Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Similar documents
Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)

Valve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv)

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

BM-01. Electrically operated valves 3/2-way G 1/8, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

BM-02. Electrically operated valves 3/2-way G 1/4, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Series MI-01, MI-02, MI-03

Electrically operated spool valve. The manual override is detent and is operated by screw driver.

NAMUR Technical details

NAMUR Technical details

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

Electrically operated poppet valve. The manual override is detent and is operated by screw driver.

COILS, CONNECTORS, SOLENOID VALVES

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

SOLENOID VALVES AND PNEUMATIC VALVES

3/2-way Solenoid Valve for pneumatics

Solenoid valves MFHE/Pneumatic valves VLHE

Valves and Solenoid valves Series 7

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Directional Control Valve Series 4D01 (DENISON)

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

Valves and Solenoid valves Series E 2/

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

10 mm solenoid valves on manifold with multiconnection D-SUB

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

121 1/8 NPT Solenoid and pneumatic valves size 0,86 in

SOLENOID VALVES AND PNEUMATIC VALVES

Nugget 40, V08 series

Series PD directly operated solenoid valves

24010, 3/2 Direct solenoid actuated poppet valve

Directional Control Valve Series D3W Soft Shift

Series PD directly operated solenoid valves

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

Pilot Operated Pressure Relief Valve Series R5V (Denison)

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Seated valves 500 bar

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Series 581 ISO Pneumatic Directional Control Valves

Control Valve Specifications

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

High pressure valves. 80 to 350 bar

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

VAL-138. Valves. Electrical Details for Solenoid Pilot. Operating Pressure

SOLENOID VALVES AND PNEUMATIC VALVES

Operating Manual for the RE-19 Multi-pin Valve Terminal

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Control & Power, Inc

TECHNICAL CHARACTERISTICS

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

On-off Valves MS-EE, Inch Series Overview

AirLINE and AirLINE Quick electrical/pneumatic Automation System

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Transmitters: Relay Valve VR4151/4152

Pneumatic Valve 4V100 Series

VALVES SERIES 70 DISTRIBUTORS

Line-Mounted Valves L Series. L1 / L2 Series Overview L22 BA4 52. Valve Function. Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* =

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

B1 VALVES SERIES 70 DISTRIBUTORS B1.12

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

NG06. General Size NG6 NG10 Design

Compact design suitable for use in reduced mounting space. CONTROL > Directly operated solenoid valves Series PN GENERAL DATA

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

VALVES ISO 5599/1, SERIES IPV-ISV

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Pilot-Operated Directional Control Valves Series D3 - D11

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Our policy is one of continued research and development. We therefore reserve the right

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

The manifolds can be powered through various fieldbus systems, multipole or common terminals.

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Complete Range of Movement Solutions

STC Solenoid Valve List Price

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

40-501, , ,

HERION SERIES Indirect solenoid actuated soft seal

2/2 Pressure operated valves

Seated valve bidirectional Type WVM-4B-Bi

Solenoid valves VZWM-L, NPT

3/2-way Rocker Solenoid Valve for pneumatic systems

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus

Chapter 11: Valves and Actuators with the NAMUR-interface

Series P directly operated solenoid valves

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

Transcription:

Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 = 24 V DC without plug socket Coil options (plug pins bottom, at ports 1, 3, 5) 411 = 12 V DC without plug socket 412 = 24 V DC without plug socket Design, function and technical data Spool valve is actuated by an electrical signal. Mounting screws and gaskets included in scope of delivery. MF-04-510-HN MF-04-520-HN, MF-04-530-HN, MF-04-533-HN 1 = pressure inlet 2, 4 = outlets (7) = manual override (detent) can be repositioned by 4 x 90h (8) = plug socket can be repositioned by 180h (9) = solenoid coil can be repositioned by 4 x 90h Note: Plug socket(s) not included in scope of delivery. Order number MF-04-510-HN- MF-04-520-HN- MF-04-530-HN- MF-04-533-HN- Please complete according to order code. Function 5/2-way 5/2-way 5/3-way 5/3-way single solenoid double solenoid center position center position exhausted open Connection G1/8 at 2 and 4, flange at 1, 3, 5 Nominal size 4 mm Flow rate 360 Nl/min (0.366 Cv) Pressure range 2.5... 8 bar (36 116 psi) 3... 8 bar (43 116 psi) Response on 13 ms on 15 ms 11 ms time at 6 bar off 16 ms off 22 ms Temperature range 10 hc... + 70 hc (+ 14 F + 158 F) Materials Body: Al (anodized), plastic, Seals: NBR and POM, Inner parts: Al, stainless steel, brass Medium Compressed air in accordance with ISO 8573-1: 2010, Class 7:2:4 and free of aggressive additives. Standard voltage 24 V DC Power consumption 2 W IP 65 according to EN 60529 Weight 0.112 kg (0.246 lb.) 0.181 kg (0.398 lb.) 0.180 kg (0.396 lb.) 0.178 kg (0.392 lb.) 4.210 Subject to change

Accessories for series MF-04 Solenoid coil, plug sockets Solenoid coil 23-M-20- Standard coil page 4.282 Plug sockets 28-ST-02-01 Standard plug socket page 4.284 28-ST-09- Plug socket with LED page 4.284 28-ST-10- Plug socket with LED and circuit protection page 4.284 28-ST-10-K3- Plug socket with LED, circuit protection and cable page 4.284 28-ST-02-2-07 Plug socket with M12 plug connection, LED and circuit protection page 4.284 28-ST-02-2-05 Plug socket with M8 plug connection, LED and circuit protection page 4.284 Modular manifolds 4 Manifolds will be delivered completely assembled upon request. Manifold. Available from 2 to 12 stations RF-24/n-P page 4.212 Base element, available with 1, 3, 5, 7, 9 and 11 stations. RF-24/n-G End plate with one valve station RF-24-E Add-on element 1 RF-24-W1 Add-on element 2 RF-24-W2 Clamp for DIN-rail mounting RF-04-K Other elements: RF-04-V Blind plate for blank valve station RE-04-DT Seal plate for two different pressures User Information The manifold RF-24 is an expandable system for valve series MF-04. The assembled manifold includes the base element (RF-24/n-G) and the end plate (RF-24-E). The base element is available with 1, 3, 5, 7, 9 and 11 valve stations. The end plate includes 1 valve station. For odd-numbered stations one element RF-24-W1 is mounted between the base element and end plate. For future expansion add-on elements are required. For even numbered stations begin with the element RF-24-W1. For odd numbered stations begin with the element RF-24-W2. All necessary seals and mounting screws are included with each element. Manifolds can be mounted using the through holes or on a DIN rail using RF-04-K clamp. Subject to change 4.211

Manifolds RF-24 for series MF-04 Manifolds with 2 to 6 stations Side view for any number of stations. Manifolds with 2 to 6 stations. 1 = pressure inlet 2, 4 = outlets Manifolds with 8 to 12 stations. 1 = outlets If the manifold is extended, the dimensions A and B will increase by 20.2 mm for each station. Material: Al (anodized) Order number A B Weight Included elements RF-24/2-P 50 59 0.202 kg (0.445 lb.) 1 x RF-24/1-G, 1 x RF-24-E RF-24/4-P 90.4 99.4 0.324 kg (0.714 lb.) 1 x RF-24/3-G, 1 x RF-24-E RF-24/6-P 130.8 139.8 0.447 kg (0.985 lb.) 1 x RF-24/5-G, 1 x RF-24-E RF-24/8-P 171.2 180.2 0.567 kg (1.250 lbs.) 1 x RF-24/7-G, 1 x RF-24-E RF-24/10-P 211.6 220.6 0.708 kg (1.561 lbs.) 1 x RF-24/9-G, 1 x RF-24-E RF-24/12-P 252 261 0.831 kg (1.832 lbs.) 1 x RF-24/11-G, 1 x RF-24-E 4.212 Subject to change

Accessories for electrically operated valves Solenoid coils and plug sockets Solenoid coils with connection pattern pursuant to DIN EN 175301-803 Shape C Order number 23-M-20-411 23-M-20-412 Standard voltage 12 V DC 24 V DC Power consumption 2 W 2 W IP 65 according to EN 60529 with connected plug socket Duty cycle 100 % Temperature range 20 hc... + 50 hc Voltage tolerance ± 10 % Standard for series MS-20, MF-04 4.282 Subject to change

Accessories for electrically operated valves Plug sockets for coil Plug sockets pursuant to DIN EN 175301-803 Shape C (2pol. + PE, 15,5 x 15,5 mm, Contact distance 9,4 mm) Order number 28-ST-02-01 28-ST-09-112 28-ST-09-127 28-ST-10-112 28-ST-10-127 28-ST-10-K3-112 28-ST-10-K3-127 Standard voltage all 24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC Protective circuit no no no yes yes yes yes Status indicator without yes yes yes yes yes yes IP 65 pursuant to EN 60529 requires a flat gasket Connecting cable without 3 m 3m max. Ø Connecting cable 6,5 mm Max. wire cross section 0,75 mm 2 for coil 23-M-20 Plug sockets with integrated adaptor for M8/M12 (2pol. + PE, 15,2 x 15,8 mm, Contact distance 8 bzw. 9,4 mm) Plug socket 28-ST-02-2-07 2 = not connected 3 = 0 Volt ( ) 4 = +24 Volt (+) 5 = Plug socket 28-ST-02-1-05 and 28-ST-02-2-05 2 = +24 Volt (+) 3 = 0 Volt ( ) 4 = not connected Order number 28-ST-02-1-05 28-ST-02-2-05 28-ST-02-2-07 Standard voltage 24 V DC Protective circuit yes Status indicator yes IP 65 pursuant to EN 60529 requires a flat gasket Contact distance 8 mm 9,4 mm 9,4 mm for plug sockets M8 M8 M12 for coil 23-M-09-19 23-M-20 4.284 Subject to change