IMPACT TESTING ON SAFETY GLAZING MATERIAL. Rendered to:

Similar documents
AAMA THERMAL PERFORMANCE REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: 200 Series Curtainwall (E2297) TYPE: Glazed Wall System

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TORO ALUMINUM. SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning

AAMA THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

New Gateway 101/I.S.2/A440

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B ml Container (Mfg. Date , Lot # 2K15)

CE conform applications according to EN External door with thermal break System Forster unico

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B602-10, V302 and B202-1WNL Vial Variables TEST REPORT #:

AAMA THERMAL PERFORMANCE REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC.

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

Type 543. Three-way Ball Valve

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units.

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

WET PENDULUM SLIP RESISTANCE Job No: M14/7986

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California

Report No 2370/ This Report consists of 40 pages. Authority & date Request by Client dated 25 November 2010

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016

PENTAGON PROTECTION USA

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: EARTHWISE GROUP, L.L.C

Flexible Arm Stand F 360. User Manual

Type 375. True Union Ball Valve

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard. : BM 72 Hinged Window System. : Burak Aluminyum San ve Tic. A.Ş.

Test Report. Report No: BSTDG YRR-4 Date: Mar. 27, 2015 Page 1 of 7. :No.27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province

from one solar collector.

Report Issued: October 19, 2014 Project No.: 23942

600 Amp Surge Arrester

RSL Energy Efficiency and STC Ratings. Energy efficiency and beauty at your doorway!

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

CERTIFICATE of QUALITY TEST

Type 567. Wafer Style Butterfly Valve

Lug Style Butterfly Valve Type 578

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE

INTERNATIONAL COURT OF APPEAL (I.C.A.) of the FEDERATION INTERNATIONALE DE L'AUTOMOBILE

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE

UN/SCETDG/43/INF.5. Packing requirements for UN1873. Transmitted by the Council on Safe Transportation of Hazardous Articles (COSTHA)

Type 514, 515, 517, 519

MITEQ AM-1185 SERIES AMPLIFIER

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

Industry/PennDOT Initiative On Performance Testing. AN UPDATE January 22, 2019

Test report No.: VU

The reason for higher electric bills

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Medical Waste Transporters

One-line distributor e.g. VEI-A. One-line aggregate GEI-A

Type Electrically Actuated Ball Valve

TEST REPORT. Report Number : / Report Date : 12 / 03 / : TS EN A1 Windows and Doors - Product Standard

Documents and Addresses

Endurance Testing of Redesigned Tab Spring for MI-RAMS System

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

SHINE 3000 POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

Graphic. Air Compliance Issues and Solutions. Sunita Dhar, PhD Senior Scientist First Environment 91 Fulton Street, Boonton

ASTM B117 Testing Quality Control

PRODUCT DATA SHEET P5

Rotameters. Variable Area Flow Meters

GENERATOR SHELTER IMPACT TEST REPORT (.08 Material)

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

Sound absorption coefficient ISO 354 Measurement of sound absorption in reverberation rooms

Electrical Power Generator Use and Procurement Guidance

FULL PORT STANDARD PORT COMPLETE SIZE RANGE. Superior Flow Easy Operation Full Traceability State-of-the-Art Manufacturing

Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

Prüffeld der Schaltwerke

Slide-locks Enforcement Policy, Inspection Procedures and Performance Guidance Criteria

Distributed By Aetna Plastics Pneumatically Actuated Diaphragm Valve DIASTAR Ten and TenPlus General Size: ½ 2 Material: PVC, CP

Applicable Product Numbers:

Wood and Aluminum EnduraClad Exterior 6' 8" and 6' 10" Size Tables

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

PRODUCT EVALUATION REPORT

Superior by Design. Euro vista wood impact/non impact rated wood folding door systems

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard : ASISTAL LS 60 SERIES HEBE-SCHIEBE SYSTEM

Simply Sliding Door Systems

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

Work Zone Safety Initiatives and Research Efforts. Irene Soria Safety Evaluation Engineer Illinois Department of Transportation Safety Engineering

ANSI/API Standard 607 Sixth Edition 2010 ISO 10497: 2010 Fire Test Certificate

Diaphragm Valve MV 310

VIBRATION AND MECHANICAL SHOCK TEST REPORT

Up-Coming Diesel Fuel and Exhaust Emissions Regulations For Mobile Sources. Parminder Khabra RDECOM-TARDEC TACOM LCMC March 22, 2006 JSEM

Reference Number: SMS-4211-L1, Rev 0 Date: May 2, 2018

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC.

Blast Protection Damper

Transcription:

IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße 18 4400 Steyr Austria Report No: 01-49266.03 Test Date: 01/29/04 Report Date: 03/26/04 6 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 69ºF Duration of Pre-Conditioning @ 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z97.1-1984 5.87 48 21 95 2 ANSI Z97.1-1984 5.86 48 Did Not Break 95 3 ANSI Z97.1-1984 5.87 48 Did Not Break 95 4 ANSI Z97.1-1984 5.86 48 27 95 5 16 CFR 1201 5.88 48 Did Not Break 95 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb 01-49266.03 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com

IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße 18 4400 Steyr Austria Report No: 01-49266.05 Test Date: 01/30/04 Report Date: 03/26/04 8 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 66ºF Duration of Pre-Conditioning @ 70 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z97.1-1984 7.89 48 Did Not Break 128 2 ANSI Z97.1-1984 7.87 48 Did Not Break 128 3 ANSI Z97.1-1984 7.90 48 Did Not Break 128 4 ANSI Z97.1-1984 7.90 48 Did Not Break 128 5 16 CFR 1201 7.87 48 Did Not Break 128 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb 01-49266.05 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com

IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße 18 4400 Steyr Austria Report No: 01-49266.04 Test Date: 01/29/04 Report Date: 03/26/04 10 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 69ºF Duration of Pre-Conditioning @ 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z97.1-1984 9.86 48 Did Not Break 160 2 ANSI Z97.1-1984 9.86 48 Did Not Break 160 3 ANSI Z97.1-1984 9.89 48 Did Not Break 160 4 ANSI Z97.1-1984 9.89 48 Did Not Break 160 5 16 CFR 1201 9.91 48 Did Not Break 161 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb 01-49266.04 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com

IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße 18 4400 Steyr Austria Report No: 01-49266.06 Test Date: 01/30/04 Report Date: 03/26/04 12 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 67ºF Duration of Pre-Conditioning @ 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z97.1-1984 12.03 48 Did Not Break 195 2 ANSI Z97.1-1984 12.04 48 Did Not Break 195 3 ANSI Z97.1-1984 12.09 48 Did Not Break 196 4 ANSI Z97.1-1984 12.09 48 Did Not Break 196 5 16 CFR 1201 12.08 48 Did Not Break 196 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb 01-49266.06 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com

IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße 18 4400 Steyr Austria Report No: 01-49266.01 Test Date: 01/29/04 Report Date: 03/26/04 15 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 68ºF Duration of Pre-Conditioning @ 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z97.1-1984 14.93 48 Did Not Break 242 2 ANSI Z97.1-1984 14.98 48 Did Not Break 243 3 ANSI Z97.1-1984 15.01 48 Did Not Break 244 4 ANSI Z97.1-1984 14.94 48 Did Not Break 242 5 16 CFR 1201 14.99 48 Did Not Break 243 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb 01-49266.01 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com

IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße 18 4400 Steyr Austria Report No: 01-49266.02 Test Date: 01/29/04 Report Date: 03/26/04 19 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 68ºF Duration of Pre-Conditioning @ 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z97.1-1984 18.88 48 Did Not Break 306 2 ANSI Z97.1-1984 18.86 48 Did Not Break 306 3 ANSI Z97.1-1984 18.75 48 Did Not Break 304 4 ANSI Z97.1-1984 18.88 48 Did Not Break 306 5 16 CFR 1201 18.85 48 Did Not Break 306 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb 01-49266.02 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.archtest.com