Airmatic Lubricator Pneumatic Operation, Oil General The Airmatic lubricator is a simple economical unit with a broad range of output. It is designed to be operated with shop air. The stroke setting is easily adjusted to suit a wide variety of industrial centralized lubrication needs. The package can be supplied with either a, 4 or liter reservoir. Application The Airmatic lubricator is for use with cyclic oil lubrication systems. The unit can be used with single line resistance (SLR), positive displacement injector (PDI), progressive distribution and injector systems.* Operation Airmatic lubricator includes an air actuated, spring return piston pump with an adjustable output between to 0 ccm for each piston stroke at discharge pressures up to 35 bar. Oil output is related to piston travel and cycles per unit time. Stroke movement is preset to a fixed discharge and supply air pressure governs the output delivery pressure. When used with positive displacement injectors, a built-in pressure relief device lets the PDI reset after discharge. *Refer to appropriate engineering manuals for normal system limitations when sizing distribution proportioning devices for use at a particular discharge setting. For extended service, incoming air must be dry. Always use a suitable FRL unit (filter/regulator/ lubricator) to control air to recommended operating range. Normally, the air-operated Airmatic is used with a 3/-way electrical solenoid valve (optional) to control and vent shop air from the pump air inlet. All models are available with optional 3/-way valve. To adjust lubricant delivery, loosen locknut on hex socket adjusting screw (see Figure on right). Turn delivery adjusting screw clockwise to reduse discharge use graduated label as guide, set to desired setting and tighten locknut (insert shows setting at 8 ccm). For PDI systems, maximum discharge of 0 ccm/stroke is recommended. Technical Data Delivery Volume ccm to 0 ccm/actuation cycle (infinite adjustment) Viscosity Range 30-800 cst Normal Range Cycle up to 30 cycles/minute maximum Operating Temperature 0 C to 49 C Oil Outlet Connection /8 NPTF (female) Low Level Switch 0. amp at 0 V AC Solenoid Valve 0. amp at 0 V AC Lubricator Air Connection (without solenoid) /4 NPTF (female) Operating Pressure bar SLR & PRG 8 bar PDI & INJ Recommended Incoming Air Pressure 5.5 bar SLR & PRG bar PDI & INJ Air/oil Pressure Ratio : 4 Maximum Inlet Pressure 8.5 bar Minimum Inlet Pressure 5 bar Viscosity range at operating temperature may be restricted by internal relief valve (consult BIJUR DELIMON). System parameters may affect this rate (consult BIJUR DELIMON). Figure : Lubricant Delivery Adjustment
System Design If the distribution system incorporates extensive use of flexible lines, a slightly larger discharge must be used to compensate for the resiliency of the flexible connections. Solve for the following R value and ADD this amount to the required pump discharge: + R =.030 x feet of 5/6 O.D. flexible hose + R =.035 x feet of /6 O.D. flexible hose How to Order AIR Reservoir Capacity liter plastic reservoir 4 4 liter plastic reservoir liter metal reservoir Output Mode (System Type) A SLR (single line resistance) B PDI (positive displacement injector) C Progressive (sequential movement) D Injector Level Switch A Without level switch B With level switch Solenoid Valve A No solenoid B 0V solenoid C 0V solenoid F 0V solenoid, with DIN connector G 0V solenoid, with DIN connector H 4VDC solenoid J VDC solenoid K 4VDC solenoid, with DIN connector *NOTE: System type D is for type ZE-E injectors Example: liter unit for SLR system without switch and solenoid, use Part #AIRAAA. liter unit for SLR system without switch and solenoid, use Part #AIRAAA. Several options are available in this configuration. It is necessary to choose the proper prefix letters for the particular type of unit required. Designation of lubricator is AIR, followed by a four part code, specifying reservoir size and pump options required. After the letters AIR, insert code for reservoir capacity. The third letter designation identifies the lubricator to be used for output mode (system type). Select the correct designation for lubricator unit to service the appropriate distribution system. Specify whether a low oil level switch is required by designating appropriate letter code in the fourth letter designation. Solenoid valve selection is last designation. If required, select prefix for solenoid valve by voltage.
Service Parts- Liter Model Item Part # Description B08- Cap B89 Gasket 3 HF05C Cap 4 9030 Strainer 5 D38 Reservoir assembly 6 B60-5 Level switch (closes at low level) 0034 Retainer 8 05- Nut (4x) 9 A384 Support (*) 0 A3848 Screen (*) A3899 Ring (*) A3843 Clamp (*) 3 B390 Check valve 4 B6086 Adapter 5 900- Tubing 6 900- Tubing assembly 036- Valve assembly** 8 03- Solenoid valve 0 VAC 03- Solenoid valve 0 VAC 03-3 Solenoid valve 0 VAC w/din conn. 03-4 Solenoid valve 0 VAC w/din conn. 03-5 Solenoid valve 4 VDC 03-6 Solenoid valve VDC 03- Solenoid valve 4 VDC w/din Conn 9 A439-M Muffler filter * = Available in Kit #A093 4 3 4 5 6 SEE VIEW A OR B 8 9 0 VIEW A SLR & PROGRESSIVE MODELS 0 5 3 4 VIEW B PDI MODELS & INJ MODELS 6 45 **For Injector System, this item is replaced by P/N A409 VIEW C SOLENOID VALVE 8 SHOWN WITH DIN CONNECTOR 9 3
Service Parts- 4 Liter Model Item Part # Description Reservoir assembly 0663-6KIT (Reservoir, gasket, & screws) 3 B08- Cover 4 HF05C Cap 5 9030 Strainer 6 A384 Support (*) A3848 Screen (*) 8 A3899 Ring (*) 9 A3843 Clamp (*) 0 B390 Check Valve 036 Quick dump valve assembly** 03- Solenoid valve 0 VAC 03- Solenoid valve 0 VAC 03-3 Solenoid valve 0 VAC w/din conn. 03-4 Solenoid valve 0 VAC w/din conn. 03-5 Solenoid valve 4 VDC 03-6 Solenoid valve VDC 03- Solenoid valve 4 VDC w/din conn. 3 A439-M Muffler filter * = Available in Kit #A093 = See note on reservoir SEE VIEW C VIEW A SLR & PROGRESSIVE MODELS 0 SEE VIEW A OR B 4 5 3 6 8 9 RESERVOIR NOTE: 4 Liter Airmatic Pumps with a date code previous to VW used mounting screw design reservoir; p.n. D3845. New design is a 4 mounting screw reservoir; p.n. 0663-6KIT. VIEW B PDI MODELS & INJ MODELS **For Injector System, this item is replaced by P/N A409 VIEW C SOLENOID VALVE 3 SHOWN WITH DIN CONNECTOR 4
Service Parts- Liter Model Item Part # Description B984 Filler cap 66 Strainer 3 B08- Cover 4 93 Sight gauge 5 B960 Plug 6 H043 O-ring 9846- Reservoir 8 A384 Support (*) 9 A3848 Screen (*) 0 A3899 Ring (*) A3843 Clamp (*) B390 Check valve 3 036 Quick dump valve assembly** 4 03- Solenoid valve 0 VAC 03- Solenoid valve 0 VAC 03-3 Solenoid valve 0 VAC w/din conn. 03-4 Solenoid valve 0 VAC w/din conn. 03-5 Solenoid valve 4 VDC 03-6 Solenoid valve VDC 03- Solenoid valve 4 VDC w/din conn. 5 A439-M Muffler filter * = Available in Kit #A093 3.3 SEE VIEW A OR B 4 8 9 0 5 6 VIEW A SLR & PROGRESSIVE MODELS VIEW B PDI MODELS & INJ MODELS VIEW C SOLENOID VALVE 5 4 3 **For Injector System, this item is replaced by P/N A409 SHOWN w/ DIN CONNECTOR 5
Dimensional Schematics Liter Model (PDI Version Shown) Measurements shown in mm. 66 /8 NPTF OIL OUTLET 3 CONDUIT CONNECTION FOR OPTIONAL LOW LEVEL SWITCH 46 Ø 8 THRU STROKE ADJUSTMENT: REMOVE PROTECTIVE CAP, LOOSEN LOCKNUT, TURN SCREW IN TO DECREASE PUMP OUTPUT PER STROKE, BACK SCREW OUT TO INCREASE. PUMP IS AT FULL STROKE WHEN DIMENSION A EQUALS 5 MM, USE 5/3 ALLEN WRENCH Stroke Adjustment Settings A 5.0cc 3.0cc.0cc Airmatic Bijur Lubr 30 MAX LUBRICATING SYSTEMS 80 For service call: USA -80-44-4 EUROPE 33--69.9.85.85 www.bijurdelimon.com 6 MIN 45 6
Dimensional Schematics Measurements shown in mm. 4 Liter Model 4 Air Inlet (/4 NPT) 6 Oil Outlet (/8 NPT) Electrical Encosure Filler Cap Oil Delivery Adjuster Level Switch ( 88 ) Reservoir P/N 0663-6 Dump Valve Pressure Release Valve Mounting Hole Dimensions 9 3 3 88 4
Dimensional Schematics Liter Model Measurements shown in mm. SOLENOID VALVE INCLUDED ONLY WITH MODELS AIRXXB, THRU AIRXXK (INCLUSIVE) AIR SUPPLY CONNECTION /8 NPT (W/ S. V.) OIL DISCHARGE ADJUSTMENT (PER CYCLE) 59 4 08 0 ELECTRICAL POWER SUPPLY / NPS CONDUIT CONNECTION AIR SUPPLY CONNECTION /4 NPT (W/O S. V.) (ALTERNATE CONNECTION) 06 46 9 3 3-WAY SOLENOID VALVE 54 AIR EXHAUST CONDUIT CONNECTION / NPS THREAD 4X /8 NPTF OIL DISCHARGE CONNECTION DRAIN PLUG /8 NPTF OIL DISCHARGE CONNECTION LEVEL SWITCH & JUNCTION BOX INCLUDED ONLY WITH MODELS AIRXBX 56 30 49 8