Sludge Dewatering and Odor Control at Plant 1 CONFORMED

Similar documents
PRODUCT CATALOG THE BEST IN FIRE PROTECTION EQUIPMENT

Price Book - Section C Valves and Hose Equipment

ANGLE VALVES 300LB. RATED OPTIONAL FINISHES: PB- Polished Brass RC- Rough Chrome Plated PC- Polished Chrome Plated U/L LISTED NY BSA/MEA APPROVED

Price Book - Section C Valves and Hose Equipment

Copyright 2012 AIA MasterSpec Premium 06/12 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CONBRACO, INC.


Series 751 FireLock European Alarm Check Valve Stations

SECTION FACILITY FUEL OIL PIPING

Series 756 FireLock Dry System Check Valve

Approved Branded Traceable Fire Protection & Waterworks Valves

Section L Wet Pipe Systems

Instructions for Installation, Operation, Care and Maintenance

SECTION VALVES PART 1 -GENERAL

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

Grooved Piping System for Fire Protection Services

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

FIRE PROTECTION PRODUCTS

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC VALVES

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler System Controls Revised

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Series 769 FireLock NXT Deluge Valve

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Valve Selection. 1. Function and service considerations

FIELD ADJUSTABLE REG-U-MATIC PRESSURE REGULATING VALVES

Grooved Piping System for Fire Protection Services

Capital Projects Group Fire Protection Standpipe System Specification

BS 5163 Resilient Wedge Gate Valve

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

TECHNICAL DATA. Trimpac 249a. September 16, 2013

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

GENERAL-SERVICE COMPRESSED-AIR PIPING SECTION GENERAL-SERVICE COMPRESSED-AIR PIPING PART 1 - GENERAL

Series 758 FireLock Actuated System Valve

Henderson Engineers, Inc. SECTION GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS

Instructions for Installation, Operation Care and Maintenance

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs

INSTALLATION, OPERATION, and MAINTENANCE GUIDE NIBCO Wall Mount Indicator Posts Series NIP-2AW

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Lightweight Aluminum Alloy Adapters

SECTION HVAC WATER PIPING ACCESSORIES

TECHNICAL DATA CAUTION

Hose Racks HOSE RACKS & REELS HOSE RACKS & REELS HOSE RACKS

SECTION VALVES

SUBMITTAL PACKAGE FIRE PROTECTION VALVES

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Easy Riser swing check valve Models E-1 & F-1

Price Book - Section 16 Specialty Items

PIPE OUTSIDE DIAMETER GUIDE

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

September 2012 / M&H C502 / Model 129

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT

TECHNICAL DATA OBSOLETE

Division 23 - HVAC Section Switzerland Beallsville K-12 GENERAL DUTY VALVES FOR HVAC PIPING

SECTION PLUMBING PIPING VALVES AND ACCESSORIES PART 1 - GENERAL

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR HVAC PIPING Page

Instructions for Installation, Operation, Care, and Maintenance

Water Distribution Solutions

TECHNICAL DATA OBSOLETE

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Valves. BS Standard JINAN MEIDE CASTING CO., LTD.

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR PLUMBING PIPING Page

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

TotalPac 3 Non interlock Preaction system Pneumatic release

TotalPac 3 Deluge, Electric release Remote controlled system

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

800 Series Control Valves

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Fire Protection Valves

Price Book - Section 16 Specialty Items

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

SECTION (15110) - GENERAL DUTY VALVES FOR PLUMBING PIPING

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

1. All piping shall have flow arrows indicating direction of flow.

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

FireFlex DUAL Single Interlock, Remote controlled system

Approved. Size L H. 3" (76mm) 9-1/2" (241mm) 5-51/64" (147mm) 46. 4" (102mm) 11-1/2" (292mm) 6-45/64" (170mm) 81

TotalPac 3 Deluge system Pneumatic release

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

GENE RICH SPECIALTIES

Instructions for Installation, Operation, Care and Maintenance

A. This Section includes the following domestic water piping specialties:

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Water Distribution Solutions

15100 VALVES. E. Section Building Automation and Control System Guidelines

Bid # Plumbing Supplies RESULTS

Transcription:

2. Fire Service Main Interior Piping from Exterior Service up to Fire Sprinkler Alarm Check Valve: a. Pipe: Schedule 40 galvanized steel. b. Fittings: Galvanized 150-pound malleable iron, screwed or Victaulic full-flow galvanized fittings with Style 77 couplings. 3. Drain Piping: a. Pipe: Schedule 40 galvanized steel. b. Fittings: Galvanized, malleable iron, screwed. 4. Fire Department Connection: a. Pipe: Schedule 40 galvanized steel. b. Fittings: Galvanized, malleable iron, screwed. 5. Reducing Fittings: a. One-piece pipe size reducing fittings. Same specifications as other fittings for type of pipe. b. Bushing reductions not acceptable. B. Pipe Supports: Provide pipe support and bracing to comply with Section 15020, Pipe Supports, NFPA 13, and California Building Code regarding seismic restraint. C. Valves: 1. Manufacturer: Stockham, Viking, Grinnell, Or Equal. Manufacturer's figure numbers specified are for type, quality, and features desired. All valves shall be ULlisted for fire protection service and Factory Mutual-approved. 2. Control Valves: Outside screw and yoke gate valves or butterfly valves, locked open, with breakable shackle lock. 3. Drain Valves: a. Angle globe, Stockham No. B-222, Or Equal from Viking, Grinnell. b. Straight, globe, Stockham No. B-22, Or Equal from Viking, Grinnell. 4. Check Valves: UL-listed, swing check installed horizontally, Stockham No. G-940, Or Equal from Viking, Grinnell. 5. Indicator Valves: UL-listed, as manufactured by Mueller, Grinnell, Or Equal, locked open, with breakable shackle lock. D. Fire Department Connection: Potter-Roemer, Croker Or Equal, all bronze, Siamese, wall mount or freestanding as indicated. 4-inch F.I.P.T. outlet, two 2-1/2-inch spring back check valved inlets, drain cock, caps and chains, threads per fire department requirements. Provide cast sign plate reading "AUTOSPKR." All parts, including exposed freestanding barrel, shall be polished chrome plated unless noted otherwise. E. Alarm Check Valve: UL-listed, installed on riser, suitable for variable pressure, complete with retard chamber and approved pressure switches for alarm bell and for electrical supervisory system. F. Alarm Bell: UL-listed, approved 10-inch electric bell, complete with suitable identification sign. Provide for each riser. Sludge Dewatering and Odor Control at Plant 1 FIRE PROTECTION Project No. P1-101 SPRINKLER SYSTEM CONFORMED 15330-5

EXPOSED FIRE DEPT. INLET CONNECTIONS-CLAPPER TYPE 5710-5734 SPECIFICATIONS TWO-WAY WITH SINGLE CLAPPER Cast brass two-way inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected. Size 4 x 2-1/2 x 2-1/2. UL File #EX4078 Model #S201B TWO-WAY WITH DOUBLE CLAPPER Cast brass two-way inlet body, drop clappers and pin lug swivels. Size and outlet as selected by model number. Lettering as selected. S U G G E S T E D MODEL SELECTION PRODUCT OPTIONS MODEL 5710 (Shown) TWO-WAY WITH SINGLE CLAPPER o 5710 Back Outlet (UL Listed) FM o 5715 Angle Outlet (UL Listed) FM TWO-WAY WITH DOUBLE CLAPPER o 5721 Back Outlet o 5722 Back Outlet o 5723 Back Outlet o 5724 Back Outlet o 5731 Angle Outlet o 5732 Angle Outlet o 5733 Angle Outlet o 5734 Angle Outlet FINISHES: o -B o -C o -D THREADS: Polished Brass Rough Chrome Plated Body Polished Chrome Plated o N.S.T. o Other LETTERING AVAILABLE: o AUTO. SPKR. o STANDPIPE Note: Refer to Model Dimensional Chart for UL & FM Listing 5710-5734 Date: 10/20/15

EXPOSED FIRE DEPT. INLET CONNECTIONS-CLAPPER TYPE 5710-5734 MODEL DIMENSIONS TWO-WAY WITH SINGLE CLAPPER UL Listed File #EX4078 Model #S201B MODEL 5710-5715 Outlet Approvals Outlet Approvals Back #EX3314 TWO-WAY WITH DOUBLE CLAPPER Angle #EX3314 Size A B C 5721 Yes 5731 Yes 4 x 2-1/2 x 2-1/2 7-1/2 11-1/2 8-1/2 11-1/2 5722 Yes 5732 Yes 6 x 2-1/2 x 2-1/2 9-1/2 10-1/2 9 10-3/4 5723 Yes 5733 Yes 4 x 3 x 3 9-1/2 11-1/2 9-1/2 11 5724 Yes 5734 Yes 6 x 3 x 3 10 11 10-1/2 11 D UL Listed File #EX3314 Model #A105 MODEL 5721-5734 5710-5734 Date: 10/20/15

FIRE DEPT. CONNECTIONS ACCESSORIES 5902-5953 SPECIFICATIONS OPEN SNOOTS Cast brass connection with size and type of inlet and outlet as selected by model number. Polished brass exposed parts CHECK SNOOTS WITH PIN LUG SWIVEL Cast brass connection with size and type or inlet and outlet and check as selected by model number. Polished brass exposed parts. CLAPPER SNOOTS WITH PIN LUG SWIVEL Pin Lug - Cast brass pin lug plug with male hose thread with attached chain. Size as selected by model number. S U G G E S T E D Pentagon Head - Cast brass pentagon head plug with male hose thread and attached chain. Size as selected by model number. BREAKABLE CAPS Aluminum cover with breakable ears, two eye bolts and nuts for attachment to female pin lug swivel. MODEL SELECTION OPEN SNOOTS o 5902 o 5903 o 5905 o 5911 o 5912 o 5913 o 5915 o 5922 o 5923 o 5925 SPRING CHECK SNOOTS WITH PIN LUG SWIVEL o 5930 o 5933 o 5935 o 5936 CLAPPER CHECK SNOOTS WITH SWIVEL INLET o 5937 o 5938 PLUGS AND CHAIN o 5941 o 5942 PRODUCT OPTIONS FINISHES: o -B o -C MODEL 5922 (Shown) MODEL SELECTION (CONT.) o 5943 o 5944 o 5945 o 5948 BREAKABLE CAPS o 5950 o 5953 o -D Polished Brass (Plugs and Chain Models Only) Rough Chrome Plated Body (Plugs and Chain Models Only) Polished Chrome Plated VARIATIONS: (Breakable Cap Models Only) o -P Red plastic breakable cap 2-1/2 size THREADS: (Not Available on Breakable Cap Models) o N.S.T. o Other 5902-5953 Date: 05/10/16

FIRE DEPT. CONNECTIONS ACCESSORIES 5902-5953 MODEL DIMENSIONS N.P.T. Inlet Hose Outlet 5902 2-1/2" 2-1/2" 5903 3" 2-1/2" 5905 3" 3" OPEN SNOOTS Hose Inlet N.P.T. Outlet 5911 1-1/2" 1-1/2" 5912 2-1/2" 2-1/2" 5913 2-1/2" 3" 5915 3" 3" Hose Inlet N.P.T. Outlet 5922 2-1/2" 2-1/2" 5923 2-1/2" 3" 5925 3" 3" Female Inlet x Male Outlet Female Inlet x Male Outlet with Pin Lug Swivel Double Female with Pin Lug Swivel CHECK SNOOTS WITH PIN LUG SWIVEL SPRING CHECK Hose Inlet N.P.T. Outlet 5930 2-1/2" 3" Female 5933 3" 3" Female 5935 2-1/2" 3" Male 5936 3" 3" Male CLAPPER TYPE Hose Inlet N.P.T. Outlet 5937 2-1/2" 3" Female 5938 2-1/2" 3" Male Double Female Female Inlet x Male Outlet Double Female Female Inlet x Male Outlet PLUGS AND CHAIN & BREAKABLE CAPS Size 5941 2-1/2" 5942 3" 5943 4" 5944 4-1/2" Size 5945 2-1/2" 5948 3" Size 5950 2-1/2" 5953 3" Pin Plug Pentagon Head Breakable Cap 5902-5953 Date: 05/10/16

VALVES SWING CHECK VALVE 4510 SPECIFICATIONS 4 Forged body with spring loaded brass check, body tapped 1/2 N.P.T. at inlet for ball drip. FUNCTIONS Used to permit flow only in designated direction and prevent backflow. Type of installation as selected by model number. S U G G E S T E D MODEL SELECTION o 4510 Grooved o 4515 Male x Grooved o 4520 Male x Female PRODUCT OPTIONS MODEL 4510 (Shown) No Available Options MODEL DATA MODEL 4515 Male x Grooved MODEL 4520 Male x Female 4510 Date: 09/04/15