Quick Start Guide of CV50- ControlVIT Series

Similar documents
GS2 Series - Introduction

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

VFD E Series. Features

SD1 Series General Purpose AC Variable Speed Drives

Technical Explanation for Inverters

User Manual. V6/V5 T T8 Tension Control Inverter

Shenzhen Sine Electric Co., Ltd.

Technical Information

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

Tension Control Inverter

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

J1000. Compact Inverter Series.

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader

TRIPS AND FAULT FINDING

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults

L300P Inverter Specifications

Description 1/8-7.5HP

Start-up guide of LSLV-M100

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

EMHEATER. Solar Pumping Inverter User Manual. China EM Technology Limited. China EM Technology Limited. EM-GJ Intelligent Soft Starter Catalogue

V1000. Inverter Series.

V1000 Inverter Series

VLT AutomationDrive for marine winch applications

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

SJ300 Inverter Specifications

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

Sensorless Vector Drives

HIGH PERFORMANCE VECTOR CONTROL DRIVE

Names and Functions of Driver Parts

SYSDrive Frequency Inverter

Overvoltage Suppression F7 Drive Software Technical Manual

Continental Hydraulics Installation Manual CEM-AA-A

VSD Series II Variable Speed Micro Drives

AC drive has detected too high a Check loading

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

MULTI LANGUAGE KEYPAD

Troubleshooting. YASKAWA ELECTRIC SIEP C D YASKAWA AC Drive A1000 Technical Manual 301

CRANE FUNCTION MANUAL. FR-A (0.4K) to 04750(90K)-CRN FR-A (0.4K) to 06830(280K)-CRN FR-A (315K) to 12120(500K)-CRN

ADJUSTABLE FREQUENCY CRANE CONTROLS

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

KNC-SRV-FD123-EA-000 Series Servo Driver

DYNEO Synchronous motors with permanent magnets-drive Commissioning

Varispeed J7 CIMR-J7AZ. System configuration

SINAMICS GM150 IGCT version

Application Note CTAN #234

USERS MANUAL MCD REMOTE OPERATOR

Delta Products VFD CP2000 Bypass Control Packages.

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

Kelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual

MaxPak Plus Analog DC V S Drive

General Specifications

List of Tables: Page # Table 1: Emerson Commander SK VFD parameter settings 2. Table 2: Allen Bradly Power Flex 4M VFD parameter settings 3

MRL Manual Control box with Yaskawa L1000

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

ALTIVAR 18 AC Drives. File 8805

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

The IMPULSE Series 2 Crane Controls are ideal for use with inexpensive, NEMA A or B single-speed, squirrel cage induction motors.

CIMR-V7AZ Varispeed V7

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

PKS-FD Servo System

KNC-SRV-FD123-CA-000 Series Servo Driver

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

HIB Enclosed Inverter User Guide

NEW! Complete IMPULSE Control Panels Available

KNC-PKS-FD S-AAK-DKH

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

Frequency inverters overview

Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls

S100 series high performance VC control Frequency Inverter

P-SERIES VFD WITH BYPASS

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

MANUAL. MiniMax V / VK

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

Proportional directional valve, direct operated, with pq functionality

RVS-DN Digital Reduced Voltage Motor Starter

INVERTER FR-A800 Plus

LIFT INVERTER SERIES L1000A

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

MV100 Series Compact Vector Control Drive Quick Start and Installation Manual

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

PowerFlex AC Drives Portfolio

V1000 DE ES FR IT V1000 V1000 V1000 V1000

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

Constant torque, Constant power, Torque boost Six selectable pre-set patterns

Transcription:

❶ Safety precautions Do not refit the inverter unauthorizedly; otherwise fire, electric shock or other injury may occur. Please install the inverter on fire-retardant material and keep the inverter away from combustible materials. Connect the braking optional parts according to the wiring diagram. Do not operate on the inverter if there is any damage or components loss to the inverter. Do not touch the inverter with wet items or body, otherwise electric shock may occur. Only qualified electricians are allowed to operate on the inverter. Do not carry out any wiring and inspection or changing components when the power supply is applied. Ensure all input power supply is disconnected before wiring and checking and always wait for at least the time designated on the inverter or until the DC bus voltage is less than 36V. Below is the table of the waiting time: 3PH 400V Inverter module 1.5kW-110kW Minimum waiting time 5 minutes 132 kw-315 kw 15 minutes above 350 kw 25 minutes ❷ Type designation key CV50 110 4F 1 2 34 Key No. Detailed description Detailed content Product 1 Model of the inverter CV50 Inverter Rated power 2 Power range 110: 11Kw/15kW constant torque/variable 220: 22Kw/30kW constant torque/variable 1100: 110kW/132kW ctt torque/var torque Voltage degree 3 Voltage degree 4: AC 3PH 380V(-15%)~440V(+10%) EMC Filter 4 Embedded EMC Filter F indicates that the inverter has an embedded EMC Filter Category C3 ❸ Standard wiring 3.1 Main circuit Terminal Description Terminal 30kW 37kW R, S, T Power input of the main circuit U, V, W The inverter output 3-phase AC input terminals which are generally connected with the power supply. 3-phase AC output terminals which are generally connected with the. This terminal is P1 DC reactor terminal 1 inexistent P1 and (+) are connected with the terminals (+) Braking resistor DC reactor terminal 2, of DC reactor. terminal 1 braking unit terminal 1 (+) and (-) are connected with the terminals (-) / Braking unit terminal 2 PB and (+) are connected with the terminals of braking unit. PB Braking resistor terminal 2 This terminal is inexistent. of braking resistor. PE 400V: the grounding resistor is less than 10Ohm Protective grounding terminals, every machine is provided 2 PE terminals as the standard configuration. These terminals should be grounded with proper techniques. Note: Do not use an asymmetrically constructed cable. If there is a symmetrically constructed grounding conductor in the cable in addition to the conductive shield, connect the grounding conductor to the grounding terminal at the inverter and ends. Braking resistor, braking unit and DC reactor are optional parts. Route the cable, input power cable and control cables separately. 3.2 Control circuit 1/5

Terminals of control circuit Terminal Description name +10V Local power supply +10V AI2 1. Input range. AI2 voltage and current can be chosen: 0~10V/0~20mA (AI2 can be shifted by J4) AI3:-10V~+10V 2. Input impedance: voltage input: 20kΩ; current input: 500Ω AI3 3. Resolution: the minimum one is 5mV when 10V corresponds to 50 4. Deviation ±1%, 25 GND +10V reference null potential AO1 1. Output range:0~10v or 0~20mA; AO1 can be shifted by J1; AO2 can be shifted by J2 AO2 2. Deviation±1%,25 RO1A RO1 relay output, RO1A NO, RO1B NC, RO1C common terminal RO1B Contactor capability: 3A/AC250V,1A/DC30V RO1C RO2A RO2 relay output, RO2A NO, RO2B NC, RO2C common terminal RO2B Contactor capability: 3A/AC250V,1A/DC30V RO2C PE Grounding terminal Provide the input switch working power supply from external to internal. PW Voltage range: 12~24V 24V The inverter provides the power supply for users with a maximum output current of 200mA 1. Internal impedance: 3.3kΩ 2. 12~30V voltage input is available 3. The terminal is the dual-direction input terminal supporting both S1~S8 Switch input 1~8 NPN and PNP 4. Max input : 1k 5. All are programmable digital input terminal. User can set the terminal function through function s. This terminal can be used as high input channel. Max. input : 50k HDO 1. Switch input: 200mA/30V 2. Output range: 0~50k COM +24V common terminal CME Common terminal of HDO and Y1, short-connected with COM in factory Y1 1.Switch capability: 200mA/30V 2. Output range: 0~1k 485+ 485-485 communication interface and 485 differential signal interface If it is the standard 485 communication interface, please use twisted pairs or shielded cable. ❹ Diagram of quick start-up ❺ Parameters setting : means the set of the parameter can be modified on stop and running state; : means the set of the parameter can not be modified on the running state; : means the of the parameter is the real detection which can not be modified. Note: Automatic check constraints are available to avoid errors for the modifying of the parameters. P00.00 Speed control mode P00.01 Run command channel P00 Group Basic function group 1: Sensorless vector control mode 1 2: SVPWM control 2 0:Keypad running command channel 1:Terminal running command channel 2:Communication running command channel P00.02 Communication 0: MODBUS communication P00.03 Max. output P00.04~400.00 P00.04 P00.05 Upper limit of the running P00.05~P00.03 (Max. output ) Lower limit of the running 0.00~P00.04 (Upper limit of the 0.00 running ) P00.06 A command 0:Keypad data setting P00.07 B command 1:Analog AI1 setting 2:Analog AI2 setting 3:Analog AI3 setting 4:High-speed pulse setting 5:Simple PLC program setting 6: Multi-step speed running setting 7: PID control setting 8:MODBUS communication setting 2 P00.08 P00.09 B command reference 0:Maximum output 1: A command Combination of the setting 0: A 1: B 2: A+B source 3: A-B 4: Max (A, B) 5: Min (A, B) P00.10 Keypad set 0.00 ~P00.03(the Max. ) P00.11 ACC time 1 Depend 0.0~3600.0s P00.12 DEC time 1 on model 0: Runs at the default direction P00.13 Running direction 1: Runs at the opposite direction 2: Forbid to run in reverse direction P00.14 Carrier setting 1.0~15.0k Depend on model 0:No operation P00.15 3:Static autotuning 2 Motor parameter 1:Rotation autotuning autotuning 2:Static autotuning 1 0:Invalid P00.16 AVR function 1:Valid during the whole procedure 1 2 / 5 EL088A01

P00.17 Inverter type 0: Contant Torque load 1: Variable Torque load 0:No operation P00.18 1:Restore the default restore parameter 2:Clear fault records P01 Group Start-up and stop control 0:Start-up directly 1:Start-up after P01.00 Start mode DC braking 2: Start-up after speed tracking Starting of direct P01.01 0.00~ 0.50 start Retention time of the P01.02 0.0~50.0s 0.0s starting The braking current before P01.03 0.0% starting The setting range of P01.03: 0.0~100.0% The braking time before The setting range of P01.04: 0.00~s P01.04 0.00s starting 0: Linear type P01.05 ACC/DEC 1: S curve ACC time of the starting P01.06 0.1s step of S curve 0.0~50.0s DEC time of the ending P01.07 0.1s step of S curve 0: Decelerate to stop 1: Coast P01.08 Stop mode to stop Starting of DC P01.09 Setting range of P01.09: 0.00~P00.03 0.00 braking (the Max. ) Waiting time before DC P01.10 Setting range of P01.10: 0.00~s 0.00s braking Setting range of P01.11: 0.0~100.0% P01.11 DC braking current 0.0% Setting range of P01.12: 0.00~s P01.12 DC braking time 0.00s P01.13 P01.14 Dead time of FWD/REV rotation 0.0~3600.0s 0.0s 0:Switch after 0 Shifting between FWD/REV rotation 1:Switch after the starting 2:Switch after the stopping speed P01.15 Stopping speed 0.00~100.00 0.50 0: Detect according to speed setting (no P01.16 Detection of stopping stopping delay) speed 1: Detect according to speed feedback 1 (only valid for vector control) P01.17 Detection time of the 0.00~100.00s (only valid when feedback speed P01.16=1) 0.50s P01.18 0: The terminal running command is when powering on. Operation protection invalid when powering on. during powering on 1: The terminal running command is valid Action 0: Run at the lower limit (operation 1: Stop P01.19 <lower 2: Hibernation limit and valid when the lower limit >0) P01.20 Hibernation restore delay Setting range: 0.0~3600.0s(valid when time P01.19=2) 0.0s 0: Disable P01.21 Restart after power off 1: Enable P01.22 The waiting time of restart after power off 0.0~3600.0s(valid when P01.21=1) 1.0s P01.23 Start delay time 0.0~60.0s 0.0s P01.24 Delay time of the stop speed 0.0~100.0 s 0.0s 0: Output without voltage 1: Output P01.25 0 output with voltage 2: Output at the DC braking current 0 P02 Group Motor P02.01 Rated power of 0.1~3000.0kW Depends on model P02.02 Rated of 0.01~P00.03 (the Max. ) P02.03 Rated speed of 1~36000rpm P02.04 Rated voltage of 0~1200V P02.05 Rated current of 0.8~6000.0A P02.06 Stator resistor of 0.001~65.535Ω P02.07 Rotor resistor of 0.001~65.535Ω Depends P02.08 Leakage inductance of 0.1~6553.5mH on model Mutual P02.09 inductance of 0.1~6553.5mH Non-load current of P02.10 0.1~6553.5A P02.26 Motor overload protection P02.27 P02.28 P03.00 Motor overload protection coefficient Correction coefficient of power Speed loop proportional gain1 0: No protection 1: Common (with low speed compensation). 2: Variable (without low speed compensation) Times of overload M = Iout/(In*K) Setting range: 20.0%~120.0% 0.00~3.00 P03 Group Only impact the displaying Vector control The setting range of P03.00:0~200.0 The setting range of P03.01: 2 100.0% 1.00 20. P03.01 Speed loop integral time1 0.000~10.000s 0.200s Low switching The setting range of P03.02: P03.02 Speed loop proportional 0.00~P03.05 The setting range of P03.03: 0~200.0 5.00 P03.03 gain 2 The setting range of P03.04: 20. P03.04 Speed loop integral time 2 0.000~10.000s 0.200s The setting range of P03.05: P03.05 High switching P03.02~P00.03 (the Max. output ) 10.00 P03.06 Speed loop output filter 0~8 (corresponds to 0~2 8 /10ms) P03.07 P03.08 P03.09 P03.10 of electro motion slip of braking slip Current loop percentage coefficient P Current loop integral coefficient 1 P03.11 Torque setting method P03.12 Keypad setting torque 50~200% 0~65535 0: Torque control is invalid 1: Keypad setting torque (P03.12) 2: Analog AI1 setting torque (potentiometer) 3: Analog AI2 setting torque 4: Analog AI3 setting torque 5: Pulse setting torque 6: Multi-step torque setting 7: MODBUS communication setting torque -300.0%~300.0% (rated current of the ) 100% 100% 100 100 50.0% P03.13 Torque reference filter time 0.000~10.000s 0.010s Upper of forward 0:Keypad 1: AI1 2: AI2 3: AI3 P03.14 rotation in vector control 4:Pulse setting upper-limit Upper of reverse 5:Multi-step setting upper-limit P03.15 rotation in vector control 6:MODBUS communication setting upper-limit P03.16 P03.17 P03.18 P03.19 P03.20 P03.21 P03.22 Keypad setting for upper of forward rotation 0.00 ~P00.03 (the Max. output Keypad setting for upper of reverse rotation Upper electro motion torque source Upper braking torque source ) 0:Keypad setting upper-limit 1: AI1 2: AI2 3: AI3 4: 5:MODBUS communication Keypad setting of electromotion torque 0.0~300.0% ( rated current) 180.0% Keypad setting of braking torque Weakening coefficient in constant power zone The setting range of P03.22:0.1~2.0 Lowest weakening point in The setting range of P03.23:10%~100% P03.23 constant power zone 180.0% 0.3 20% P03.24 Max. voltage limit 0.0~120.0% 100.0% P03.25 Pre-exciting time 0.000~10.000s 0.300s P03.26 Weak magnetic proportional gain P03.27 Vector control speed P03.28 P03.29 of static friction of dynamic friction P04.00 Motor V/F curve setting 0~8000 100 0: Display the actual 1: Display the setting 0.0~100.0% 0.0% 0.0~100.0% 0.0% P04 Group SVPWM control 0: Straight line V/F curve 1: Multi-dots V/F curve 2: 1.3 th power low torque V/F curve 3: 1.7 th power low torque V/F curve 4: 2.0 th power low torque V/F curve 5: Customized V/F (V/F separation) 3 / 5 EL088A01

P04.01 Motor torque boost (automatic) 0.1%~10.0% 0.0% P04.02 Motor torque boost close 0.0%~50.0% 20.0% P04.03 V/F 1 of 0.00~P04.05 0.00 P04.04 V/F voltage 1 of 0.0%~110.0% 00.0% P04.05 V/F 2 of P04.03~ P04.07 00.00 P04.06 V/F voltage 2 of 0.0%~110.0% (the rated voltage of 1) 00.0% P04.07 V/F 3 of P04.05~ P02.02 (the rated of 1) 00.00 P04.08 V/F voltage 3 of 0.0%~110.0% (the rated voltage of 1) 00.0% V/F slip compensation gain P04.09 0.0~200.0% of 100.0% P04.10 P04.11 P04.12 P04.26 Motor low vibration control factor 0~100 1 Motor high vibration control factor 0~100 1 Motor vibration control threshold 0.00~P00.03 (the Max. ) 30.00 Energy-saving operation 0:No action 1:Automatic energy-saving operation 0: Keypad setting voltage 1: AI1 setting voltage 2: AI2 setting voltage; 3: AI3 setting voltage; P04.27 Voltage setting channel 4: setting voltage; 5: Multi-step speed setting voltage; 6: PID setting voltage; 7: MODBUS communication setting voltage; P04.28 Keypad setting voltage 0.0%~100.0% 100.0% P04.29 Voltage increasing time 5.0s 0.0~3600.0s P04.30 Voltage decreasing time 5.0s P04.32~100.0% P04.31 Maximum output voltage (the rated voltage of the ) 100.0% 0.0%~ P04.31 P04.32 Minimum output voltage (the rated voltage of the ) 0.0% Weaking coefficient at P04.33 constant power 1.00~1.30 1.00 P05 Group Input terminals P05.00 input 0: is high pulse input. 1: is switch input P05.01 S1 terminal function 0: No function 1: Forward rotation 2: Reverse rotation 3: 3-wire control 1 S2 terminal function 4: Forward jogging 5: Reverse jogging P05.02 6: Coast to stop 7: Fault reset 4 P05.03 S3 terminal function 8: Operation pause 9: External fault input 10: Increasing setting (UP) 7 P05.04 S4 terminal function 11: Decreasing setting(down) 12: Cancel the change setting P05.05 S5 terminal function 13: Shift between A setting and B setting 14: Shift between combination setting P05.06 S6 terminal function and A setting 15: Shift between combination setting and B setting 16: Multi-step speed terminal 1 17: Multi-step speed terminal 2 P05.07 S7 terminal function 18: Multi-step speed terminal 3 19: Multi- step speed terminal 4 20: Multi- step speed pause P05.08 S8 terminal function 21: ACC/DEC time option 1 22: ACC/DEC time option 2 23: Simple PLC stop reset 24: Simple PLC pause 25: PID control pause 26: Traverse Pause (stop at the current ) 27: Traverse reset (return to the center ) 28:Counter reset P05.09 29: Torque control prohibition 30: ACC/DEC prohibition terminal function 31: Counter trigger 32:Length reset 33: Cancel the change setting temporarily 34:DC brake 36: Shift the command to the keypad 37: Shift the command to the terminals 38: Shift the command to the communication 39: Pre-exciting command 40:Clear the power 41:Keep the power 61: PID pole switching P05.32 Lower limit of AI1 0.00V~P05.34 0.00V P05.33 the lower limit of AI1-100.0%~100.0% 0.0% P05.34 Upper limit of AI1 P05.32~10.00V 10.00V P05.35 the upper limit of AI1-100.0%~100.0% 100.0% P05.36 AI1 input filter time 0.000s~10.000s 0.100s P05.37 Lower limit of AI2 0.00V~P05.39 0.00V P05.38 the lower limit of AI2-100.0%~100.0% 0.0% P05.39 Upper limit of AI2 P05.37~10.00V 10.00V P05.40 the upper limit of AI2-100.0%~100.0% 100.0% P05.41 AI2 input filter time 0.000s~10.000s 0.100s P05.42 Lower limit of AI3-10.00V~P05.44-10.00V P05.43 the lower limit of AI3-100.0%~100.0% -100.0% P05.44 Middle of AI3 P05.42~P05.46 0.00V P05.45 Corresponding middle setting of AI3-100.0%~100.0% 0.0% P05.46 Upper limit of AI3 P05.44~10.00V 10.00V P05.47 the upper limit of AI3-100.0%~100.0% 100.0% P05.48 AI3 input filter time 0.000s~10.000s 0.100s 0:Frequency setting input P05.49 high-speed pulse input 1:Counter input 2:Length counting input P05.50 P05.51 P05.52 P05.53 P05.54 Lower limit of 0.000 0.000k~P05.52 k low setting -100.0%~100.0% 0.0% Upper limit of P05.50 ~k k upper limit of -100.0%~100.0% 100.0% input filter time 0.000s~10.000s 0.100s P06 Group Output terminals P06.01 Y1 output 0:Invalid 1:In operation P06.02 HDO output 2:Forward rotation 3:Reverse rotation 4: Jogging 5: Inverter fault P06.03 Relay RO1 output 6:Frequency degree test FDT1 1 P06.04 Relay RO2 output 7:Frequency degree test FDT2 8:Frequency arrival 9:Zero speed running 10:Upper limit arrival 11:Lower limit arrival 12:Ready for operation 13:Pre-magnetizing 14:Overload pre-alarm 15: Underload pre-alarm 16:Completion of simple PLC step 17:Completion of simple PLC cycle 18:Setting count arrival 19:Defined count arrival 20:External fault valid 21:Length arrival 22:Running time arrival 5 23:MODBUS communication virtual terminals output 26: DC bus voltage establishment 27: Auxiliary pump 1 28: Auxiliary pump 2 P06.14 AO1 output 0: Running 1:Setting P06.15 AO2 output 2: Ramp reference 3: Running rotation speed 4: Output current (relative to 2 times rated current of the inverter) 5: Output current (relative to 2 times rated current of the ) 6: Output voltage 7: Output power 9: Output torque P06.16 HDO high-speed pulse output 10: Analog AI1 input 11: Analog AI2 input 12: Analog AI3 input 13: High speed pulse input 14: MODBUS communication set 1 15: MODBUS communication set 2 22: Torque current (relative to 3 times rated current of the ) 23: Ramp reference (with sign) P07 Group Human-Machine Interface P07.27 Current fault type 0:No fault P07.28 Previous fault type 1: IGBT U phase protection (OUt1) 2: IGBT V phase protection (OUt2) 3: IGBT W phase protection (OUt3) 4: OC1 5: OC2 6: OC3 (Over-current) 7: OV1 8: OV2 9: OV3 (Over-voltage) 10: UV (DC bus under-voltage) 11: Motor overload (OL1) 12: Inverter overload (OL2) 4 / 5 EL088A01

P07.29 Previous 2 fault type 13: Input side phase loss (SPI) P07.30 P07.31 Previous 3 fault type Previous 4 fault type 14: Output side phase loss (SPO) 15: Overheat of the rectifier module(oh1) 16: Overheat fault of the inverter module(oh2) 17: External fault (EF) 18: 485 communication fault (CE) 19: Current detection fault (ItE) 20: Motor antotune fault (te) 21: EEPROM operation fault (EEP) 22: PID response offline fault (PIDE) 23: Braking unit fault (bce) P07.32 Previous 5 fault type 24: Running time arrival (END) P07.33 P07.34 P07.35 P07.36 Running at Ramp reference at Output voltage at the Output current at current fault 25: Electrical overload (OL3) 26: Panel communication fault (PCE) 27: Parameter uploading fault (UPE) 28: Parameter downloading fault (DNE) 32: Grounding short circuit fault 1 (ETH1) 33: Grounding short circuit fault 2 (ETH2) 36: Undervoltage fault (LL) 0.00 0.00 0V 0.0A P07.37 Bus voltage at 0.0V P07.38 P07.39 P07.40 Max. temperature at Input terminals state at Output terminals state at P08 Group Enhanced function 0.0 0 0 P08.27 Set running time 0~65535 min 0min P08.28 Fault reset times 0~10 P08.29 Interval time of automatic fault reset 0.1~3600.0s 1.0s P08.37 Energy braking enable 0:Disable 1:Enable P08.38 Threshold voltage P08.39 Cooling fan running mode P08.50 Magnetic flux braking P08.51 Input power factor of the inverter P09.00 PID reference source The setting range: 200.0~2000.0V 400V voltage: 700.0V 500V voltage: 900.0V 660V voltage: 1120.0V 0: Fan only operates in RUN state 1: Fan operates always, if power is on 0: Invalid. 100~150: The bigger the coefficient, the stronger the braking is. 0 0.00~1.00 0.56 P09 Group PID control 0:Keypad digital reference 1:Analog channel AI1 reference 2:Analog channel AI2 reference 3:Analog channel AI3 reference 4:High speed pulse set 5:Multi-step speed set 6:MODBUS communication set P09.01 Keypad PID preset -100.0%~100.0% 0.0% P09.02 PID feedback source P09.03 PID output feature 0:Analog channel AI1 feedback 1:Analog channel AI2 feedback 2:Analog channel AI3 feedback 3:High speed feedback 4:MODBUS communication feedback 0: PID output is positive 1: PID output is negative P09.04 Proportional gain (Kp) 0.00~100.00 1.0 P09.05 Integral time (Ti) 0.01~10.00s 0.10s P09.06 Differential time (Td) 0.00~10.00s 0. 00s P09.07 Sampling cycle (T) 0.000~10.000s 0.100s P09.08 PID control deviation limit 0.0~100.0% 0.0% P09.09 Output upper limit of PID P09.10~100.0% 100.0% P09.10 Output lower limit of PID -100.0%~P09.09 0.0% P11 Group P11.00 Phase loss protection P11.01 P11.02 Sudden power loss -decreasing Protective parameters 0: Input phase loss protection disable 1: Input phase loss protection enable 0: Output phase loss protection disable 1: Output phase loss protection enable LED hundreds: 0: Input phase loss hardware protection disable 1: Input phase loss hardware protection enable 0: Enable 1: Disable Frequency decreasing 10.00 ratio of sudden power loss 0.00/s~P00.03 (the Max. ) /s 111 P11.03 Overvoltage stall protection 0: Disable 1: Enable 1 P11.04 P11.05 Protection voltage at overvoltage stall Current limit action P11.06 Automatic current limit P11.07 P11.08 P11.09 P11.10 P11.11 P11.12 P11.13 P11.16 The decreasing ratio during current limit Overload pre-alarm of the /inverter Overload pre-alarm test level Overload pre-alarm detection time Detection level of the Detection time of the Output terminal action during fault Extension functions 120~150% (standard bus voltage 400V) 140% 120~150% (standard bus voltage 220V) 120% Setting range of P11.05: current limit 0: Invalid 1: Always valid overload alarm 0: Valid 1: Invalid Setting range of P11.06: 50.0~200.0% Setting range of P11.07: 0.00~/s Setting range of P11.08:0x000~0x131 0: Overload pre-alarm of the 1: Overload pre-alarm of the inverter 0: The inverter continues to work after 1: The inverter continues to work after and the inverter stops running after overload fault 2: The inverter continues to work after overload pre-alarm and the inverter stops running after underload fault 3: The inverter stops when overloading or underloading. LED hundreds : 0: Detection all the time 1: Detection in constant running Setting range of P11.09: P11.11~200% Setting range of P11.10: 0.1~3600.0s 01 Constant 160.0% Variable 120.0% 10.00 /s 0x000 Constant 150% Variable 120% 1.0s 0~P11.09 50% 0.1~3600.0s 1.0s 0: Action under fault undervoltage 1: No action under fault undervoltage 0: Action during the automatic reset 1: No action during the automatic reset Voltage drop -decreasing 0: Voltage drop -decreasing disable 1: Voltage drop -decreasing enable Step 2 ACC/DEC time option 0: Step 2 ACC/DEC time option disable 1: Step 2 ACC/DEC time option enable, 0x00 0 5 / 5 EL088A01