Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Similar documents
Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Data Center Continuous

Diesel generator set QSK78 series engine

Diesel generator set QSK78 series engine

Diesel generator set QST30 series engine

Rental Power QSL9 series engine

Diesel generator set QSK60 series engine

Diesel Generator set QSK50 series engine 1135 kw-1500 kw 60 Hz EPA emissions

Rental Power QSB7 series engine

Diesel generator set QSK60 series engine

Diesel Generator set QSK95 series engine

Diesel generator set QSK60 series engine

Diesel Generator set QSK95 series engine

Diesel generator set QSK60 series engine

Diesel generator set QSK50 series engine

Diesel generator set QSL9 series engine

Rental Power KTA50 G3 series engine

Diesel generator set QSX15 series engine

Diesel generator set QSK95 series engine

Tier4 certified diesel generator set QSK78 series engine

Diesel generator set QSK23 series engine

Diesel generator set 6BT5.9 series engine

Diesel generator set 4BT3.3 series engine

Diesel generator set QSB7 series engine

Tier4 certified diesel generator set QSK50 series engine

Diesel generator set QSK23 series engine

Diesel generator set QSL9-G7 series engine

Diesel generator set QSX15 series engine

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Spark-ignited generator set

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Spark-ignited generator set

Rental Power 1500 kw. Specification sheet. Description. Features. Options

Spark-ignited generator set

Diesel Generator Set S3.8 Series Engine

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Diesel generator set QSL9 series engine

Rental Power 4BTAA3.3 series engine

Rental Power 800 kw. Specification sheet. Description. Features. Options

Rental Power Kubota V2403 series engine

Model DFEH 60 Hz EPA Emissions

Diesel Generator Set Model DFJD 60 Hz

2000kW Rental Package

Diesel Generator Set Model DFBF 60 Hz

Diesel generator set C17D5T series

Diesel Generator Set Model DFCE 60 Hz

Spark-Ignited Generator Set Model GGLA 60 Hz

Diesel Generator Set Model DGDB 60 Hz

Diesel Generator Set Model DFHB 60 Hz

Gaseous Fuel Generator Set KTA19G Engine Series

Spark-Ignited Generator Set Model GGKD 60 Hz

Spark-Ignited Generator Set Model GGFD 60 Hz

Model DSHAE 60 Hz EPA Emissions

Gaseous Fuel Generator Set Model GFDA

Spark-Ignited Generator Set Model GGKC 60 Hz

Diesel Generator Set Model DSHAD 60 Hz EPA Emissions

Gaseous Fuel Generator Set QSK19G Engine Series

Model DKAC 60 Hz EPA Emissions

Model DFHD 60 Hz EPA Emissions

KTA50 Land Based Drilling Power Modules

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

55 KW / 70 KVA POWERED by

1800 KW / 2250 KVA POWERED by

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

20 KW / 25 KVA LIQUID COOLED POWERED by

2000 KW / 2500 KVA POWERED by

28 KW / 28 KVA POWERED by

640 KW / 800 KVA POWERED by

PowerCommand 1.1 control system

45 KW / 55 KVA POWERED by

2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2

80 KW / 100 KVA POWERED by

300 KW / 375 KVA POWERED by

16 KW / 20 KVA POWERED by

700 KVA / 550 KW POWERED by

130 KW / 165 KVA POWERED by

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Gaseous Fuel Generator Set GTA19 Engine Series

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

600 KW / 750 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

130 KW / 165 KVA POWERED by

500 KW / 625 KVA POWERED by

1000 KW / 1250 KVA POWERED by

19 KW / 24 KVA POWERED by

2500 Prime 2200 Continuous

Gaseous Fuel Generator Set GTA28 Engine Series

Ultra-low sulphur diesel (15 ppm sulphur)

Gaseous Fuel Generator Set GTA50 Engine Series

18 KW / 18 KVA POWERED by

55 KW / 69 KVA POWERED by

Standby Amper VOLTAGE

70 KW / 90 KVA POWERED by

60 Hz FEATURES. Exclusively from your Caterpillar dealer

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

DIESEL GENERATOR SET. 60 Hz FEATURES

60 KW / 75 KVA POWERED by

105 KW / 130 KVA. POWERED by TP-I100-T2-60. kva 130 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 125 Prime Power Factor 0.

Transcription:

Specification sheet Diesel generator set QSK78 series engine 2750kVA - 3000kVA 50 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing optimum performance, reliability, and versatility for stationary Standby, Prime Power, and Continuous duty applications. Features Cummins heavy-duty engine - Rugged 4-cycle industrial diesel delivers reliable power, low emissions and fast response to load changes. Permanent Magnet Generator (PMG) - Offers enhanced motor starting and fault clearing short circuit capability. Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing short-circuits capability, and class F or H insulation. Cooling system - Optional remote mounted cooling system, designed and tested for rated ambient temperatures, offers maximum flexibility for facility design requirements. Control system - The PowerCommand electronic control is standard equipment and provides total genset system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, AmpSentry protection, output metering, auto-shutdown at fault detection and NFPA 110 Level 1 compliance. NFPA - The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems. Warranty - Backed by a comprehensive warranty and worldwide distributor network. Model Standby rating 50 Hz kva (kw) Prime rating 50 Hz kva (kw) Continuous rating 50 Hz kva (kw) Emissions compliance EPA and TA LUFT Controller Data sheets C2750 D5 2750 (2200) 2500 (2000) 2250 (1800) 4g TA LUFT 3.3 DS352-CPGK C3000 D5 3000 (2400)* 2750 (2200) 2475 (1980) 4g TA LUFT 3.3 DS335-CPGK *Note: Rating is with a remote cooled configuration

Generator set specifications Transient performance Steady state voltage regulation, no load to full load ± 0.25% Steady state frequency variation ± 0.25% Frequency regulation EMC compatibility Engine specifications Design Bore 170 Stroke 190 ISO 8528-5 compliant Isochronous Displacement 77.6 L (4735 in 3 ) Cylinder block Battery capacity Battery charging alternator Starting voltage Fuel system Fuel filter Air cleaner type Lube oil filter type(s) Cooling system Alternator specifications Design Stator Rotor Insulation system Standard temperature rise Exciter type Phase rotation Alternator cooling Radiated emissions to BS EN61000-6.3 Conducted immunity to BS EN61000-6.2 4 cycle, V, turbocharged and low temperature after-cooled Cast iron, 18 cylinder 2200 amps 55 amps 24 volts, negative ground Direct injection: number 2 diesel fuel, fuel filter, automatic electric fuel shutoff Triple element, 10 micron filtration, spin on fuel filter with water separator Dry replaceable element Four spin-on, combination full flow and bypass filters 104 ºF (40 ºC) ambient Brushless, 4 pole, drip proof, revolving field 2/3 pitch 2 bearing, flexible coupling Class H on low and medium voltage, Class F on high voltage 150 C Standby PMG (Permanent magnet generator) A (U), B (V), C (W) Direct drive centrifugal blower fan AC waveform total harmonic distortion No load < 1.5%. Non distorting balanced linear load < 3% Telephone influence factor (TIF) Telephone harmonic factor (THF) < 2% Available voltages 50 Hz Line-Neutral/Line-Line 220/380 1905/3300 230/400 3810/6600 240/416 6350/11000 255/440 < 50 per NEMA MG1-22.43 Generator set options and accessories Engine 208/240/480 V thermo-statically controlled coolant heater for ambient above and below 4.5 C (40 F) Oil drain pump manual Engine toolkit Heavy duty air cleaner Exhaust system None supplied Residential grade exhaust silencer shipped loose Side entry silencer Control panel Multiple language support Right or left facing mounting Floor mounted 3 phase differential CTs (3x or 6x CTs) Masterless Load Demand Warning high bearing temperature Alternator temperature monitoring

Generator set options and accessories (continued) Control panel Exhaust gas temperature monitoring 6x user-configurable relays 120/240 V Heater control cabinet Mechanical hour meter 2x digital input/output Alternator 120, 240 or 110/240 V control anticondensation heater Stator winding temp sensor 2 RTDs/phase Bearing temp sensor RTDs 1 or 2 hole lug output terminal Cable entrance box set mounted top or bottom entry Cable entrance box left or right mounting Generator set 5 A or 10 A Batteries Standalone or wall mountable battery charger Manual available in multiple languages Standard spring mounts Oil sampling valve Fuel transfer pump hand or electric Free standing, single wall fuel tank 1350 L/356 US Gal Cooling system Remote radiator 50 ºC (122 ºF) radiator Slip fit connection Flanged (ASA) connection Note: Some options may not be available on all models - consult factory for availability.

PowerCommand 3.3 control system Control system The PowerCommand control system is an integrated microprocessor based generator set control system providing voltage regulation, engine protection, alternator protection, operator interface and isochronous governing. AmpSentry Includes integral AmpSentry protection, which provides a full range of alternator protection functions that are matched to the alternator provided. Power management Control function provides battery monitoring and testing features and smart starting control system. Advanced control methodology Three phase sensing, full wave rectified voltage regulation, with a PWM output for stable operation with all load types. Communications interface Control comes standard with PCCNet and Modbus interface. Regulation compliant Prototype tested: UL, CSA and CE compliant. Service - InPower PC-based service tool available for detailed diagnostics, setup, data logging and fault simulation. Reliable design The control system is designed for reliable operation in harsh environment. Multi-language support Operator panel features Operator panel features The operator panel, in addition to the alternator, displays the Utility/AC Bus data. Operator/display functions 320 x 240 pixels graphic LED backlight LCD Auto, manual, start, stop, fault reset and lamp test/panel lamp switches Alpha-numeric display with pushbuttons LED lamps indicating genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode and stop Paralleling control functions Digital frequency synchronization and voltage matching Isochronous kw and kvar load sharing controls Droop kw and kvar control Sync check Extended paralleling (Peak Shave/Base Load) Digital power transfer control (AMF) provides load transfer operation in open or closed transition or soft (ramping) transfer mode Alternator data Line-to-Neutral and Line-to-Line AC volts 3-phase AC current Frequency kw, kvar, power factor kva (three phase and total) Engine data DC voltage Engine speed Lube oil pressure and temperature Coolant temperature Comprehensive FAE data (where applicable) Other data Genset model data Start attempts, starts, running hours, kw hours Load profile (operating hours at % load in 5% increments) Fault history Data logging and fault simulation (requires InPower) Standard control functions Digital governing (optional) Integrated digital electronic isochronous governor Temperature dynamic governing Digital voltage regulation Integrated digital electronic voltage regulator 3-phase, 4-wire Line-to-Line sensing Configurable torque matching AmpSentry AC protection AmpSentry protective relay Over current and short circuit shutdown Over current warning Single and three phase fault regulation Over and under voltage shutdown Over and under frequency shutdown Overload warning with alarm contact Reverse power and reverse Var shutdown Field overload Engine protection Battery voltage monitoring, protection and testing Over speed shutdown Low oil pressure warning and shutdown High coolant temperature warning and shutdown Low coolant level warning or shutdown Low coolant temperature warning Fail to start (over crank) shutdown Fail to crank shutdown Cranking lockout Sensor failure indication Low fuel level warning or shutdown Fuel-in-rupture-basin warning or shutdown Full authority electronic engine protection Control functions Time delay start and cool down Real time clock for fault and event time stamping Exerciser clock and time of day start/stop Data logging Cycle cranking Load shed Configurable inputs and outputs (4) Remote emergency stop Options Auxiliary output relays (2)

Emergency Standby Power (ESP): Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Limited-Time Running Power (LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited-Time Running Power (LTP) is in accordance with ISO 8528. Prime Power (PRP): Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Base Load (Continuous) Power (COP): Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514. This outline drawing is for reference only. See respective model data sheet for specific model outline drawing number. See respective model data sheet for specific model outline drawing number. Do not use for installation design Weight and dimensions Model Dim A mm Dim B mm Dim C mm Set weight* dry kg Set weight* wet kg C2750 D5 5691 2305 2798 18549 19145 C3000 D5 5691 2305 2798 18964 19560 *Note: Weights represent a set with standard features. See outline drawings for weights of other configurations. Certifications This generator set is designed in facilities certified to ISO 9001 and manufactured in facilities certified to ISO 9001 or ISO 9002. This generator set is available with CE certification. This generator set has been designed to comply with ISO 8528 regulation. For more information contact your local Cummins distributor or visit 2017 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and Our energy working for you. are trademarks of Cummins Inc. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. SS27-CPGK 08/17)

2017 Cummins Inc. SS27-CPGK (07/17)