General information on current-limiting fuse-links. The main characteristics of the CNC fuse-links. Construction. Operating.

Similar documents
High-Voltage Fuse-Links

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

HIGH VOLTAGE FUSE-LINKS HIGH VOLTAGE FUSE-LINKS WITH THERMAL STRIKER HIGH VOLTAGE FUSES POWER NEEDS CONTROL

High voltage high-breaking capacity VV fuse-links

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

Medium Voltage current limiting Fuse links

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

Medium Voltage current limiting Fuse links

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

Limitor -G General Purpose Fuses

Low voltage NH knife-blade fuse-links

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

High voltage current limiting Fuse links type CEF

High-voltage high-breaking capacity VV fuse-links

High-Voltage Fuse Links according to IEC

FUSES. Safety through quality

High-voltage high-breaking capacity VV fuse-links

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Standardized fuse characteristics

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Mica Element Support. Compacted Quartz Sand. Length B

INDUSTRIAL CYLINDRICAL FUSE LINKS

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

IEC Standard Back-Up Fuse-Links

Applications. Fuse range selection. Motors Power transformers. Voltage (kv)

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

Medium voltage products. Fuses

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

Medium voltage products. Fuses

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

fuse-links & fuse holders PHOTOVOLTAIC

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

EUROFUSE MULTIBLOC MULTIVERT D/D0-FUSE-SYSTEM BSL NH-FUSE-MATERIAL MULTIFIX 60 CYLINDRICAL FUSE-SYSTEM MINIATURE FUSE LINKS HIGH VOLTAGE FUSE LINKS

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

Boric Acid Fuse Links

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

IEC Low Voltage Products Module 4

HIGH VOLTAGE CURRENT LIMITING FUSE-LINKS CAPABLE OF BREAKING ALL CURRENTS THAT CAUSE MELTING OF THE FUSE-ELEMENT. D. van der Scheer H.F.J.

Medium Voltage Fuse Links Full Line Catalogue

FX Full-Range Current-Limiting Fuse

Fuses are the most effective and economic ways of protection against short circuits in m.v. installations.

Cylindrical fuse-link

CYLINDRICAL FUSES CYLINDRICAL FUSES

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

34-SDMS-02 SPECIFICATIONS FOR

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

SAFETY FUSES PP57U SERIES Technical description and user manual

LG HRC Power Fuses ISO 9001 ISO 14001

Protistor size 70 gr 690VAC (IEC)

Medium voltage fuses - European Fuses

RAPIDPLUS. high speed fuse links for semiconductors

Circuit Protection Solutions. Medium Voltage DIN Fuses

NH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a

Medium voltage fuses Medium voltage fuses

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM

RAPIDPLUS. high speed fuse links for semiconductors

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

NX indoor current-limiting fuses

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

NEOZED D0 fuse-links gg 400/440VAC

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Medium Voltage Distribution. Fuses. from 3.6 to 36 kv. Catalogue 2012

Power systems Protection course

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

New fem model for thermal analysis of medium voltage fuses

NH Solid Blades 690 VAC sizes 000 to 3

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

Leadership in fusible circuit protection solutions

NH LOW VOLTAGE a FUSE SYSTEM

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

BUSSMANN. Leadership in fusible circuit protection solutions SERIES. Bussmann series Medium voltage fuse links catalogue

Cylindrical fuse-link

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

fuses fuse holders CYLINDRICAL

Utilisation category gl/gg 500VAC with combi indicator

THIN FILM FUSE LINK. R D Harrison*, I Harrisont, A F Howet.

MV SWITCHGEAR 511. CF / SOLEFUSE / TEPEFUSE / MGK MV current limiting fuses With thermally operated striker From 3.6 to 36 kv

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

OHB Outdoor sulphur Hexafluoride circuit-breaker

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

RBA Catalog Numbers and Information

General Purpose IEC Fuses

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

FUSE BASES NH FUSE BASES 690V 160A 160A

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE

Use of switch-fuse combinations at the medium-voltage level for the protection of distribution transformers siemens.com/tip-cs

Bussmann 7.2 kv Medium voltage fuse links

X-Limiter full-range current-limiting fuse

EMPAC Metal enclosed capacitor bank for wind applications

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

Transcription:

General information on current-limiting fuse-links The high-voltage back-up current-limiting fuse-links are designed for protection of systems which include transformers, against the destructive results of short-circuits and overloads, by limiting the thermal and electrodynamic effects of the short-circuit currents. The fuse-links are complying with the industry standards - IEC 60282-1:2002, DIN 43625 and IEC 60787 - and can be used both in outdoor and indoor applications. The main characteristics of the CNC fuse-links High breaking capacity up to 50 ka imitation of the short-circuit currents at low levels ow power dissipation more energy savings and less heating Reliable interruption of the critical currents Minimum breaking current is relatively low, starting from 3xIn ow switching voltage lower than 60 kv ow level of the cut-off current Unlimited lifetime due to the usage of pure silver melting element Same design for both indoor and outdoor usage Reliable proofing against humidity penetration of the fuse-link interior Highly qualitative raw materials and components. Construction The melting elements, consisting of pure-silver wire or strip, having variable sections, are precisely wounded on a ceramic carrier, ending with copper terminal parts. Inside the cylindrical cavity of the carrier is a helical wire with the role of activating the striking system. The striker is used to indicate the blown of the fuse-link and it also can activate other systems. There are also models without striker. The carrier system is introduced in a ceramic tube, sealed at ends with protective caps of nickel-plated copper, which are also acting as contacts when mounting in the basement. The inside space of the tube is filled with material for extinguishing electrical arcs, made of quartz sand with tight-controlled purity and granularity. Inside the fuse-link tube all the contacts are made through spot welding. The cooper caps are mechanically attached to the ends of the tube and proofed against humidity penetration through the use of O-shaped seals of high-temperature resistant rubber. The caps, which are the contact parts of the fuse-link, are of two types, according to specifications of DIN 43625 and IEC 60282-1: Diameter of 45 mm (series: EA, EPA, EMA, EMPA) Diameter of 56 mm (series: EB, EPB, EMB, EMPB) Operating When the current is between the minimal breaking and the nominal breaking values the fuse element melts and evaporates, appearing the electrical arc. The arc is cooled and extinguished by the extinguishing element of the fuse-link, thus ensuring the protection of the main circuit against damages. Product series 1 Contact Diameter Tube Diameter With Striker Without Striker 45 mm 45 mm EPA EA 75 mm EMPA EMA 56 mm 45 mm EPB EB 75 mm EMPB EMB

Technical data Product Code Rated Voltage Un (kv) Rated Current In Rated Breaking Capacity I1 (ka) Minim Breaking Current I3 Power Dissipation Cold Resistance ength Diameter Weight (W) (mω) (mm) (mm) (kg) E(P)A/B-7,2-2,5 7,2 2,5 50 7.5 4,5 880 192 45 1,1 E(P)A/B-7,2-4 7,2 4 50 12 7,2 421 192 45 1,1 E(P)A/B-7,2-6,3 7,2 6,3 50 20 9,4 187 192 45 1,1 E(P)A/B-7,2-10 7,2 10 50 31 18,7 1 192 45 1,1 E(P)A/B-7,2-16 7,2 16 50 52 20,9 52 192 45 1,1 E(P)A/B-7,2-25 7,2 25 50 96 21 192 45 1,1 EM(P)A/B-7,2-31,5 7,2 31,5 50 125,6 17,3 192 75 2,3 EM(P)A/B-7,2-40 7,2 40 50 200 32 13,8 192 75 2,3 EM(P)A/B-7,2-50 7,2 50 50 250 39,7 9,7 192 75 2,3 EM(P)A/B-7,2-63 7,2 63 50 320 40,9 5,4 192 75 2,3 EM(P)A/B-7,2-80 7,2 80 50 550 45 4 192 75 2,3 E(P)A/B-12-2,5 12 2,5 40 8 8 1443 292 45 1,6 E(P)A/B-12-4 12 4 40 12 11,4 715 292 45 1,6 E(P)A/B-12-6,3 12 6,3 40 20 16,9 315 292 45 1,6 E(P)A/B-12-10 12 10 40 31 30,9 210 292 45 1,6 E(P)A/B-12-16 12 16 40 52 34,1 90 292 45 1,6 E(P)A/B-12-25 12 25 40 96 37 41 292 45 1,6 EM(P)A/B-12-31,5 12 31,5 40 125 40,6 28,5 292 75 3,9 EM(P)A/B-12-40 12 40 40 200 53,6 22,8 292 75 3,9 EM(P)A/B-12-50 12 50 40 250 63,2 15,9 292 75 3,9 EM(P)A/B-12-63 12 63 40 320 71,9 8,9 292 75 3,9 EM(P)A/B-12-80 12 80 40 550 72,5 6,6 292 75 3,9 E(P)A/B--2,5 2,5 31,5 8 19,5 2680 45 1,8 E(P)A/B--4 4 31,5 12 29,6 1331 45 1,8 E(P)A/B--6,3 6,3 31,5 20 33,7 613 45 1,8 E(P)A/B--10 10 31,5 31 71,2 414 45 1,8 E(P)A/B--16 16 31,5 52 75,2 181 45 1,8 E(P)A/B--25 25 31,5 96 81,2 82 45 1,8 EM(P)A/B--31,5 31,5 31,5 125 83,1 54,9 75 4,5 EM(P)A/B--40 40 31,5 200 129,1 43,9 75 4,5 EM(P)A/B--50 50 31,5 250 147,5 30,7 75 4,5 EM(P)A/B--63 63 31,5 320 151,9 17 75 4,5 EM(P)A/B--80 80 31,5 550 153,2 12,8 75 4,5 2

Time-current characteristic and cut-off current diagram Current (Aef) Current (Aef) Cut-off current Cut-off current Pre-arcing Time (s) Pre-arcing Time (s) Prospective short-circuit current (Akef) Prospective short-circuit current (Akef) The time-current specifications are for a temperature of 15-20 O C of the surrounding environment. If the fuselink is to be used in closed environments with other sources of heat, the user should contact the manufacturer for choosing the right models of fuse-link. 3

Dimensions EPA, EPB U n [kv] 7,2 12 [mm] 192 292 U n [kv] 7,2 12 [mm] 192 292 4

Dimensions EMPA, EMPB U n [kv] [mm] 7,2 12 192 292 U n [kv] 7,2 12 [mm] 192 292 5

How to select the fuse-link model According to the specifications of IEC 787 it is recommended the usage of the following fuse-links depending on the rated power of the transformers to be protected. Un Pn In Primary Short-circuit Voltage Connection Rate Current of the Fuse-link Group (KV) (KVA) (%) In (min) 20 25 0,72 4 Yzn-5 4 4 20 40 1,15 4 Yzn-5 4 6,3 20 63 1,81 4 Yzn-5 6,3 10 20 100 2,88 4 Yzn-5 10 16 20 160 4,61 4 Yzn-5 16 16 20 250 7,21 6 Dyn-5 16 16 20 400 11,5 6 Dyn-5 25 25 20 630 18,18 6 Dyn-5 31,5 50 20 1000 28,8 6 Dyn-5 50 63 20 1600 46,1 6 Dyn-5 63 80 10 25 1,44 4 Yzn-5 6,3 10 10 40 2,31 4 Yzn-5 10 10 10 63 3,63 4 Yzn-5 10 16 10 100 5,76 4 Yzn-5 16 25 10 160 9,23 4 Yzn-5 25 31,5 10 250 14,43 6 Dyn-5 31,5 40 10 400 23,11 6 Dyn-5 40 50 10 630 36,37 6 Dyn-5 50 63 10 1000 57,6 6 Dyn-5 63 80 6 25 2,4 4 Yzn-5 6,3 10 6 40 3,85 4 Yzn-5 10 16 6 63 6,06 4 Yzn-5 16 16 6 100 9,62 4 Yzn-5 25 31,5 6 160 15,39 4 Yzn-5 31,5 40 6 250,05 6 Dyn-5 40 50 6 400 38,5 6 Dyn-5 50 63 6 630 60,6 6 Dyn-5 63 80 6 1000 96,2 6 Dyn-5 100 100 6 1600 153,9 6 Dyn-5 160 160 In (max) Operation and maintenance requirements For indoor usage the fuse-links could be mounted either horizontally or vertically. For outdoor applications the fuse-links should be mounted only vertically with the strike system downwards. Replacement of the blown fuse-links should be done only complying to the requirements of the work safety techniques and only by personnel trained and qualified for working with high-voltage installations. The operations are forbidden if current is flowing in the circuit. The blown fuse-links should be replaced only with new ones. In case of tri-phases circuitry, after burning one fuse-link the fuses for all phases should be replaced. It is recommended to examine periodically the status of the protective coverings of the fuse-links contacts. 6

Ordering information Un (kv) In Diameter of Contact 45 mm 56 mm With Striker Without Striker With Striker Without Striker 2,5 EPA--2,5 EA--2,5 EPB--2,5 EB--2,5 4 EPA--4 EA--4 EPB--4 EB--4 6,3 EPA--6,3 EA--6,3 EPB--6,3 EB--6,3 10 EPA--10 EA--10 EPB--10 EB--10 16 EPA--16 EA--16 EPB--16 EB--16 25 EPA--25 EA--25 EPB--25 EB--25 31,5 EMPA--31,5 EMA--31,5 EMPB--31,5 EMB--31,5 40 EMPA--40 EMA--40 EMPB--40 EMB--40 50 EMPA--50 EMA--50 EMPB--50 EMB--50 63 EMPA--63 EMA--63 EMPB--63 EMB--63 80 EMPA--80 EMA--80 EMPB--80 EMB--80 12 2,5 EPA-12-2,5 EA-12-2,5 EPB-12-2,5 EB-12-2,5 12 4 EPA-12-4 EA-12-4 EPB-12-4 EB-12-4 12 6,3 EPA-12-6,3 EA-12-6,3 EPB-12-6,3 EB-12-6,3 12 10 EPA-12-10 EA-12-10 EPB-12-10 EB-12-10 12 16 EPA-12-16 EA-12-16 EPB-12-16 EB-12-16 12 25 EPA-12-25 EA-12-25 EPB-12-25 EB-12-25 12 31,5 EMPA-12-31,5 EMA-12-31,5 EMPB-12-31,5 EMB-12-31,5 12 40 EMPA-12-40 EMA-12-40 EMPB-12-40 EMB-12-40 12 50 EMPA-12-50 EMA-12-50 EMPB-12-50 EMB-12-50 12 63 EMPA-12-63 EMA-12-63 EMPB-12-63 EMB-12-63 12 80 EMPA-12-80 EMA-12-80 EMPB-12-80 EMB-12-80 7,2 2,5 EPA-7,2-2,5 EA-7,2-2,5 EPB-7,2-2,5 EB-7,2-2,5 7,2 4 EPA-7,2-4 EA-7,2-4 EPB-7,2-4 EB-7,2-4 7,2 6,3 EPA-7,2-6,3 EA-7,2-6,3 EPB-7,2-6,3 EB-7,2-6,3 7,2 10 EPA-7,2-10 EA-7,2-10 EPB-7,2-10 EB-7,2-10 7,2 16 EPA-7,2-16 EA-7,2-16 EPB-7,2-16 EB-7,2-16 7,2 25 EPA-7,2-25 EA-7,2-25 EPB-7,2-25 EB-7,2-25 7,2 31,5 EMPA-7,2-31,5 EMA-7,2-31,5 EMPB-7,2-31,5 EMB-7,2-31,5 7,2 40 EMPA-7,2-40 EMA-7,2-40 EMPB-7,2-40 EMB-7,2-40 7,2 50 EMPA-7,2-50 EMA-7,2-50 EMPB-7,2-50 EMB-7,2-50 7,2 63 EMPA-7,2-63 EMA-7,2-63 EMPB-7,2-63 EMB-7,2-63 7,2 80 EMPA-7,2-80 EMA-7,2-80 EMPB-7,2-80 EMB-7,2-80 EXIMPROD GRUP td BUZAU, Bistritei street, number 3 120038 ROMANIA Phone 0040 238 710 2 Fax 0040 238 710 384 office@eximprod.ro www.eximprod.ro 7