Sentinel D-Box Single Fan

Similar documents
Sentinel D-Box Twin Fan

NEW Slimpak EC Box Fan (SLPT EC)

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

NEW Acoustic In-Line Fans (ACQ)

Acoustic Twin Fans (ATQ)

Square Mixed Flow Fans (MFQ)

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH)

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR)

Performance. Sound Levels. Impellers. Motors. Accessories

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Bifurcated Case Axial Fans (BIFA)

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

IN-LINE CENTRIFUGAL DUCT FANS VT Series

BOX BLB Centrifugal Box Fan

HIGH TEMPERATURE TWIN SQUIF FANS

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Access Rectangular In-Line Fans (ARH)

ACOUSTIC CABINET FANS CVB / CVT Series

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

CENTRIFUGAL IN-LINE FANS VENT Series

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

QUBE SQU-HT(S) Product Brochure

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Uniclass L7534. Manufacture controlled to ISO9001

TWINFLOW STDR Product Brochure

ZOO FAN SDF Destratification Ceiling Mounted Fan

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery

Unobox units with backward curved centrifugal impellers

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

ACOUSTIC CABINET FANS CVAB / CVAT Series

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

Axial fans. What s more, non-stock models are normally available within two weeks.

MegaBox Product-specific information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

AC Commercial Fans Edition. ErP ready

ISEO IMF Product Brochure

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

GigaBox centrifugal fans Product specific information

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

SILENT MV Ultra Quiet In-line Fans

Sapphire Horizontal Waterside Control Fan Coil Units

BIFURCATED AXIAL FLOW FANS

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

MULTIFLOW SEL Product Brochure

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

REVOLUTION SLCX Product Brochure

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIRECT-AIR ILB / ILT Series Rectangular duct fans

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

QUIETSCROLL TWIN FAN RANGE

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

Plate mounted axial flow fans HXBR / HXTR Series

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

MAJAX-2 GENERAL SPECIFICATION

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Multifunctional 400ºC/2h and 300ºC/2h roof fans

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Transcription:

Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for Internal or External mounting Performance tested to BS848 parts 1 & 2 The Sentinel single in-line duct fans are as supplied from Vent-Axia Ltd. Manufactured from Aluzinc, Sentinel fan units are internally treated with an O class rated, BS476 part 6 & 7 acoustic foam which offers the benefits of high sound absorption, good thermal insulation properties, in addition to self extinguishing properties and resistance to ignition. Weatherproof external units incorporate an additional controller shroud. The casing includes an inclined inlet and bellmouth entry which directs the incoming air to the impeller with minimal turbulence. The result is better air management through the unit, less noise, higher efficiency and an increased performance. The housing is designed to be as compact as possible for concealed false ceiling applications and Sentinel casings are specially designed to allow the unit to be mounted via its unique mounting bracket, ensuring a quick and easy solution to installation. Impellers All Sentinel units feature a low energy, Class 1, EC/DC external rotor motor and backward curved impeller assembly specifically chosen for performance and non-overloading characteristics. The assembly is dynamically balanced to DIN ISO 194 Grade 6.3, duct size 5mm rated IP54, all other sizes IP44 according to BS EN 6529. Ball bearings are greased for life. Insulation is Class B (from - C to +6 C). All models incorporate internal electronic overload protection and soft start function. Motors are single phase 23V +/- 1% / 5/6Hz / 1ph (size - 4mm) or 4V +/- 1% / 5/6Hz / 3ph (size 5mm), (4 wire systems only). 24V DC power is provided from the controller for powering the matched range of Sentinel switches and sensors. Performance/Sound Extensively tested to BS848 parts 1 & 2. Published db(a) figures are free field sound pressure levels at 3m with spherical propagation at reference level of 2 x 1-5 Pa. The inlet/outlet sound power level spectra figures are db with a reference of 1 12 Watts. Weatherproof Typical Ordering Designation Ordering codes are similar to existing units with Suffix. /WP which denotes Weatherproof. Example: SENTS/CP/WP Accessories For duct accessories see Ducting and Fitting Section. Electrical Every Sentinel unit is fitted with a purpose designed common PCB controller incorporating a 16-character backlit alphanumerical x 2 line display with 4 button membrane keypad for fan status and commissioning set up. The enclosure is fitted with a 4-pole 1A isolator that is suitable for fitting a locking device to prevent accidental operation. 362

Fan Dimensions (mm) airflow h spigot C offset L c d e g a f b Constant Hierarchy Pressure Weight Model Model a b c d e f g h kg SENTS SENTS/CP 38 443 275 4 192 36 62 8.5 SENT1S SENT1S/CP 38 443 1 275 4 192 36 62 8.5 SENT15S SENT15S/CP 38 443 15 275 4 192 36 62 8.5 SENT2S SENT2S/CP 435 531 2 33 453 287 36 6 12.5 SENTS SENTS/CP 435 531 33 453 287 36 35 13 SENT315S SENT315S/CP 71 88 315 54 661 458 568 43 34 SENT4S SENT4S/CP 71 88 4 54 661 458 568 43 36 SENT5S SENT5S/CP 898 996 5 735 858 577 765 59 55 Accessories Anti-Vibration *Duct Hierarchy Mounts Duct air heater Filter cassette Bag filter cassette attenuator 6mm Model Model Stock Ref Stock Ref Stock Ref Stock Ref Stock Ref SENTS SENTS/CP 68MP33G 1531T1 1532A 1533 1535 SENT1S SENT1S/CP 68MP33G 15311T1 15321A 15331 15351 SENT15S SENT15S/CP 68MP33G 153115T1 153215A 153315 153515 SENT2S SENT2S/CP 68MP33G 15312T1 15322A 15332 15352 SENTS SENTS/CP 68MP33G 1531T1 1532A 1533 1535 SENT315S SENT315S/CP 68MP33G 1531315T1 1532315A 1533315 1535315 SENT4S SENT4S/CP 68MP33G 15314T3 15324A 15334 15354 SENT5S SENT5S/CP 68MP33G 15315T3 153A 15335 15365* *For alternative attenuator lengths, refer to Accessories and Controllers section 363

Sentinel Single Fan 6.18 5.15 4.12 3 2 4 %.9.6 8% 5%.3.2.4.6.8.1.12.14 m 3 /s @ Pa Speed Motor Phase 5 2 3 4 5 F.L.C Amps m³/s.4 1 SFP.18.8 Watts.1 m³/s.7.6.4 5 1 SFP.29.33.5.15 Watts.2.2.2 m³/s.11.1.9.7.4 8 1 SFP.42.47.52.66 1.13.5 Watts.5.5.5.5.5 m³/s.13.12.11.9.7.5.3 1 SFP.62.68.74.9 1.16 1.6 2.53.72 Watts.8.8.8.8.8.8.8 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 44 39 35 27 24 22 23 29 17 Inlet 43 43 4 35 26 22 22 29 19 Outlet 46 4 41 35 29 23 22 3 2 Breakout 5 48 47 37 32 29 26 3 23 5 Inlet 48 52 62 54 41 34 28 3 35 Outlet 49 52 67 57 48 44 38 31 39 Breakout 55 58 56 48 42 41 38 33 31 8 Inlet 55 58 67 67 53 47 41 35 45 Outlet 56 59 68 68 61 56 51 42 47 Breakout 64 63 6 55 47 46 44 38 36 Inlet 57 62 68 71 58 52 47 41 48 Outlet 57 63 71 72 66 62 55 48 52 364

6 Sentinel 1 Single Fan.9 5 4 % 4.6 3 2 8%.3 5%...5.1.15.2 Speed Motor Phase 5 2 3 4 5 F.L.C Amps m³/s.5 1 SFP.14.9 Watts.1 m³/s.9.7.5 5 1 SFP.21.27.38.18 Watts.2.2.2 m³/s.14.13.11.9.6.2 8 1 SFP.35.39.47.58.83 2.2.51 Watts.5.5.5.5.5.4 m³/s.16.15.14.11.9.7.4 1 SFP.51.54.58.75.92 1.17 2..72 Watts.8.8.8.8.8.8.8 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 49 4 34 28 26 24 23 29 18 Inlet 46 44 41 35 27 22 22 28 2 Outlet 47 47 42 36 33 27 22 29 21 Breakout 53 49 49 39 34 28 23 29 24 5 Inlet 5 56 58 53 43 37 31 29 33 Outlet 5 56 58 53 43 37 31 29 37 Breakout 55 55 58 5 46 39 31 31 33 8 Inlet 54 64 68 64 55 49 43 36 44 Outlet 56 67 72 66 64 6 55 45 49 Breakout 62 58 59 57 52 46 37 33 37 Inlet 58 69 7 7 6 56 48 42 49 Outlet 58 7 71 73 7 67 6 52 54 365

Sentinel 15 Single Fan 7.14 6.12 5.1 4 4 %.8 3 2 8%.6.4 5%.2..2.4.6.8.1.12.14.16.18 Speed Motor Phase 5 2 3 4 5 F.L.C Amps m³/s.5 1 SFP.14.8 kw.1.1 m³/s.1.8.6 5 1 SFP.19..35.16 kw.2.2.2 m³/s.15.14.12.1.6.1 8 1 SFP.31.34.41.51.85 4.5.48 kw.5.5.5.5.5.5 m³/s.17.16.15.12.1.7.4 1 SFP.47.51.54.68.81 1.16 2..74 kw.8.8.8.8.8.8.8 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 46 43 36 28 26 23 24 29 18 Inlet 46 45 42 37 3 24 23 29 21 Outlet 43 45 42 37 35 31 22 28 22 Breakout 5 5 5 4 35 28 24 29 5 Inlet 5 56 6 56 46 41 36 3 35 Outlet 51 59 61 56 53 51 46 33 38 Breakout 53 57 57 51 48 42 36 31 33 8 Inlet 57 65 71 66 58 52 44 42 46 Outlet 56 67 75 67 65 63 56 5 5 Breakout 62 61 59 6 54 49 43 37 39 Inlet 59 68 72 76 64 58 51 48 54 Outlet 59 7 74 76 71 7 64 58 56 366

8 Sentinel 2 Single Fan.2 7 4 % 6.15 5 4 3 8%.1 2.5 5%...5.1.15.2..3 Speed Motor Phase 5 2 3 4 5 6 7 F.L.C Amps m³/s.6 1 SFP.13.8 kw.1 m³/s.14.11.8 5 1 SFP.19..34.16 kw.3.3.3 m³/s.22.2.18.13.9.4 8 1 SFP.37.42.46.65.88 2.5 kw.8.8.8.8.8.8 m³/s.28.26..21.18.14.11.7.2 1 SFP.54.61.65.8.93 1.2 1.54 2.41 7.75.72 kw.15.16.16.17.17.17.17.17.16 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 48 41 39 3 29 26 24 31 2 Inlet 5 52 49 43 34 32 24 3 26 Outlet 46 55 48 43 39 42 29 3 28 Breakout 55 53 55 42 41 37 34 32 29 5 Inlet 54 57 67 62 51 44 47 4 41 Outlet 55 59 67 62 58 56 55 46 44 Breakout 66 63 63 52 47 46 45 44 37 8 Inlet 63 66 68 77 64 57 56 53 54 Outlet 65 68 66 76 71 69 65 61 56 Breakout 63 69 66 6 53 51 5 5 42 Inlet 68 71 72 77 7 63 61 57 56 Outlet 7 72 69 8 76 76 72 65 62 367

7 Sentinel Single Fan.28 6.24 5.2 4 3 2 8% 4 %.16.12.8.4 5%..5.1.15.2..3..35 Speed Motor Phase 5 2 3 4 5 6 F.L.C Amps m³/s.7 1 SFP.11.7 kw.1 m³/s.15.11.7 5 1 SFP.15.22.34.2 kw.2.2.2 m³/s.24.22.19.13.7 8 1 SFP.26.3.36.52 1 1 kw.6.7.7.7.7 m³/s.33.3.28.24.19.15.9.1 1 SFP.37.44.49.59.77.97 1.48 3.7 1.38 kw.12.13.14.14.15.15.13.4 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 42 42 37 31 29 26 31 19 Inlet 48 49 42 38 35 24 24 29 22 Outlet 47 46 41 37 41 29 24 29 24 Breakout 52 48 53 43 37 36 34 3 27 5 Inlet 55 57 65 58 49 43 45 38 39 Outlet 53 57 62 58 54 55 51 36 41 Breakout 54 56 57 57 48 46 45 36 36 8 Inlet 63 65 69 76 62 54 53 49 53 Outlet 63 66 69 72 69 68 62 55 54 Breakout 61 63 62 62 55 54 52 45 42 Inlet 68 71 72 8 68 62 59 56 58 Outlet 68 71 7 78 75 75 68 63 6 368

Sentinel 315 Single Fan 6.3 5. 4.2 3 2 8% 4 %.15.1.5 5%..5.1.15.2..3.35.4.45.5.55.6 Speed Phase 5 2 3 4 F.L.C Amps m³/s.12 1 SFP.6.8 kw.1 m³/s.26.17.6 5 1 SFP.1.16.42.19 kw.3.3.3 m³/s.44.39.32.18 8 1 SFP.18.21.26.46.5 kw.8.8.8.8 m³/s.57.53.48.37.26.15 1 SFP.27.3.34.44.62 1.9 1.36 kw.15.16.16.16.16.16 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 45 42 44 32 3 26 31 21 Inlet 47 43 4 31 28 22 23 29 19 Outlet 47 44 42 37 33 27 29 21 Breakout 54 56 48 46 36 3 26 31 27 5 Inlet 61 63 54 47 44 39 32 3 31 Outlet 6 63 55 55 51 49 42 31 37 Breakout 57 68 6 49 45 42 36 32 38 8 Inlet 62 78 67 59 55 51 45 4 44 Outlet 62 82 68 66 64 61 55 46 5 Breakout 62 69 69 56 53 47 43 36 44 Inlet 67 78 79 66 61 58 53 45 51 Outlet 66 78 78 73 7 68 63 55 56 369

Sentinel 4 Single Fan 8.8 7.7 6.6 5.5 4 3 2 4 % 8%.4.3.2.1 5%..1.2.3.4.5.6.7.8.9 1. Speed Phase 5 2 3 4 5 6 F.L.C Amps m³/s.24 1 SFP.7.13 kw.2 m³/s.5.42.32 5 1 SFP.14.19..59 kw.7.8.8 m³/s.74.71.65.51.37.19 8 1 SFP.27.29.33.43.58.96 1.8 kw.2.21.21.22.21.18 m³/s.95.9.85.75.64.52.38.2 1 SFP.42.45.49.58.69.84 1.9 1.79 2.47 kw.4.41.42.44.44.44.42.36 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 44 4 46 35 29 26 24 31 21 Inlet 5 48 48 39 3 23 24 3 23 Outlet 51 48 47 42 38 28 29 Breakout 56 68 54 45 41 34 26 3 33 5 Inlet 69 74 65 56 52 48 38 33 41 Outlet 68 72 65 62 61 57 48 39 45 Breakout 63 73 68 57 52 44 38 32 42 8 Inlet 74 82 78 68 64 61 56 47 53 Outlet 75 87 77 75 73 7 64 55 58 Breakout 67 73 76 63 58 5 44 4 48 Inlet 78 83 87 73 69 66 61 54 59 Outlet 78 85 92 8 79 75 69 61 65 37

8 Sentinel 5 Single Fan 1.6 7 1.4 6 1.2 5 1. 4 3 2 4 % 8%.8.6.4 5%.2..2.4.6.8 1 1.2 1.4 1.6 Speed Phase 5 2 3 4 5 6 7 F.L.C Amps m³/s.46.23 3 SFP.8.18.21 kw.4.4 m³/s.89.76.65.39 5 3 SFP.18.21.27.42.67 kw.16.16.17.16 m³/s 1.39 1.26 1.17.99.85.63.32 8 3 SFP.3.34.36.46.56.76 1.4 1.6 kw.41.43.42.45.47.48.45 m³/s 1.6 1.49 1.41 1.27 1.15 1.2.88.71.41 3 SFP.46.49.53.62.73.86 1.1 1.19 1.6 2.1 kw.74.73.74.79.84.88.89.85.66 Speed Test Mode 63 1 5 1k 2k 4k 8k db(a) @ 3m Breakout 57 49 43 36 42 26 33 Inlet 69 55 47 45 42 29 32 29 Outlet 68 56 53 5 49 39 31 32 33 Breakout 65 69 6 51 48 37 31 32 36 5 Inlet 7 78 67 63 53 49 42 41 45 Outlet 7 76 7 68 65 6 52 46 49 Breakout 69 78 71 61 57 49 42 42 46 8 Inlet 75 89 78 74 64 61 54 48 56 Outlet 76 86 83 8 77 71 66 59 62 Breakout 7 79 75 66 61 52 47 43 49 Inlet 77 86 83 77 68 64 58 53 58 Outlet 78 87 84 83 79 73 69 61 64 371