DC REGULATED POWER SUPPLY

Similar documents
DC REGULATED POWER SUPPLY

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model 1672, 1673 Triple Output Power Supply

Model 1693, 1694 Switching DC Power Supply

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Model 1900, 1901, 1902 Switching DC Power Supply

SLA Battery Capacity Analyzer

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Model 1900, 1901, 1902 Switching DC Power Supply

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

DC POWER SUPPLY ALIMENTATION C.C.

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Triple Output High Resolution Power Supply. User Manual

Instruction Manual. Model 310 Digital Milli-Ohm Meter

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Model P772 Conductivity Meter. User Manual

Triple Output Power Supply

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

INSTRUCTION MANUAL Model 1743B

HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY

Switching DC Power Supply

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

DC POWER SUPPLY GPS-S SERIES (ANALOG 1 DIGITAL TYPE) User Manual ISO-9001 CER TIFIED MANUFACTURER

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

RU BMS Power Supply and Battery Management System Owners Guide

Digital/Analog Megohmmeter Model 1026 USER MANUAL

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

PROwatt 150 DC to AC Power Inverter. Owner s Guide

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

3000 Series Operation Manual

WARNINGS, CAUTIONS AND NOTES

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

Table of Contents Title Page No.

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

DC POWER SUPPLY (Switching mode)

MANLEY LABORATORIES, INC. MANLEY REFERENCE JUNIOR DAC OWNER'S MANUAL 20 BIT DIGITAL TO ANALOG CONVERTER

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

ATD-5570 Deluxe Automotive Meter with RPM and Temperature Functions Owner s Manual Features:

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

5-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

User s Manual Rev 1.3 GME

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

Go to to register your product and find more information.

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

5.2 PRE-OPERATION PROCEDURE WARRANTY

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

INSP-3 Wiring Inspection Tester

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

BRAVO Inverter/Battery Charger. Table of Contents

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual

Owners Manual. Autosound Series Power Supply APS-100 APS-100X

Using Your SMT Micro Anodizer 0-120VDC/0-1A

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Dawson DAN100. Analog Multimeter User s Manual

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

3-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SECTION DC POWER SUPPLY/BATTERY CHARGER

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Item no Smart AC 200 USB. User s Manual

10 Ch Peak & Hold Injector Driver PN

For technical questions and replacement parts, please call

ADI-125/750 ADI-125/1500 ADI-125/2500

A1P OPERATING MANUAL

CLEAN POWER TM CPS Series Operator s Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Declaration of Conformity

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Installation Instructions for: Channel Thermocouple Amplifier

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

DC to DC Step Up Converter Model: VTC305

User's Guide. True RMS Multim eter. Extech 430

Phase Sequence Tester

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Digital/Analog Megohmmeter Model 1026

OWNERS MANUAL JANUARY 2007 ISO

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

OPERATING INSTRUCTIONS

RESISTIVITY MONITOR/CONTROLLERS

Transcription:

INSTRUCTION MANUAL Models 1620A/ 1621A/ 1622A/ 1623A/ 1626A/ 1627A MANUAL DE INSTRUCCIONES DC REGULATED POWER SUPPLY

TABLE OF CONTENTS 1. INTRODUCTION... 3 2. FEATURES... 3 3. SPECIFICATIONS... 4 4. PRCAUTIONS FOR USE... 6 4.1 Confirming the supply range... 6 4.2 Precautions for connection of output terminals... 6 4.3 Operating environment... 7 5. EXPLANATION OF PANEL... 7 5.1 FRONT PANEL... 7 5.2 REAR PANEL... 9 6. OPERATION PROCEDURES... 10 6.1 Stand-alone operation... 10 6.2 Serial connection... 10 6.3 Parallel operation (MASTER / SLAVE Control)... 11 7. MAINTENANCE...13 7.1 Main fuse replacement...13 7.2 Calibrations...13 7.3 Voltage calibration...14 7.4 Voltmeter alignment...14 7.5 Current calibration...14 7.6 Ammeter alignment...14 LIMITED WARRANTY...15 SERVICE INFORMATION...16 2

1. INTRODUCTION The BK Precision Analog and Digital series are high quality serial control type DC Regulated Power Supplies. These models can be operated at constant voltage or constant current mode whose output can be varied from 0 up to the rated values for respective model. It is a compact unit provided with separate voltage and current meters (Analog for 1620A, 1622A, 1626A and 3-digit LEDS for 1621A, 1623A, and 1627A series) for monitoring the output voltage and current simultaneously. In terms of operability, these units enable high precision, continuous variability via coarse and fine adjust knobs. The BK Precision Analog and Digital series can be connected in parallel with multiple units of the same model set up a master/slave configuration to increase the output current capability. Serial connection of multiple units can be used to increase the output voltage level. This family of power supplies provides clean and stable DC output which is most suitable for many areas including laboratory, industrial, field service, hobby, and telecommucation applications. 2. FEATURES The BK Precision Analog and Digital series are constant voltage / constant current power supplies which feature excellent line and load regulations, low ripple and noise characteristics. The units feature separate voltage and current meters so that output voltage and current can be monitored simultaneously. Output voltage and current can be adjusted continuously in full range to any desired values. Adjustment can be done easily and precisely by using separate coarse and fine adjust knobs. The constant current circuit operates to protect against overload and output short circuit. The limiting current values can be preset in the full range of the rated values for respective model. Multiple units of power supplies of same family can be connected in series to provide higher output voltage. Multiple units of power supplies of SAME model can be connected in parallel (master / slave configuration) to achieve higher output current. 3

3. SPECIFICATIONS 1620A 1626A 1622A 1621A 1627A 1623A OUTPUT VOLTAGE 0-18V 0-30V 0-60V 0-18V 0-30V 0-60V OUTPUT CURRENT 5A 3A 1.5A 5A 3A 1.5A CONSTANT VOLTAGE CHARACTERISTICS Load regulation (0-100%) 0.02% +3mV Line regulation (120VAC + 10 %, -6 % ) Ripple and noise r.m.s CONSTANT CURRENT CHARACTERISTICS Load regulation (0-100%) Line regulation (120VAC + 10 %, -6 % ) OUTPUT Output terminals ( color ) Ground proof voltage INSTRUMENTATION 0.02% +3mV 0.02% +3mV 0.02% +3mV 0.02% +3mV 0.02% +3mV 0.02% +3mV 4 1mV max. 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA 0.02% +3mA ( + ) Red, ( ) Black, ( GND ) Green ± 180V Voltmeter Analog 3 digits LEDS Ammeter Analog 3 digits LEDS Voltmeter accuracy ± 7% fs ± 2% + 2 digits Ammeter accuracy ± 7% fs ± 2% + 2 digits

FUNCTIONS Serial connection ( independent control mode ) Parallel operation ( master slave mode ) COOLING SYSTEM POWER CONSUMPTION VA / W ( for rated load of AC 220V ) AC INPUT Voltage, Frequency Can be connected in series ( within limits of ground proof voltage ) Can be operated in one-control parallel configuration ( only same model ) Natural Convection Approximate 210 Approximate 220 120V AC ± 10%, 60 Hz (120/220/230/240V AC ± 10%, 50/60Hz version available) Operating ambient temperature 5 to 40 C 10 80% R.H. DIMENSIONS AND WEIGHT Dimensions ( W x H x D ) 205 x 115 x 270 ( mm ) Weight Approximate 6 Kgs Approximate 7.4 Kgs FUSE RECOMMENDED Input fuse F2 AC 100V, 110V, 120V AC 220V, 230V, 240V Internal fuse F1 3AF 2AF 500mAF NOTE: Specifications and information are subject to change without notice. Please visit www.bkprecision.com for the most current product information. 5

4. PRECAUTIONS FOR USE 4.1. CONFIRMING THE SUPPLY RANGE The unit must be used within its specified range. The rated input voltage can be found on the rating table under the unit. Before plugging into the AC supply outlet, check if the input rating conforms to your local supply. For certain models, a voltage selector is available, switch the voltage selector to the correct position before use. Also, please check that you have the correct fuse inserted in the fuse box below the AC input receptacle. 4.2. PRECAUTIONS FOR CONNECTION OF OUTPUT TERMINALS These units are a floating type power supply. For ordinary use, be sure that the MASTER/SLAVE switch on the rear panel is set to MASTER position and either the (+) output terminal or the ( ) terminal is connected to the GND terminal (chassis GND) via the shorting bar. 4.3. OPERATING ENVIROMENT Be sure to use this unit within the specified ambient temperature range listed in the specification table. Because the unit is cooled by natural convection, do not place objects on top to block the convection. Also user must avoid placing the unit on or near any heat emitting devices or use multiple units in stacked configuration. For best results, use the unit in an environment that has good cross-ventilation. Altitude up to 2000M Installation category: CAT II Pollution degree: 2 Indoor use only Warning: For model 1622A and 1623A, the maximum output voltage is up to 60Vdc. Touching the live metal part of output terminals may be hazardous. User must avoid touching the live metal part of output terminals. 6

5. EXPLANATION OF PANELS 5.1 FRONT PANEL Fig. 5.1 7

1. Power switch Turns the power supply ON-OFF. The switch will be lighted up when the unit is ON. 2. DC Voltmeter Indicates the present output voltage. (Analog for 162A, 1622A, 1626A and 3-digit LEDS for 1621A, 1623A, and 1627A series) 3. DC Ammeter Indicates the present output current. (Analog for 162A, 1622A, 1626A and 3-digit LEDS for 1621A, 1623A, and 1627A series) 4. Constant current mode (C.C.) indicator Indicates the power supply is operating in constant current mode. 5. Constant voltage mode (C.V.) indicator Indicates the power supply is operating in constant voltage mode. 7. Voltage fine adjust Fine adjust knob for the output voltage in voltage mode. 8. Current coarse adjust Coarse adjust knob for current limiting point and current value in constant current mode. 9. Current fine adjust Fine adjust knob for current limiting point and current value in constant current mode. 10. Output terminal positive (+) Terminal for tapping of positive (+) output. 11. Output terminal negative ( ) Terminal for tapping of negative ( ) output. 12. Ground terminal (GND) Chassis ground terminal. Normally, this is connected to either (+) or ( ) terminal depend on application. 6. Voltage coarse adjust Coarse adjust knob for the output voltage in voltage mode. 8

5.2 REAR 13. Master / Slave switch Used during master / slave control parallel operation in MASTER / SLAVE configuration. For normal operation, switch should be set to MASTER. 14. In / out terminals for Master / Slave operation Control terminals for use in the MASTER / SLAVE control parallel operation mode. 15. Heat sink Heat sink for the power supply. Be careful as this area can become quite hot during operation. 16. Main Fuse 17. Power cable 9

6. OPERATION PROCEDURES 6.1. STAND-ALONE OPERATION When using the power supply in stand-alone mode, simply operate by manipulation of the panel switches and adjustment knobs as needed. However, be sure that MASTER / SLAVE switch is set to MASTER position. PLUS / MINUS CONNECTION For connection as shown in FIG.6.2 where the intermediate point is hooked up to ground, the configuration can be used as Plus / Minus power supply. 6.2. SERIAL CONNECTION Two or more units of the power supply can be hooked up in series to achieve higher output voltage. The resulted output will be sum of the outputs of the individual units. In this situation, however, care must be taken that the voltage of neither of the terminals with respect to the chassis GND exceed the ground proof voltage of + 180V FIG. 6.1 SINGLE VOLTAGE CONNECTION For connection as shown in FIG.6.1, the output voltage will be the sum of individual supplies and output current will be limited to within the value specified for a single unit whichever is lower. For positive ground terminal to output positive point and for negative ground system, hook-up the ground terminal to the negative output point. FIG. 6.2 10

6.3. PARALLEL OPERATION (MASTER / SLAVE CONTROL) Two or more units of the same model can be hooked up in parallel to give an increase in output current capacity. The total output current capacity will be the sum of the output currents of the individual units. In this mode of operation, one supply will act as the master and all settings are from the master unit Note: When connecting the supplies in parallel, be sure that all the power supplies are turned OFF. HOOK-UP PROCEDURES 1. Switch OFF the power of all units. 2. Switch the master/slave switch, FIG.6.3, on all the slave units from MASTER to SLAVE position. 3. Hook-up the IN/OUT terminals for MASTER/SLAVE operation as shown in FIG.6.3. 4. Connect the output terminals of each of the units to the load as shown in FIG.6.4. For proper performance, use all cables of same length and thickness. 6. Switch ON the MASTER unit and SLAVE units. The output voltage and current then can be controlled to the desired value via the adjustment knobs on the MASTER unit. In the case of output goes to 0 ampere in the parallel operation mode, output voltage can no longer be controlled by the master machine. Be sure to keep a minimum current flowing that is at least several percent of the rated current at all time. CONNECTION OF TERMINAL ON REAR PANEL While pressing on the slit portion of the terminal with a small screw driver, insert the connecting cable into the round hole. When insertion is completed, release the screw driver. (FIG.6.5) 5. Set the voltage and current adjustment knobs of all the slave units to the maximum position. 11

FIG. 6.3 FIG. 6.4 FIG. 6.5 12

7. MAINTENANCE WARNING: The following instructions are for use by qualified personnel only. To avoid electrical shock, do not perform any servicing other than those contained in the operating instructions unless you are qualified to do so. 7.1 MAIN FUSE REPLACEMENT However, calibrations should be attempted only if a 3½ digit multimeter with an accuracy of +0.5% DCV or better and a 0 to 50ohm, 250 Watt adjustable resistive load is available. If re-calibration is required, use the following procedures. Locations of the electrical calibration on the main PCB are shown in FIG. 7.1. If the main fuse blows, the power on the LED indicator will not light and power supply will not operate. The fuse should not normally blow unless a problem has developed in the unit. Try to determine and correct the cause of the blown fuse, then replace only with a fuse of correct rating. The fuse is located on the rear panel and fuse rating can be found next to the fuse holder. If the problem persists, return the unit to the agent for further investigation. 7.2 CALIBRATION This unit has accurately calibrated at the factory before shipment. Recalibration is recommended only if repairs have been made in a circuit affecting calibration accuracy, or if you have reason to believe the unit is out of calibration. FIG. 7.1 13

7.3. VOLTAGE CALIBRATION 1. Connect the multimeter to measure the DC voltage across the power supply (+) and ( ) output terminals. 2. Turn on the power supply, and turn the panel VOLTAGE adjustment knob fully clockwise (maximum output). 3. Adjust trimmer VR11 for a reading (Vmax. +0.5) ±0.1 volts on the multimeter. Vmax is the maximum normal output of the specific model under calibration. 7.4. VOLTAGE ALIGNMENT 1. Set the output voltage to about half the maximum allowable output for respective model. 2. Align the voltmeter reading with the multimeter reading. For BK Precision Analog series, adjust the trimmer VR-6 on the main PCB. For BK Precision Digital series, adjust the trimmer VR-1 on the back of meter PCB. 7.5. CURRENT CALIBRATION 1. Connect the 0 50ohm / 250W resistive load in series with the multimeter to measure the DC output current terminals. 2. Adjust trimmer VR-5 fully anti-clockwise (referring to the component side). 3. Adjust the output voltage to the maximum allowable output for respective model. 4. Adjust the variable resistive load to obtain (Imax +0.1) ±0.02 Ampere on the multimeter. Imax is the maximum nominal allowable output current of resistive model. 5. Adjust trimmer VR-5 clockwise slowly until the limiting point is just reached and the C.C. LED lights up at the same time. 7.6. AMMETER ALIGNMENT 1. Adjust the output voltage to half of its maximum allowable output voltage for respective model. 2. Adjust the variable resistive load to obtain half of its maximum allowable current for respective model. 3. Align the ammeter reading with the multimeter reading. For BK Precision Analog series, adjust the trimmer VR-7 on the main PCB. For BK Precision Digital series, adjust the trimmer VR-2 on the back of meter PCB. 14

Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its products and the component parts thereof, will be free from defects in workmanship and materials for a period of three years from date of purchase. B&K Precision Corp. will, without charge, repair or replace, at its option, defective product or component parts. Returned product must be accompanied by proof of the purchase date in the form of a sales receipt. To help us better serve you, please complete the warranty registration for your new instrument via our website www.bkprecision.com Exclusions: This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs. The warranty is void if the serial number is altered, defaced or removed. B&K Precision Corp. shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitations of incidental or consequential damages. So the above limitation or exclusion may not apply to you. This warranty gives you specific rights and you may have other rights, which vary from state-to-state. B&K Precision Corp. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 714-921-9095 15

Service Information Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging with proof of purchase to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Non-Warranty Service: Please go to the support and service section on our website at www.bkprecision.com to obtain a RMA #. Return the product in the original packaging to the address below. Clearly state on the RMA the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Customers not on an open account must include payment in the form of a money order or credit card. For the most current repair charges please refer to the service and support section on our website. Return all merchandise to B&K Precision Corp. with prepaid shipping. The flat-rate repair charge for Non-Warranty Service does not include return shipping. Return shipping to locations in North America is included for Warranty Service. For overnight shipments and non-north American shipping fees please contact B&K Precision Corp. B&K Precision Corp. 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 714-921-9095 Include with the returned instrument your complete return shipping address, contact name, phone number and description of problem. 16

22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com 2014-2017 B&K Precision Corp. Printed in China PN# 481-375-9-001 v121417 17