Drive System Application

Similar documents
Drive System Application

Application for Drive Technology

Safety Integrated for entry level personnel SINAMICS. SINAMICS G converters Safety Integrated for entry level personnel. Hazards in plants and

Connection of F-DQ to F-DI of SINAMICS

Small step, big impact: Energy efficiency and dynamic performance

3RW Soft Starters. General data. 6/4 Siemens LV

The easy, high-performance and safe servo drive system usa.siemens.com/sinamics-s210

For Operation in the Control Cabinet 3RW Soft Starters

SINAMICS GM150 IGCT version

Errors with S1/S2/S3/S4 Safety cards

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008

SINAMICS G120 Inverter chassis units 0.37 kw to 132 kw (0.5 hp to 200 hp)

Sense7-series Non-contact coded safety switch

Closed-loop torque control and load distribution

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Manual. Brake Diagnostics (as of V ) * _0415* Phone: Fax: Web: -

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

SINAMICS G120. Inverter chassis units 0.37 kw to 90 kw Supplementary system components Basic Operator Panel BOP. Supplementary system components

FAQ about Drives Technologie

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Welcome to the presentation about safety functions of ACS880 functional safety, FSO- 12 Safety functions module.

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Versatile. Powerful. Space-saving. siemens.com/et200sp-motorstarter

DALI 650mA LED Driver

Description AX5806. List of permissible motors. Version: Date:

Volume CHARGESTORM AB. Charging station model EVA Start and Protected. User Manual Start & Protected

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

SIRIUS Soft Starters Introduction

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

650mA Phase Dimmable LED Driver

Tina 10A/B/C Adaptor unit

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Tina 11A Connection block

Industrial Controls. Load Feeders. SIRIUS - SIRIUS 3RA Load Feeders. Gerätehandbuch. Siemens Controls 09/2016. Edition. siemens.

Tina 4A Connection block

Siemens AG SIMOTICS T-1FW3 Torque Motors. The Powerful Torque Motors. Edition February Brochure. siemens.

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

SINAMICS DCC Winder V4.2.

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

System configuration SINAMICS G120P and SINAMICS G120P Cabinet pump, fan, compressor converters

TRIPS AND FAULT FINDING

INDUS rail /

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Planning information SIMODRIVE 611/POSMO

FMC-1/2 Tina Muting unit

Converting Applications Made Easy Presented by Jeff Reese Manufacturing in America March 14-15, 2018

Air Circuit Breakers

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Comprehensive solution with SIHARBOR

SIRIUS Soft Starters: Protection of motors and mechanics, reduced load on the mains SIRIUS. Answers for industry.

Based on the findings, a preventive maintenance strategy can be prepared for the equipment in order to increase reliability and reduce costs.

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

Siemens AG Modern design and easy handling for charging at home or in the semi-public area

ST Wiring diagram. Product description. Temperature controller. Order number

Introduction The aim of this application note is to outline how to configure an ACSM1 drive to run with an ABB BSM series AC servo motor.

Volume CHARGESTORM AB. Charging station model EVA Connected. User Manual Connected

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

Short Form Catalogue 2011

Innovations in SINAMICS Drives and SIMOTICS Motion Control Motors Presented by Randy Summervill Manufacturing in America March 14-15, 2018

Drive technology for the chemical industry. chemical INDUSTRY

1000mA - 650mA Phase Dimmable LED Driver

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

ZE motor-protective relay Overload monitoring of EEx e motors

NHP SAFETY REFERENCE GUIDE

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

Application Note: Protection of Medium-Power Motors With SIPROTEC Compact 7SK80

Air Circuit Breakers

Automation Days Radionica Motion Control

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection

Reliably Switching Highest Currents up to 2000 A

SIMOTICS S-1FT7 Servomotors. The Compact Servomotors for High-Performance Motion Control Applications. Motors. Edition April 2017.

Installation Instructions. Y-Series Brushless Servo Motor

PROPOSAL FOR STORAGE CONNECTION REQUIREMENTS

BYD B-Box Limited Warranty Letter

Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180

IES GRID FEED-IN LIMITER

Low-Voltage Motors N-compact Standardline Operation on supply system

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

Wind Power Inverter WINDY BOY 5000A/6000A

micromaster Catalog DA MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw

* _1217* Drive Technology \ Drive Automation \ System Integration \ Services. Catalog. AC Motors DRN80 315

RVS-DN Digital Reduced Voltage Motor Starter

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

Operation manual. ABS 911 GT3 Cup Gen.II MTH Version _V1_2018/02

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

EStrong-series Emergency Stop

TPM + Bosch Rexroth IndraDrive. Quick Startup Guide D Revision: 02

Electrical Engineering Info

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Pitch Systems. Siemens AG All Rights Reserved.

Small Wind Energy - International Standards. Small Wind Energy International Standards. Overview

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Safety Sensor CSS 180 Product Information

Miniature Circuit-Breakers (MCBs)

SINAMICS Drives SINAMICS G120E. Configured enclosed drive for industry Technical Data Sheet April, usa.siemens.com/drives

DRAFT PROPOSAL FOR STORAGE CONNECTION REQUIREMENTS

HAT220A ATS CONTROLLER USERS MANUAL

Transcription:

Drive System Application Example to calculate the limit values for SS1 and SLS Application description for SINAMICS G120

Warranty, liability and support Note The Application Examples are not binding and do not claim to be complete regarding the circuits shown, equipping and any eventuality. The Application Examples do not represent customer-specific solutions. They are only intended to pro-vide support for typical applications. You are responsible in ensuring that the de-scribed products are correctly used. These Application Examples do not relieve you of the responsibility in safely and professionally using, installing, operating and servicing equipment. When using these Application Examples, you recognize that Siemens cannot be made liable for any damage/claims beyond the liability clause described. We reserve the right to make changes to these Application Examples at any time without prior notice. If there are any deviations between the recommendations provided in these Application Examples and other Siemens publications - e.g. Catalogs - then the contents of the other documents have priority. Warranty, liability and support We do not accept any liability for the information contained in this document. Any claims against us - based on whatever legal reason - resulting from the use of the examples, information, programs, engineering and performance data etc., described in this Application Examples shall be excluded. Such an exclusion shall not apply in the case of mandatory liability, e.g. ander the German Product Liability Act ( Produkthaftungsgesetz ), in case of intent, gross negligence, or injury of life, body or health, guarantee for the quality of a product, fraudulent concealment of a deficiency or breach of a condition which goes to the root of the contract ( wesentliche Vertragspflichten ). However, claims arising from a breach of a condition which goes to the root of the contract shall be limited to the foreseeable damage which is intrinsic to the contract, unless caused by intent or gross negligence or based on mandatory liability for injury of life, body or health The above provisions does not imply a change in the burden of proof to your detriment. Copyright 2007 Siemens A&D. It is not permissible to transfer or copy these Application Examples or excerpts of them without first having prior authorization from Siemens A&D in writing. If you have any recommendations relating to this document then please send them to us at the following e-mail address: mailto:sdsupport.aud@siemens.com Version 1.1 Issue February 2007 2/13

Preposition Preposition Aim of the application This application was generated in order to give users the opportunity of being able to calculate the limit values for the SLS and SS1 safety functions. This application shows how this calculation should be correctly made in order to avoid safety fault/error messages and to guarantee the maximum availability of the drive. Scope The following core issues are discussed in this application: General information to calculate the limit values for SLS and SS1 Example to calculate the limit values for SLS and SS1 Exclusion This application does not include a description of the following: Commissioning safety functions Possible applications Handling safety functions It is assumed that readers have a basic knowledge about these subjects. Reference to the Automation and Drives Service & Support This article is from the Internet Application Portal of the Automation and Drives Service & Support. You can go directly to the download page of this document using this link. http://support.automation.siemens.com/ww/view/en/24488874 Version 1.1 Issue February 2007 3/13

Preposition Table of Contents Table of Contents... 4 Application description... 5 1 Overview and description of the functionality... 5 SLS - Safely-Limited Speed... 5 SS1 - Safe Stop 1... 5 STO - Safe Torque Off... 6 SBC - Safe Brake Control... 6 Information and restrictions... 6 2 Calculating the limit values for SS1 and SLS... 7 2.1 Parameterizing the envelope curve for SLS and SS1... 7 1. Upper tolerance range for the SLS P9691... 8 2. Resulting frequency tolerance Fhigh... 8 3. Resulting frequency tolerance Flow... 8 4. Delay Fdelay... 9 5. Minimum delay of the braking ramp... 9 3 Example: Calculating the safety formulas... 10 1. Upper tolerance range for SLS P9691... 10 2. Resulting frequency tolerance Fhigh... 11 3. Resulting frequency tolerance Flow... 11 4. Delay Fdelay... 12 5. Minimum delay of the braking ramp... 12 This means that the result of our calculation is as follows:... 12 Appendix and references... 13 4 References... 13 4.1 Reference data... 13 4.2 Internet link data... 13 4.3 History... 13 Version 1.1 Issue February 2007 4/13

Overview and description of the functionality Application description 1 Overview and description of the functionality The SINAMICS G120 is a modular drive inverter system that essentially comprises the two function units Control Unit (CU) and Power Module (PM). When using the CU240S DP-F Control Unit you can use the following safety-relevant functions integrated in the drive inverter: SLS - Safely-Limited Speed According to IEC 61800-5-2 The drive inverter monitors a set motor speed limit (upper limit) without requiring any additional external components Limits and monitors the drive speed Guarantees the shortest response times when a fault condition develops as a result of independent and continuous monitoring A speed encoder is not required SS1 - Safe Stop 1 According to IEC 61800-5-2 The drive inverter reduces the motor speed along a braking ramp down to standstill (zero speed) and continually monitors this braking operation without any additional external components The drive is quickly stopped, safely monitored Guarantees the shortest response times when a fault condition develops as a result of independent and continuous monitoring A speed encoder is not required Version 1.1 Issue February 2007 5/13

Overview and description of the functionality STO - Safe Torque Off According to IEC 61800-5-2 The drive inverter brings the drive into a safety-relevant torque-free condition The drive inverter protects the drive from accidentally starting (protection against restarting does not require electrical isolation between the motor and drive inverter). SBC - Safe Brake Control The drive inverter monitors the control of the electromechanical motor brake. The relay required for this function is available under Order No. [MLFB] 6SL3252-0BB01-0AA0. An external brake can be controlled in a safety-relevant fashion when using the Safe Brake Relay The safety-relevant functions are either controlled using two fail-safe digital inputs (4 digital inputs that are evaluated in the CU 240S DP F through two channels in a fail-safe fashion) or via PROFIsafe in conjunction with a failsafe CPU. Information and restrictions Please carefully note that the two SLS and SS1 safety-relevant functions cannot be used for loads that drive the motor or are permanently in the regenerative mode. A "load that moves the drive or is permanently regenerating" is involved if the motor, when in a no-voltage state, is accelerated by the load it normally drives (e.g. lifting equipment, winders, wind turbines). A perfectly functioning closed-loop control is a prerequisite for using the fail-safe functions. The drive (drive inverter + motor + driven load system) must be designed so that all of the operating cases associated with the particular application can be absolutely safely controlled and handled. After the STO and SS1 safety functions have been activated, there is no electrical isolation between the line supply connected to the SINAMICS G120 and the motor. If this electrical isolation is specified for your application then you must install an appropriate line contactor in front (upstream) of the SINAMICS G120. Version 1.1 Issue February 2007 6/13

Calculating the limit values for SS1 and SLS 2 Calculating the limit values for SS1 and SLS When parameterizing the SLS and SS1 safety functions, several limit values should be defined in the so-called envelope curve. To do this, all of the safety calculation formulas must be taken into account that help to avoid errors when parameterizing safety functions or to avoid resulting fault/error messages. This calculation is described in detail in the following. 2.1 Parameterizing the envelope curve for SLS and SS1 When parameterizing the envelope curve for SLS and SS1, the following minimum tolerances should be observed with P9680/P9880 and P9691/P9891 in order to guarantee the maximum availability of the drive. Figure 2-1 Safety limits for SLS and SS1 Version 1.1 Issue February 2007 7/13

Calculating the limit values for SS1 and SLS 1. Upper tolerance range for the SLS P9691 The upper tolerance range for the SLS P9691 should be set to P9691 1.15 P9690 + Fslip This is means that the minimum frequency tolerance is defined as F = P9691 - P9690 Fslip whereby Fslip = r0330 P0310 This parameterization prevents failures due to measuring errors. It should be noted that P9691 must be set if SLS was not parameterized. 2. Resulting frequency tolerance Fhigh The resulting frequency tolerance Fhigh is, due to the minimum frequency tolerance at high frequencies, given by: Fhigh 0.15 Fmax - F whereby Fmax is defined to be the maximum frequency when initializing SLS or SS1. 3. Resulting frequency tolerance Flow The resulting frequency tolerance Flow is, due to the minimum frequency tolerance at low frequencies, given by: Flow m / D - F Whereby gradient m is defined as m = 200 / P9681 The value for D in the formula above is calculated as follows: SLS parameterized: D = 2 P9690 SS1 parameterized: D = 2 P9682 SLS and SS1 parameterized: D = 2 min [P9682, P9690] Version 1.1 Issue February 2007 8/13

Calculating the limit values for SS1 and SLS 4. Delay Fdelay The valid delay Fdelay is given as a maximum of Fdelay = max [0, Flow, Fhigh] 5. Minimum delay of the braking ramp The minimum delay of the braking ramp can be calculated using P9680 Fdelay / m The envelope curve for SS1 and SLS is obtained from a time delay (P9680) in the t direction and an additional frequency tolerance F in the F direction. Version 1.1 Issue February 2007 9/13

Example: Calculating the safety formulas 3 Example: Calculating the safety formulas The safety formulas for a 1LA7060-4AB10-Z motor and for the factory settings of the safety parameters are calculated in the following example. The technical motor data and the values to calculate the required safety parameters are listed in the following tables. Table 3-1 Technical data Parameter Parameter text Value P0300 Selects the motor type 1; induction motor P0304 Rated motor voltage 230/400 [V] /Y P0305 Rated motor current 0.73/0.42 [A] P0307 Rated motor power 0.12 [kw] P0308 Rated motor power factor 0.75 P0310 Rated motor frequency 50 [Hz] P0311 Rated motor speed 1350 [rpm] r0313 Motor pole pair number 2 Table 3-2 Factory settings of the safety parameters Parameter Parameter text Value P9681 SI braking ramp, ramp-down time 10 [s] P9682 SI minimum speed to detect 5.0 [Hz] standstill (zero speed) P9690 SI setpoint for SLS 10.0 [Hz] 1. Upper tolerance range for SLS P9691 The slip frequency is calculated from: Fslip = r0330 P0310, whereby r0330 is the rated motor slip r0330 = (P0310 - P0311 r0313 / 60) / P0310 100% Fslip = (50 [Hz] - 1350 [rpm] 2 / 60) / 50 [Hz] 100% 50 [Hz] = 5 [Hz] or 10 [%] of 50 [Hz] (P2000 = 50 [Hz]); The upper tolerance range for SLS P9691 is therefore: Version 1.1 Issue February 2007 10/13

Example: Calculating the safety formulas P9691 1.15 P9690 + Fslip, or P9691 1.15 10 [Hz] + 5 [Hz], P9691 16.5 [Hz]; Here, parameter P9691 should be selected, e.g. P9691 = 16.5 [Hz] (or 17 [Hz]). The minimum frequency tolerance is calculated from: F = P9691 - P9690 Fslip or F = 16.5 [Hz] - 10 [Hz] - 5 [Hz] = 1.5 [Hz] 2. Resulting frequency tolerance Fhigh The formula to define the upper frequency tolerance Fhigh is as follows: Fhigh 0.15 Fmax - F; If e.g. Fmax = 50 [Hz], then the following is obtained: Fhigh 0.15 50 [Hz] 1.5 [Hz], Fhigh 6 [Hz] 3. Resulting frequency tolerance Flow The formula to determine the lower frequency tolerance Flow is: Flow m / D - F Gradient m is calculated as follows: m = 200 / P9681 = 200 [Hz] / 10 [s] = 20 [Hz/s] The value D for - SLS parameterized - SS1 parameterized - D = 2 P9690 = 2 10 [Hz] = 20 [Hz] D = 2 P9682 = 2 5 [Hz] = 10 [Hz] SLS and SS1 parameterized - D = 2 min [P9682, P9690] = 2 min [5 [Hz], 10[Hz]] = 10 [Hz] Now - considering the case if both functions, SLS and SS1 are parameterized. Version 1.1 Issue February 2007 11/13

Example: Calculating the safety formulas In this case, the formula of the resulting frequency tolerance Flow is given by: Flow m / D - F, Flow 20 [Hz/s] / 10 [Hz] - 1.5 [Hz], Flow 0.5 [Hz] 4. Delay Fdelay Please note that Flow and Fhigh can assume both negative values as well as also 0. It is therefore important to compare Fdelay with 0 and to determine the maximum value. The formula is as follows: Fdelay = max [ Flow, Fhigh, 0] = max [0.5 [Hz], 6 [Hz], 0] = 6 [Hz] 5. Minimum delay of the braking ramp The minimum delay of the braking ramp is calculated as follows: P9680 Fdelay / m, P9680 6 [Hz] / 20 [Hz/s], P9680 0.3 [s] Parameter P9680 should be parameterized to 300 [ms]. This means that the result of our calculation is as follows: The upper tolerance range P9691 = 16.5 [Hz] The minimum delay of the braking ramp P9680 = 300 [ms] Version 1.1 Issue February 2007 12/13

Appendix and references References 4 References 4.1 Reference data Appendix and references This list is in no way complete and only reflects a selection of suitable references. Table 4-1 Subject area /1/ SINAMICS G120 Operating Instructions /2/ SINAMICS G120 parameter list Title Operating Instructions: Control Unit CU240S, CU240S DP, CU240S DP-F Software version 2.0 Parameter Manual: Control Unit CU240S, CU240S DP, CU240S DP-F Software version 2.0 /3/ Manual Safety Integrated /4/ Getting Started SIMATIC S7 Distributed Safety 4.2 Internet link data This list is in no way complete and only reflects a selection of suitable references. Table 4-2 Subject area Title \1\ Web page Siemens A&D Customer Support \2\ Application SINAMICS G120 - controlled via Profibus Safety functions using Profisafe, Category 3 (EN 954-1) or SIL 2 (IEC 61508) \3\ Application Commissioning SINAMICS G120 Safety- Integrated features with Starter \4\ FAQ Fault F0395 "Acceptance test" 4.3 History Table 4-3 History Version Date Change V1.0 Januar 2007 First edition V1.1 February 2007 Excel spreadsheet (calculation of the limiting values) added Version 1.1 Issue February 2007 13/13