FLEXIM. Solutions for Sulphuric Acid and Oleum Producers and Demanding Industries. PIOX - The superior solution Accurate - Reliable - Safe - Efficient

Similar documents
Flow Measurement Services for the Oil & Gas, Power, Chemical and Processing Industries

FLUXUS HPI Series External Measurement of Internal Flow

REVOLUTIONIZE YOUR DENSITY AND CONCENTRATION MEASUREMENT TECHNOLOGY

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Vortex Flow Meter Model DVH

Vortex Flowmeter Model DVE

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Non-Invasive Hydrocarbon Products Mass Flow Measurement, Media Identification and Leak Detection

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Refinery Solutions FLEXIM

Reliable fluid detection with non-invasive ultrasonic measurement

Armstrong In-Line and Insertion Vortex Flow Meters

VersaFlow Vortex 100 Vortex Flow Meter Specifications

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

FLUXUS HPI Series. Non-Intrusive Ultrasonic Flow Measurement for the Hydrocarbon Processing Industries. External Measurement of Internal Flow FLEXIM

Mobrey MSM400 Ultrasonic sludge density measurement system

Rosemount 3051CFA Annubar Flowmeter

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

Range of Ultrasonic Flowmeters.

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

F-2600 SERIES INLINE VORTEX FLOW METER

VersaFlow Vortex 100 Vortex Flow Meter Specifications

ABB Instrumentation. Thermal Mass Flowmeter Sensyflow. Intelligent solutions for accurate gas mass flow measurement

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

VLM20 In-line Vortex Flowmeter

Transmitting Transducer. Gas/Air Velocity Range:

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

Tubeskin thermocouple assembly Model TC59-V

Simply a question of better measurement

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Dräger X-am 5100 Single-Gas Detection Device

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Measuring insert for resistance thermometer Model TR10-A

OPTISWIRL 4070 Technical Datasheet

Tubeskin thermocouple assembly Model TC59-V

Logix 3800 Digital Positioner

Knife gate valve TV. Data is only for informational purpose. All specifications are subject to change without notice issue 9

The readings you need, right where you need them. AX Series Vortex Meters

Product Range Valves, Measurement and Control Systems

Tubeskin thermocouple assembly Model TC59-W

High Precision Turbine Wheel Flow Meter for Liquids

F-2700 SERIES INSERTION VORTEX FLOW METER

Sampling Valves. SchuF FETTEROLF

Dräger CMS Chip Measurement System

Logix 3800 Digital Positioner

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

STEEMCO Flowmeter for Steam

COMPANY POSITIVE DISPLACEMENT FLOW METERS

The readings you need, right where you need them. AX Series Vortex Meters

Multivariable Vortex Flow Meter

FPA4 DATASHEET JUNHO 2013

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Plastic tube variable area flowmeter for liquids and gases

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Knife gate valve JTV. Data is only for informational purpose. All specifications are subject to change without notice issue 11

TORRIX Magnetostrictive level sensor

STEEMCO-MAS Flowmeter for Steam

Fisher FIELDVUE DVC6200 Series Hazardous Area Approval Nameplates

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Compressed Air-Supply Meter

Standard Product Program. AirLINE & AirLINE Quick Type 8640 & Type 8644

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

Multivariable Vortex Flow Meter

Coriolis Flow Solutions for a Global Marketplace

PROCESS INSTRUMENTATION

TOP SMART intelligent position monitor:

OPTISWIRL 4070 Technical Datasheet

F-2600 SERIES INLINE VORTEX FLOW METER

OPTIMASS 3000 Technical Datasheet

OPTIMASS 2000 Technical Datasheet

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Enhanced Classic Line (ECL) Mixers PORTABLE/FIXED MOUNT MIXERS

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

Accessories for Pressure Gauges

Jet Fuel Conductivity Analysers & Additive Management systems

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Botlek Studiegroep Basics Electro Magnetic Flowmeters

F-2700 SERIES INSERTION VORTEX FLOW METER

CML Electric Actuator for Baumann Series

replacement parts 6.1 General 6.2 Ordering

Product Data Sheet. Turbine Flow Meter. QuikSert DESCRIPTION INSTALLATION FEATURES REPAIR KITS

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Coriolis Flow Solutions for a Global Marketplace

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

MMA. Insertion Resistance Thermometers. with, or without transmitter. OEconomically-priced O thermometers with optional plug-on display

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

ViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Thermocouple with spring-loaded tip Model TC55

Flow Measurement Technology Training

Rosemount 2160 Wireless Vibrating Fork Liquid Level Switch

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Transcription:

FLEXIM More than 25 years of experience in Flow Measurement and Process Analytical Technology FLEXIM GmbH Berlin, Germany Phone: +49 30 93 66 76 60 info@flexim.de Technical Facts Configurations Fluid Concentration range 0 80 % Configuration PIOX R: PTFE Chemical Design variant Completely PTFE PTFE powder coated Stainless Steel 304 (1.4301) (Stainless Steel transmitter housing) 80 100 % PIOX S721 SA 0 40 % PIOX R: Chemical Design variant Stainless Steel 316Ti (1.4571) Stainless Steel 304 (1.4301) PIOX S721 40 100 % PIOX S721 SA (PIOX S721) Mass flow: Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Concentration: Density: ± 1.2 % of rd. ± 0.01 m/s (ext. calibr.) ± 0.5 % of rd. ± 0.01 m/s (Process calibr.) Operating temp. of media: -40 C... +200 C (up to +400 C with WaveInjector ) Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage Outputs: Many combinations available, possible types: Current (0/4 ma... 20 ma), Voltage, Frequency, Impulse, Alarm Communication protocols: HART, Modbus, Foundation Fieldbus, Profibus Transducers: IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant) Transmitters: Non-Invasive Flow and Massflow of, and Water - Acid and Strength and Density up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant) PIOX R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of (through Refractive index) 0.1 w% ; nd: 0.0002 Operating temp. (media) - 20 C... (+ 130 C) + 150 C Fluid pressure: PN 10, PN 16, on request PN 40 / Explosion protection: Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2 Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional FLEXIM Austria GmbH Olbendorf, Austria Phone: +43 33 26 529 81 office@flexim.at Drying Tower Acid Strength FLEXIM Instruments Benelux B.V. Berkel en Rodenrijs, Netherlands Phone: +31 10 24 92 333 benelux@flexim.com Flow and Acid Strength FLEXIM France SAS Limonest, France Phone: +33 4 27 46 52 10 info@flexim.fr Absorption Tower Inlet Volume Diluter Effectivity Accurate HRS Tower Concentration in Hot Acid FLEXIM Instruments UK Ltd. Northwich, UK Phone: +44 1606 781 420 sales@flexim.co.uk Waste Water Acid Strength FLEXIM Middle East Dubai, U.A.E. Phone: +971 4430 5114 salesme@flexim.com FLEXIM Instruments Asia Pte Ltd. Singapore, Singapore Phone: +65 67 94 53 25 salessg@flexim.com Direct Acid Consumption FLEXIM Instruments China Shanghai, China Phone: +86 21 64 95 75 20 shanghai@flexim.com FLEXIM S.A Santiago de Chile, Chile Phone: +56 22 32 03 62 80 info@flexim.cl FLEXIM AMERICAS Corporation New York, USA Phone: +1 63 14 92 23 00 salesus@flexim.com FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos Aires Phone: +54 11 49 20 71 00 flexim@escoarg.com.ar www.escoarg.com.ar www.flexim.com Water Balance BUSULPHURICACICV1-1EN 10/2017 Subject to change without notification! PIOX - The superior solution Accurate - Reliable - Safe - Efficient Solutions for and Producers and Demanding Industries

Tail Gas Dilute Sulfuric Acid Sulphur Acid SO3 Heat Recovery System By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX S is the ideal solution for monitoring strong sulphuric acid and oleum: Sulphur Burner The system measures sulfuric acid concentration and mass flow directly on the main production lines Converter Bed 1-3 Absorber Intermediate Absorber Converter Bed 4 PIOX R - For Concentration Monitoring of Diluted and SO3 + PIOX S Non-invasive Concentration and Mass Flow measurement of strong and PIOX R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0 80%) and (0 40%), due to its: Final Absorber Corrosion resistant carbon fibre reinforced PTFE sensor head design Product Acid Air It accurately determines the acid strength in real time The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process It significantly increases plant safety as it does not Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts Dryer require any pipe opening or welding for installation nor any additional flanges The measurement is free of wear or abrasion and thus also virtually maintenance free PIOX R PIOX S (massflow) 20-37% Tank/Storage Storage Product Acid 1 Dilution Unit Due to its patented transmitted light principle PIOX R offers a complete drift free, precise and long term stable Dilution Add Storage measurements It can never be a source for potential leaks and sub-sequent process shut-downs Precise 0 to 100% Strength and Mass Flow Measurement with PIOX 1600m/s PIOX S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium 1,450 90 C / 194 F 120 C / 284 F 1500m/s 1,390 Precise 0 to 100% Strength and Mass Flow Measurement from PIOX _ Extreme reliability due to no direct 40 C / 104 F contact with the medium 1,380 Increased plant safety and 1,350 3 4 5 6 7 8 1,340 1,330 9 10 120 C / 86 F 3 4 5 6 7 8 9 10 Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified) 1000m/s availability - no pipe works or process shut-downs required 1,360 1,370 Advantages: concentration and temperature range (up to 400 C) Loading Highest accuracy over a wide flow, 3 900m/s 800m/s 4 3 4 5 6 7 8 9 10

Tail Gas Dilute Sulfuric Acid Sulphur Acid SO3 Heat Recovery System By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX S is the ideal solution for monitoring strong sulphuric acid and oleum: Sulphur Burner The system measures sulfuric acid concentration and mass flow directly on the main production lines Converter Bed 1-3 Absorber Intermediate Absorber Converter Bed 4 PIOX R - For Concentration Monitoring of Diluted and SO3 + PIOX S Non-invasive Concentration and Mass Flow measurement of strong and PIOX R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0 80%) and (0 40%), due to its: Final Absorber Corrosion resistant carbon fibre reinforced PTFE sensor head design Product Acid Air It accurately determines the acid strength in real time The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process It significantly increases plant safety as it does not Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts Dryer require any pipe opening or welding for installation nor any additional flanges The measurement is free of wear or abrasion and thus also virtually maintenance free PIOX R PIOX S (massflow) 20-37% Tank/Storage Storage Product Acid 1 Dilution Unit Due to its patented transmitted light principle PIOX R offers a complete drift free, precise and long term stable Dilution Add Storage measurements It can never be a source for potential leaks and sub-sequent process shut-downs Precise 0 to 100% Strength and Mass Flow Measurement with PIOX 1600m/s PIOX S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium 1,450 90 C / 194 F 120 C / 284 F 1500m/s 1,390 Precise 0 to 100% Strength and Mass Flow Measurement from PIOX _ Extreme reliability due to no direct 40 C / 104 F contact with the medium 1,380 Increased plant safety and 1,350 3 4 5 6 7 8 1,340 1,330 9 10 120 C / 86 F 3 4 5 6 7 8 9 10 Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified) 1000m/s availability - no pipe works or process shut-downs required 1,360 1,370 Advantages: concentration and temperature range (up to 400 C) Loading Highest accuracy over a wide flow, 3 900m/s 800m/s 4 3 4 5 6 7 8 9 10

Tail Gas Dilute Sulfuric Acid Sulphur Acid SO3 Heat Recovery System By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX S is the ideal solution for monitoring strong sulphuric acid and oleum: Sulphur Burner The system measures sulfuric acid concentration and mass flow directly on the main production lines Converter Bed 1-3 Absorber Intermediate Absorber Converter Bed 4 PIOX R - For Concentration Monitoring of Diluted and SO3 + PIOX S Non-invasive Concentration and Mass Flow measurement of strong and PIOX R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0 80%) and (0 40%), due to its: Final Absorber Corrosion resistant carbon fibre reinforced PTFE sensor head design Product Acid Air It accurately determines the acid strength in real time The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process It significantly increases plant safety as it does not Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts Dryer require any pipe opening or welding for installation nor any additional flanges The measurement is free of wear or abrasion and thus also virtually maintenance free PIOX R PIOX S (massflow) 20-37% Tank/Storage Storage Product Acid 1 Dilution Unit Due to its patented transmitted light principle PIOX R offers a complete drift free, precise and long term stable Dilution Add Storage measurements It can never be a source for potential leaks and sub-sequent process shut-downs Precise 0 to 100% Strength and Mass Flow Measurement with PIOX 1600m/s PIOX S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium 1,450 90 C / 194 F 120 C / 284 F 1500m/s 1,390 Precise 0 to 100% Strength and Mass Flow Measurement from PIOX _ Extreme reliability due to no direct 40 C / 104 F contact with the medium 1,380 Increased plant safety and 1,350 3 4 5 6 7 8 1,340 1,330 9 10 120 C / 86 F 3 4 5 6 7 8 9 10 Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified) 1000m/s availability - no pipe works or process shut-downs required 1,360 1,370 Advantages: concentration and temperature range (up to 400 C) Loading Highest accuracy over a wide flow, 3 900m/s 800m/s 4 3 4 5 6 7 8 9 10

FLEXIM More than 25 years of experience in Flow Measurement and Process Analytical Technology FLEXIM GmbH Berlin, Germany Phone: +49 30 93 66 76 60 info@flexim.de Technical Facts Configurations Fluid Concentration range 0 80 % Configuration PIOX R: PTFE Chemical Design variant Completely PTFE PTFE powder coated Stainless Steel 304 (1.4301) (Stainless Steel transmitter housing) 80 100 % PIOX S721 SA 0 40 % PIOX R: Chemical Design variant Stainless Steel 316Ti (1.4571) Stainless Steel 304 (1.4301) PIOX S721 40 100 % PIOX S721 SA (PIOX S721) Mass flow: Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Concentration: Density: ± 1.2 % of rd. ± 0.01 m/s (ext. calibr.) ± 0.5 % of rd. ± 0.01 m/s (Process calibr.) Operating temp. of media: -40 C... +200 C (up to +400 C with WaveInjector ) Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage Outputs: Many combinations available, possible types: Current (0/4 ma... 20 ma), Voltage, Frequency, Impulse, Alarm Communication protocols: HART, Modbus, Foundation Fieldbus, Profibus Transducers: IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant) Transmitters: Non-Invasive Flow and Massflow of, and Water - Acid and Strength and Density up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant) PIOX R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of (through Refractive index) 0.1 w% ; nd: 0.0002 Operating temp. (media) - 20 C... (+ 130 C) + 150 C Fluid pressure: PN 10, PN 16, on request PN 40 / Explosion protection: Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2 Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional FLEXIM Austria GmbH Olbendorf, Austria Phone: +43 33 26 529 81 office@flexim.at Drying Tower Acid Strength FLEXIM Instruments Benelux B.V. Berkel en Rodenrijs, Netherlands Phone: +31 10 24 92 333 benelux@flexim.com Flow and Acid Strength FLEXIM France SAS Limonest, France Phone: +33 4 27 46 52 10 info@flexim.fr Absorption Tower Inlet Volume Diluter Effectivity Accurate HRS Tower Concentration in Hot Acid FLEXIM Instruments UK Ltd. Northwich, UK Phone: +44 1606 781 420 sales@flexim.co.uk Waste Water Acid Strength FLEXIM Middle East Dubai, U.A.E. Phone: +971 4430 5114 salesme@flexim.com FLEXIM Instruments Asia Pte Ltd. Singapore, Singapore Phone: +65 67 94 53 25 salessg@flexim.com Direct Acid Consumption FLEXIM Instruments China Shanghai, China Phone: +86 21 64 95 75 20 shanghai@flexim.com FLEXIM S.A Santiago de Chile, Chile Phone: +56 22 32 03 62 80 info@flexim.cl FLEXIM AMERICAS Corporation New York, USA Phone: +1 63 14 92 23 00 salesus@flexim.com FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos Aires Phone: +54 11 49 20 71 00 flexim@escoarg.com.ar www.escoarg.com.ar www.flexim.com Water Balance BUSULPHURICACICV1-1EN 10/2017 Subject to change without notification! PIOX - The superior solution Accurate - Reliable - Safe - Efficient Solutions for and Producers and Demanding Industries

FLEXIM More than 25 years of experience in Flow Measurement and Process Analytical Technology FLEXIM GmbH Berlin, Germany Phone: +49 30 93 66 76 60 info@flexim.de Technical Facts Configurations Fluid Concentration range 0 80 % Configuration PIOX R: PTFE Chemical Design variant Completely PTFE PTFE powder coated Stainless Steel 304 (1.4301) (Stainless Steel transmitter housing) 80 100 % PIOX S721 SA 0 40 % PIOX R: Chemical Design variant Stainless Steel 316Ti (1.4571) Stainless Steel 304 (1.4301) PIOX S721 40 100 % PIOX S721 SA (PIOX S721) Mass flow: Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Concentration: Density: ± 1.2 % of rd. ± 0.01 m/s (ext. calibr.) ± 0.5 % of rd. ± 0.01 m/s (Process calibr.) Operating temp. of media: -40 C... +200 C (up to +400 C with WaveInjector ) Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage Outputs: Many combinations available, possible types: Current (0/4 ma... 20 ma), Voltage, Frequency, Impulse, Alarm Communication protocols: HART, Modbus, Foundation Fieldbus, Profibus Transducers: IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant) Transmitters: Non-Invasive Flow and Massflow of, and Water - Acid and Strength and Density up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant) PIOX R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of (through Refractive index) 0.1 w% ; nd: 0.0002 Operating temp. (media) - 20 C... (+ 130 C) + 150 C Fluid pressure: PN 10, PN 16, on request PN 40 / Explosion protection: Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2 Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional FLEXIM Austria GmbH Olbendorf, Austria Phone: +43 33 26 529 81 office@flexim.at Drying Tower Acid Strength FLEXIM Instruments Benelux B.V. Berkel en Rodenrijs, Netherlands Phone: +31 10 24 92 333 benelux@flexim.com Flow and Acid Strength FLEXIM France SAS Limonest, France Phone: +33 4 27 46 52 10 info@flexim.fr Absorption Tower Inlet Volume Diluter Effectivity Accurate HRS Tower Concentration in Hot Acid FLEXIM Instruments UK Ltd. Northwich, UK Phone: +44 1606 781 420 sales@flexim.co.uk Waste Water Acid Strength FLEXIM Middle East Dubai, U.A.E. Phone: +971 4430 5114 salesme@flexim.com FLEXIM Instruments Asia Pte Ltd. Singapore, Singapore Phone: +65 67 94 53 25 salessg@flexim.com Direct Acid Consumption FLEXIM Instruments China Shanghai, China Phone: +86 21 64 95 75 20 shanghai@flexim.com FLEXIM S.A Santiago de Chile, Chile Phone: +56 22 32 03 62 80 info@flexim.cl FLEXIM AMERICAS Corporation New York, USA Phone: +1 63 14 92 23 00 salesus@flexim.com FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos Aires Phone: +54 11 49 20 71 00 flexim@escoarg.com.ar www.escoarg.com.ar www.flexim.com Water Balance BUSULPHURICACICV1-1EN 10/2017 Subject to change without notification! PIOX - The superior solution Accurate - Reliable - Safe - Efficient Solutions for and Producers and Demanding Industries