POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured

Similar documents
POLYCAB WIRES PVT. LTD. PCC LP NO. 6 / Dtd : 6th January 2018

POLYCAB WIRES PVT. LTD. PCC LP NO. 3 / Dtd : 1st August 2018

HAVELLS INDIA LIMITED Corp. Office : QRG Towers, 2 D, Sector 126, Noida (UP), Ph : E Mail :

AUTHORISED DEALER: CAPITAL CABLES INDIA PVT. LTD A, Bhagirath Palace, Chandni Chowk, Delhi -06

PRICE LIST FEBRUARY 2017 ALUMINUM UN ARMOURED / ARMOURED W.E.F :

PARAMOUNT COMMUNICATIONS LTD.

PRICE LIST DT. JULY-2014 ALUMINUM UN ARMOURED / ARMOURED W.E.F :

HSN CODE : 8544 PRICE LIST JANUARY 2018 ALUMINUM UN ARMOURED / ARMOURED W.E.F :

LT/HT Power & Control Cables

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

LOW VOLTAGE c a b l e s

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

POLYCAB WIRES PVT. LTD.

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

N2XSERY 3 x (25-300) mm² 3.6/6 kv

PVC INSULATED HEAVY DUTY CABLES


CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1

Details make the Difference

I N T R O D U C T I O N

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Power & Control Cable IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC

FR-3S Fire Resistant Cables

flame Retardant overall screened Instrumentation cables (Multicore)

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv

Wires that don t catch fire

XLPE Insulated 1100V. Grade. Aluminium & Copper, Power & Control, Armoured & Unamoured Cables. As per IS : 7098

600/1000V, XLPE Insulated Cables according to IEC

AN ISO 9001 : 2008 COMPANY

LSZH Fire Resistant Cables

Power & Control Cable IEC

Caledonian Medium Voltage Cables

Power & Control Cables

Caledonian Medium Voltage Cables

P High Voltage Catalogue Cables Australia Powering your Project

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

Details make the Difference

List Price w.e.f. 08th May, 2018 s s s s s s s

List of Plant & Machinery for Cables & Wires

xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. ISO 9001:2000 IS : 69 4

600/1000V, PVC Insulated Cables according to IEC

HOUSE - WIRING, INDUSTRIAL WIRING.'

List Price w.e.f. 08th May, 2018 s s s s s s s

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

TECHNICAL CATALOGUE 1

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

LT / HT Cables/ EHV cables: POLYCAB / HAVELLS / FINOLEX / DIAMOND

N2XR(AL)Y 1 x (25-800) mm² 0.6/1 kv

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

Cold-shrinkable Silicone 12 kv - 24 kv - 36 kv

Power & Control Cable IEC

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

HT, LT U.G. cables & PVC insulated Al wire

3. Fire Resistant Cables

o o blue-brown Fire Performance BS EN BS EN

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Firetec BS 7846 LPCB BASEC Approved Power Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

Any inquiries, please feel free to contact or Caledonian

BS6724 SWA/LSZH Cable IEC /1000V

LUGS GLANDS & LUGS GLANDS A2/BW/CW. TAN TECK SENG Electric Co. (Pte) Ltd 2009/2010

Performs under pressure. Our instrumentation cables keep everything in tune.

a Nexans company Catalogue 2008

CONTROL CABLES CABLES FZE.

Major Approvals. Product Range. Technology. Quality. Reliability. Accolades

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

The cables you need when you need them

Nexans Network Solutions Div. Euromold

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

Unarmoured Single-Core Cables to BS6883

Your Partner in Safe Power Solutions. About RESCAB

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data

Transcription:

"POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire for single core up to 70 sqmm balance Aluminium strip, Glavanised wire for cables upto 2x10 sqmm, 3x10 sqmm,4x6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 Aluminium Size in Sq.mm. 1 Core 2 Core 3 Core 3.5 Core 4 Core A2XWaY / A2XFaY A2XWY / A2XFY A2XWY / A2XFY A2XFY A2XWY / A2XFY 2.5 77 85 98 4 83 91 105 6 97 106 120 10 115 134 154 16 75 135 143 171 25 91 139 181 203 220 35 110 171 229 257 286 50 133 213 289 334 369 70 170 285 389 454 500 95 192 366 483 548 610 120 230 435 578 685 747 150 273 526 713 811 920 185 334 655 871 1012 1143 240 410 852 1114 1273 1459 300 499 1038 1346 1561 1758 400 627 1307 1711 1987 2234 500 858 1730 2318 2701 3032 630 1002 2177 3073 3670 4102 800 1381 1000 1593 a) Round Wire Armouring - 2 x 16 & above 25% - 3 x 16 & 3.5CX25 & above 25% - 4 x 10 & above 25% - For Single core 95 & above 25% b) Stranding 10 sq.mm and below 10% c) Extruded PVC Innersheath Up 50 5% Extruded PVC Innersheath 70 & Above 2.5% d) HR PVC Insulation 10% e) HR PVC Inner Sheath 5% f) HR PVC Outer Sheath 5% g) Oxygen Index (FR) 2.5% h) PVC Insulated Cables 8% FRLS Loading Factor LSZH Cable Size (Sq.mm) Inner Sheath Outer Sheath Inner Sheath Outer Sheath Power (Al.) Upto 16 10% 7.5% 20% 25-50 7.5% 7.5% 12.5% 70 & above 5% 5.0% 12.5% Power Single Core (Al.) Upto 16 -N.A- 10% -N.A- 25% 25-50 -N.A- 10% -N.A- 20% 70 & above -N.A- 7.5% -N.A- 17.5% Page 1 of 8

"POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 Aluminium Unarmoured Size in Sq.mm. 1 Core 2 Core 3 Core 3.5 Core 4 Core A2XY A2XY A2XY A2XY A2XY 4 54 58 65 6 61 69 82 10 72 89 108 16 42 89 114 140 25 55 114 156 178 190 35 68 144 199 227 252 50 89 185 261 301 331 70 118 248 361 415 461 95 161 333 446 516 578 120 201 398 551 648 720 150 244 483 683 782 894 185 300 604 849 984 1110 240 376 802 1086 1253 1422 300 461 990 1335 1540 1739 400 605 1269 1677 1943 2194 500 720 1596 2185 2525 2849 630 859 2012 2895 3424 3844 800 1203 1000 1415 a) Stranding 10 sq.mm and below 10% b) Extruded PVC Innersheath Up 50 5% Extruded PVC Innersheath 70 & Above 2.5% c) HR PVC Insulation 10% d) HR PVC Inner Sheath 5% e) HR PVC Outer Sheath 5% f) Oxygen Index (FR) 2.5% g) PVC Insulated Cables 8% FRLS Loading Factor LSZH Cable Size (Sq.mm) Inner Sheath Outer Sheath Inner Sheath Outer Sheath Unarmd. Power (Al.) Upto 16 10% 7.5% 20% 25-50 7.5% 7.5% 12.5% 70 & above 5% 5% 12.5% Power Single Core (Al.) Upto 16 -N.A- 10% -N.A- 25% 25-50 -N.A- 10% -N.A- 20% 70 & above -N.A- 7.5% -N.A- 17.5% Page 2 of 8

"POLYCAB" Brand Power/Control Copper Cables, Solid Copper conductor upto 6sqmm balance Stranded, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Unarmoured/Armour (Glavanised wire for cables up to 10 x 1.5 sqmm, 8 x 2.5 sqmm, 2 x 10 sqmm, 3 x 10 sqmm, 4 x 6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 Copper Cable Size in sq.mm 2XWaY / 2XFaY 2XWY / 2XFY 2XWY / 2XFY 2XFY 2XWY / 2XFY 2XWY / 2XFY 2XWY / 2XFY 4 146 189 239 315 378 441 6 195 260 334 437 511 608 10 310 417 537 794 16 216 442 589 774 1065 Number of Cores 2XWY/2XFY 2XWY/2XFY Number of Cores 1.5 Sq.mm. 2.5 Sq.mm. 1.5 Sq.mm. 2.5 Sq.mm. 2 86 112 14 354 491 3 105 141 16 366 554 4 125 176 19 424 649 5 147 211 24 531 814 6 168 245 27 593 906 7 186 277 30 679 1045 8 211 311 37 828 1275 10 270 364 44 1005 1578 12 311 426 61 1372 2150 EXTRA FOR SPECIAL CONSTRUCTION (CONTROLCABLES ): A) Tinning 3% B) Stranding (Upto 6 SQ.MM ) 4% C) Extruded Innersheath 2.50% D) Round Wire Armouring 1C x 95 sq. mm & above 7.50% 1.5 sq.mm - 12 core & above 2.5 sq.mm - 9 core & above 10 sq.mm - 4 core & above 16 sq.mm - 2 core & above 16 sq.mm - 3 core & above E) OXYGEN INDEX (FR) 2.50% F) HR PVC Insulatoin 7% HR I/S & O/S 5% Each G) FRLS Loading-Power Cable (upto 6 Sq.mm.) 7.50% FRLS Loading-Power Cable (10 Sq.mm. & above) 4% H) PVC Insulated Cables 5% 1 Core 2 Core 3 Core 4 Core 5 Core 6 Core Control Cables FRLS Loading Factor- Control Cable LSZH Cores Inner Sheath Outer Sheath Inner Sheath Outer Sheath 2 to 4 Core 5% 6% 5 to 10 Core 5% 4% 12 & Above 5% 4% 12.50% 12.50% As per the international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor mentioned in the price-list are only for guide-lines and are as per market convention, It may vary within the prescribed limit of IS:8130-1994,with related classes and tables: 7 Core Page 3 of 8

2XY 2XY 2XY 2XY 4 118 166 214 6 167 236 309 10 276 389 511 16 200 394 576 761 Number of Cores 2XY 2XY Number of Cores 1.5 Sq.mm. 2.5 Sq.mm. 1.5 Sq.mm. 2.5 Sq.mm. 2 61 86 14 287 446 3 76 111 16 326 511 4 95 142 19 383 603 5 113 169 24 484 759 6 133 202 27 542 849 7 151 232 30 620 972 8 175 265 37 757 1193 10 211 327 44 898 1433 12 249 387 61 1235 1970 EXTRA FOR SPECIAL CONSTRUCTION (CONTROLCABLES ): A) Tinning 3% B) Stranding (Upto 6 SQ.MM ) 4% C) Extruded Innersheath 2.5% D OXYGEN INDEX (FR) 2.5% E) HR PVC Insulation 7% HR PVC I/S & O/S F) FRLS Loading-Power Cable (upto 6 Sq.mm.) 5% Each 7.50% FRLS Loading-Power Cable (10 Sq.mm. & above) 4% G) PVC Insulated Cables 5% POLYCAB WIRES PVT. LTD. "POLYCAB" Brand Power/Control Copper Cables, Solid/Stranded Copper conductor, XLPE Insulated, cores laid up, PVC tape/pvc Extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 Cable Size in sq.mm Copper Unarmoured 1 Core 2 Core 3 Core 4 Core Control Cables FRLS Loading Factor- Control Cable LSZH Cores Inner Sheath Outer Sheath Inner Sheath Outer Sheath Unarmd 2-4 5% 6% 5-10 5% 4% 12 & Above 5% 4% 12.5% 12.5% As per the international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor mentioned in the price-list are only for guide-lines and are as per market convention, It may vary within the prescribed limit of IS:8130-1994,with related classes and tables: Page 4 of 8

"POLYCAB" Brand Power/Control Copper Cables, Solid Copper conductor upto 6sqmm balance Stranded, XLPE Insulated, cores laid up, PVC tape innersheathed for Multicore Cables, Unarmoured/Armour (Glavanised wire for cables up to 10 x 1.5 sqmm, 8 x 2.5 sqmm, 2 x 10 sqmm, 3 x 10 sqmm, 4 x 6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 Copper Cable Size in sq.mm 1 Core 2 Core 3 Core 3.5 Core 4 Core 2XWaY / 2XFaY 2XWY / 2XFY 2XWY / 2XFY 2XFY 2XWY / 2XFY 2XWY / 2XFY 25 357 674 966 1163 1272 1737 35 484 921 1329 1526 1754 2399 50 654 1251 1812 2118 2400 3283 70 921 1770 2573 2998 3438 95 1295 2542 3695 4317 4946 120 1628 3188 4644 5531 6224 150 2024 3976 5796 6684 7769 185 2491 4892 7132 8338 9554 240 3198 6291 9188 10710 12315 300 3987 7835 11439 13341 15345 400 5224 10272 15011 17357 20133 500 6592 630 8296 800 10512 1000 13121 5 Core POLYCAB Brand Power/Control Copper Cables, Solid/Stranded Copper conductor, XLPE Insulated, cores laid up, PVC tape/pvc Extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 Copper Unarmoured Cable Size in sq.mm 1 Core 2 Core 3 Core 3.5 Core 2XY 2XY 2XY 2XY 2XY 25 309 604 905 1093 1197 35 425 837 1252 1441 1659 50 582 1145 1718 2010 2275 70 828 1628 2453 2860 3282 95 1112 2265 3407 3978 4563 120 1404 2850 4287 5106 5757 150 1754 3556 5361 6181 7196 185 2160 4384 6606 7726 8864 240 2783 5653 8525 9939 11441 300 3467 7052 10630 12398 14271 400 4560 9258 13959 16152 18750 500 5757 630 7252 800 9203 1000 11500 EXTRA FOR SPECIAL CONSTRUCTION (CONTROLCABLES ): A) Tinning B) Stranding (Upto 6 SQ.MM ) C) Extruded Innersheath 3% 4% 2.50% D) Round Wire Armouring 1C x 95 sq. mm & above 10 sq.mm - 4 core & above 16 sq.mm - 2 core & above 16 sq.mm - 3 core & above E) OXYGEN INDEX (FR) F) HR PVC Insulatoin 7.50% 2.50% 7% HR I/S & O/S G) FRLS Loading-Power Cable (10 Sq.mm. & above) 5% Each 4% H) PVC Insulated Cables 5% 4 Core As per the international practice which is also adopted by BIS, the size of the conductor is decided by its resistance only. The construction of the conductor mentioned in the price-list are only for guide-lines and are as per market convention, It may vary within the prescribed limit of IS:8130-1994,with related classes and tables: Page 5 of 8

"POLYCAB" Brand Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments. Size in Sq.mm. 3.3 KV (E) / 3.3 KV (UE) 6.6 KV (E) 6.6 KV (UE) / 11 KV (E) 11 KV (UE) 22 KV (E) 33 KV (E) 33 KV (UE) 35 596 50 673 70 701 749 800 95 849 892 947 1224 1274 1699 120 999 1041 1092 1423 1454 1938 150 1128 1174 1220 1573 1604 2052 2437 185 1329 1355 1420 1759 1798 2266 2699 240 1574 1639 1703 2069 2107 2593 3061 300 1860 1955 1981 2379 2417 2912 3413 400 2261 2445 2490 2797 2847 3371 3925 1) Extruded PVC Inner Sheath 3% 2) Pressure Extruded PVC Innersheath 13% 3) Round Wire Armouring - Up to 11 KV (E) 25% 11 KV (UE) & Above 27.5% 4) FRLS PVC Inner Sheath 5% 5) FRLS PVC Outer Sheath 5% 6) FR Sheath with Oxygen Index 3% 3 Core HT Cables Page 6 of 8

"POLYCAB" Brand Stranded Compact Circular Aluminium Conductor, Conductor Screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with Copper tape, AL flat strip / round armoured and overall PVC sheathed cable confirming to IS 7098 / (PART-II) 1985 with latest amendments. 1 Core HT Cables Size in Sq.mm. 3.3 KV (E) / 3.3 KV (UE) 6.6 KV (E) 6.6 KV (UE) / 11 KV (E) 25 35 253 266 50 278 293 70 292 307 299 315 319 334 95 331 347 334 353 355 373 120 373 392 376 397 400 422 150 415 438 421 444 439 464 185 478 504 491 516 527 556 240 591 622 603 634 663 697 300 685 721 703 741 774 816 400 820 863 854 898 927 974 500 1033 1088 1083 1141 1122 1180 630 1281 1348 1303 1372 1337 1408 800 1588 1671 1602 1685 1624 1709 1000 1915 2015 1922 2023 2112 2225 1) FRLS PVC Inner Sheath 7.5% 2) FRLS PVC Outer Sheath 5% 3) Oxygen Index 3% Page 7 of 8

"POLYCAB" Brand Stranded Compact Circular Aluminium Conductor, Conductor Screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with Copper tape, AL flat strip / round armoured and overall PVC sheathed cable confirming to IS 7098 / (PART-II) 1985 with latest amendments. Size in Sq.mm. 25 35 50 70 95 461 487 479 505 640 673 120 534 561 540 568 704 742 150 578 608 588 618 735 774 872 917 185 671 706 689 723 818 860 955 1005 240 772 812 791 832 925 973 1133 1193 300 870 915 889 937 1083 1141 1249 1315 400 1030 1083 1054 1107 1238 1303 1429 1504 500 1287 1353 1287 1353 1520 1601 1649 1737 630 1528 1606 1528 1606 1781 1875 1931 2032 800 1782 1876 1782 1876 2040 2147 2321 2441 1000 2321 2441 2321 2441 2488 2611 2665 2806 1 Core HT Cables 11 KV (UE) 22 KV (E) 33 KV (E) 33 KV (UE) 1) FRLS PVC Inner Sheath 5% 2) FRLS PVC Outer Sheath 5% 3) Oxygen Index 3% Page 8 of 8