Powerturn IS/TS Powerturn F-IS/TS Powerturn F/R-IS/TS. EN Installation instructions

Similar documents
Powerturn IS-Mechanism. EN Installation instructions

Ball-bearing sliding door gears. GEZE Perkeo. BMW Niederlassung Stuttgart

GEZE RWA AND VENTILATION TECHNOLOGY CRANKED TURN-AND-TILT HARDWARE GEZE F 1200 EASE OF USE FOR LARGE AND HEAVY WINDOWS BEWEGUNG MIT SYSTEM

GEZE door technology. The ball bearing sliding door system

GEZE Door closer systems

G E Z E G L A S S S YS T E M S INTEGRATED ALL-GLASS SYSTEMS GEZE IGG INTELLIGENCE BET WEEN THE PANES B E W E G U N G M I T S Y S T E M

GEZE E 580, E E 680

GEZE DOOR CLOSER SYSTEMS OVERVIEW OF GEZE DOOR CLOSER SYSTEMS OVERHEAD AND INTEGRATED DOOR CLOSERS, AND FLOOR SPRINGS BEWEGUNG MIT SYSTEM

GEZE WINDOW TECHNOLOGY, NATURAL VENTILATION AND RWA OVERVIEW OF GEZE WINDOW TECHNOLOGY BEWEGUNG MIT SYSTEM

Cover photo: Oliver Look, photo on page 2: Siegelwerk GmbH

GEZE AUTOMATIC DOOR SYSTEMS SOLID STRENGTH WITH DELICATE EASE GEZE SLIMDRIVE SL NT SLIDING DOOR SYSTEMS BEWEGUNG MIT SYSTEM

Roll Up WireFree IR. Installation instructions

IQ Lock EL DL Motor Lock. IQ Lock EM DL Lever Lock. IQ Lock M DL Mechanical Panic Lock. GB Assembly and Operating

GEZe SEMI-CIRCULAR AND CIRCULAR SLIDING DOOR SYSTEMS INNOVATIVE TAILOR-MADE ENTRANCE SOLUTIONS

GEZE WINDOW TECHNOLOGY, NATURAL VENTILATION AND RWA OVERVIEW OF GEZE WINDOW TECHNOLOGY NATURAL VENTILATION AND RWA BEWEGUNG MIT SYSTEM

Installation instructions

GEZE AUTOMATIC DOOR SYSTEMS CONVENIENCE AND SAFETY EVEN FOR HEAVY DOORS GEZE POWERDRIVE THE POWERHOUSE BEWEGUNG MIT SYSTEM

GEZE AUTOMATIC DOOR SYSTEMS GEZE SEMI-CIRCULAR AND CIRCULAR SLIDING DOOR SYSTEMS INNOVATIVE TAILOR-MADE ENTRANCE SOLUTIONS BEWEGUNG MIT SYSTEM

Our strongest drive: The automatic swing door drive GEZE Powerturn

GEZE INSTALLATION OPTIONS

GEZE TSA 325 NT REVOLVING DOORS FOR MANUAL AND AUTOMATIC OPERATION. Available in Canberra from:

GEZE INSTALLATION OPTIONS

Plants. ColdMix Mobile/Semi-mobile and stationary plants. With productive capacity of t/h

DOUBLE OCTOMILL TM PRODUCT RANGE

GEZE AUTOMATIC DOOR SYSTEMS GEZE CURVED SLIDING DOOR SYSTEMS INNOVATIVE TAILOR-MADE ENTRANCE SOLUTIONS BEWEGUNG MIT SYSTEM

HOW TO SEND E-INVOICES TO CARGOTEC

No.1. Side approach mechanism Precise lateral contacting. Catalogue 1.1. Test Probes Test Fixtures

GEZE SLIMDRIVE SL SLIDING DOOR SYSTEMS PERFECTION EXTREMELY COMPACT. For more information go to BEWEGUNG MIT SYSTEM

GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS GEZE TS 3000 V / SYSTEM TS 5000 OVERHEAD DOOR CLOSERS WITH GUIDE RAIL BEWEGUNG MIT SYSTEM

PARTS MANUAL EMP 285ic 1ph & EMP 285ic 3ph

STEEL INDUSTRY ELECTRIC ARC FURNACES REFRACTORY CONCEPT SOLUTIONS

STEEL INDUSTRY STEEL LADLES REFRACTORY CONCEPT SOLUTIONS

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

GEZE TS 3000 V / SYSTEM TS 5000

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

Drive systems & electrical energy production for construction, local government structures, large infrastructure and industrial projects

Thermal Coal Market Presentation to UNECE Ad Hoc Group of Experts on Coal in Sustainable Development December 7, 2004

NI PS-15/16/17 Side Mount Brackets

Single-acting pneumatic cylinder type ECS

Iwaki Electromagnetic Metering Pump EWN-R (Chlorine Dioxide type)

1. General company data

Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps

Content. Door closer. Overview General information door closer 81 Allocation of sash width to dimension of door closer 82 Adjustment options 82

Installation Guide ELECTRONIC HEIGHT SENSOR.

Machines. Tandem Rollers ARX t

You ll find many Tsubaki products being

GEZE TS 3000 V / SYSTEM TS 5000

Facts and figures MULTILIFT V 6

Facts and figures INTEGRALPICKER V.

TS 73 EMF. Hold-open system

About Tapflo. Tapflo - your reliable pumpchoice. Tapflo quality. The history of Tapflo

BP Statistical Review of World Energy June 2017

1. INTERNATIONAL OVERVIEW. 1.0 Area and population. population (1,000) area

Door Closer DORMA TS 72

Magnetic drive pumps. A worldwide best-seller, our high-quality compact magnetic drive pumps GFRPP. Magnetic drive pumps. series.

Meaning of symbols Warning Caution. Prohibited. Required. Door Height. Door width. ±2 mm

Packing Data Installation Instructions

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

Knife gate valve JTV. Data is only for informational purpose. All specifications are subject to change without notice issue 11

TOP SMART intelligent position monitor:

4CKNYC[A2 A2 AKPFGZ GRU AXLE RAIL / 02

GEZE AUTOMATIC DOOR SYSTEMS GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER-FREE ACCESS. BEWEGUNG MIT SYSTEM

GEZE AUTOMATIC DOOR SYSTEMS GEZE SWING DOOR SYSTEMS CLEVER SYSTEMS. FOR BARRIER-FREE ACCESS. BEWEGUNG MIT SYSTEM

The Essentials Architectural Hardware. The Essentials Architectural Hardware. Electronic Locking Systems - DT Lite (Residential Version)

EMS215ic, EMP215ic, EM215ic

Extraction arms for every type of application

replacement parts 6.1 General 6.2 Ordering

Facts and figures MULTILIFT SELECT 6

FEDERAL RESERVE statistical release

Stafsjö s ATEX solutions for category 1 D (Zone 20)

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

NEW. PLASTIC MODULAR CHAIN WT0705-W Plastic Top Chain

Test Probes Test Fixtures INGUN. Test Fixtures for low PCB volumes. Change made easy

Spare Parts List Series VP04 Pneumatic Remote Control Valve

The ideal solution for doors up to 1100 mm wide tested and approved to EN 1154

Platform Systems. applications

Potential Danger of Fire or Explosion Read this letter now!

INSTALLATION GUIDE NI 9921/9922 Outdoor IP Enclosure For NI WLS-9000 Series Devices

Bearings for the Cement and Ready-Mix Concrete Industries

GEZE DOOR TECHNOLOGY GEZE TS 3000 EC. The intelligent closer INNOVATIVE SYSTEMS SOLUTIONS

PSF 250, PSF 305, PSF 405, PSF 505, PSF 405 RS3 PSF 410W, PSF 510W, PSF 410W RS3, PSF 510W RS3,

Armaturenwerk Hötensleben GmbH. AWH-Connect

Tapflo - your reliable pumpchoice

Sapa Door Closers. Soft, controlled and secure closing

Armaturenwerk Hötensleben GmbH. AWH-Connect

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

Knorr-Bremse Z-300 Condition Based Maintenance. Applications For Retrofit to All Passenger Rail Vehicles

MDM. Magnetic drive pumps Magnetic drive process pump resistant to dry run damage. Magnetic drive pumps. series

PREVIEW. Fieldbus System for Distributed I/O NEW PRODUCTS

Knife gate valve TV. Data is only for informational purpose. All specifications are subject to change without notice issue 9

INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

Spain s exports by oil product group and country of destination

Flying production. with travelling HF welding machines TDW & TDW-Mega. Built for you. Built to last. machines equipment expertise service

Machines. Trench Rollers Rammax 1575 and

Articulated Tandem Rollers ARX 9-11 t Tier 3/Tier 4i

Infographics on Electromobility (January 2019)

Trench Rollers Rammax 1575 and 1585

Spain s exports by oil product group and country of destination. Year Corporación de Reservas Estratégicas de Productos Petrolíferos

ESAB Welding & Cutting Products Attn: Customer Service Dept. P.O. Box , 411 S. Ebenezer Road Florence, SC

External Drive Axis Packages

Transcription:

Powerturn IS/TS Powerturn F-IS/TS Powerturn F/R-IS/TS EN Installation instructions 164692-00

Powerturn F/R-IS/TS Contents 1 Symbols and illustrations...3 2 Product liability...3 3 Safety...3 3.1 Proper use...3 3.2 Standards...3 3.3 Reference documents...3 3.4 Safety notices...4 4 Tools and aids...4 5 Types of installation...4 5.1 Type of installation transom installation hinge side...4 5.2 Type of installation transom installation opposite hinge side...4 5.3 Types of installation, hinge action...5 5.4 Fitting dimensions for the installation types...6 6 Product description...8 6.1 Descriptions of the TS5000L passive leaf unit...8 6.2 Descriptions of the TS4000 passive leaf unit...9 7 Installing the integrated Powerturn F closing sequence mechanism... 10 8 Converting the TS units... 12 8.1 TS 5000L - conversion from DIN right to DIN left... 12 8.2 TS 4000 - conversion from DIN right to DIN left... 14 8.3 Connecting the mechanism for integrated closing sequence control of active and passive leaf... 16 8.4 Install carry bar... 20 8.5 Install hold-open magnet... 20 8.6 Installing the electrical contact for passive leaf position monitoring... 21 9 Function check... 21 10 Commissioning... 21 11 Service and maintenance... 22 11.1 General information... 22 11.2 Maintenance of IS-mechanism... 22 12 Troubleshooting... 23 2

Powerturn F/R-IS/TS Symbols and illustrations 1 Symbols and illustrations Warning notices Warning notices are used in these instructions to warn you of property damage and personal injury. Always read and observe these warning notices. Observe all the measures that are marked with the warning symbol and warning word. Warning symbol Warning word Meaning CAUTION Danger to persons. Non-compliance may lead to minor injuries. Further symbols and means of representation Important information and technical notes are highlighted to explain correct operation. Symbol Meaning means important note means additional Information X X Symbol for an action: there is something you must do here. If there are several actions to be taken, keep to the given order. 2 Product liability In compliance with the liability of the manufacturer for its products as defined in the German "Product Liability Act", compliance with the information contained in this brochure (product information and intended use, misuse, product performance, product maintenance, obligations to provide information and instructions) must be ensured. Failure to comply releases the manufacturer from its statutory liability. 3 Safety 3.1 Proper use The Powerturn F-IS/TS integrated closing sequence control has been designed for mechanical control during the closing of double-leaf single-action swing leaf doors. The construction components required are a supplement to the Powerturn drive and must be installed according to these instructions. The Powerturn F-IS/TS integrated closing sequence control is designed for use on fire and smoke protection doors. may be used on escape and rescue route doors. must not be used for potentially explosive areas. The Powerturn IS/TS integrated closing sequence control must not be used on fire or smoke protection doors. may be used on escape and rescue route doors. must not be used for potentially explosive areas. Any improper use such as permanent manual operation of the Powerturn F, as well as any modification to the product, is not permitted. Observe the "GEZE Product information for door closers". 3.2 Standards In addition to the valid standards and regulations, DIN EN 1158 applies to the Powerturn. 3.3 Reference documents Powerturn installation instructions Powerturn wiring diagram Powerturn mechanism for integrated closing sequence control installation instructions Installation instructions TS5000L The diagrams are subject to change without notice. Use only the most recent version. Installation instructions TS4000 Installation instructions carry bar Installation instructions and wiring diagram hold-open magnet User information door closer 3

Tools and aids Powerturn F/R-IS/TS 3.4 Safety notices The description of the overall installation of the drive is not the subject of these instructions. This information can be found in the Powerturn installation instructions. All the necessary safety notices for conversion or extension to a double-leaf version can be found on the following pages. 4 Tools and aids Tool Dimensions Drill bits Ø 2 mm Open-ended spanner SW 5.5 Allen key 1.5 mm Allen key 2.5 mm Pozidrive screwdriver 5 Types of installation 5.1 Type of installation transom installation hinge side Active leaf Passive leaf 5.2 Type of installation transom installation opposite hinge side Passive leaf Active leaf 4

Powerturn F/R-IS/TS Types of installation 5.3 Types of installation, hinge action The opening angle of the door always has to be limited by a door stop buffer. Wind loads, negative pressure or excess pressure must be taken into account. We recommend the installation type involving link arms for the external doors. The following buffer stop types are available for DIN left and DIN right for Powerturn IS/TS, Powerturn F-IS/TS, and Powerturn F/R-IS/TS: 5.3.1 Rail installation and link arm Type of installation Dimension Powerturn F TS5000L Transom installation - Hinge side - Rail Reveal depth SD [mm] 0 Door overlap Ü [mm] 0-15 Max. door opening angle TÖW [ ] 1) 133 180 Standard roller guide rail L = [mm] 687 415 Lever L = [mm] 330 333 Hinge size [mm] 190 EN class 4-6 Max. door width [mm] O 1600 O 1400 Type of installation Dimension Powerturn F TS4000 Transom installation - Opposite hinge side - Link arm Reveal depth SD standard and with 0-160 sensor link arm [mm] Max. door leaf thickness [mm] 150 Max. door opening angle TÖW [ ] 1) 135 180 Hinge size [mm] 190 EN class 4-7 Max. door width [mm] O 1600 O 1600 1) depending on the door construction and door hinges used For other limits of use see: Powerturn installation instructions Installation instructions TS5000L Installation instructions TS4000 5

Types of installation Powerturn F/R-IS/TS 5.4 Fitting dimensions for the installation types 5.4.1 Type of installation transom installation hinge side 1 Dimensional reference - Centre of hinge/upper edge of door 2 2 concealed line-feed possible in the hatched area, e.g. Ø 20 mm for the mains connection or low-voltage connection 3 3 orientation arrows for precise positioning of the mounting plate Fastening means Steel/Aluminium doors Wooden doors Drive attachment 8 countersunk screws M6 25 and riveting nuts M6 8 wooden screws with countersunk head Ø6 50 TS attachment 4 cylinder head screws M6 20 and riveting nuts M6 4 wooden screws with cylinder head Ø6 50 Intermediate base plate attachment 4 cylinder head screws M6 25 and riveting nuts M6 4 wooden screws with cylinder head Ø6 50 Fastening standard roller guide rail Powerturn 2 countersunk screws M5 40 and riveting nuts M5 2 wooden screws with countersunk head Ø5 50 Fastening height adjustable guide rail TS5000L 2 countersunk screws M5 40 and riveting nuts M5 2 wooden screws with countersunk head Ø5 50 Space requirements and fastening Standard roller guide rail Powerturn Sensor roller guide rail Powerturn Guide rail TS5000L 130 10 10 36 42 10 22 10 4 26 92 10 42 36 22 10 7 92 19 9 50 5 5 50 15 66 6 15 41 31 50 50 4 Base - Upper edge of door 5 Space requirement - Sensors 6

Powerturn F/R-IS/TS Types of installation 5.4.2 Type of installation transom installation opposite hinge side Fastening - DIN right Fastening - DIN left 1 Dimensional reference - Centre of hinge/lower edge of frame 2 Covered line-feed possible in the hatched area, e.g. Ø 20 mm for the mains connection or low-voltage connection 3 Orientation arrow for precise positioning of the mounting plate Fastening means Steel/Aluminium doors Wooden doors Drive attachment 8 countersunk screws M6 25 and riveting nuts M6 8 wooden screws with countersunk head Ø6 50 TS attachment 4 cylinder head screws M6 20 and riveting nuts M6 4 wooden screws with cylinder head Ø6 50 Intermediate base plate attachment 4 cylinder head screws M6 25 and riveting nuts M6 4 wooden screws with cylinder head Ø6 50 Fastening the Powerturn link arm 2 cylinder head screws M6 16 and riveting nut M5 2 wooden screws with cylinder head Ø5 20 Fastening the link arm TS4000 2 cylinder head screws M5 16 and riveting nut M5 2 wooden screws with cylinder head Ø5 20 Fastening the adapter for the Powerturn sensor link arm 2 countersunk screws M6 20 and riveting nut M6 2 wooden screws with countersunk head Ø5 35 Space requirement and fastening Powerturn link arm Link arm TS4000 130 42 22 72 46 10 10 4 8* 43 35 11* 41 50 5 5 50 50 50 4 Base - Lower edge of lintel 5 Space requirement - Sensors * Important functional dimension 7

Product description Powerturn F/R-IS/TS 6 Product description 6.1 Descriptions of the TS5000L passive leaf unit 6.1.1 TS5000L passive leaf unit transom installation hinge side DIN right 1 2 Single side part (for continuous cover) Double side part (for split cover) 1 IS rocker 2 Return pulley 6.1.2 TS5000L passive leaf unit transom installation hinge side DIN left 2 1 1 IS rocker 2 Return pulley Single side part (for continuous cover) Double side part (for split cover) 8

Powerturn F/R-IS/TS Product description 6.2 Descriptions of the TS4000 passive leaf unit 6.2.1 TS4000 passive leaf unit transom installation opposite hinge side DIN right 1 Single side part (for continuous cover) Double side part (for split cover) 1 IS rocker 6.2.2 TS4000 passive leaf unit transom installation opposite hinge side DIN left 1 Single side part (for continuous cover) Double side part (for split cover) 1 IS rocker 9

Installing the integrated Powerturn F closing sequence mechanism Powerturn F/R-IS/TS 7 Installing the integrated Powerturn F closing sequence mechanism 1 2 SW 2.5 2,5 3 7 4 5 2.5 2,5 Nm 6 Transom installation opposite hinge side Installation position brake unit Opposite Hinge Side (OHS) Transom installation hinge side Installation position brake unit Hinge Side (HS) 10

Powerturn F/R-IS/TS Installing the integrated Powerturn F closing sequence mechanism 8 1 Nm SW 5.5 5,5 9 10 2.5 2,5 Nm SW 2.5 2,5 11 During installation of the setting lever, pay attention to the alignment of the mechanism for integrated closing sequence control (see below). The spring is always installed on the same side as the setting lever. See below for the alignment of the mechanism for integrated closing sequence control. Types of installation: Transom installation - hinge side, DIN left Transom installation - opposite hinge side, DIN right Types of installation: Transom installation - hinge side, DIN right Transom installation - opposite hinge side, DIN left 11

Converting the TS units Powerturn F/R-IS/TS 8 Converting the TS units 8.1 TS 5000L - conversion from DIN right to DIN left This chapter describes the conversion, if TS 5000L is to have a DIN left installation (TS5000L conversion see chapter 8.1.2 8.1.1 Factory setting for TS5000L is DIN right 8.1.2 Converting the TS5000L 1 2 4 3 4 Nm (2 ) 5 1 Nm (2 ) 12

Powerturn F/R-IS/TS Converting the TS units 6 7 6 Nm 9 8 5 Nm (4 ) 11 10 11 10 13

Converting the TS units Powerturn F/R-IS/TS 4 Nm (2 ) 12 12 4 Nm (2 ) 8.2 TS 4000 - conversion from DIN right to DIN left This chapter describes the conversion, if TS 4000 L is to have a DIN left installation (TS4000 conversion see chapter 8.2.2). 8.2.1 Factory setting TS4000 transom installation opposite hinge side DIN right 8.2.2 Converting the TS 4000 2 1 14

Powerturn F/R-IS/TS Converting the TS units 3 5 Nm (4 ) 4 6 Nm 5 7 6 7 6 15

Converting the TS units Powerturn F/R-IS/TS 4 Nm (2 ) 8 8 4 Nm (2 ) 8.3 Connecting the mechanism for integrated closing sequence control of active and passive leaf Install the drive and lever. For drive installation, see installation instructions Powerturn, prepare for installation and Installation sections. For TS installation, see the chapter 5.4. Installation of the guide rail and lever of the TS5000 L and setting the valves, see TS5000 L installation instructions. Installation of the link arm of the TS4000 and setting the valves, see TS4000 installation instructions. 8.3.1 Installing the Powerturn TS shaft covers TS5000L 1 2 8 Nm (2 ) 2 8 Nm (2 ) TS4000 1 8 Nm (2 ) 2 2 8 Nm (2 ) 16

Powerturn F/R-IS/TS Converting the TS units Connection of the active and passive leaf drive: 1 2 Passive leaf (1) Active leaf (2) With continuous cover, remove the side parts. Drill the passage in the side part for the split cover and deburr (depending on the route of the wire cable): Ø 2 mm Route of wire cable near the passive leaf unit: TS5000L TS4000 17

Converting the TS units Powerturn F/R-IS/TS Route of wire cable near the control: Position of setting lever with the brake closed Position of setting lever with the brake opened 18

Powerturn F/R-IS/TS Converting the TS units Attach the wire cable and spring on the wire cable tensioner 1 2 3 ~0,2 0.2 Nm SW 1.5 2.5 4 1 2 Setscrew (1), tension spring (2) 5 ~0,2 0.2 Nm 3 Position of the setting lever (3) = brake opened, active leaf closing. 19

Converting the TS units Powerturn F/R-IS/TS Set the retaining action of the integrated closing brake SW 2.5 2,5 The correct setting of the entire mechanism for integrated closing sequence control has been achieved when, with the brake closed and passive leaf closed, the setting lever takes up the position as designated for the open brake. The wire cable must be tensioned both with opened and closed integrated closing brake between the passive and active leaf unit. 8.4 Install carry bar CAUTION! Danger of crushing. Body parts can become caught between the door leaves Install carry bar. A carry bar must be installed in order to protect the main closing edge. Install the carry bar in compliance with the included installation instructions. 8.5 Install hold-open magnet A hold-open magnet must be installed for the hold-open function of the passive leaf. Install the hold-open magnet so as to ensure sufficient door opening. The hold-open magnet must be permanently and reliably attached to the building. Safeguard the connection cable between the hold-open magnet and the Powerturn against outside access. Connect the hold-open magnet in compliance with the included wiring diagram and the Powerturn wiring diagram, Holdopen system Powerturn F-IS/TS, F/R-IS/TS section. 20

Powerturn F/R-IS/TS Function check 8.6 Installing the electrical contact for passive leaf position monitoring To monitor the position of the passive leaf, the enclosed electrical contact must be installed on the passive leaf to ensure the proper function of the closing sequence control of the door leaves in the Powerturn s automatic mode If necessary, information must be obtained from the door manufacturer if the passive leaf is mechanically treated for installation of the contact and wiring. To connect the contact to the Powerturn control, see the wiring diagram, section Hold-open system Powerturn F-IS/TS, F/R-IS/ TS. 9 Function check Open the active and passive leaves up to the waiting position. Release the passive and active leaves. The passive leaf must start the closing movement immediately. The active leaf must remain in position until the brake is opened by the mechanism for integrated closing sequence control on the passive leaf. The active leaf closes. Further test requirements: see national/international standards and regulations. 10 Commissioning For adjusting the Powerturn spring force, see the Powerturn installation instructions, Settings section. For adjusting the TS5000L and TS4000 spring force, see the TS5000L and TS4000 installation instructions. For electrical connection, see the Powerturn wiring diagram, Mains connection section. The passive leaf must be closed for the Powerturn F/R-IS/TS teaching process. The Powerturn must be taught in as a single-leaf door, see Powerturn wiring diagram, Commissioning and service section. The parameters for the Powerturn must be set based on the specifications of the Powerturn wiring diagram, Hold-open system Powerturn F-IS/TS, F/R-IS/TS section. These settings can be used to complete the electrical function test. 21

Service and maintenance Powerturn F/R-IS/TS 11 Service and maintenance 11.1 General information Maintenance work on the closing sequence control must be carried out by an expert during the maintenance cycle of the Powerturn drive. For maintenance instructions for the Powerturn swing door drive, see Powerturn installation instructions Service and maintenance section. For maintenance instructions for the door closer, see the door closer user information. 11.2 Maintenance of IS-mechanism Clean hold-open magnet and test door hold-open capabilities. Check IS cable to ensure it is under tension; increase tension if needed or exchange cable if damaged. Check IS rocker for secure attachment to the door closer; tighten screw if needed or exchange the IS rocker if damaged. 1 2 Check castor (1) in the IS rocker to ensure it moves and turns easily. If it is stiff, exchange the IS rocker and castor together. For TS5000L: Check the return pulleys (2) for smooth function; lubricate and ensure smooth running function if needed. 22

Powerturn F/R-IS/TS Troubleshooting 12 Troubleshooting For troubleshooting and fault elimination see the fault table in the Powerturn wiring diagram, "Fault messages" section. 23

Germany GEZE Sonderkonstruktionen GmbH Planken 1 97944 Boxberg-Schweigern Tel. +49 (0) 7930-9294-0 Fax +49 (0) 7930-9294-10 E-Mail: sk.de@geze.com GEZE GmbH Niederlassung Süd-West Tel. +49 (0) 7152-203-594 E-Mail: leonberg.de@geze.com GEZE GmbH Niederlassung Süd-Ost Tel. +49 (0) 89-120 07 42-50 E-Mail: garching.de@geze.com GEZE GmbH Niederlassung Ost Tel. +49 (0) 30-47 89 90-0 E-Mail: berlin.de@geze.com GEZE GmbH Niederlassung Mitte/Luxemburg Tel. +49 (0) 6171-63610-0 E-Mail: frankfurt.de@geze.com GEZE GmbH Niederlassung West Tel. +49 (0) 201-83082-0 E-Mail: essen.de@geze.com GEZE GmbH Niederlassung Nord Tel. +49 (0) 40-2 19 07 16-13 E-Mail: hamburg.de@geze.com GEZE Service GmbH Tel. +49 (0) 18 02/92 33 92 E-Mail: service-info.de@geze.com Austria GEZE Austria E-Mail: austria.at@geze.com www.geze.at Baltic States GEZE GmbH Baltic States office E-Mail: office-latvia@geze.com www.geze.com Benelux GEZE Benelux B.V. E-Mail: benelux.nl@geze.com www.geze.be www.geze.nl Bulgaria GEZE Bulgaria - Trade E-Mail: office-bulgaria@geze.com www.geze.bg China GEZE Industries (Tianjin) Co., Ltd. E-Mail: Sales-info@geze.com.cn www.geze.com.cn GEZE Industries (Tianjin) Co., Ltd. Branch Office Shanghai E-Mail: chinasales@geze.com.cn www.geze.com.cn GEZE Industries (Tianjin) Co., Ltd. Branch Office Guangzhou E-Mail: chinasales@geze.com.cn www.geze.com.cn GEZE Industries (Tianjin) Co., Ltd. Branch Office Beijing E-Mail: chinasales@geze.com.cn www.geze.com.cn France GEZE France S.A.R.L. E-Mail: france.fr@geze.com www.geze.fr Hungary GEZE Hungary Kft. E-Mail: office-hungary@geze.com www.geze.hu Iberia GEZE Iberia S.R.L. E-Mail: info@geze.es www.geze.es India GEZE India Private Ltd. E-Mail: office-india@geze.com www.geze.in Italy GEZE Italia S.r.l E-Mail: italia.it@geze.com www.geze.it GEZE Engineering Roma S.r.l E-Mail: roma@geze.biz www.geze.it Poland GEZE Polska Sp.z o.o. E-Mail: geze.pl@geze.com www.geze.pl Romania GEZE Romania S.R.L. E-Mail: office-romania@geze.com www.geze.ro Russia OOO GEZE RUS E-Mail: office-russia@geze.com www.geze.ru Scandinavia Sweden GEZE Scandinavia AB E-Mail: sverige.se@geze.com www.geze.se Scandinavia Norway GEZE Scandinavia AB avd. Norge E-Mail: norge.se@geze.com www.geze.no Scandinavia Denmark GEZE Danmark E-Mail: danmark.se@geze.com www.geze.dk Singapore GEZE (Asia Pacific) Pte, Ltd. E-Mail: gezesea@geze.com.sg www.geze.com South Africa GEZE Distributors (Pty) Ltd. E-Mail: info@gezesa.co.za www.geze.co.za Switzerland GEZE Schweiz AG E-Mail: schweiz.ch@geze.com www.geze.ch Turkey GEZE Kapı ve Pencere Sistemleri E-Mail: office-turkey@geze.com www.geze.com Ukraine GEZE Ukraine TOV E-Mail: office-ukraine@geze.com www.geze.ua United Arab Emirates/GCC GEZE Middle East E-Mail: geze@emirates.net.ae www.geze.ae United Kingdom GEZE UK Ltd. E-Mail: info.uk@geze.com www.geze.com GEZE GmbH Reinhold-Vöster-Straße 21 29 71229 Leonberg Germany Tel.: 0049 7152 203-0 Fax.: 0049 7152 203-310 www.geze.com