ST Charger. Industrial Battery Charger

Similar documents
MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

LS/ CCS. Constant Current Charger

Installation and Operation Manual PN Eff

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

High Frequency Battery Charger. Installation and Operation Manual

User s Manual. Automatic Switch-Mode Battery Charger

Installation and Operation Manual Controlled Ferro-Resonant. Model Numbers: CFD CPS CRS CRT

OWNER S MANUAL

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

Section 650 Page 45 M9208G rev.d INDUSTRIAL BATTERY CHARGER OWNER'S MANUAL INDUSTRIAL BATTERY CHARGER

BATTERY CHARGER SERVICE SCHOOL

Industrial Battery Charger. Installation and Operation Manual. PN Eff

High Frequency Battery Charger Installation and Operation Manual

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Industrial Battery Charger

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Battery. Charger Model: Save Important Safety Instructions

A39 UNIVERSAL SCR CHARGER

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

QPET, QPETXU Battery Chargers

QSSE, QSSEX INDUSTRIAL Battery Chargers

FlexCharger Battery Chargers

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

OWNER S MANUAL

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Operating Instructions for PAC800 Battery Charger

CALTRAP INSTALLATION AND OPERATIONS MANUAL

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

BATTERY CHARGER AR-D

10 AMP ON BOARD BATTERY CHARGER

Owner s Manual. Contents GP-PWM-10-SQ

36 VOLT AUTOMATIC BATTERY CHARGER PART NO

AUTO CHARGE D PUMP PLUS

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

MODEL ELC-12/40-CVM-D BATTERY CHARGER

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES

MODEL ELC-12/60-D BATTERY CHARGER

SECTION 1E ENGINE ELECTRICAL

XENON POWER SUPPLY 4000 Watt Gladiator IV

Battery Booster Pack. Instruction Manual for P/N

Owner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ

Page 1 of 1 ALTERNATORS. Overview. Intek TM V-Twin Cylinder OHV Engine Service Manual Version 1.0. Copyright 1999 by Briggs and Stratton Corporation

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

OWNER S MANUAL

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

MODEL 6017 OPERATOR'S MANUAL

OWNER S MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

O P E R A T I N G I N S T R U C T I O N S

DCT SERIES CASE SIZE 3A FILTERED BATTERY CHARGER 12V/200A 24V/ A 48V/100A 120V/50A 240V/25A OPERATION & MAINTENANCE GUIDE

OWNER S MANUAL

OBAE, OBAEXU, ON BOARD Battery Chargers

SCC-MPPT Solar Charge Controller

LESTRONIC II BATTERY CHARGER MODEL 07210

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

SP6. Automatic Battery Charger. Model

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SECTION DC POWER SUPPLY/BATTERY CHARGER

12V Manual Battery Charger & Engine Starter

Solar Charge Controller

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

SCC-MPPT Solar Charge Controller

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

A48 / A48B (base plate) BATTERY CHARGER

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

SCC-MPPT Solar Charge Controller

Models: SP3, SPSS3 Automatic Battery Charger

PROCESS ELECTRONICS CORPORATION

OWNER S MANUAL ECLIPSE II PLUS Opportunity Battery Charger

N1387 Series Troubleshooting Guide for N Alternators

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

24-00 ELECTRICAL POWER

10AMP FULLY AUTOMATIC 6V & 12V BATTERY CHARGER OWNER'S MANUAL

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

OBE, OBEXU, ON BOARD Battery Chargers

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

MODEL 422 Submersible Pump Controller

12V Manual Battery Charger

innovations in battery charging

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

A2P Single Phase Automatic Industrial Battery Charger

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

Transcription:

ST Charger Industrial Battery Charger Installation and Operation Manual ST_13

Table of Contents Pg# 1.0 INSTALLATION 1 1.1 Receiving 1 1.2 Location 1 1.3 Line Voltage 1 1.4 A.C. Service Requirements 2 1.5 Battery Connector and Charger Cable 2 2.0 OPERATION 3 2.1 046-0266 Control (Standard) 3-5 3.0 TROUBLESHOOTING 6-7 3.1 Schematic 8

1. Installation 1.1. Receiving Immediately upon receipt of the charger, check it against the shipping invoice to ensure the shipment is complete and undamaged. Examine the outside of the packing for signs of rough handling before accepting the charger from the carrier. If there is evidence of damage, the receipt should be signed, and both copies (carrier's and receiving copies) marked "Shipment Received Damaged". The carrier's representative should be called immediately and asked to make a "Carrier's Damage Report". If concealed damage is later detected, the carrier should be called and requested to make a "Carrier's Inspection for Concealed Damage Report". After inspection by the carrier, arrangements should be made with the charger representative to have the charger repaired before placing it in service. When contacting your charger representative for assistance on a damage claim or shipment error, provide the Model, and Serial Number of the charger, and a full description of the damage or error. It is good practice to move the charger to the installation site before uncrating. When using bars, hammers, etc. for uncrating, use care to avoid damage to the charger. 1.2. Location For the best operating conditions and longest life, take care in selecting an installation site. Avoid locations exposed to high humidity, temperature extremes or dust. Moisture condensing on machine parts and electrical components can cause corrosion, which seriously affects operation, efficiency and life. Dust and dirt will also decrease heat radiation from heat-generating components, such as transformers and diodes. This will result in higher operating temperatures and shorter life. Adequate air circulation is needed at all times in order to ensure proper operation. Provide a minimum of 6 inches of free air space at the sides and rear of the charger. The front of the charger must remain unobstructed for serviceability. 1.3. Line Voltage ST chargers are set voltage chargers with appropriately sized AC cordage and plugs. Proper grounding of the charger is provided via the cordage and plug connector. The AC service should be verified as correct (voltage, amperage and grounding) for the charger prior to connecting the charger. Warning! Changing the charger s AC connection cord and/or connector may create a hazardous condition. Refer to national and local electrical codes prior to making any changes. - 1 -

1.4. AC Service Requirements Follow local code requirements if they are different than the instructions in this manual. Refer to Table 1-1, to determine the correct ratings for the AC cable, AC fuses, and AC service disconnect switch for the line amperes as listed on the nameplate of the charger for the available AC voltage. TABLE 1-1 Line Amperes Fuse Size Amps Power Cable Size 0.1-4.0 05 #14 4.1-8.0 10 #14 8.1-12.0 15 #14 12.1-16.0 20 #12 16.1-20.0 25 #10 20.1-24.0 30 #10 24.1-28.0 35 #10 28.1-32.0 40 #8 32.1-40.0 50 #8 40.1-48.0 60 #6 48.1-64.0 80 #4 1.5. Battery Connector Charging Cable Verify that the connector on both the battery and the charger are attached so that the positive output terminal of the charger is connected to the positive battery terminal. CAUTION! IF THE POLARITY IS REVERSED, THE DC FUSE WILL BLOW. IF IN DOUBT, CHECK THE POLARITY WITH A DC VOLTMETER. - 2 -

2. Operation The charger utilizes a ferro-resonant transformer to provide isolation from the AC service line and to regulate the charging current. The transformer output is connected to a full-wave bridge of silicon diodes, which provides DC charging current to the battery. The starting charge amps and length of time required for a charge vary depending on the charger model. See the data plate on the charger for information. 2.1 046-0266 CONTROL 2.1.1 Feature Summary Charges flooded lead-acid batteries. Automatic start when battery is connected. Automatic stop when charge is finished. Fully charges partially discharged batteries without overcharging. Dead battery jump start for overly-discharged batteries. Equalize charge by user request. Automatic shut-down if battery starts to overheat. Displays charge status and indications with LED s. 2.1.2 Control Description The front panel has 3 LED s (light emitting diodes). A yellow CHARGE LED indicates when the charger is charging. A yellow 80% LED indicates when the battery has reached 80% state of charge. A multi-color STATUS LED indicates charger status. The front panel has a 2 button keypad that is used to manually stop the charge cycle, and to manually select an equalize cycle. A charge can be stopped by pressing the STOP button. An equalize charge can be requested by pressing the = button and turned off by pressing it again. CHARGE 80% STATUS EMERGENCY STOP PRESS THE STOP BUTTON BEFORE DISCONNECTING THE BATTERY. STOP = DAILY CHARGE CONNECT BATTERY - CHARGER AUTOMATICALLY STARTS AND STOPS WHEN BATTERY IS CHARGED. 046-0266 Control - 3 -

2.1.3 Operation The control provides fully automatic battery charging. The standard charging profile for flooded lead-acid batteries has 2 phases. During phase 1 the battery is charged at high current until the battery is 80% charged. Then phase 1 terminates and phase 2 begins. As the battery voltage rises during phase 2, charging current tapers down toward the finish current and the battery voltage starts to flatten out. Phase 2 ends and the charge is terminated when the battery voltage no longer changes. This termination method is called dvdt-didt. The control offers several safeguards to protect the battery. If a wrong voltage battery is connected, the charger does not start. A Wrong-Battery-Voltage condition is indicated. While charging, if the battery voltage exceeds a profile-specific cut-off value, the charge terminates. If the battery starts to overheat, the charge terminates. 2.1.4 Normal Daily Charge When no battery is connected, the STATUS multi-color LED is flashing green. Connecting a battery to the charger will cause the charger to perform a self-diagnostic test to verify the control is working properly. During this time a lamp test is performed causing all LED s to light. This allows the operator to observe any defective LED s. When the self-diagnostic is complete, the charge starts and the yellow CHARGE LED lights. When the battery is 80% charged, the yellow 80% LED lights and the charger starts phase 2 of the charge cycle. When the charge is finished, the STATUS multi-color indicator lights green indicating the battery is ready to be taken. Warning: Risk of explosion. Do not disconnect the battery while the charger is running. Hydrogen gas produced by the battery during charging can be ignited by arcing that occurs when the battery cable is disconnected. If the battery must be disconnected before the end of the charge cycle, the charger should be turned off first. Press the STOP button, and verify the CHARGE LED goes out and the multi-color STATUS LED is flashing amber. The battery can then be safely disconnected. 2.1.5 Equalize Charge Over time batteries can develop inequalities in cell charge. This can lower the effective capacity of the battery and shorten life. An equalizing charge re-balances the charge in the battery cells. Perform an equalize charge if any of the following conditions exist: 1. On flooded batteries the specific gravity of any cell at the end of charge is 20 points less than the average of all the cells. 2. The on-charge voltage of any cell at the end of charge is 20 millivolts less than the average of all the cells. 3. The battery has been stored for 30 days. The control performs an equalize charge when requested manually. First connect the battery and allow the charge to start normally. Then press the = button. The yellow CHARGE LED will flash. The charge time will be extended to allow the cells to equalize their charge. The equalize cycle can be cleared by again pressing the = button. The yellow CHARGE LED will remain solid. - 4 -

2.1.6 Charge Indications The following table shows the various charge indications displayed by the LED s. If an abnormal charge condition occurs, the charge is terminated. State CHARGE 80% STATUS Description No Battery o o Waiting for battery to be connected. Lamp Test A battery has been connected and the charger is performing a self-test prior to starting a charge cycle. Charging Phase 1 (no =) Charging Phase 1 (=) Charging Phase 2 (no =) Charging Phase 2 (=) o o Normal charging. The battery has not reached the 80% point. An equalize will not be performed for this cycle. o o Normal charging. The battery has not reached the 80% point. An equalize will be performed for this cycle. o Normal charging. The battery has reached the 80% point. An equalize will not be performed for this cycle. o Normal charging. The battery has reached the 80% point. An equalize will be performed for this cycle. Equalizing o Charger is equalizing the battery. Charge Complete Charge Terminated o o The charge cycle is complete and the battery may be taken. o o The charge cycle was terminated by pressing the STOP button. F1 o o Possible shorted cell or low charging amps. Battery did not reach 80% (2.40 V/C) in allowed time. F3/F4 o o Low battery voltage, less than 1.60 V/C (F3) or High battery voltage, more than 2.40 V/C (F4) at start up. F5 o o No charging current to the battery. F7 o Long charge, the charger ran longer than allowed time. F8 o Charger stayed on when control requested it to shut off. o = LED Off = LED On = LED Flashing 2.1.7 F3 (Low Battery) Override If the battery voltage is below 1.6 volts per cell the charger will not start automatically. If this is due to an overly discharged battery of the correct voltage, the F3 indication can be manually overridden by pressing the STOP button while the F3 indication (Low Battery) shows on the LED s. - 5 -

3. Troubleshooting Caution-There are lethal voltages exposed when the charger is energized with the enclosure open. Always disconnect the AC service voltage to the charger and disconnect the battery before opening the enclosure. The following chart lists the most probable cause of a malfunction. 3.1. No charging current, the control has no display, contactor does not operate. A. No AC service voltage. B. Incorrect AC voltage. C. Defective control transformer. D. Defective control board. 3.2. No charging current, control has a display. A. Blown DC fuse. B. Defective ammeter. C. Open battery cell. D. Defective diode. E. Defective capacitor. F. Shorted power transformer secondary. 3.3. AC fuse blows/circuit breaker trips. A. Incorrect fuse rating. B. Incorrect AC voltage. C. Shorted transformer winding. 3.4. DC fuse blows. A. Reversed battery connector. B. Incorrect fuse rating. C. Shorted diode in rectifier assembly. 3.5. Excessive water loss in battery. A. Charger amp-hour rating exceeds the battery amp-hour rating. B. Battery has defective cells. - 6 -

3.6. Low specific gravity at the end of the charge cycle. A. Battery was over-discharged. B. Charger amp-hour rating is less than the battery AH rating. C. Defective open diode. D. Battery has defective cells. E. Battery has been over-watered. 3.7. Charger does not turn off when the control terminates the charge cycle. A. Defective control. B. AC contactor has welded contacts. 3.8. General Maintenance The charger requires a minimum of maintenance. Connections and terminals should be kept clean and tight. The charger should be periodically cleaned with an air hose to prevent any excessive dirt build up on components. Care should be taken not to bump or move any adjustments during cleaning. Make sure that both the AC lines and the battery are disconnected before cleaning. The frequency of this type of maintenance depends on the environment in which this unit is installed. If any cabinet sheet metal panels are removed for cleaning, be certain they are properly reinstalled upon completion. - 7 -

L-1 TRANSFORMER POS. r.::::=;::;:::::::{+ cxriput CONTROL S01 S02 TC c DCF NEG. o.c. OUTPUT GR ft ferro magnetics corporation Power Syatema WIRING DIAGRAM : 1PHof<SE,1TRANS --REV18ION -... -STANDARD CONFIGURATION,CORD CONNECTED NOTES: (DsHOWN IN SET VOLTAGE