INSTRUCTION MANUAL GENERAL SAFETY WARNING

Similar documents
INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

INSTRUCTION MANUAL Rev

DulcoFlex Peristaltic Pump DFC 50

DulcoFlex Peristaltic Pump: DFB13B

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS AMP-22 MODEL

DulcoFlex Peristaltic Pump DFDa70

DulcoFlex Peristaltic Pumps: DFB010 DFB013 DFB016 DFB019 DFB022

Operating instructions. RBT Series Peristaltic Pump

METERING/DOSING PUMP CLOSE-COUPLED B4015D, B4050D, B4100D, B4190D, B2400D, AND B4400D MODELS

Installation, Operation & Maintenance Instruction. Models: FMP Series 30, 40, 50. PeriFlo FMP PERISTALTIC PUMP. Bulletin #: IOM-PFL-4502

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

PNEUMATIC PUMP Series

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

PACKING, HANDLING, TRANSPORTING AND STORING MOTORS

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

pump selection guide PONNDORF PX single series PDX single series PD/2 dual series PK series

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

THIS SYMBOL MEANS A WARNING OR CRITICAL INFORMATION. THIS SYMBOL IS USED TO LIST ADDITIONAL INFORMATION AND TIPS.

CIRCLE SEAL CONTROLS

NECO Pumping Systems

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

A Series. 60 Hz. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

SELF PRIMING CHEMICAL SERVICE PUMPS

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

SOLENOID CONTROL VALVE

PRESSURE REDUCING CONTROL VALVES

FLOAT CONTROL VALVES

314 ORDINARY MAINTENANCE MANUAL FOR. PGA series VERTICAL MOUNTING POSITION. Release A02/15

US - UP2/OIL 12V US - UP2/OIL 24V

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

TECHNICAL SERVICE MANUAL

Vector 4000 Series. Peristaltic Pumps. Models: 4003, 4004, 4006, 4007, 4009, 4010, & Installation, Operation and Maintenance Manual

PULSATION DAMPENERS OPERATION & MAINTENANCE MANUAL

MODULATING FLOAT CONTROL VALVE

MICHIGAN FLUID POWER

Installation and Maintenance Manual

SANITARY/HYGIENIC NON-MOTORIZED

Swing-Flex Check Valve

Operators Manual. Recirculating Chiller /06/08

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

Swing-Flex Check Valve

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Instruction for RBP250-3 and RBP300-3

CIRCLE SEAL CONTROLS

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

Val-Matic 4-20 Air/Vacuum Valve

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS

SAI GM Series Piston Hydraulic Motor Crankshaft Design Radial Piston Motors

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Val-Matic 3-Way Tapered Plug Valve

M-3025CB-AV Fuel Pump

Hydronic Corporation

Val-Matic 1/2-3 Well Service Air Valve With Dual Port Throttling Device

END SUCTION CENTRIFUGAL PUMPS

CHO HELICAL-HYPOID GEAR UNITS

Free Float Air Trap G8

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

Product Service Manual For DLH12DHT SERIES PUMPS

- click here for pricing and ordering

AMP Series. pulsa.com/periflo PERISTALTIC PUMPS. Flow: up to 282 GPM (1067 LPM) Pressure: up to 115 PSI (8 BAR)

PRODUCT SERVICE MANUAL FOR. F312XICR-312_, 325_, 400_ and 437_ Pumps. For Solar Turbines

1/2" AIR DRIVEN DIAPHRAGM PUMP

Marlow Series Cast Iron Swimming Pool Pumps

2-port ball valves with flanged connection, PN25

TECHNICAL SERVICE MANUAL

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

300 SERIES 30100, 30102, 30104, AND MODELS

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

OPERATING SERVICE MAINTENANCE MANUAL

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

CUSTOM COMBINATION AIR VALVE

FLOMOTION FP INSTRUCTION MANUAL PERISTALTIC PUMP

ONYX VALVE CO MODEL DEC Installation & Maintenance

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

Installation, Operation & Maintenance Manual. Models: ChemTuff Series PeriFlo ChemTuff PERISTALTIC PUMP. IOM-PFL-4600-Rev.B

NECO Pumping Systems

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

Starting up hydraulic systems

"U" TROUGH SCREW CONVEYOR CNU SERIES. OPERATING MANUAL FOR INSTALLATION, OPERATING AND MAINTENANCE

4 - Way Control 4 - Way Control 4 - Way Control with lock

200 SERIES 20302, 20402, 20501, 20502, 22001, 22002, 23201, AND MODELS

NMRV - MCV - NRV NMRV+NMRV PC+NMRV

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

½"-3" Air/Vacuum Valve Models 100S to 103S

DATA SHEET 6K151CT2, 6K151CT4, 6K201CT2, 6K201CT4, 6K301CT4, 6K401CT4 OPEN IMPELLER CENTRIFUGAL PUMPS. Stainless Steel Models: SPECIFICATIONS FEATURES

CTC Battery, Inc. Lithium Iron Phosphate Battery Specification

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Transcription:

INSTRUCTION MANUAL This manual forms an integral part of the pump and must accompany it until its demolition. The series AMP peristaltic pump is a machine destined to work in industrial areas and as such the instruction manual must form part of the legislative dispositions and the applicable technical standards and does not substitute any installation standard or eventual additional standard. GENERAL SAFETY WARNING Pumps are machines that can present dangers due to their operating under pressure and containing numerous moving parts. - Improper use - Removing the protections and/or disconnecting the protection device - The lack of inspections and maintenance CAN CAUSE SERIOUS DAMAGE OR INJURY The person in charge of safety should therefore guarantee that - The pump is transported, installed, put in service, used, maintained and repaired by qualified personnel who should possess: - Specific training and sufficient experience. - Knowledge of the technical standards and applicable laws. - Knowledge of the general national and local safety standards and also of installation. Any work carried out on the electrical part of the pump should be authorized by the person responsible for safety. Given that the pump is destined to form part of an installation, it is the responsibility of whoever supervises the installation to guarantee absolute safety, adopting the necessary measures of additional protection. 2

INDEX Page Equipment Identification 01 Cover 02 Index 03 Transport, storage and elevation 04 General safety standards 05 General description 07 Installation 08 Roller pressure adjustment 08 Work conditions 09 Performance curves 10 Checks before starting up the machine 11 Maintenance 11 Removal of the hose disassembly 12 Installation of the hose assembly 12 Problems, causes and solutions 13 Diagram of components parts 14 Spare parts code 15 Warranty Statement 17 3

TRANSPORT, STORAGE and ELEVATION TRANSPORT The pump is protected by a wood packaging. The packaging materials are recyclable. B A STORAGE The pump should be in a resting position refer to figure A (The hose should not be compressed) Avoid areas open to inclement weather or excessive humidity. For storage periods of longer than 60 days, protect the coupling surfaces (clamps, reducers, motors) with adequate anti-oxidant products. Spare tubes should be stored in a dry place away from the direct light. LIFTING For the elevation of the pump, it has a eye bolt on the top ( See figure B ). 4

GENERAL SAFETY STANDARDS Instructions in this manual that may compromise safety standards are identified by this symbol Instructions in this manual that may compromise electrical safety are identified by this symbol. WARNING! Instructions in this manual that may compromise the proper operation of the pump are identified with this symbol. Do not start the pump without first having installed the front cover. For any operation of the equipment, it is necessary to make certain that the pump is stopped and the electrical supply disconnected. Changing the hose should be done with the pump stopped. WARNING! WARNING! WARNING! Do not exceed the nominal design pressure, speed or temperature of the pump, or use the pump for applications other than that originally planned without first consulting the manufacturer. Cleaning the pipe, including the hose, should be done with fluids compatible with the pump hose and within its maximum recommended temperature. Do not start the pump without it being properly secured to the floor. Do not attempt carry out any maintenance operations or dismantle the pump without first making sure that the suction and discharge pipes are not under pressure, and are empty or isolated by proper valving. 5

The start system of the motor should be provided with a direction inverter, stop-go button and emergency stop button (together with the pump), in such a way that the pump can be operated or the hose changed with total safety. Peristaltic pumps are positive displacement devices capable of generating high pressures. To prevent possible overload of pressure due to for example: the accidental closure of a valve. It is advisable to fit a safety device such as: a safety valve or other pressure limiting device in the discharge piping. Check the rotation of the pump, as it is reversible, it could generate pressure in the suction and compromise the safety of the installation. The circulation of the fluid should be in the same direction as the turning direction of the pump as seen from the front cover. The durability of the hose may vary due to operating conditions, so the possibility of a rupture and subsequent leakage of fluid should be anticipated. The (optional) hose leakage detection probe can be interlocked to stop the pump and/or actuate an automatic valve and/or sound an alarm. 6

GENERAL DESCRIPTION PERISTALTIC PUMP Construction of the pump. As shown in the figure below, the PeriFlo pump unit is a very simple, robust design with very few moving parts. 1 2 3 4 The outer casing (item 1) terminates with 150#ANSI flanged connections. Inside the casing are found the rotor (item 2), completed with two rollers (item 3). As the rotor rotates, the rollers compress the reinforced hose (item 4) generating a pumping action. A change in the direction of rotation will result in a change in direction of the pumped fluid. 7

INSTALLATION Installation should normally be made in a well ventilated area away from heat sources. If it is necessary to place the pump outside, it should be provided with a cover to protect it from sunlight and inclement weather. The positioning of the pump should allow easy access for all kinds of maintenance operations. In general, and to facilitate the changing of the hose, it is advisable to use easily removed connectors. There should be a minimum space of approximately 38 inches and 44 inches for Models FMP30 and FMP40 respectively. Piping Correct Installation Suction: The pump should be as near as possible to the supply of liquid so that the suction pipe is as short and straight as possible. The suction pipe should be perfectly airtight and made of suitable material so that it does not collapse due to internal vacuum. - The minimum diameter should be similar to that of the tubular element. - With viscous fluids a larger diameter is recommendable. (Consult manufacturer or distributor). - The pump has automatic suction and does not need an inlet. The pump is reversible, so the suction and discharge connections are interchangeable. (The pump is normally piped in a manner that best adapts to the physical installation) It is recommended to use a flexible connection between the fixed piping and the pump in order to reduce the transmission of vibration to the piping, Discharge: To reduce power requirements, use the straightest and shortest piping possible. The diameter should be the same as the nominal diameter of the pump, excepting precise calculations of pipe and system losses. - With viscous fluids a bigger diameter is needed. (Consult the manufacturer or distributor). Connecting the fixed piping to the pump with a length of flexible pipe facilitates maintenance and avoids vibrations and loads on the pump. Fix the piping firmly. The discharge will pulse: To reduce pulsation, it is advisable to install adequate pulsation dampening equipment in the discharge line.. (See accessories.) 8

ROLLER/SHIM - PRESSURE ADJUSTMENT FMP-30 ( Number of shims of 0,5 mm. ) SPEED - RPM 0-19 20-39 40-59 60-79 80-99 PRESSURE- PSIG 7,5 1 1 0 0 0 30 1 1 1 1 1 60 2 1 1 1 1 90 2 2 2 1 -- 115 3 2 2 -- -- FMP-40 ( Number of shims of 1 mm. ) SPEED - RPM 0-19 20-39 40-59 60-79 80-99 PRESSURE- PSIG 7,5 4 4 4 4 3 30 5 4 4 4 4 60 5 5 5 4 4 90 6 5 5 -- -- 115 6 6 -- -- -- WORKING CONDITIONS MATERIAL TEMPERATURE MIN (ºC) TEMPERATURE MÁX (ºC) TEMPERATURE MIN. AMBIENT (ºC) PRESSURE MAX PSI NR -20 90-40 115 NBR -10 80-40 115 EPDM -10 90-40 115 NR-(FD GR) -10 90-40 115 NBR-(FD GR) -10 90-40 115 9

PERFORMANCE CURVES l /h FMP-30 Continuous duty 10 20 30 40 50 60 70 80 90 100 l /h 8 bar 4 bar 2 bar 4400 3960 3520 3080 2640 2200 1760 1320 880 rpm FMP40 440 0 Continuous duty 10 20 30 40 50 60 70 80 rpm 8 bar 4 bar 10

CHECKS BEFORE SWITCHING ON THE PUMP Check that the pumping equipment has not suffered any damage during transportation or storage, any damage should be notified to the supplier immediately. Check that the supply voltage is suitable for the motor. Make sure that the hose is suitable for the fluid to be pumped and will not be chemically affected, and that the temperature of the fluid does not exceed that recommended for the hose. If the hose is in a resting position, then the pump has come from storage or transportation; it is necessary to install the second roller. Caution: Do not switch on the pump without the pump cover being correctly installed. Lubrication: Check that the pump drive, the hose and rollers are correctly greased. The hose and rollers should be lubricated with specially formulated silicon grease that can be obtained from PERIFLO, INC or from the authorised distributor. Check that the protectors of the moving parts are correctly assembled. Check that the thermal overload protector corresponds with that of the values on the plate on the motor. Check that the direction of rotation is the desired one. (rotation test). Check that the optional electrical components are connected to the control panel and test that they function correctly. Check that a proper pressure gauge is installed in the discharge. If the application involves a highly viscous fluid, it is recommended that a proper absolute-pressure gauge be installed in the suction line. Check in predicted working conditions that the values of flow, pressure and absorbed power of the motor correspond to the project. MAINTENANCE Any work carried out on the pump must be done when the pump is stationary and disconnected from the electrical supply. Lubrication Check that the lubricant level in the gear reducer and/or the variator are correct, and carry out periodic changes of lubricant according to the maintenance manual. FOLLOW THE LUBRICATION RECOMMENDATIONS OF THE DRIVE MANUFACTURER. 11

REMOVING OF HOSE - DISASSEMBLY Close suction and discharge valves to properly isolate the pump and prevent loss of the product. Disconnect and remove the suction and discharge piping. Remove the front cover. Remove the roller that is not in contact with the hose. Replace the front cover (temporarily with only 2 bolts) and rotate the pump 180º until the other roller doesn t contact the hose. (this may be done by bumping the drive) Remove the inlet and outlet flange assemblies (items 12 & 14) and the closing rings (item 13) Note that it is not necessary to disassemble the flange assemblies. Remove the hose. INSTALLING THE HOSE - ASSEMBLY Remove the front cover and clean the internal surfaces of the pump body. All contamination should be removed. Inspect the rollers and roller bearings to insure continued smooth operation and inspect rotor seals to insure that there is no foreign matter that could impede proper performance. Lubricate the internal faces of the pump body where there could be contact with the hose, lubricate the exterior surface of the new hose and lubricate the surface of the rollers with PeriFlo Silicon grease. Install the closing ring and flange assembly to one end of the new hose, and install the new hose into the pump. Install the closing ring and flange assembly to the other end of the hose. Install the flange assemblies the pump body. (compressing the closing ring around the hose) Fit the front cover (temporarily with only 2 bolts) and rotate the pump 180º until the installed roller fully contacts the hose. Remove the front cover and install the second roller. Install the front cover. Connect the suction and discharge piping. 12

Elevated Temperature PROBLEMS, CAUSES AND SOLUTIONS PROBLEM POSSIBLE CAUSE SOLUTIÓN Hose with no lubricant Elevated temperature of product Poor or bad suction conditions Reduction of Capacity/pressure Excessive pipe tightening Excessive number of shims Excessive pumping speed Suction or discharge valve closed. Hose insufficiently compressed Use special PeriFlo Silicon lubricant Reduce pumping temperature Check there are no obstructions Recalculate pipe diameteres and lengths Check roller pressure adjustment Confirm the proper number of shims Reduce velocity of pump Open valves Check roller pressure adjustment/shims Vibrations in pump and piping Rupture of the hose (the product leaks to the casing) Partial obstruction of suction piping Insufficient product amount in suction reservoir Insufficient diameter of suction piping Excessive length of suction pipe High viscosity of product Entry of air via the suction connections High pulsation on suction The piping is not correctly fitted together Excessive pumping speed Replace drive hose Clean piping Fill Reservoir or stop pump Increase pipe diameter/reduce pump speed Shorten suction piping Reduce viscosity Increase suction pipe diameter Confirm that the pump is suitable Tighten connections and accessories Mount pulsation dampening equipment Reconsider application (speed etc.) Refit piping Reduce the speed of the pump Short hose life Stretching of the hose inside the pump The pump does not start Insufficient diameter of piping Bedplate of pump loose Elevated pulsation of pump Chemical attack High speed of pump High pumping temperature High working pressure Abnormal elevation of temperature Unsuitable lubricant Insufficient quantity of grease Cavitation of the pump Insufficient grease High suction pressures (>45 psi) Hose full of sediment Brackets insufficiently tightened Insufficient starter power Insufficient power from frequency convertor Blockage in the pump Increase pipe diameter Fix the bedplate firmly Install suction and/or outlet pulsation dampening equipment Confirm compatibility of the hose with the pumped fluid and any cleaning fluids Reduce speed of pump Reduce temperature of product Reduce speed of pump Increase diameter of piping Check roller pressure adjustment/shimming Use PERIFLO lubricant Top up lubricant Reconsider suction conditions Top up lubricant Reduce suction pressure Clean hose Retighten brackets Increase starter power Increase power/boost Check that the voltage is adequate Do not drop below a frequency of 10Hz (confirm this point with the distributor) Start-up will require a minimum of 10 Hz Check there are no obstructions in the pipe 13

21 25 23 19 17 2 15 18 9 22 26 28 3 1 13 27 5 8 6 24 12 7 10 14 4 16 11 20 FMP-30/40 14

FMP-30 POS. Description Q CODE MATERIAL 1 Pump body 1 107.00.01 Cast Iron 2 Bearing housing 1 107.00.03 3 Rotor shaft 1 107.00.04 Steel 4 Rotor 1 107.00.05 5 Roller support 2 107.00.06 6 Shim 107.00.07 Stainless 7 Shaft screw w/nut and washer 2 107.00.08 M10 8 Roller shaft 2 107.00.09 9 Roller 2 107.00.11 10 Metallic cover 1 107.00.13 11 Polycarbonate cover 1 107.00.14 12 Press flange 2 107.00.15 Anodized Steel 13 Closing ring 2 107.00.16 Steel 14 Connection flange 1-1/4 ANSI 2 107.00.38 316SS Connection SS 1-1/4" MNPT 2 107.00.34 316SS Connection PolyPro 1-1/4 MNPT 2 107.00.44 Polypropylene Connection 1-1/2 TRI-CLAMP 2 107.00.36 316SS 15* Natural Rubber Hose 1 107.00.18 Natural Rubber Hose (Food Grade) 1 107.00.19 Buna N Hose 1 107.00.20 Buna N Hose (Food Grade) 1 107.00.21 EPDM Hose 1 107.00.22 16 Shaft cap 1 110.00.23 17 Base left 1 100.01.24 18 Base right 1 100.01.25 19 Base middle 2 100.01.26 20 Stud 2 106.00.27 21 Driver 1 22 Ball bearing - rear 1 100.01.28 23 Ball bearing - front 1 100.01.29 24 Ball bearing roller 4 107.00.30 25 Ring for shaft 1 100.01.31 26 Lip seal - housing 1 100.01.32 27 Lip seal roller 4 107.00.33 28 Eye bolt 1 106.00.40 Check Valve 1 110.00.53 * Food Grade Silicon Grease (16oz.) 106.00.41 * RECOMMENDED SPARE PARTS REV 01.04.00 15

FMP-40 POS. DESCRIPTION Q CODE MATERIAL 1 Pump body 1 106.00.01 Cast Iron 2 Bearing housing 1 106.00.03 3 Rotor shaft 1 106.00.04 Steel 4 Rotor 1 106.00.05 5 Roller support 2 106.00.06 6 Shim 106.00.07 Stainless 7 Shaft screw w/ nut and washer 2 106.00.08 M10 8 Roller shaft 2 106.00.09 9 Roller 2 106.00.11 10 Metallic cover 1 106.00.13 11 Polycarbonate cover 1 106.00.14 12 Press flange 2 106.00.15 Anodized Steel 13 Closing ring 2 104.00.05 Steel 14 Connection flange 1-1/2 ANSI 150 2 106.00.38 316SS Connection SS 1-1/2" MNPT 2 106.00.34 316SS Connection PolyPro 1-1/2 MNPT 2 106.00.47 Polypropylene Connection 1-1/2 TRI-CLAMP 2 106.00.36 316SS 15* Natural Rubber Hose 1 106.00.18 Natural Rubber Hose (Food Grade) 1 106.00.19 Buna N Hose 1 106.00.20 Buna N Hose (Food Grade) 1 106.00.21 EPDM Hose 1 106.00.22 16 Shaft cap 1 110.00.23 17 Base left 1 106.00.24 18 Base right 1 106.00.25 19 Base middle 2 106.00.26 20 Stud 2 106.00.27 21 Driver 1 22 Ball bearing - rear 1 106.00.28 23 Ball bearing - front 1 106.00.29 24 Ball bearing roller 4 106.00.30 25 Ring for shaft 1 106.00.31 26 Lip seal - housing 1 106.00.32 27 Lip seal roller 4 106.00.33 28 Eye bolt 1 Check Valve 1 110.00.53 * Food Grade Silicon Grease (16oz.) 106.00.41 * - RECOMMENDED SPARE PARTS REV 01.04.00 16

WARRANTY - PeriFlo warrants it s RBT and FMP pump equipment against all defects in materials, manufacturing and workmanship for two years from the date of shipment. This warranty does not include normal wearing items such as the hose or the lubricant since their life is highly dependent on the specific operating conditions of the application and installation. - This warranty is valid as long as the equipment functions within the parameters indicated in the technical information card supplied with every pump or on subsequent changes authorized by PERIFLO, Inc. - This warranty includes materials and labor only, and does not include transportation of materials to or from our warehouses in Loveland, Ohio. Transportation charges will be the responsibility of the customer. 17

CbN SERIES 3000 LUBRICATION Series 3000 CbN gearing is shipped with one of the following synthetic lubricants per the table below and fitted with a magnetic drain. Each reducer is filled according to the mounting position specified when ordered. Refer to the unit nameplate and the chart to the left for the mounting position arrangement for your unit. In the case of synthetic oil, the lubricant does not require changing, but it is recommended that proper oil level be checked periodically. SYNTHETIC NO BACKSTOP WITH BACKSTOP Manufacturer -25 F to 125 F -25 F to 125 F Manufacturer (-30 C to 50 C) (-30 C to 50 C) Cofran* S intogear 125 Shell* Omala* RL 100 Mobil* SHC* 629 Shell* Omala* HD 150 Never mix synthetic oil and mineral oil. CAUTION Never use extreme pressure (EP) oil in a reducer with a backstop. ACCEPTABLE MINERAL OIL LUBRICANTS -4 F to 14 F 14 F to 122 F(-10 C to 50 C) 122 F and Above Manufacturer (-20 C to 10 C) NO BACKSTOP WITH BACKSTOP (50 C +) ISO VG 68 ISO VG 100 ISO VG 150 ISO VG 220 ISO VG 150 ISO VG 320 Co fran* Mecanep 68 GL Cofraline Equitex 100 Mecanep 150 Equilux C2000 Super Cofrapoid 80W 90 Mecanep 320 Mo bil* Mobil* Gear 626 Mobil* Gear 627 Mobil* Gear 629 Mobil* Gear 630 DTE* Extra Heavy Mobil* Gear 632 Sh ell* Omala* 68 Omala* 100 Omala* 150 Omala* 220 Morlina* 150 Omala* 320 OIL CAPACITIES (U.S. QUARTS) Gear Frame 30 31 32 33 34 35 Reduction Stages Any 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 B3 0.37 0.63 0.63 0.26 1.00 1.00 0.95 1.69 1.69 2.09 3.49 3.49 3.38 5.49 5.49 B5 0.37 0.63 0.63 0.26 1.00 1.00 0.95 1.69 1.69 2.09 3.49 3.49 3.38 5.49 5.49 B6 0.53 1.00 1.30 0.63 1.85 2.43 1.48 3.49 4.62 3.25 7.40 7.40 6.34 13.21 13.21 B7 0.53 0.90 0.90 0.63 1.64 1.64 1.48 3.12 3.12 3.33 4.97 4.97 5.28 8.77 8.77 B8 0.74 1.16 1.16 1.06 2.38 2.38 2.01 4.76 4.76 4.42 7.08 7.08 7.71 13.95 13.95 B52 0.53 1.00 1.30 0.63 1.85 2.43 1.48 3.49 4.62 3.25 7.40 7.40 6.34 13.21 13.21 ** B53 0.74 1.16 1.16 1.06 2.38 2.38 2.01 4.76 4.76 4.42 7.08 7.08 7.71 13.95 13.95 B54 0.53 0.90 0.90 0.63 1.64 1.64 1.48 3.12 3.12 3.33 4.97 4.97 5.28 8.77 8.77 V1 0.58 1.22 1.22 0.69 2.38 2.38 2.22 4.76 4.76 4.05 7.93 7.93 6.13 15.53 15.53 V3 1.06 1.48 1.48 1.27 2.85 2.85 2.22 4.65 4.65 3.15 7.93 7.93 8.03 14.48 14.48 V5 0.58 1.22 1.22 0.69 2.38 2.38 2.22 4.76 4.76 4.05 7.93 7.93 6.13 15.53 15.53 V6 1.06 1.48 1.48 1.27 2.85 2.85 2.22 4.65 4.65 3.15 7.93 7.93 8.03 14.48 14.48 * The terms used in the above tables are the trade names, trademarks, and/or registered trademarks of the respective owners, are used herein for comparison or reference, and are not the property of, controlled by, or affiliated with Emerson Power Transmission Manufacturing, L.P. ** Refer to illustration below for fill level in all positions of size 30. Mounting Postitions Primary Gear Input Opening Orient the gear head vertically and fill to mid-point of the Primary Gear DIAGRAM FOR SIZE 30 OIL LEVEL Disconnect all power before adjusting units. 8 Emerson Power Transmission Manufacturing, L. P. or affiliates 2005. All rights reserved.