User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Similar documents
User Guide. Model Insulation Tester / Megohmmeter. Introduction

User's Manual. Earth Ground Resistance Tester. Model Introduction

Phase Sequence Tester

Model Battery Powered Milliohm Meter

Panel Mount Digital Tachometer Model

User Guide. Model Insulation Tester / Megohmmeter

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

User Guide. Model Insulation Tester / Megohmmeter

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

Model Insulation Tester / Megohmmeter. User Manual

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

User's Guide. True RMS Multim eter. Extech 430

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

User's Manual Digital High Voltage Insulation Tester Model

Digital/Analog Megohmmeter Model 1026 USER MANUAL

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

Digital/Analog Megohmmeter Model 1026

USER MANUAL. Insulation Tester + DMM. Model MG320

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

OPERATING INSTRUCTION

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Non-Contact Phase Rotation Tester

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

User's Guide. CO 2 Meter. Model CO250

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

OPERATING INSTRUCTIONS

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Dawson DDM190D. Digital Multimeter User s Manual

Non-Contact Phase Rotation Tester

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Cable Length Meter INSTRUCTION MANUAL

KMP Insulation-Continuity Tester. Users Manual

INSTRUCTION MANUAL DM5B Fax: (503)

Users Manual. MegOhmMeter

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

362 Clamp Meter. Users Manual

True RMS Autoranging Multimeter

Autoranging Multimeter

Dawson DAN100. Analog Multimeter User s Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

i400s Calibration Information Introduction

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Autoranging Industrial Multimeter

OPERATING INSTRUCTION

365 Detachable Jaw True-rms Clamp Meter

HIGH VOLTAGE PROVING UNIT

A.W. SPERRY INSTRUMENTS INC.

OPERATING INSTRUCTION

Mini Multimeter with Non-Contact Voltage Detector (NCV)

3 PHASE TESTER & MOTOR ROTATION TESTER

373 Clamp Meter. Users Manual

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

i3000s/i2000 Flex AC Current Probe

Table of Contents Title Page No.

362 Clamp Meter. Users Manual

INSTRUCTION MANUAL M110A Fax: (503)

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Tracer ORP PockeTester TM Code 1742

OPERATING INSTRUCTIONS

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

KEWTECH. KT56 digital multi function tester. Instruction manual

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Instruction Manual. Model 310 Digital Milli-Ohm Meter

1.Safe testing IMPORTANT:

Users Manual. Phase Rotation Indicator

OPERATING INSTRUCTIONS

Safety design conforming to the following provisions

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

For technical questions and replacement parts, please call

Go to to register your product and find more information.

Calibration Manual. Detachable Jaw True-rms Clamp Meter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

5.2 PRE-OPERATION PROCEDURE WARRANTY

DIGITAL INSULATION TESTER RS-5500/5505 INSTRUCTION MANUAL

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

BATTERY OPERATED DIGITAL MILLI-OHMMETER

INSP-3 Wiring Inspection Tester

Component Test Fixture

302+/303 Clamp Meter. Users Manual

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

DIGITAL RCD(ELCB) TESTER

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Megohmmeter Test Probe

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

323/324/325 Clamp Meter

OPERATING INSTRUCTIONS

MEGOHMMETER. User Manual

Transcription:

User's Manual High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353

Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on Contact Extech and go to Service Department to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Introduction Congratulations on your purchase of Extech s High Voltage Megohmmeter. This meter is geared toward high voltage insulation testing applications such as appliance testing. In addition to Megohmmeter (Insulation Resistance) measurements, low resistance and AC Voltage can be measured. This professional meter, with proper care, will provide years of safe reliable service. Safety 1. Circuits under test must be de-energized and isolated before connections are made (except for voltage measurements). 2. Circuit connections must not be touched during a test. Use extreme caution when working near bare conductors and bus bars. Accidental contact with conductor could result in electrical shock. 3. Use caution when working near voltages above 60VDC or 30VACrms. 4. After insulation tests, capacitors must be discharged. 5. Test leads (including alligator clips) must be in good working order, clean and without broken or cracked insulation. 6. When servicing, use only specified replacement parts. International Safety Symbols Caution, refer to this manual before using this meter Dangerous Voltages Meter is protected throughout by double or reinforced insulation Rated Environmental Conditions Indoor use only Installation Category III Pollution degree 2 Altitude up to 2000 meters Ambient conditions: Temperature: 32 to 104 o F (0 to 40 o C); RH: 80% max. 2

Specifications General specifications Display Live circuit indicator Withstand voltage Power source Power consumption Fuse protection Operating conditions Dimensions Weight Standards Taut band multi-scale analog display with status indicators and zero adjust LED lights when live circuit is sensed Meets IEC-1010 safety requirements for Cat. III 600V Eight (8) 1.5 AA cells Megohmmeter: 190mA; Continuity: 120 ma (approx.) 250V (1A) for Insulation Resistance and Continuity Tests 32 to 104 o F (0 to 40 o C); < 80% RH 6.7 x 6.5 x 3.6 (170 x 165 x 92mm) 2.1 lbs (970g) CC Low Resistance Range Accuracy Overload Protect. 0 to 50Ω ±5% of reading 250V Open Circuit V: approx 600mV, Short circuit A: approx. 240mA AC Voltage Range Accuracy Line Frequency 600VAC ± 5% of full scale 40Hz to 1kHz Insulation Resistance / Megohmmeter Voltage (±10%) Range Accuracy 250VDC 0 to 50MΩ 500VDC 0 to 100MΩ ± 5% of reading 1000VDC 0 to 400MΩ Short circuit current: 2mA, Overload Protection: 250V 3

Meter Description 1. Analog Display 2. Live Circuit status LED 3. Pointer zero adjustment screw 4. Power Test status LED 5. TEST pushbutton with Lock function 6. Function select switch 7. Battery/Fuse compartment on rear 8. Test lead EARTH input jack 9. Test lead LINE input jack 10. Test lead storage compartment 1 2 3 4 5 6 7 8 9 10 Analog Scale Description 1. Black: Megohmmeter Scale: Multiply reading by 0.5 (for 250V range), 1 (500V), 2 (1000V) 2. Red: AC Voltage Measurement Scale (0 to 600V 3. Green: Low Resistance Scale (0 to 50Ω) 1 2 3 4

Operation CAUTIONS Observe all safety precautions when the FUNCTION switch is set to either the 100MΩ (500V) or the 400MΩ (1000V) position. Connect the meter test leads to the circuit under test before operating the TEST switch. Do not touch the clip ends of the test leads when the TEST switch is pressed. Some electrical equipment, especially cables, may retain an electrical charge when disconnected from the line. It is good practice to discharge such equipment with grounding straps, or other suitable devices, before touching or making connections. The meter automatically discharges the test circuits when the spring loaded TEST switch is released. IMPORTANT NOTE Remove all power to the circuit under test when making resistance measurements. If any voltage is present in the test circuit the red on the meter scale plate will light. Immediately disconnect test leads and turn off power to test circuit. Function switch The FUNCTION switch is a five position rotary switch and is used to select the desired range or function. Test switch The TEST switch is normally OFF. It is a spring loaded, momentary action for safety. The test voltage generated by the meter is automatically discharged when the TEST switch is released. Connecting Test Leads For all functions connect the red test lead to the LINE terminal and the black lead to the EARTH terminal. Test Lead Check Set the rotary switch to the low resistance position (Ω). Connect the leads to the meter and short the clip ends of the test leads and read the green resistance scale on the display. Depress the TEST switch and the resistance should read between 0 and 0.5 Ω. The display should read maximum range with the leads open (not shorted). If any readings are obtained other than the readings just described, the test leads should be considered faulty and must be replaced before using the meter. Failure to do so could result in damage to equipment and electrical shock. Live Circuit Status LED If the Live Circuit status LED is lit, voltage is present on the device under test. DO NOT proceed to test with voltage present. Shock to the user and damage to the meter or device under test can result if testing is done with voltage present. Proceed with testing only when the voltage is removed from the device under test. Power Test Status LED When the meter is actively testing, the Power Test status LED will blink. When this status LED is flashing DO NOT touch the test leads or any exposed parts in the testing area. Hazardous voltages exist that can cause shock. If the Power Test LED fails to light, the batteries must be replaced. Refer to the Maintenance section near the end of this manual. Mechanical zero adjust The pointer should indicate zero on the green 50Ω scale when the FUNCTION switch is in the Ω position, when the test leads are shorted together, and when the TEST switch is depressed. If the pointer does not indicate zero, adjust the white plastic mechanical zero screw located on the lens cover. 5

Megohm Measurements 1. Disconnect all power from the circuit to be tested. 2. Set the FUNCTION switch to the desired test range 3. Connect the alligator clips to the circuit to be tested CAUTION: If the LIVE CIRCUIT indicator lights up at this point, DO NOT operate the test button. Remove the alligator clips and disconnect all power from the circuit. 4. Press and hold the PRESS TO TEST button to make the measurement. Turn the button ¼ turn to the right to lock the test on. 5. Read the value on the MΩ scale and apply the range multiplier to determine the Megohm resistance reading. 6. Release the PRESS TO TEST button and allow the device to discharge before removing the alligator clips. Range Reading Multiplier 250V 0.5 500V 1 1000V 2 Low Resistance (Continuity) Measurements WARNING: Do not run this test unless the voltage on the device under test is zero. If the Live Circuit status LED lights when a test is initiated, immediately abort the test and check that the circuit under test is not powered. 1. Set the Function select switch to the Resistance (Ω) position. 2. Connect the red test lead to the LINE input and the black lead to the EARTH input. 3. Perform a zero adjustment using the zero adjust screw on the display as described above. 4. Connect the test lead tips to the circuit under test and read the resistance on the green display scale. The maximum resistance is 50Ω. The main application for low resistance tests is the identification of low Ω circuits such as motor runs and start windings which may differ by only a few ohms. With a mid-scale reading of 2Ω, this test mode can also be used to check relay contact resistance. AC Voltage Measurements 1. Set the Function select switch to the red ACV 600V position. 2. Connect the red test lead to the LINE input and the black test lead to EARTH. 3. Connect the test lead tips to the circuit under test. 4. Read the voltage value on the red display scale. 6

Maintenance Battery Replacement If the red Power Test status LED no longer lights when a test is initiated, the eight 1.5 V AA batteries must be replaced. 1. Ensure that the meter is not in the test mode and that the test leads aren't connected. 2. Remove the Phillips head screw on the rear battery compartment cover. 3. Remove the battery compartment cover. 4. Replace the eight AA batteries ensuring proper polarity. 5. Affix the rear cover and secure the rear screw. Fuse Replacements To test for an open fuse first assure that the batteries are not defective and then proceed as follows: 1. Connect the test leads to the meter and short the clip ends of the test leads. 2. Set the function switch to the ohms position and press the TEST button. 3. If the fuse is open (blown), the pointer will indicate an open circuit (max resistance). 4. To locate the fuse, open the rear battery/fuse compartment via the Phillips head screw located at the center of the meter case. 5. Replace the fuse (250V, 1A fast blow) located in the battery/fuse compartment just above and to the right of the batteries. Secure the battery/fuse cover. Cleaning Periodically wipe the case with a dry cloth. Do not use solvents or abrasives. Do not allow water to seep into the meter case. Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification on most products or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to ensure calibration integrity. Support Hotline (781) 890-7440 Tech support: Ext. 200; Email: support@extech.com Repair/Returns: Ext. 210; Email: repair@extech.com Website: www.extech.com Copyright 2005 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 7