-110 Ω (220-240 V) If the resistance value is incorrect, replace the heating element. (See the instructions included with the replacement heating element regarding how to replace the heating element.) Remove the sensor connector and measure the resistance. Sensor resistance value: 200-250 kω If the resistance value is incorrect, replace the sensor. (See the instructions included with the replacement sensor regarding how to replace the sensor.) 9. MAINTENANCE Wipe any flux deposits from the outlet and guard plate. 5

10. PARTS LIST * Spare or repair parts do not include mounting screws, if they are not listed on the description. Screws must be ordered separately. (M3 x 10) (4) Item No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Part No. B1487 B2604 B1906 B1904 B2427 B2428 B2429 B2430 B2431 B2432 B2433 B2608 B2434 B2435 B2496 A1433 A1437 B2437 A1432 A1436 B2439 B2440 B1041 B1236 B1257 B1247 B1208 B2442 B2497 B2498 B2499 B2500 Part name Power switch Power switch Switch Knob Potentiometer Cover Guard plate LED lamp Chassis Chassis / UL P.W.B. P.W.B. Transformer Transformer Transformer Sensor Sensor Pipe Heating element Heating element Fan Fan case Fuse holder Fuse, 125V-5A Fuse, 250V-5A Fuse, 250V-3A Cord stopper Cord stopper Power cord/3 core & American plug Power cord/3 core but no plug Power cord/3 core & European plug Power cord/3 core & BS plug Power cord/3 core & Australian plug Description 100-120V w/a screw w/rubber stopper w/rubber stopper 100-120V, 230V, CE 100-110V 120V 100-120V 100-120V 100-110V 120V 100-120V, 120V Korea India (Zn black) (M3 x 6) (6) Binding head tapping screw (Fluted point) (nominal size 3 x 6) with washer (M4 x 5) External tooth lock washer (nominal size 4) (M3 x 20) (2) with washer (M3 x 5) (2) with washer (M3 x 6) (M3 x 6) (2) Binding head tapping screw (nominal size 3 x 20) (2) with washer (M4 x 5) POWER ON WARM OFF COOL 150 248 302 120 TEMP 200 392 External tooth lock washer (nominal size 4) C F 250 482 6

11. WIRING DIAGRAM Power cord Fuse holder Power switch Switch Potentiometer LED AC 11V Red Black Transformer Sensor Heating element Triac Fan 7 HEAD OFFICE TEL:+81-6-6561-3225 FAX:+81-6-6561-8466 http://www.hakko.com E-mail:sales@hakko.com OVERSEAS AFFILIATES U.S.A.: AMERICAN HAKKO PRODUCTS, INC. TEL: (661) 294-0090 FAX: (661) 294-0096 Toll Free (800)88-HAKKO 4 2 5 5 6 http://www.hakkousa.com HONG KONG: HAKKO DEVELOPMENT CO., LTD. TEL: 2811-5588 FAX: 2590-0217 http://www.hakko.com.hk E-mail:info@hakko.com.hk SINGAPORE: HAKKO PRODUCTS PTE., LTD. TEL: 6748-2277 FAX: 6744-0033 http://www.hakko.com.sg E-mail:sales@hakko.com.sg Please access to the following address for the other Sales affiliates. http://www.hakko.com/address Copyright 2004 HAKKO Corporation. All Rights Reserved. 2004. 12 MA00009JU030224