MACHINE ROOM-LESS ELEVATOR

Similar documents
Hitachi Elevator VFI-II

Vertical Dreams XJ SIEMENS. Vertispace Cargo Elevator. English. Deutsch. 中文 Français

Installation plan and power facility plan for Taiwan

Elvoron Home Elevator

ELVORON HR DESIGN AND PLANNING GUIDE

IRIS enhancing the value of the building...

GFC-L3 ADVANCED TECHNOLOGIES. The Best Helper to Enhance the Efficiency of your Modern Factory GFC-L3. Comfort. Efficiency. Safety.

Creating An Accessible World ELVORON CPL.

ELVORON HOME ELEVATOR

Passenger Elevator with Machine Room

Home Elevator. Planning Guide

TABLE OF CONTENTS. Contractor Notes 2. Specifications for Symmetry 3-4 Residential Elevator. Typical Hoistway Configurations 5-7

Hitachi Machine Room-less Elevator. Model UAG Series 2T

I N D I A N S T A T I S T I C A L I N S T I T U T E

Vertical Dreams XJ SIEMENS. Optima MRL Elevators. English. Deutsch. 中文 Français

Elvoron CPL. Planning Guide

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

Schindler 7000 Planning parameters of high-rise elevators.

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR.

ELEVATOR & ESCALATOR SYSTEMS. SHENYANG AMTE INDUSTRIES LLC Add.: No. 135, Changjiang Street, Huanggu District, Shenyang, China.

INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER

U.S.A / CANADA. USA CNS Automation, Inc E. Firestone Blvd. La Mirada, CA Tel : Fax :

Machine-Room-Less Elevator

Midrise Elevator. MRL MR Gearless MR Geared. Elevator Technology (Korea) Export Division

Comfort. Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Features: 1 Compact, Energy Efficient Machine. 2 Controller. 3 Governor. 4 Door Control System. 5 Revolutionary Coated Steel Belts

Introduction. Lift and Escalator Safety and their Protection. Lifts and Escalators Mechanism in HK Lift System Escalator System

State-of-the-Art Factories For the Environment. For Product Quality. Certification

Eclipse Gearless Residential Elevators OWNER S MANUAL

ELEVATOR S GENERAL FUNCTIONS GUIDE

Built for every day, designed for any style.

HOSPITAL BED ELEVATORS

Your Elevator Partner

Introduction Ecology Safety and Comfort Car Designs 5 7 Hall Design Basic Specifications 9-10 Electrical Installation Entrance Layout Drawings

Home Elevator. Specifically engineered for residential applications

Built for every day, designed for any style.

PASSENGER ELEVATOR (COMPACT MACHINE ROOM SYSTEM) Series-AP Version2

TRIVIUM ENTER ANOTHER DIMENSION

Schindler Schindler Passenger Elevators

LINEAR DIFFUSERS AND BAR GRILLES

PASSENGER ELEVATOR (MACHINE-ROOM-LESS SYSTEM) Series-IP Version2

Installation Information 2009 Model 300 Dumbwaiter

RIDE QUALITY All you need is a hoistway

Your Elevator Partner

NIPPON GOODS & CAR LIFT

RIDE QUALITY. All you need is a hoistway

PASSENGER ELEVATORS (COMPACT MACHINE ROOM SYSTEM) Series-IP/AP Version 2 Series-IP

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM. Designed to European standards

REFERENCE STANDARD RS-18 ELEVATORS AND CONVEYORS REFERENCE STANDARD RS 18-1

PASSENGER ELEVATOR (MACHINE-ROOM-LESS SYSTEM) Series-IP Version2

Guide for Inspection of Elevators, Escalators, and Moving Walks

Built for every day, designed for any style.

Major Code changes MESA Continuing Education

SECTION VII METERING INSTALLATIONS

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM

GOING UP IN SPACE. KONE TranSys Passenger

Guide for Inspection of Elevators, Escalators, and Moving Walks

MACHINE ROOM-LESS FREIGHT AND SERVICE ELEVATOR. KONE TranSys

Design Guide ASME A18.1

Stannah Midilift SL/GL

Elevator Technology. uniq. Fact Sheet BO 61 F 00-40

Machine-room-less electrical gearless solutions (MRLG)

luxury & convenience home elevators by

Well dimensions are absolute min. plumbed dimensions. Shaft floor to be constructed in accordance to layout drawing

Elevator Technology. synergy 100. Fact sheet.

We care about your goods

NOTES ON ELEVATOR SYSTEMS

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM

DESCRIPTION OF OPERATION EcoSpace elevator with KCM831 control

LU/LA Elevators. Value: 1 contact hour (0.1 CEU) by Jay Dickens

Planning Guide. ThyssenKrupp. ThyssenKrupp Access Residential Elevator Division. for Residential Elevators ASME A17.1, Part V, Section 5.

EXPLOSION-PROOF ELECTRIC WIRE ROPE HOIST BWX

National Reach. Local Service.

PASSENGER ELEVATORS MACHINE-ROOM-LESS SYSTEM

END USER CATALOGUE LIFTS & COMPONENTS

SECTION HVAC POWER VENTILATORS

HOSPITAL BED ELEVATORS

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Elevator Technology. synergy. element package. Fact sheet.

MACHINE-ROOM-LESS FREIGHT AND SERVICE ELEVATOR. KONE TranSys

Elite RESIDENTIAL ELEVATOR. AmeriGlide Accessibility Solutions

GOING UP IN SPACE. KONE TranSys Passenger

RIDE QUALITY. All you need is a hoistway

NIDEC Elevator Rev. 2

C M Y CM MY CY CMY K

Ecology Using Energy Wisely 7 8. Standard Design 15. Features Basic Specifications (m/sec) (m/sec) 3.

DELAWARE ELE TOR

CHAPTER 4: ACCESSIBLE ROUTES


Opening Quality Doors Around The World. Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual)

ASTRON. Automobile Elevator Moving Solutions with safety and Reliability. MRL Machine Room Less ELEVIO

Piccolo. Vertical cabin platform lifts

LEA Standard. LEA - Family. Standard. Flexible. Comfort. Comfort Plus. Cargo. Home. Kits

Infinity & Infinity HD

Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Concord Dealer)

Goods lift with attendant. Goods only lift

Manufacturer, Installation & Service Of Residential Elevators

SECTION TRACTION ELEVATORS

PASSENGER ELEVATORS. Designed to European standards

Transcription:

MACHINE ROOM-LESS ELEVATOR Space-saving Elevator With this Machine Room-less elevator, the space could be saved and utilized effectively, thus maximizing rentable space and reducing construction cost for the customer. Energy-saving Elevator This model adopted a gear-less traction machine and the latest Insulated Gate Bipolar Transistor (IGBT) Technology to reduce the capacity of the motor and other electrical equipment, resulting in substantial savings in energy costs. The overhead dimensions have been reduced by using under-slung mechanism CAGE MAIN ROPE ENTRANCE SAFETY DEVICE GUIDE RAIL COUNTERWEIGHT The slim control panel has been developed which can be installed within elevator hoistway The slim type gear-less machine has been located at the side or the top of the elevator hoistway TRACTION MACHINE GOVERNOR CONTROL PANEL BUFFER 3 Machine Room-Less (UAG)

STANDARD CAR AND CEILING DESIGN For Passenger Ceiling : BS-11 Center : Milky white acrylic Surrounding : Lighting : LED Height (from floor) : 2300 mm. Front return/transom panel : Side and rear wall (3 sides) : Kick plate : Flooring : Vinyl tile Car door : LPS with trim Door sill : Extruded hard aluminum Ventilation : Air-blown through ceiling duct Car position indicator : Dot matrix, incorporated into car operating panel Operating panel : OPV-BAuD AS-1X (narrow) type Jamb Jamb frame : Door panel : LPS with trim Door sill : Extruded hard aluminum Hall button with indicator : VIB-12BAuø35D 4 Machine Room-Less (UAG)

For Bed Ceiling : BS-11 Center : Milky white acrylic Surrounding : Lighting : LED Height (from floor) : 2300 mm. Front return/transom panel : Side and rear wall (3 sides) : Kick plate : Flooring : Vinyl tile Car door : LPS with trim Door sill : Extruded hard aluminum Handrail : Flat type, Stainless steel hairline Ventilation : Air-blown through ceiling duct Car position indicator : Dot matrix, incorporated into car operating panel Operating panel : OPV-BAuD AS-1X (narrow) type Jamb Jamb frame : Door panel : LPS with trim Door sill : Extruded hard aluminum Hall button with indicator : VIB-12BAuø35D 5 Machine Room-Less (UAG)

Operating panel, Indicator series STANDARD Operating panel OPV-BAuD Operating panel Face plate Button type P14F-UL Indicator type Dot matrix OPTION Hall button Hall buttons & Indicators VIB-12BAuø35D Hall button with indicator Face plate Button type P14F-UL Indicator type Dot matrix Hall Indicator BL-76 Hall button Face plate Stainless Steel Hairline (SUS-H) Hall lanterns HF-119 Hall indicator Face plate Indicator type Dot matrix L-03 Hall lantern Face plate L-03DX Hall lantern with Indicator Face plate Indicator type Dot matrix Operating panel (For Handicapped) 6 Machine Room-Less (UAG) OPV-BYAu Face plate Indicator Type Dot Matrix BL-76 Hall button Face plate

List of standard designs and finishes Car Designs No. Item Finishes/ Designs/ Types 1 Ceiling BS-11 2 Car Wall (3 sides) 3 Front Return Panel & Car Transom Panel 4 Car Door LPS with Trim 5 Kickplate (3 sides) 6 Sill Extruded Hard Aluminum 7 Operating Panel Stainless Steel Hairline with Dot Matrix Indicator and Plastic Resin Button OPV-BAuD Entrance Designs No. Item Finishes/ Designs/ Types 1 Jamb Frame Narrow Type (AS-1X) Stainless Steel Hairline (SUS-H) 2 Sill Extruded Hard Aluminum 3 Door LPS with Trim 4 Hall Button and Indicator Incorporated Type Dot Matrix Indicator and Plastic Resin Button (VIB-12BAuø35D) 7 Machine Room-Less (UAG)

Designs and Colors Ceiling BED TYPE PASSENGER TYPE STANDARD BS-11 BS-11 OPTION DX-11 Designs for Car Doors / Entrance Doors 7170UN Metal Pearl Rosewood 2726NT Natural Beech 5261NT Sandy Sakura 5262UN White Sakura 5475SP Blondbrush Wood-Cross 9401UN Aluminium White 7171UN Metal Pearl Steel 7158UN Cosmic Dusk 7157UN Cosmic Dawn 0869NT Powdered Oak 8834NT Smoke Strand 6006UN Canadian Pine (Straight) Floor (Vinyl Tiles) GA 202 GA 203 SA 614 8 Machine Room-Less (UAG) GA 201 GA 205 SA 613 GA 204 SA 606 SA 605

FUNCTIONS S 9 Machine Room-Less (UAG)

FUNCTIONS No. Optional Function Description 6 Hall lantern Hall lanterns can be provided instead of hall indicators. (For 3 or 4 cars group control, hall lantern will be provided as basic feature) 7 Automatic bypass operation When the car is fully loaded, it will only respond to car calls and bypass all hall calls 8 Sub operating panel 9 Closed-circuit TV (CCTV) 10 Fire emergency operation 11 12 Emergency operation for power failure by building standby generator Automatic rescue device for power failure* Additional floor selection and door open/close buttons are located on the side opposite the main operating panel For monitoring of movement inside the car by security personnel. (camera, recorder cabling by others) In the event of fire, the elevator is automatically brought to the designated floor when it remains inoperative for passenger safety In the event of buidling power failure, the elevator can be operated by building standby generator to move it to the designated floor In the event of power failure, the system automatically changes over to batterry power to bring the elevator to the nearest floor OTHER FUNCTIONS 13 Elevator supervisory panel * These functions are not applicable to private lobby layout building Various supervisory operations, communication and status monitoring can be provided through either the conventional LED based type 10 Machine Room-Less (UAG)

Dimensions of Hoistway & Location Based on Japan Industrial Standard (JIS) regulation (non-fire rated door) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 11 Machine Room-Less (UAG)

Pit Reaction Loading Rated Load Rated speed Pit reaction loading (KN) No. Rated (kg) Load Persons m/s Rated (m/min) speed Model Car side Counter weight side No. Persons Model Car side Counter weight side (kg) m/s (m/min) RC1 RC2 RC3 RC4 RC5 RC5 RW1 RW1 RW2 RW3 1 450 6 1.0 (60) UAG-450-CO60 62 24 26 53 44 20 2 1.0 (60) UAG-600-CO60 73 25 29 61 48 20 3 600 9 1.5 (90) UAG-600-CO90 4 1.75 (105) UAG-600-CO105 87 26.5 30.5 73 49.5 21.5 5 1.0 (60) UAG-750-CO60 85 28 32 70 58 22 6 750 11 1.5 (90) UAG-750-CO90 7 1.75 (105) UAG-750-CO105 102 29.5 33.5 84 59.5 23.5 8 1.0 (60) UAG-900-CO60 96 31 35 78 60 24 9 900 13 1.5 (90) UAG-900-CO90 10 1.75 (105) UAG-900-CO105 115 32.5 36.5 94 61.5 25.5 11 1.0 (60) UAG-1000-CO60 102 32 36 81 62 24 12 1000 15 1.5 (90) UAG-1000-CO90 13 1.75 (105) UAG-1000-CO105 122 33.5 37.5 98 63.5 25.5 14 1.0 (60) UAB-750-2S60 77 64 15 750 11 1.5 (90) UAB-750-2S90 93.5 31 28.5 77 16 1.75 (105) UAB-750-2S105 94 17 1.0 (60) UAB-1000-2S60 87.5 67 18 1000 1.5 (90) UAB-1000-2S90 104.5 34 31 19 1.75 (105) UAB-1000-2S105 105 Please consult to Hitachi or local agent when above dimension is less than the minimum specified. 82.5 37 16.5 39 17 Dimensions for overhead clearance and pit depth No. Rated speed m/s (m/min) 1 1.0 (60) Model Minimum overhead (mm) Pit depth (mm) Rear CWT Side CWT Rear CWT Side CWT Maximum *1 3600 3900 1400 1650 2 1.5 (90) UAG 3850 4000 1400 1800 3 1.75 (105) 4000 4050 1450 1850 4 1.0 (60) 3600 1600 1800 5 1.5 (90) UAB 3850 1600 1800 6 1.75 (105) 4000 1650 1850 *1. If the pit depth is more than the maximum, please fill back to the maximum depth 2. If the sum of travel and overhead is less than 11100 mm, please consult HITACHI. 3. Maximum number of stops : 24 stops. 4. Maximum travel : 60 m. 5. Minimum floor to floor height : 2700 mm. 6. Please consult to HITACHI or local agent when above dimension is less than the minimum specified 7. If the ceiling design is EX-type, overhead shall added 250 mm. 12 Machine Room-Less (UAG)

Hoistway layout Passenger Type Bed Type Dimensions of Hoistway & Location Dimensions of Hoistway & Location Pit reaction loading 13 Machine Room-Less (UAG)

Electrical Information Wiring Diagram Shows the work to be done by others Pit lightings including wiring & piping to be provided by others (minimum 200 lux at floor level) Power socket outlet including wiring & piping in pit to be provided by others Item Main power supply (*1) Contents To install the facilities to ensure that power does not fluctuate outside the range of -10% to +5% of the normal voltage rating and to ensure that the unbalance factor of voltage does not exceed 5% Lighting power supply To provide lighting power supply for car lighting (*1) indicators and maintenance work Interphone To provide pipes and wiring located outside hoistway. To provide 12 interphone wires of 0.9 mm 2 / elevator Ventilation The temperature in the hoistway should be maintained below 40 C by provision of mechanical ventilation Pit inspection receptacle AC 200 V 10A power outlet and pit lighting with switch for maintenance shall be provided below the entrance floor level (*1) Main and lighting supply shall lead into the hoistway at the lowest landing level Work to be done by building contractors The preparatory work for elevator installation outlined below should be undertaken by building contractors in accordance with Hitachi drawings and applicable national or local or relevant codes and regulations 1. Prepare hoistway with proper framing and enclosure, suitable pit of proper depth with drains and water proofing if required. 2. Provide and/ or cut all necessary holes, chasing, and openings and making good after equipment installation 3. Supply and secure all supports, reinforced concrete slabs, etc, necessary for installation of the machinery, doors, buffers, etc. 4. Provide all grouting works for entrance jamb frames, sills, hall buttons, indicator, brackets, bolts, 5. Prepare and erect suitable scaffolding and protective measures for the work in progress machine beam, etc. 6. Furnish mains for three-phase electric power and single-phase for car lighting supply and lift pit lighting and power outlet to the hoistway, following the instructions of the elevator contractor on outlet position 7. Provide, free of charge, a suitable theft-proof storage area of materials and tools during erection work. 8. Supply electric power for lighting of work area, installation work, elevator testing and spray painting 9. Hoisting hook 2 tonnes loading at top of the hoistway 10. Hoistway ventilation to be provided to maintain the hoistway temperature at below 40 c 14 Machine Room-Less (UAG)

15 Machine Room-Less (UAG)