IMPORTANT SAFEGUARDS

Similar documents
INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instructions Central Battery Units

SURE-LITES FBP140XLP Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation and Operation Instructions 10/04/13

EMIU 720W Mini Inverter

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

Self-Testing Industrial Series

Spectron Industrial Series

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation And Operation Instructions

UL AND CODE COMPLIANCE

Installation And Operation Instructions

MIRRORLITE RECESSED EMERGENCY LIGHTING

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

Installation And Operation Instructions

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

LMI Watt Models

Installation Instructions and User Manual For. 100 Watt Inverter Power System

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Installation Instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

SAVE THESE INSTRUCTIONS

Illuminator System Series CM

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Concealite Life Safety Products Model: F5000 Series. Save These Instructions. Read and Follow All Safety Instructions

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

Installation Instruction

Installation Instructions and User Manual For

Table of Contents. Pg. 2

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Cat# DC LED Array Emergency Driver

Powerware Vdc Extended Battery Cabinet User s Guide.

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

SAVE THESE INSTRUCTIONS

Illuminator System Series CIII

INSTALLATION & USER S GUIDE

OutdoorXUPS-600AHV-8364

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

MaxLite LED UTILITY WRAP FIXTURES

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual

FHSCP-UNV-10P-L-SD SPECIFICATIONS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

SAVE THESE INSTRUCTIONS

Owner's/Installation Manual

General Precautions. Personnel Precautions

This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit.

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

IMPORTANT SAFETY INSTRUCTIONS

PSL600 MVOLT SD INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Galaxy VM. Battery Breaker Box Installation 09/

Installing Power Components

1000-Watt Energy Center

Uninterruptible Power Supply

MODEL ELC-12/40-CVM-D BATTERY CHARGER

SAVE THESE INSTRUCTIONS

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

MODELS. 2 & 4 Low Profile Linears

Patient Care Facility

INSTALLATION & USER S GUIDE

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

MODEL ELC-12/60-D BATTERY CHARGER

MODELS 2 & 4 Top Conduit Linears

ITS-50R TRANSFER SWITCH OWNER S MANUAL

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

A2P Single Phase Automatic Industrial Battery Charger

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

RP-4000 Reserve Power Control

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Transcription:

INSTRUCTION MANUAL NON-INTERRUPTIBLE AC INVERTER SYSTEM MODEL EAC FTM 350 FOR EMERGENCY LIGHTING POWER IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: 1. DO NOT USE OUTDOORS. READ AND FOLLOW ALL SAFETY INSTRUCTIONS 2. Do not mount near gas or electric heaters. 3. Do not use this equipment for other than its intended use. 4. The EAC FTM 350 should be mounted securely and in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 5. The use of accessory equipment and replacement parts not recommended by the manufacturer may cause an unsafe condition and void the warranty. 6. The AC voltage rating of this equipment is specified on the product label. Do not connect the EAC FTM 350 equipment to any other voltage. 7. The EAC FTM 350 uses sealed valve regulated lead acid batteries. Batteries can be punctured if not handled properly, therefore use caution when servicing batteries. In the event battery acid comes in contact with eyes or skin, flush with fresh water and consult a physician immediately. 8. Install in accordance with the National Electrical Code and local regulations. 9. Installation and servicing should be performed by qualified personnel. 10. Electricians and end-users need to ensure product system compatibility before final installation. SAVE THESE INSTRUCTIONS THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY.

INSTALLATION INSTRUCTIONS CAUTION: Before installing, make certain the A.C. power is off. NOTE: The battery is shipped in separate packaging for ease of handling. Store the battery in a cool, dry and safe location until ready for installation. The battery may be kept in storage for up to 3 months without recharging. CAUTION: The EAC FTM 350 is a single voltage unit. It is designed for 120V input but is available in both a 120V output or a multi-tap output model. Before proceeding with the installation, verify that the EAC FTM 350 model you are installing matches both the AC supply and load fixtures voltages. Incorrect voltages will cause an unsafe condition, equipment failure, and may result in fire. 1. MOUNTING THE EAC FTM 350 1) Remove the front cover of the EAC FTM 350 by removing the two (2) screws located at the top of the cover. 2) Knock out the keyhole slots at the rear of the unit and use for mounting the EAC FTM 350 securely to the wall. There is an additional round hole for a #10 screw in the cabinet. Code requires that an additional screw be used through this hole to prevent the unit from being inadvertently lifted up off the keyhole slots. Do not drill any holes in this unit. If a recessed junction box is to be mounted in the wall behind the unit, make sure an unswitched AC supply of proper rated voltage is extended to the box, and that the remote wiring to the emergency fixtures is also extended to the box prior to mounting the unit. A 1/2 conduit knockout is provided in the back of the unit for wires to pass through. 16 of wire should be routed into the unit from the recessed junction box. NOTE: Input and output wires must be run in separate conduits. CAUTION: Do not drill holes into the cabinet; drill filings may damage the unit and keep it from operating. If larger knockouts are required, use a chassis-punch through the appropriate knockout to punch out a larger knockout. 3) If the wiring is to be external to the wall, extend both the unswitched supply and the load wires to the unit at this time. CAUTION: The approximate weight of the EAC FTM 350 is 120-lbs and must be mounted securely. Do not rely on the junction box for supporting the weight of the unit. Mount the EAC FTM 350 securely to the wall using the keyhole slots provided. ALWAYS CONSULT LOCAL CODES FOR STRUCTURAL REQUIREMENTS WHEN MOUNTING THE UNIT. 2. WIRING 1. CONNECTING THE NORMAL AC INPUT A. For 120V supply, connect the AC line wire to the BLACK lead labeled INPUT WIRES. B. Connect the Neutral wire to the WHITE lead labeled INPUT WIRES. C. Connect the ground wire in accordance with local and national codes. A GREEN Ground Wire is provided for this purpose. DO NOT ENERGIZE THE CIRCUIT AT THIS TIME. 2. CONNECTING REMOTE EMERGENCY FIXTURES A. Connect remote emergency fixtures to the wires labeled OUTPUT WIRES. If installing a 120V to 120V inverter unit, the output wires will be VIOLET and (see FIGURE 1). If this is a multi-tap unit (see FIGURE 2), then the wires are color-coded as follows: Common - Line 120V - VIOLET Line 208V - RED Line 240V - BLUE Line 277V - YELLOW Select the proper voltage lead and cap all unused leads. Do not use more than one output voltage. NOTE: All remote circuitry is to be wired in accordance with Article 700 of the National Electric Code. Do not exceed the total rating of the EAC FTM 350. See equipment label for proper rating. B. Connect the Fixture Supply Ground to the EAC FTM 350 Ground. Page 2

FIGURE 1 - EAC FTM 350 120-120 WIRING CONNECTIONS FOR 120V LOAD INPUT LEADS TEST SWITCH CHARGER / INVERTER OUTPUT LEADS 120V UNSWITCHED AC LINE BLK (120V) WHT (NEUTRAL) VIOLET 120V LIGHTING LOAD FLUORESCENT, INCANDESCENT, LED, HID AC LINE - CONNECT TO 120V AC INPUT ONLY GROUND LUG GROUND LUG - CONNECT FIXTURE SUPPLY GROUND AND UNIT GROUND IN ACCORDANCE WITH LOCAL CODE. INSTALL WIRES - DO NOT CONNECT INSTALL WIRES UNTIL AFTER AC POWER IS SUPPLIED. INSTALL LEADS FIGURE 2 - EAC FTM 350 120-MV WIRING CONNECTIONS FOR 120V, 208V, 240V AND 277V LOADS 120V UNSWITCHED AC LINE INPUT LEADS TEST SWITCH BLK (120V) WHT (NEUTRAL) CHARGER / INVERTER VIOLET OUTPUT LEADS YELLOW (277V) BLUE (240V) RED (208V) LIGHTING LOAD FLUORESCENT, INCANDESCENT, LED, HID VIOLET (120V) GROUND LUG 120 TO 277V 350W AUTOTRANSFORMER AC LINE -CONNECT TO 120V AC INPUT ONLY INSTALL LEADS GROUND WIRE - CONNECT FIXTURE SUPPLY GROUND AND UNIT GROUND IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. MULTI-TAP OUTPUT LEADS - SELECT THE PROPER VOLTAGE AND CAP ALL UNUSED LEADS. INSTALL WIRES - DO NOT CONNECT INSTALL WIRES UNTIL AFTER AC POWER HAS BEEN SUPPLIED. DO NOT ENERGIZE THE CIRCUIT AT THIS TIME. CAUTION: Before proceeding to Wiring Step 3, make sure that all unused wires are properly capped. Failure to do so may result in an unsafe condition and equipment failure. 3. INSTALLING THE BATTERY A. Before installing the battery, check the torque on the hardware that connects the polarized connector to the terminals as these connections may have loosened in transit and storage. The proper torques should be 70 in/lbs for a Screw Stud terminal, and 65 in/lbs for an L Flag terminal. B. Install the battery into the EAC FTM 350 with the terminal posts facing toward the front of the unit. NOTE: The EAC FTM 350 battery is heavy. To avoid injury, exercise caution when handling the battery. C. Plug the battery connector together. Note: Always apply proper torque to battery connections: For Screw Stud batteries, initial torque is 70 in/lbs, annual is 65 in/lbs. For L-Flag batteries, initial torque is 65 in/lbs, annual is 52 in/lbs. NOTE: The emergency indicator lights will not illuminate at this time. Page 3

4. COMPLETING INSTALLATION A. Energize the AC supply. The Ready (Yellow) Indicator will illuminate and the Inverter On (Green) Indicator will be off. Mate the wires labeled INSTALL WIRES on the left side of the unit. The Inverter On (Green) Indicator will illuminate at this time. The Alarm (Red) Indicator will be out. B. Operate the Test Switch for approximately 10 seconds. Observe that any emergency fixtures do not go out, then release the Test Switch. C. Properly reinstall the cover of the EAC FTM 350 using all the original hardware. D. Affix red EMERGENCY CIRCUIT label (provided) to the panelboard dead front cover near the circuit breaker feeding the EAC FTM 350. 3. OPERATION Normal Mode - AC power is present and operates the fixtures as intended. The EAC FTM 350 is in the standby charging mode. The Ready (Yellow) Indicator will be lit providing a visual indication that the unit is in Standby Mode. Emergency Mode - The AC power fails. The EAC FTM 350 senses the AC power failure and automatically switches to the Emergency Mode. All fixtures connected to the EAC FTM 350 will be illuminated for a minimum of 90 minutes. When the AC power is restored, the EAC FTM 350 switches the system back to the Normal Mode and resumes battery charging. See page 1 of the instruction manual for important operational safeguards and requirements. 4. TESTING 1) To test the equipment, depress the test switch. The Ready (Yellow) Indicator will go off. The designated fixtures will stay on and the Inverter On (Green) Indicator will remain lit. 2) Release the Test Switch. The Ready (Yellow) Indicator will come on. The equipment is supplied with an automatic solid state charger designed to fully recharge the battery within 24 hours after AC power is restored, and then maintain the battery in a fully charged state. Allow the battery to charge for a minimum of 24 hours after installation or power failure before conducting a 90 minute discharge test. The Life Safety Code and the Authorities Having Jurisdiction require that this test be performed on an annual basis. 5. MAINTENANCE 1. Alarm Indicator - Safety features within the EAC FTM 350 will force the unit to shut down under certain conditions. The red alarm indicator on the EAC FTM 350 will flash and the unit will shutdown in the event of over-voltage, low voltage, over-temperature, or system overload. In the event of a shutdown, contact Customer Service to troubleshoot for possible causes. 2. CAUTION: Before servicing, always follow proper shutdown procedure by 1) turning off the AC supply to the equipment, and 2) disconnecting the battery by unplugging the battery connector. Only qualified service technicians should service this equipment. The use of parts supplied by other than the manufacturer may result in an unsafe condition, equipment failure and will void the warranty. 3. BATTERY - The manufacturer recommends that the battery terminations be re-torqued on an annual basis. Re-torque specifications are as follows: Screw Stud terminals 65 in/lbs; L Flag terminals 52 in/lbs. The battery supplied in this equipment is a high quality maintenance-free Valve Regulated Lead Acid design. It requires no maintenance and when installed in an ambient temperature of 20-30 C (68-86 F) its life expectancy is 8 to 10 years. However, as stated above, the equipment must be tested for 90 minutes a minimum of once per year. When the battery will no longer operate the load for 90 minutes it must be replaced. Replace only with the manufacturer s supplied parts. Dispose or recycle the lead-acid battery properly. Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction. CONTACT CUSTOMER SERVICE FOR REPLACEMENT PARTS. SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL. ONE LITHONIA WAY, CONYERS, GEORGIA 30012, TELEPHONE 800-334-8694, FAX 770-981-8141 Page 4 EMCSA00798-REV A

BATTERY TORQUE SPECIFICATIONS FIGURE 1: ROUND TERMINALS (100 in. - lbs) FIGURE 2: SQUARE TERMINALS (65 in. - lbs) The batteries are shipped with the harness connected to the battery terminals at the proper torque specifications for the terminal type. If, for any reason, the harness must be reconnected to the terminals, refer to the specifications below for the proper torque for the terminal type: Round Terminals - 100 in. - lbs Square Terminals - 65 in. - lbs INSERT Page 5