RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Similar documents
RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

K50F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

XACA871 pendant control station XAC-A - 8 pushbuttons

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

XACA871 pendant control station XAC-A - 8 pushbuttons

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Surface mounting, flush mounting, and DIN track mounting

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

K50H004UP cam changeover switch - 4-pole A - screw mounting

Model Number Structure

MasterINTERFACE 39 Series - Relay interface modules

K30H001YP cam star-delta switch - 3-pole A - screw mounting

XACA871 pendant control station XAC-A - 8 pushbuttons

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

XACA871 pendant control station XAC-A - 8 pushbuttons

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

Solid State Relays contactor with Integrated Fuse Type RGC1F

Square D General Purpose Relays

VW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive

VW3A4552. Product datasheet Characteristics. Main 1 / 5

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Electronic On-Delay Timers TA8-A/TA8-SA

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

RUC industrial relays of small dimensions

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

55 Series - Miniature General Purpose Relays 5-10 A

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

Electronic Timer - Series Micon 225 Signal Based Multi - Function

H3DS-X - Solid State Two-Wire Timer

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

40 Series - Miniature PCB relays A. Features

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

Electronic timers CT-S range Function diagrams

Safety Standards. Model Number:


AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

5 mm contact pin pitch PCB or 95 series sockets

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

2 pole 10 A PCB mount A1 A

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

LR9 F OVERLOAD RELAYS

Slim P.C.B. Relays (EMR or SSR) A

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

1 Form A 5A small size power relay for interface

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Safety technique. Emergency Stop Module BH 5928, BI 5928

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

OsiSense XMLP Pressure Transmitters for Industrial Applications. Catalog

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

Thermal Overload Relays

Cat N 3. OVERALL DIMENSIONS

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Pendant control stations 6

Transcription:

Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition Component name Time delay type Time delay range [Us] rated supply voltage Voltage range [In] rated current 48 x 48 mm Selector switch on front panel Self-extinguishing Zelio Time Electronic timing relay Plug-in sub-base 11 pin(s) Relay 2 C/O timed contacts, AgNi (cadmium free) RE48A A B C Di 0.02...1.2 s 0.05...3 s 0.2...12 h 0.2...12 min 0.2...12 s 0.5...30 h 0.5...30 min 0.5...30 s 2...120 h 2...120 min 2...120 s 5...300 h 5...300 min 5...300 s 24...240 V AC/DC 50/60 Hz 0.85...1.1 Us AC 0.9...1.1 Us DC Repeat accuracy +/- 0.2 % of the maximum setting value conforming to IEC 61812-1 Temperature drift +/- 0.02 %/ C of the maximum setting value conforming to IEC 61812-1 Voltage drift 5 A +/- 0.2 %/V of the maximum setting value 48...240 V +/- 1 %/V of the maximum setting value 24...48 V Setting accuracy of time delay +/- 5 % of full scale at 25 C conforming to IEC 61812-1 Minimum pulse duration Reset time Pick up duration 20 ms >= 25 ms on de-energisation 55 ms On-load factor 100 % Maximum power consumption Maximum power consumption Breaking capacity Minimum switching current Maximum switching current Maximum switching voltage Electrical durability 1.1 VA 24 V 4.8 VA 240 V 0.5 W 24 V 1.7 W 240 V 1250 VA 100 ma 5 A 250 V AC/DC 100000 cycles The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. May 27, 2011 1

Mechanical durability Output voltage Marking 30000000 cycles 240 V 5 A AC-12 30 V 2 A DC-13 240 V 1.5 A AC-15 CE Surge withstand 1 kv (differential mode) conforming to IEC 61000-4-5 level 3 2 kv (common mode) conforming to IEC 61000-4-5 level 3 Mounting support Local signalling Product weight Base mounted: socket Panel mounted: system supplied with the product 1 LED yellow output relay state LED indicator green flashing: relay energised timing in progress LED indicator green on steady: relay energised, no timing in progress 0.14 kg Environment Humidity drift +/- 0.05 %/%RH of the maximum setting value conforming to IEC 61812-1 Immunity to microbreaks < 10 ms Dielectric strength 1 kv 1 ma/1 minute conforming to IEC 61812-1 Protection against electric shocks 4 kv category 3 conforming to IEC 60664-1 4 kv category 3 conforming to IEC 61812-1 Standards Product certifications 73/23/EEC 89/336/EEC 93/68/EEC EN 50081-1/2 EN 50082-1/2 IEC 60669-2-3 IEC 61812-1 CSA C-Tick CULus GL UL Ambient air temperature for storage -40...70 C Ambient air temperature for operation -20...50 C IP degree of protection IP40 (housing) conforming to IEC 60529 IP50 (front face) conforming to IEC 60529 Vibration resistance 0.35 mm (f = 10...55 Hz) conforming to IEC 60068-2-6 Relative humidity 93 % without condensation conforming to IEC 60068-2-3 Resistance to electrostatic discharge 6 kv (in contact) conforming to EN/IEC 61000-4-2 level 3 8 kv (in air) conforming to EN/IEC 61000-4-2 level 3 Resistance to electromagnetic fields 10 V/m, 26 MHz to 1 GHz conforming to IEC 61000-4-3 level 3 Resistance to fast transients 2 kv, capacitive connecting clip conforming to EN/IEC 61000-4-4 level 4 4 kv, direct conforming to EN/IEC 61000-4-4 level 4 Immunity to radioelectric fields 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 level 3 Immunity to voltage dips 30 %/10 ms conforming to EN/IEC 61000-4-11 60 %/100 ms conforming to EN/IEC 61000-4-11 95 %/5 s conforming to EN/IEC 61000-4-11 Disturbance radiated/conducted Class B (0.15...30 MHz) conforming to EN 55022 (EN 55011 group 1) RoHS EUR status Compliant RoHS EUR conformity date 0622 2

Technical Function A: Delay on Energisation The timing period T begins on energisation. After timing, the output R closes. T = t1 + t2 + t3 Function B: Timing on Impulse, One Shot After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial state. T = t1 + t2 + t3 Function C: Timing After of Control Contact After power-up and closing of the control contact, the output closes. When control contact re-opens, timing T starts. At the end of the timing period, the output reverts to their initial state. T = t1 + t2 + t3 Function Di: Symmetrical Flashing, Start with Output in Operating Position Repetitive cycle with two timing periods T of equal duration, with output changing state at the end of each timing period T. Legend 3

Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/ 2 timed outputs R2 R2 The second output is instantaneous if the right position is selected inst. T Timing period Ta Adjustable On-delay Tr Adjustable Off-delay U Supply 4

Dimensions Drawings Width 48 mm 5

Mounting and Clearance Panel Cut-Out and Mounting Panel Cut-Out n Number of devices mounted side-by-side Mounting Cover positioning and mounting e Panel thickness 1 Protective cover 2 Panel mounting frame 3 Locating screw 6

Connections and Schema Wiring Diagram 7