Miniature Intermediate Power Relay HY A switching capabilities (C, C).kV dielectric strength (between coil and contacts) Various terminals, test button available Different sockets available to pole configurations Outline dimensions: 8 x. x.0 mm Options and Ordering Codes HY PN DC Contact arrangement Pole CO Pole CO Pole CO PN Coil voltage Mechanical indicator /test latch LED Mounting Plug-in PCB XN PX XX Mechanical indicator Test latch and flag No indication or test Contact Data Contact arrangement C, C C Contact resistance 00mΩ (at A VDC) Contact material Silver Alloy Contact Rating A 0VAC / 0VDC A 0VAC / 0VDC Max. switching voltage 0VAC / 0VDC Max. switching current A A Max. switching power 0W 0W 0VA 0VA Mechanical Life x0 OPS Electrical Life x0 OPS Initial Insulation Resistance 000MΩ (at 00VAC) Between coil & contacts 00VAC min. Dielectric Strength Between open contacts 000VAC min. Between contact sets 00VAC min. Operate time (at nomi. Volt) ms max. Release time (at nomi. Volt) ms max. Shock resistance Functional 98m/s² Destructive 980m/s² Vibration resistance 0 to Hz mm DA -0 C to +0 C Humidity 9% RH, 0 C Termination PCB, Plug-in Unit Weight Approx g Construction Dust protected Coil Data Nominal Voltage VDC Coil Coil power Safety Approval Ratings UL/CUL Pick-up Voltage VDC Drop-out Voltage VDC DC type 0.9W to.w AC type PCO PCO PCO Max. Allowable Voltage VDC.VA to.8va Coil Resistance Ω 0... ( ± 0%).8 0.. 0 ( ± 0%) 9... 0 ( ± 0%) 9... 0 ( ± 0%) 8 8..8.8 00 ( ± %) 0 88 000 ( ± %) Nominal Voltage VAC Pick-up Voltage VAC Drop-out Voltage VAC Max. Allowable Voltage VAC Coil Resistance Ω.8.8.. ( ± 0%) 9... ( ± 0%) 9... 8 ( ± 0%) 8 8...8 ( ± 0%) 0 9 0 ( ± %) 0 00 ( ± %) A 0VAC / 0VDC A 0VAC / 0VDC at C
Miniature Intermediate Power Relay HY Outline dimensions (mm) and Poles Plug-in PCB No pins on pole. No pins These on pins pole. are only These on pins pole. are only on pole. No pins on pole. No pins These on pole. pins are only These pins are only on pole. on pole. Poles Plug-in PCB PCB Layout Pole CO Pole CO Pole CO
Miniature Intermediate Power Relay HY Wiring diagram Pole CO Pole CO Pole CO Pole CO (With LED) Pole CO (With LED) Pole CO (With LED) Curve Maximum Switching Power (, pole CO) Maximum Switching Power ( pole CO)
SRN-D Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring Stew Torque Wire strip length -0 to 0 C 00VAC A (Per pole) >KV IP0 Self-extinguishing-PA+GF (V0) QSn.-0. Plastic 0.Nm mm Mounting dimension Inter connection Retainer dimension.. 8.... 9..9 R -M SRN-S Panel mount or mm Din Rail (EN00) Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring Stew Torque Wire Strip length -0 to 0 C 00VAC A (Per pole) >KV IP0 Self-extinguishing-PA+GF (V0) QSn.-0. Plastic 0.Nm mm Mounting dimension Inter connection Retainer dimension 0.8.. 9 COM 8 NO. NC....9 R 9. A A COIL SRN-D/0/0 SRN-S/0/0
SRN-C Panel mount or mm Din Rail (EN00) Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Stew Torque Wire strip -0 to 0 C 00VAC A (Per pole) >KV IP0 Self-extinguishing-PA+GF (V0) QSn.-0. 0.Nm mm Mounting dimension Inter connection SRH-C/0/08 SRNC/0/08
General Purpose Power Relay QY General purpose 0 amp Power Relay available in and PCO Plug-in, PCB, chassis mount and Flange Arc barriers prevent flashover between contacts High reliability/long life expectancy UL/cUL approved RoHS Approved Options and ordering codes QY XXF 0VAC General purpose power relay For coil voltage see table Contact Form pole changeover pole changeover Plug-in Printed circuit board XX F XN Clear case Flange cover LED Only Specification Contact arrangement C C Contact Resistance 00m (at A VDC) Contact material Contact rating (res, load) Max. switching voltage Silver alloy C: A 0VAC/0VDC C: 0A 0VAC/0VDC 0VAC/0VDC Max. switching current A 0A Max. switching power 0VAC/0W 00VAC/80W Mechanical endurance Electrical endurance Coil Data Rated Voltage 0 0 AC Coils. Coil resistance 8 0 00 x 0 OPS x 0 OPS (See approval reports for detals) DC Coils. Coil resistance 0 0 000 - Initial Insulation Resistance 00M @ 00VDC Dielectric Strength Between coil & contact Between open contacts Between contact sets Operate time (at nomi. voltage) Release time (at nomi. voltage) Temperature rise (at nomi. voltage) 00VAC min. 000VAC min. 00VAC min. ms ms 0K max. Shock Functional 00m/s resistance Destructive 000m/s Vibration resistance Humidity Termination Unit Weight Construction Safety Approval Ratings UL&CUR TÜV mm DA, 0 to Hz 98%, +0 C -0 C to +0 C PCB, Plug-in Approx. g Dust protected Form C: A 0VAC/0VDC Form C: 0A 0VAC/0VDC /HP 0VAC/0VAC C: 0A 0VAC/0VDC QY/0/0
General Purpose Power Relay QY Outline dimensions Wiring diagram and PC Board layout. 0 DIN Socket SRH-C 8 0.... 0... 8.. Terminal arrangement. 0.. 0. 8. 0. 8.. PCB layout... 0 0.. ø.-8 0... 0... Characteristic Curve MAXIMUM SWITCHING POWER(C) MAXIMUM SWITCHING POWER(C) Contact Current (A) 0 0. DC resistive load AC resistive load Contact Current (A) 0 0. DC resistive load AC resistive load 0. 0. 0 0 00 00 0 0 00 00 Contact Voltage (V) Contact Voltage (V) QY/0/0
SRH-C Panel mount or mm Din Rail (EN00) Rated voltage Rated current Insulation voltage Protection degree Socket material Contacts spring material Hold down spring Stew Torque Wire Strip length -0 to 0 C 00VAC A (Per pole) >KV IP0 Self-extinguishing-PA+GF (V0) QSn.-0. Steel.0Nm mm Mounting dimension Inter connection Retainer dimension. -.x 8-M.x8 -ø... 8.max 8 8. 0. 0 max 8 8.max 9.. +0. -0. SRH-C/0/08 SRNC/0/08